• Title/Summary/Keyword: test scale

Search Result 9,598, Processing Time 0.037 seconds

Development of the Scale Track to Test Bogie Steering Performance (대차 조향 특성 시험을 위한 축소 트랙 개발)

  • Hur, Hyun-Moo;Park, Jun-Hyuk;You, Won-Hee;Park, Tae-Won
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.301-305
    • /
    • 2007
  • The performance of the railway bogie is classified into the stability and the steering performance. Testing for the bogie stability is conducted on the roller rig. But testing for the bogie steering performance on test facility is very difficult, so the testing for the vehicle curving performance is conducted on the real curve track. And it is desirable to test on the full scale test rig, but it caused many problems relating to test costs, test time. To overcome these problems, the small scale test rig is actively used in the field of bogie stability. Thus, in this paper, we have studied the scale track to test the bogie steering performance. For this, we designed the 1/5 scale test track equivalent to radius 200 curve and confirmed the validity of the testing for the bogie steering performance on the scale curve track through the testing using 1/5 scale bogie.

  • PDF

The Correlations among the Dynamic Gait Index the Berg Balance Scale and Timed Up & Go Test in people with stroke (뇌졸중 환자에서 Dynamic Gait Index와 Berg Balance Scale 및 Timed Up & Go 검사간의 상관관계)

  • Lee, Sang-Ho;Hwang, Byoung-Yong
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.3
    • /
    • pp.1-8
    • /
    • 2008
  • The purpose of this study was to compare the relationship among the Dynamic Gait Index(DGI), Berg Balance Scale(BBS) scores, Timed Up & Go Test(TUG), and subject characteristics. The subjects were fifteen stroke with hemiplegia were chosen in the Konyang University Hospital. Dynamic balance was measured Dynamic Gait Index(DGI), and balance was measured using Berg Balance Scale(BBS). Timed Up & Go Test(TUG) was used to evaluate functional mobility. Data were analyzed using Spearman correlation. There was significant correlated among Dynamic Gait Index(DGI), Berg Balance Scale(BBS) and Timed Up & Go Test(TUG)(p<.01). The correlation among subject characteristics and Dynamic Gait Index(DGI), Berg Balance Scale(BBS), Timed Up & Go Test(TUG) score was significant result in r = -.527 from Dynamic Gait Index(DGI) and pathogenesis(p<.05). There were no significant statistical differences among the types of spasticity and Dynamic Gait Index(DGI), Berg Balance Scale(BBS), Timed Up & Go Test(TUG). The comparison among the sex, type of hemiplegia, pain, pathogenesis and Dynamic Gait Index(DGI), Berg Balance Scale(BBS), Timed Up & Go Test(TUG) score was significant result in pathogenesis(p<.05). The results of this study showed that there was high correlations among the Dynamic Gait Index(DGI) and balance test of people with stroke.

  • PDF

Pressurization Test for Full-scale Static Test of T-50 Aircraft (고등훈련기 전기체 정적시험을 위한 여압시험)

  • Shim, Jae-Yeul;Kim, Tae-Uk;Song, Jae-Chang;Hwang, Gui-Chul;Hwang, In-Hee
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1384-1387
    • /
    • 2003
  • Pressurization test is usually required in aircraft full-scale static test. There are several test conditions including pressurization of cockpit, fuselage fuel tank, air inlet duct for T-50 full-scale static test. In this paper, the test conditions, equipment, piping analysis for the pressurization test are introduced. Tank simulation test is performed to verify the validity of piping analysis and to find good tuning parameters for the pressurization channel in the servo controller. Several test setup for pressurization of T-50 test is introduced. Test article volume is filled by form, $60%{\sim}80%$ volume is reduced for the T-50 full-scale static test. Pressurization system is connected to servo controller which also controls hydraulic actuator. Load and pressure control is synchronized by using the same servo controller during T-50 test. Typical control result for pressurization test condition is shown. Pressurization tests of T-50 full-scale static test was completed successfully.

  • PDF

The Effect of Scale Parameter in Designing Reliability Demonstration Test for Lognormal Lifetime Distribution (대수정규 수명분포를 갖는 제품에 대한 신뢰성 입증시험에서 척도모수의 영향분석)

  • Kwon, Young Il
    • Journal of Applied Reliability
    • /
    • v.14 no.1
    • /
    • pp.53-57
    • /
    • 2014
  • In the fields of reliability application, the most commonly used test methods for reliability demonstration are zero-failure acceptance tests since they require fewer test samples and less test time compared to other test methods that guarantee the same reliability with a given confidence level. For products with lognormal lifetime distribution, the value of scale parameter is usually assumed to be known in designing reliability demonstration tests. It is important to select correct values of scale parameters to guarantee the specified reliability with given confidence level exactly. The effect of using wrong values of scale parameters in designing reliability demonstration test for products with lognormal lifetime distribution is examined and selecting proper values of scale parameters for conservative reliability demonstration is discussed.

Consistency of a Modified W Test for Exponentiality

  • Kim, Namhyun
    • Communications for Statistical Applications and Methods
    • /
    • v.9 no.3
    • /
    • pp.629-637
    • /
    • 2002
  • Shapiro and Wilk(1972) developed a test for exponentiality with origin and scale unknown. The procedure consists of comparing the generalized least squares estimate of scale with the estimate of scale given by the sample variance. However the test based on the statistic is inconsistent Kim(2001a) proposed a modified Shapiro-Wilk's test statistic using the ratio of two asymptotically efficient estimators of scale. In this paper, we study the consistency of the proposed test.

Analysis on the Propulsive Performance of Full Scale Ship (실선의 추진성능 해석기법에 관한 연구)

  • Yang, Seung-Il;Kim, Eun-Chan
    • 한국기계연구소 소보
    • /
    • s.9
    • /
    • pp.183-191
    • /
    • 1982
  • This report describes the analysis method of the full-scale propulsive performance by using the data of model test and the full-scale speed trial. The model test data were analyzed by the computer program "PPTT" based on "1978 ITTC Performance Prediction Method for Single Screw Ships." Also the full-scale speed trial data were analyzed by the computer program "SSTT" based on the newly proposed “SRS-KIMM Standard Method of Speed Trial Analysis." An analysis of model and full-scale test data was carried out for a 60.000 DWT Bulk Carrier and the correlation between model and full-scale ship was stuied.

  • PDF

Performance Trial-Test of the Full-Scale Driving Pump for the Large Cavitation Tunnel(LCT) (대형캐비테이션터널(LCT) 실물 구동펌프 성능시운전)

  • Ahn, Jong-Woo;Kim, Gun-Do;Kim, Ki-Sup;Park, Young-Ha
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.6
    • /
    • pp.428-434
    • /
    • 2015
  • The objective of the present study is to analyze the results of the trial-test for the full-scale driving pump, which is arranged in the LCT (Large Cavitation Tunnel). Firstly, the reasons of selecting the final design pump are introduced in terms of the performance analysis in model tests. The trial-test items for the full-scale driving pump are measurements of output current/voltage at the inverter of the main motor and the flow velocity in the LCT test section. The test results show the increase in flow rate of about 10.7% and the decrease in pump head of about 26%, compared with those of final design-pump specification. The motor power has the margin of about 22%. The performance analysis for the full-scale pump is conducted using the commercial code (CFX-10). The delivered power calculated with CFX-10 shows good agreement with that extracted from the full-scale pump test. It is found that CFX-10 is useful to analyze a full-scale pump.

Wind Tunnel Test for Scaled Wind Turbine Model (Scale effect correction) (축소형 풍력터빈 풍동시험-축소효과 보상기법)

  • Cho, Tae-Hwan;Kim, Yang-Won;Park, Young-Min;Chang, Byeong-Hee
    • New & Renewable Energy
    • /
    • v.4 no.2
    • /
    • pp.87-93
    • /
    • 2008
  • Wind tunnel test for the 12% scaled model of NREL Phase VI wind turbine was conducted in KARI low speed wind tunnel for $2006{\sim}2007$. The 1st and 2nd test was designed to find out the wind tunnel test method for the blade manufacturing accuracy and surface treatment method by using the composite and aluminum blades. And the 3rd test was designed to study the scale effect. The chord extension method which was used for Bo-105 40% scaled model was adapted for scale effect correction. Test results shows that the chord extension method works well for the torque slope but the maximum torque for scaled model is about 8% below than the real scale model. New correction method to correct this offset was proposed.

  • PDF

A Preliminary Study for the Application of Cognitive Function Scale(ACFS) in Korean Setting (인지기능응용척도의 타당화를 위한 기초 연구)

  • Cho, Eun-Lae;Hwang, Hae-Ik
    • Korean Journal of Child Studies
    • /
    • v.31 no.3
    • /
    • pp.235-254
    • /
    • 2010
  • The purpose of this study was to examine the feasibility and validity of the Application of Cognitive Function Scale as developed by Lidz and Jepsen (1997). Data were collected from 4 to 5-years-old children. The analysis for item adequacy indicated that the passing rate increases according to age. Futhermore the analysis for test adequacy indicated that internal consistency reliability was .85 in the pre-test and .80 of post-test in terms of the cognitive function scale, and .90 of pre-test and .93 in the post-test in relation to the behavior observation scale. In conclusion, our analysis of the ACFS shows sufficiently high scores in terms of both validity and reliability, so as to indicate that this test is an appropriate way to measure the cognitive function and non-intellective function of young Korean children.