• Title/Summary/Keyword: test power

Search Result 10,130, Processing Time 0.044 seconds

Development of Automatic Resistance Measuring System for Aluminum Connector (금구류 히트사이클 시험용 자동 저항측정 시스템 개발)

  • Park, Sung-Kyun;Son, Hwa-Young;Ryu, Jae-Nam;Kim, Kyung-Hwan;Park, Byung-Rak;Park, Choong-Yeol;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.161-163
    • /
    • 1997
  • Heatcycle testing for aluminum connector is very important. But because of connecting or disconnecting the test circuit, measuring resistance is difficult. Also the previous measuring resistance instrument is analog type. So measuring method is difficult. And four measuring points for one test circuit cause difficulty in automation. In this paper we developed the automatic system for measuring resistance. Automation will allow more information to be gathered, which will lead to the connector aging process being better understood and controlled.

  • PDF

Study on the GOOSE Conformance Testing of IEC 61850 based IED (IEC 61850 대상 IED GOOSE 적합성 통신 시험에 관한 연구)

  • Jang, B.T.;Lee, N.H.;Kim, H.J.;Kim, B.H.;Shim, E.B.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.239-240
    • /
    • 2008
  • Korea Electric Power Research Institute has being carried out an IEC 61580 communication service test on IED trial products developed related to power IT project, "Development of Prototype for Advanced Substation Automation System based on the Digital Control Technology". This paper describes GOOSE testing, one of the IEC 61850 conformance testing items, which consists of 14 publish and subscribe test cases.

  • PDF

Method and implementation for reducing standby power consumption in intermediate capacity power supply with Power Line Communication (전력선통신기능 적용 중.대용량 전원공급장치의 대기전력 절감방법 및 구현)

  • Son, Do-Sun;Kim, Ki-Hyun;Kim, Sang-Cheol;Jeon, Eui-Seok;Lee, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1947-1948
    • /
    • 2008
  • This paper presents the implementation of Power Line Communication(PLC) module which can reduce standby-power consumption. The suggested PLC module consists of PLC modem, coupling circuit, ZCP(Zero-Cross Point) Circuit and main SMPS control relay. The test results under power line communication test-bed used home appliance show the 77% saving of standby-power.

  • PDF

A Study on the Verification of Electrical Power Subsystem for LEO Satellite (저궤도 위성의 전력시스템 검증에 관한 연구)

  • Park, Hee-Sung;Park, Sung-Woo;Jang, Jin-Bak;Jang, Sung-Soo;Lee, Sang-Kon
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.52-54
    • /
    • 2007
  • The LEO satellite generates the power during day and consumes the power during night, so the power changes repeatedly. The power fluctuation must be verified, because it affects the mission operation and lifetime of satellite. This study describes the test-set for verification of Electrical Power Subsystem and two verification items using it. The verification test of EPS will be useful to predict the mission lifetime and to decide the mission operation of satellite.

  • PDF

Spin Testing for the Endurance Verification of Gas Turbine Blades (고속회전시험기를 활용한 가스터빈 동익의 내구성 시험)

  • Lee, Dooyoung;Kim, Doosoo;Son, Taeha;Goo, Jaeryang
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2018
  • The long-term research and development for the production of domestic blades has been consistently performed. As the direct and indirect results of its nationwide technologies in precision casting have been improved as well as maintenance costs for turbine machinery has been reduced. Whereas, there are still not a few concerns about the reliability of newly manufactured blades in spite of the quality certificate in metallurgical and mechanical properties. A spin tester is a machine that gives centrifugal loading to a rotating part, and its practical application is the overspeed test that is usually used to check the quality of products. A new spin rig has been constructed in KEPCO Research Institute for the purpose of evaluating the reliability of blades. In this paper, the test methodology for low cycle fatigue damage mechanism as well as the overspeed test for newly developed blades is described, and their reliability is evaluated too.

A Steady-State Simulation and Experimental Study of Turboshaft Engine with Free Power Turbine (분리축방식 터보축 엔진의 정상상태 모사 및 실험연구)

  • 공창덕;기자영;고광웅
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.1 no.2
    • /
    • pp.84-90
    • /
    • 1997
  • The turboshaft engine with the free power turbine has been used for various purposes, for instance electric power generator, emergency power source, helicopter powerplant and so on. Steady-state simulation program was developed and experimental tests was carried out for comparing with computer simulation results. The test unit was composed of 1-stage centrifugal compressor, the can type combustor chamber, 1-stage radial type compressor turbine, and radial type free power turbine, and its output power is obtained from 3-phase AC generator. Main component characteristics which was used for the steady state simulation program, were obtained from the manufacturer of the test unit, and modified from experimental results of test unit. In comparison between computer simulation and experimental test results even though the test unit has the operational limit, deviation of component performance characteristics in simulation were within 6% range of experimental results.

  • PDF

Test Method of Communication Reliability based on HPGP between PEV and EVSE (전기차와 충전기 간 HPGP 기반 통신 신뢰성 테스트 방안)

  • Choi, Byeong-Gon;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.111-119
    • /
    • 2015
  • Smart Grid is a next-generation intelligent grid to optimize energy efficiency by integrating information and communication technologies to the existing power grid as a two-way exchange of information. HPGP communication standard for smart grid implementation has been developed for the emerging smart energy, home automation, electric vehicle communications applications. HPGP communication standard has the advantage of reducing cost and power consumption. Also, it can be interoperated with the previous HPAV communication standard. For the introduction of a new communication standard, the analysis of the reliability and interoperability verification is required. In this paper, we present sniffer test method as reliability test method about power line communication between PEV(Plug-in Electric Vehicle) and EVSE(Electric Vehicle Supply Equipment). Power line communication between PEV and EVSE is one of the most important Smart Gird applications. Also, we analyzed sniffer test results about power line communication based on HPGP between PEV and EVSE by using QCA7000 device, AVitar and Tool kit.

Intercomparisonn of Techniques for Pressure Tube Inspection of Pressurized heavy Water Reactor (가압 중수로형 원자력발전소 압력관 비파괴검사기술의 상호비교)

  • Lee, Hee-Jong;Kim, Yong-Si;Yoon, Byung-Sik;Lee, Young-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.4
    • /
    • pp.294-303
    • /
    • 2005
  • This paper describes the analysis results of a series f Round-Robin test that was performed to intercompare inspection and diagnosis techniques for characterization of pressure tube f a pressurized heavy water reactor under the Coordinated Research Project(CRP) of IAEA's nuclear Power Programme. For this test, six nations, Korea, Canada, India, Argentina, Rumania, and China that currently have pressurized heavy water reactors under operation involved, and the "KOR-1" pressure tube sample prepared by Korea was used. Two kinds of NDE technique, ultrasonic and eddy current test, were applied for these tests. The "KOR-1" pressure tube sample contains total 12 artificial flaws such as crack-like EDM notches, wear that is similar to the real flaws and can be produced on the pressure tubes during plant operation. Test results showed that seven laboratories from six nations detected all twelve flaws in "KOR-1" specimen by using ultrasonic and eddy current test methods, and ultrasonic test method was more accurate than eddy current test method in flaw detectin and sizing. ID flaws in pressure tube sample were more easily detected and accurately sized than OD flaws.

Changes of Corrective Astigmatism Values Depending on Position of Circle of Least Confusion in Astigmatic Refining Test Using Cross Cylinder (크로스실린더를 이용한 난시정밀검사에서 검사 전 최소착란원 위치에 따른 난시교정값의 변화)

  • Kim, Sang-Yeob;Lee, Min Jae;Lee, Kang Cheon;Lee, Tae Hui;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.349-354
    • /
    • 2015
  • Purpose: To investigate the changes of corrective values of astigmatism caused by the position of circle of least confusion on retina in refining astigmatic test using cross cylinder. Methods: 62 subjects (115 eyes) aged $22.24{\pm}2.48$ years participated for this study. After astigmatic test using a radial chart, refining test was performed using a cross cylinder in a condition of maximum plus to maximum visual acuity (MPMVA). Astigmatic refining test was repeatedly performed in each condition of which S+0.75 D, S+0.50 D, S+0.25 D, S-0.25 D, S-0.50 D, and S-0.75 D are added to spherical lenses of MPMVA. The measured values were compared with the values in MPMVA condition. Results: As compared with values in condition of MPMVA, change of astigmatic axis was increased with add the power of (+) spherical lenses and (-) spherical lenses. In same spherical condition, change of astigmatic axis was decreased with increment of astigmatic power (p<0.05). The corrective power of astigmatism was reduced with increment of (+) spherical lenses (p<0.05), and was raised with increment of (-) spherical lenses compared with the power in MPMVA condition. In case of adding (+) spherical lenses, difference of astigmatic power increased with increment of corrective astigmatism power in same test condition. Conclusions: In order to obtain a proper values for corrective astigmatism, position of circle of least confusion should be accurately adjusted before the performing an astigmatism's refining test.

Determination of No-Failure Test Times for the Life Test of Hydraulic System Components (유압시스템 구성품의 수명시험을 위한 무고장 시험시간의 산출)

  • Lee, S.R.;Kim, H.E.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.3
    • /
    • pp.8-13
    • /
    • 2006
  • It is very important for the manufacturers to predict the life of hydraulic system components according to the results of life tests. Since it takes too much time to test the hydraulic system components until failure, the no-failure test method is applied for the life test of them. If the shape parameter of Weibull distribution, the number of samples, the confidence level, and the assurance life are given, the no-failure test times of hydraulic system components can be calculated by given equation. Here, the procedures to obtain the no-failure test times of the hydraulic system components such as hydraulic motors and pumps, hydraulic cylinders, hydraulic valves, hydraulic accumulators, hydraulic hoses, and hydraulic filters are described briefly.

  • PDF