• Title/Summary/Keyword: test power

Search Result 10,130, Processing Time 0.044 seconds

Correlation of Executive Function and Quantitative Electroencephalography in Children and Adolescents with Attention-Deficit/Hyperactivity Disorder (주의력결핍 과잉행동장애 소아청소년의 실행기능과 정량화 뇌파의 상관성 연구)

  • Jeong, Yu-jin;Park, Jin Young;Kim, Hyunjung;Choi, Jungwon;Jhung, Kyungun
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.25 no.1
    • /
    • pp.63-72
    • /
    • 2017
  • Objectives : Attention-deficit hyperactivity disorder(ADHD) is characterized by significant impairments in executive functions, with a prevalence of approximately 3-5% of all children worldwide. The goal of this study was to examine the relationship between executive functions and electrophysiological activities in children and adolescents with ADHD. Methods : In 31 patients with ADHD, resting-state EEG was recorded, and Comprehensive Attention Test(CAT), Stroop Color-Word Inference Test(Stroop CWIT), Trail Making Test(TMT), and Wisconsin Card Sorting Test(CST) were administered. Korean version of the ADHD Rating Scale(K-ARS) was assessed. Results : Alpha and beta power positively correlated with the Attention Quotient(AQ), while delta power negatively correlated with AQ from CAT. In the Stroop CWIT, decreased delta power and increased beta power were related to higher performance. Power of the alpha band increased with higher TMT performance. Moreover, delta power negatively correlated with good performance on the CST, while alpha and high gamma band showed a positive correlation. Correlation with the parent-rating of ADHD symptoms showed a negative correlation between alpha power and higher scores on the K-ARS. Conclusions : These findings indicate that relative power in higher frequency bands of EEG is related to the higher executive function in children and adolescents with ADHD, while the association with the relative power in lower frequency bands of EEG seem to be vice versa. Furthermore, the findings suggest that QEEG may be a useful adjunctive tool in assessing patients with ADHD.

A Study on the Development of Abnormal Power Source Generator to Evaluate Electronic Appliances (시험용 이상전원(異狀電源) 발생장치의 개발에 관한 연구)

  • Park, Chan-Won;Rho, Jea-Kwan
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.83-90
    • /
    • 2004
  • Generally, electronic appliances are used on the basis of normal power source supply. The power source inevitably includes the abnormal condition, such as, sudden voltage sagging, power interrupt, and induced noises. As the electronic appliances which include micro-controller-based circuits are being increased recently, the controller circuit sometimes malfunctions by the abnormal condition of the power source. This situation causes serious problems such as hitch of electric appliance, fire and medical instrument glitch, which produces serious situations. In this paper, development of power interrupt tester which is highly suitable for an endurance test device under abnormal power source to microprocessor-based circuits is proposed 89C2051 microcontroller is performed to make power interrupt signal, and software controls peripheral hardwares and built-in functions. Experimental results of this study will offer a good application to electronic appliance maker as a test device of hardware and software debugging use.

  • PDF

An Experimental and Numerical Study of Corona in a Cage with Sandy and Dusty Flow in High Altitude Area

  • Lv, Yukun;Ge, Zekun;Liu, Yunpeng;Zhu, Lei;Wei, Shaoke
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1726-1733
    • /
    • 2015
  • In order to study the effect of the high-altitude and dusty weather in northwest of China on the corona characteristics of transmission lines, a corona caged based experimental system with sandy and dusty flow condition is numerically investigated and designed. This system overcomes the difficulties caused by harsh environment and offers easy usage for off-site tests. The design parameters are mainly determined by the characteristics of strong sandstorm in northwest region and test requirements. By the comparison of numerical simulation of the particle diffusion in four programs with rectangular or circular air-duct, a practical technology, which introduces swirl to control the particle diffusion length, is obtained. Accordingly, the structure of round air-duct with swirl elbow in inlet and outlet of high level segment is selected as final program. Systems of control and measurement are designed at the same time. Field tuning results show that the test system could ensure the range of sandy and dusty coverage. The wind speed, sandy and dusty concentration could be controlled and meet the requirements of accuracy. The experimental system has many features, such as simple structure, easy to be assembled, disassembled, transported and operated, small space occupied.

Model Test for Towing Stability and Seakeeping of a Multi-Purpose Mobile Base (해상풍력 일괄설치시스템 예인 안정성 및 내항성능 평가를 위한 모형시험)

  • Cho, Dong-Ho;Lee, Jun-Shin;Ryu, Moo-Sung;Jung, Min-Uk;Lee, Ho-Yeop;Han, Kwan-Woo;Kim, Seung-Han
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.2
    • /
    • pp.163-171
    • /
    • 2020
  • A model test for assessment of towing stability and seakeeping of a multi-purpose mobile base (MMB) was performed in calm water and wave conditions. Scale ratio of the MMB was 1/48. Tension of the towing line was measured during tests to estimate effective power to tow the full scale MMB. The tests were repeated with towing speed. In addition, an inertial measurement unit was used to measure six DOF motion of the model. Seakeeping performance was assessed through the captive model test.

A Test for Multivariate Normality Focused on Elliptical Symmetry Using Mahalanobis Distances

  • Park, Cheol-Yong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.17 no.4
    • /
    • pp.1191-1200
    • /
    • 2006
  • A chi-squared test of multivariate normality is suggested which is mainly focused on detecting deviations from elliptical symmetry. This test uses Mahalanobis distances of observations to have some power for deviations from multivariate normality. We derive the limiting distribution of the test statistic by a conditional limit theorem. A simulation study is conducted to study the accuracy of the limiting distribution in finite samples. Finally, we compare the power of our method with those of other popular tests of multivariate normality under two non-normal distributions.

  • PDF

A Test for Multivariate Normality Focused on Elliptical Symmetry Using Mahalanobis Distances

  • Park, Cheol-Yong
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.203-212
    • /
    • 2006
  • A chi-squared test of multivariate normality is suggested which is mainly focused on detecting deviations from elliptical symmetry. This test uses Mahalanobis distances of observations to have some power for deviations from multivariate normality. We derive the limiting distribution of the test statistic by a conditional limit theorem. A simulation study is conducted to study the accuracy of the limiting distribution in finite samples. Finally, we compare the power of our method with those of other popular tests of multivariate normality under two non-normal distributions.

  • PDF

Goodness-of-fit Test for Rayleigh Distribution

  • Sultan, K.S.
    • International Journal of Reliability and Applications
    • /
    • v.8 no.1
    • /
    • pp.41-51
    • /
    • 2007
  • In this paper, we use the moments of order statistics derived by Lieblein (1955) to develop the correlation goodness-of-fit test for the Rayleigh distribution. In such we simulate the percentage points of the test statistics for the one-parameter and two-parameter cases. In addition, we calculate the power of the proposed tests based on some alterative distributions. Finally, we apply the procedures developed in the paper to some real data.

  • PDF

Testing NBUCA Class of Life Distribution Using U-Test

  • Al-Nachawati, H.
    • International Journal of Reliability and Applications
    • /
    • v.8 no.2
    • /
    • pp.125-135
    • /
    • 2007
  • In this paper, testing exponentiality against new better than used in convex average and denote by (NBUCA), or its dual (NWUCA) is investigated through the U-test. The percentiles of these tests are tabulated for samples sizes n = 5(1)40. The power estimates of the test are simulated for some commonly used distributions in reliability. Pitman's asymptotic efficiency of the test is calculated and compared. Data of 40 patients suffering from blood cancer disease (Leukemia) is considered as a practical application of the proposed test in the medical sciences.

  • PDF

Application of Fault Current Limiter in 22.9kV KEPCO power distribution line (22.9kV 지중선로용 한류기 한전 실계통 시범적용)

  • Kim, Min Jee;Park, Kyungwon;Ahn, Kil-Young;Kim, Young-keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1034-1035
    • /
    • 2015
  • Watertight 25.8 kV/600 A/12.5 kA fault current limiters (FCLs) have successfully installed in five areas (Incheon, Seoul, Gyeong-gi, Daejeon, Suwon) on KEPCO power distribution line for the purpose of commercial demonstrations. The fault current limiting operation of this FCL, which includes functions of sensing, commutation, and reduction of fault currents, is perfectly completed within 1 cycle immediately after fault occurs. The performance of FCL was verified by short circuit test, impedance test, insulation test, temperature-rise test, and control test, etc at PT&T in LS industrial systems, which is the official certification institute in Korea. In 2013, and also the FCL field test was performed in order to test the protection coordination between conventional relays and FCL, on the 1.5 kA and 5.0 kA faults, which were made by connecting the Artificial Fault Generator (AFG) to the distribution line in test grid at KEPCO Power Testing Center. The next step of this project is to check the FCL conditions caused by real external environment, and acquire the various data from five regions installed with FCL. In this paper, we intend to explain the FCL specifications and performance characteristics, and check the expected effect by application of FCL to power distribution line based on the power system analysis of an application site.

  • PDF