• Title/Summary/Keyword: test plant

Search Result 3,792, Processing Time 0.035 seconds

Analysis of the Performance Test Results of a Heat Pump for Closed Cooling Water Heat Recovery on a Combined Thermal Power Plant (복합화력의 냉각수 배열회수를 위한 히트펌프의 성능평가 사례 분석)

  • Lee, Sung-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.541-546
    • /
    • 2014
  • The present study was conducted to determine whether ESCO Business is success or not. ESCO Business recovers the investment costs by the energy savings resulting from complementing existing energy facilities. The guaranteed parameters are Quantity of Heat Recovery, and Generator output drop. The results of the Performance Test show that the Quantity of Heat Recovery increased by 11.52 Gcal/h, and Generator output decreased by 0.234 MW, which satisfied the guarantee value.

A Study on the Heat Transfer in boiler through the performance test in thermal power plant (화력발전소 보일러내의 열전달에 관한 연구)

  • Kwon, Y.S.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2064-2069
    • /
    • 2004
  • The main reason to analyze heat transfer in boiler inside through the performance test in fossil power plant is to increase plant high efficiency and energy saving movement in the government. Tins study intends to have trend and analyze the boiler heat transfer through the performance test, so it may give us the heat distribution in boiler inside in super-critical and sub-critica1 pressure type power plant

  • PDF

Construction of Marine Small Hydro Power Plant using Discharge Water of Fish Farm (양어장 방류수를 이용한 해양소수력발전소 구축에 관한 연구)

  • Hwang, Yeong-Cheol;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.5
    • /
    • pp.11-17
    • /
    • 2013
  • This study is aimed to construct a marine small hydro power plant using discharge water of fish farm in Jeju Haengwon-ri. The difference of design methods between marine small hydro power plant and land small hydro power plant is to consider the tides. Moreover, ground condition should be examined because gushout sea water comes out from the ground at high tide in Jeju as the ground of Jeju beach consists of basalt stone. From the field test of the turbine generator after construction of the power plant, output power and efficiency of the turbine generator shows good conformance to the required conditions.

Identification of Three-Parameter Models from Step Response (스텝응답을 이용한 3매개변수 모델의 식별)

  • Ali, Mohammed Sowket;Lee, Jun-Sung;Lee, Young-Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.12
    • /
    • pp.1189-1196
    • /
    • 2010
  • This paper provides an identification method for three-parameter models i.e. first order with dead time models and second order with dead time models. The proposed identification method is based on step response and can be easily implemented using digital microprocessors. The proposed method first identifies the order of the plant i.e. first order or second order from the behavior of the plant with constant input. After the order of the plant is determined, a test step input is applied to the system and the three parameters of the plant are obtained from the corresponding response of the plant. The output of the plant need not to be zero when the test signal is applied. The efficacy of proposed algorithms is verified through simulation and experiment.

Protective Effect of Korean Medicinal Plants on Ethanol-Induced Cytotoxicity in HepG2 Cells

  • Song, Eun Jeong;Kim, Nam Yee;Heo, Moon Young
    • Natural Product Sciences
    • /
    • v.19 no.4
    • /
    • pp.329-336
    • /
    • 2013
  • The purpose of this study is to evaluate cytoprotective effect of Korean medicinal plants on alcohol-induced cytotoxicity in liver cells. Out of the 120 plant extracts tested in this study, 53 plant extracts enhanced alcohol-induced cytotoxicity in liver cells by 50~80%, while other 11 plant extracts including Crataegus pinnatifida reduced cytotoxicity by 1~68%. The results of DPPH free radical test and LDL lipid peroxidation test on the plant extracts that sharply reduced cytotoxicity in liver cells shows that Crataegus pinnatifida and Cinnamomum cassia had antioxidative effect. This study reports that the plant extracts that enhance or reduce ethanol-induced cytotoxicity in liver cells can be research objects as cytotoxic plants or cytotoxicity-protective plants.

Evaluation of Degraded Materials by Automated Ball Indentation(ABI) Technique (압입법을 이용한 재료의 열화도 평가)

  • 김석민;석창성;이승석;권재도
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.28-35
    • /
    • 2000
  • As huge energy transfer systems like a nuclear power plant, steam power plant and petrochemical plant are operated for a long time, mechanical properties are changed by degradation. The life time of the systems can be affected by the mechanical properties. So determination of the integrity of the metallic structure is required either to en4sure that failure will not occur during the service life of the components or to evaluate the lifetime extension of the structure. An automated ball indentation(ABI) method was developed as a non-destructive technique for evaluating the integrity of such metallic components. In this paper, we would like to present the aging evaluation technique by the ABI method. The five classes of the thermally aged CF8M specimens were prepared using an artificially accelerated aging method. After holding 100, 300, 900, 1800 and 3600 hours at 43$0^{\circ}C$, the specimens were cooled down using water to room temperature respectively. The tensile test, hardness test, charpy impact test, ABI test were performed. The results of the fracture test were compared with those of ABI test and the new evaluation technique of the integrity of metallic structures was developed.

  • PDF

SNP Marker Development for Purity Test of Oriental Melon and Melon (멜론 및 참외 순도 검정을 위한 SNP 마커 개발 및 F1 종자 순도 검정)

  • An, Song-Ji;Kwon, Jin-Kyung;Yang, Hee-Bum;Choi, Hye-Jeong;Jeong, Hee-Jin;Kim, Yong-Jae;Choi, Gyung-Ja;Kang, Byoung-Cheorl
    • Korean Journal of Breeding Science
    • /
    • v.42 no.4
    • /
    • pp.397-406
    • /
    • 2010
  • Field screening method has been commonly used for purity test of $F_1$ hybrid seeds in melon and oriental melon. However, as this method takes a lot of time and cost, molecular marker-based purity test is necessary. To develop molecular markers for purity test, thirty pairs of SNP (single nucleotide polymorphism) primers were obtained from melon EST sequences, and 10 polymorphic markers showing HRM (high resolution melting) polymorphisms between parents of two melon cultivars and one oriental melon cultivar were selected. Blind tests were performed to validate usefulness of the selected markers for purity test. Blind test results showed that HRM genotypes were matched with the expected identity of individual sample, $F_1$ hybrid, male or female parents. Three HRM-based SNP markers were converted to CAPS markers for general use which is favor to breeders. We expect that SNP markers developed in this study will be useful for purity test of $F_1$ hybrid seeds in melon and oriental melon.

A Study of Automation for Examination Analysis of Inservice Inspection for Nuclear Power Plant (I) (원자력발전소(原子力發電所) 가동중(稼動中) 검사(檢査)의 시험분석(試驗分析)을 위한 자동화연구(自動化硏究) (I))

  • Kim, W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.5 no.1
    • /
    • pp.34-47
    • /
    • 1985
  • The developing country, KOREA where does not possess the natural resources for traditional energy such as oil and gas, so. The nuclear energy is the most single reliable source available for closing the energy gap. For these reason, It is inavoidable to construct the nuclear power plant and to develop technology related nuclear energy. The rate of operation in large nuclear power facilities depends upon the performance of work system through design and construction, and also the applied technology. Especially, it is the most important element that safety and reliability in operation of nuclear power plant. In view of this aspects, Nuclear power plant is performed severe examinations during preservice and inservice inspection. This study provide an automation of analysis for volumetric examination which is required to nuclear power plant components. It is composed as follows: I. Introduction II. Inservice Inspection of Nuclear Power Plant ${\ast}$ General Requirement. ${\ast}$ Principle and Methods of Ultrasonic Test. ${\ast}$ Study of Flaw Evaluation and Design of Classifying Formula for Flaws. III. Design of Automation for Flaw Evaluation. IV. An Example V. Conclusion In this theory, It is classifying the flaws, the formula of classifying flaws and the design of automation that is the main important point. As motioned the above, Owing to such as automatic design, more time could be allocated to practical test than that of evaluation of defects, Protecting against subjective bias tester by himself and miscalculation by dint of various process of computation. For the more, adopting this method would be used to more retaining for many test data and comparative evaluating during successive inspection intervals. Inspite of limitation for testing method and required application to test components, it provide useful application to flow evaluation for volumetric examination. Owing to the characteristics of nuclear power plant that is highly skill intensive industry and has huze system, the more notice should be concentrated as follows. Establishing rational operation plan, developing various technology, and making the newly designed system for undeveloped sector.

  • PDF

Analysis of Agricultural Characters to Establish the Evaluating Protocol and Standard Assessment for Genetically Modified Peppers (GM 고추의 환경위해성 평가 프로토콜 작성을 위한 농업적 형질 분석)

  • Cho, Dong-Wook;Chung, Kyu-Hwan
    • Journal of Environmental Science International
    • /
    • v.20 no.9
    • /
    • pp.1183-1190
    • /
    • 2011
  • This study was aimed to establish the evaluating protocol and standard assessment for genetically modified (GM) hot pepper and to find out a proper statistic method to analyze for equality of agricultural characters between GM and non-GM pepper lines. GM and non-GM hot pepper lines were cultivated in two GMO fields in the middle region of Korea and total of 52 agricultural characters were collected during the plant growing season for 4 years, 2007 to 2010. Levene's test was conducted to confirm the homogeneity of raw data before statistic analysis. Two-way ANOVA in the multivariate tests and t-test were conducted to analyze 52 agricultural characters in order to find out the equality between H15 and P2377. From the statistical analysis through two-way ANOVA, 16 out of 16 plant growth traits, 9 out of 18 green fruit traits and 7 out of 18 red fruit traits among 4 years and 9 out of 16 plant growth traits, 4 out of 18 green fruit traits and 3 out of 18 red fruit traits between H15 and P2377 have shown the statistic differences. With the same raw data of 52 agricultural characters, t-test was also conducted. Based on the result from t-test, only 1 out of 16 plant growth traits, 2 out of 18 green fruit traits and 1 out of 18 red fruit traits have shown the differences between H15 and P2377, so that it was concluded that there is no statistic difference between H15 and P2377 in terms of agricultural characters. Also, the t-test is a proper statistic method to analyze each trait between GM and its control lines in order to evaluate agricultural characters.

Procedure and Method of Equipment Qualification for Solenoid-Operated Valves Used in Nuclear Power Plants (원전용 솔레노이드 밸브의 기기검증 절차 및 방법)

  • Lim, Byung-Ju;Park, Chang-Dae;Chung, Kyung-Yul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.6
    • /
    • pp.683-691
    • /
    • 2011
  • In order to develop technology for an equipment qualification (EQ) test, which is an important process in localizing solenoid-operated valves used in nuclear power plants, we analyzed related regulations, test procedures, conditions, equipment, and acceptance criteria. EQ regulations for the solenoid-operated valve are classified as law, guide, and standard, and are subdivided according to test specimens and contents. The EQ test is composed of functional, normal-, and accident- condition tests. The solenoid-operated valve is aged under normal and accident conditions, which are predicted in the design conditions of a nuclear power plant, and the performance of the valve is measured by a functional test. The test method and procedure analyzed in this paper might be very useful for manufacturers as well as EQ testers.