• 제목/요약/키워드: test methods

검색결과 27,526건 처리시간 0.062초

시험 비트열을 이용한 MPEG-4 텍스처 디코딩의 정적 Conformance Test (Static Conformance Test of MPEG-4 Visual Decoders Using Test Bitstreams)

  • 김우식;박인수;박수현;이병욱;박래홍
    • 대한전자공학회논문지SP
    • /
    • 제38권1호
    • /
    • pp.69-78
    • /
    • 2001
  • MPEG-4 비주얼 conformance test는 비트열과 디코더가 주어진 프로파일과 레벨의 표준을 정확히 따르는 가를 시험하는 것이다. 디코더 시험에는 정적 시험과 동적 시험이 있는데 이중에서 정적 시험은 시험 비트열을 제작하여 제작된 디코더에서 복원된 영상과 참조 디코더에서 복원된 영상을 비교하여 수행할 수 있다. 본 논문에서는 텍스처 디코딩 부분의 정적 시험을 위한 시험 비트열을 제작하여 conformance test를 수행하는 과정을 보이고 그 결과를 보였다.

  • PDF

Cyclic fatigue resistance tests of Nickel-Titanium rotary files using simulated canal and weight loading conditions

  • Cho, Ok-In;Versluis, Antheunis;Cheung, Gary S.P.;Ha, Jung-Hong;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제38권1호
    • /
    • pp.31-35
    • /
    • 2013
  • Objectives: This study compared the cyclic fatigue resistance of nickel-titanium (NiTi) files obtained in a conventional test using a simulated canal with a newly developed method that allows the application of constant fatigue load conditions. Materials and Methods: ProFile and K3 files of #25/.06, #30/.06, and #40/.04 were selected. Two types of testing devices were built to test their fatigue performance. The first (conventional) device prescribed curvature inside a simulated canal (C-test), the second new device exerted a constant load (L-test) whilst allowing any resulting curvature. Ten new instruments of each size and brand were tested with each device. The files were rotated until fracture and the number of cycles to failure (NCF) was determined. The NCF were subjected to one-way ANOVA and Duncan's post-hoc test for each method. Spearman's rank correlation coefficient was computed to examine any association between methods. Results: Spearman's rank correlation coefficient (${\rho}$ = -0.905) showed a significant negative correlation between methods. Groups with significant difference after the L-test divided into 4 clusters, whilst the C-test gave just 2 clusters. From the L-test, considering the negative correlation of NCF, K3 gave a significantly lower fatigue resistance than ProFile as in the C-test. K3 #30/.06 showed a lower fatigue resistance than K3 #25/.06, which was not found by the C-test. Variation in fatigue test methodology resulted in different cyclic fatigue resistance rankings for various NiTi files. Conclusions: The new methodology standardized the load during fatigue testing, allowing determination fatigue behavior under constant load conditions.

콘크리트 직접인장강도의 세장비 효과 (Effect of Aspect Ratio in Direct Tensile Strength of Concrete)

  • 홍건호
    • 콘크리트학회논문집
    • /
    • 제15권2호
    • /
    • pp.246-253
    • /
    • 2003
  • 콘크리트 부재는 직접 인장력에 저항하도록 설계되지는 않는 것이 일반적이나, 부재의 균열강도 등을 산정하기 위해서는 반드시 확인하여야 하는 재료 특성 중의 하나이다. 콘크리트의 인장강도 시험방법은 주로 직접인장, 휨인장, 쪼갬인장의 3가지로 구분하고 있으나, 이 중 직접인장시험법은 시험체에 순수인장력을 가력할 수 있는 실험방법상의 문제로 거의 수행되지 못하여 온 것이 사실이다. 본 연구에서는 직접인장시험방법의 검토 및 시험체의 세장비, 크기 등이 직접인장강도에 미치는 영향에 대하여 연구하였다. 단부 보강편을 이용한 직접인장강도의 실험은 RILEM 및 U.S.Bureau of Reclamation의 규정을 사용하였으며, 총 4가지 종류의 세장비와 2가지 크기의 시험체에 대한 연구를 수행하였다. 실험의 결과는 동일변수의 쪼갬인장강도 및 휨인장강도와 비교$.$분석을 실시하였으며, 이를 신뢰성있는 선행 연구자들의 연구결과와 비교하여 그 타당성을 검증하였다.

Stability Test and Quantitative and Qualitative Analyses of the Amino Acids in Pharmacopuncture Extracted from Scolopendra subspinipes mutilans

  • Cho, GyeYoon;Han, KyuChul;Yoon, JinYoung
    • 대한약침학회지
    • /
    • 제18권1호
    • /
    • pp.44-55
    • /
    • 2015
  • Objectives: Scolopendra subspinipes mutilans (S. subspinipes mutilans) is known as a traditional medicine and includes various amino acids, peptides and proteins. The amino acids in the pharmacopuncture extracted from S. subspinipes mutilans by using derivatization methods were analyzed quantitatively and qualitatively by using high performance liquid chromatography (HPLC) over a 12 month period to confirm its stability. Methods: Amino acids of pharmacopuncture extracted from S. subspinipes mutilans were derived by using O-phthaldialdehyde (OPA) & 9-fluorenyl methoxy carbonyl chloride (FMOC) reagent and were analyzed using HPLC. The amino acids were detected by using a diode array detector (DAD) and a fluorescence detector (FLD) to compare a mixed amino acid standard (STD) to the pharmacopuncture from centipedes. The stability tests on the pharmacopuncture from centipedes were done using HPLC for three conditions: a room temperature test chamber, an acceleration test chamber, and a cold test chamber. Results: The pharmacopuncture from centipedes was prepared by using the method of the Korean Pharmacopuncture Institute (KPI) and through quantitative analyses was shown to contain 9 amino acids of the 16 amino acids in the mixed amino acid STD. The amounts of the amino acids in the pharmacopuncture from centipedes were 34.37 ppm of aspartate, 123.72 ppm of arginine, 170.63 ppm of alanine, 59.55 ppm of leucine and 57 ppm of lysine. The relative standard deviation (RSD %) results for the pharmacopuncture from centipedes had a maximum value of 14.95% and minimum value of 1.795% on the room temperature test chamber, the acceleration test chamber and the cold test chamber stability tests. Conclusion: Stability tests on and quantitative and qualitative analyses of the amino acids in the pharmacopuncture extracted from centipedes by using derivatization methods were performed by using HPLC. Through research, we hope to determine the relationship between time and the concentrations of the amino acids in the pharmacopuncture extracted from centipedes.

종양 이질성을 검정을 위한 통계적 방법론 연구 (Statistical methods for testing tumor heterogeneity)

  • 이동녘;임창원
    • 응용통계연구
    • /
    • 제32권3호
    • /
    • pp.331-348
    • /
    • 2019
  • 전이성 종양의 성장패턴 차이와 변화율에 따른 종양 이질성(tumor heterogeneity)을 파악하는 것은 종양세포의 약물에 대한 민감성을 파악하고 적절한 치료법을 찾아내기 위해 중요하다. 일반적으로 N개의 표본의 집단이 구분된다면 t-test 혹은 ANOVA 분석을 통해 집단별 평균의 차이에 대한 검정이 가능하다. 그러나 본 논문에서 다루는 데이터와 같이 집단이 구분되지 않는 경우 이러한 방법들은 사용될 수 없다. 표본들 사이의 이질성을 검정하기 위한 통계적 방법들이 연구되어 왔다. 최소 조합 t-검정 방법은 그 중 하나이다. 본 논문에서는 상이한 비율로 데이터를 양분하는 조합도 고려하는 최대 조합 t-검정 방법을 제안한다. 한편, 표본의 이질성을 검정하는 것이 군집분석에서 최적의 군집의 개수가 2개 이상인지를 검정하는 것과 같음에 착안하여 새로운 방법을 제안한다. 최대 조합 t-검정과 gap통계량을 이용하면 이전에 제안된 방법보다 개선된 제1종의 오류를 범할 확률과 검정력을 갖는다는 것을 모의실험을 통해 확인하였고 실제 자료 분석을 통해 결과를 도출하였다.

Bootstrap Tests for the General Two-Sample Problem

  • 조길호;정성화
    • Journal of the Korean Data and Information Science Society
    • /
    • 제13권1호
    • /
    • pp.129-137
    • /
    • 2002
  • Two-sample problem is frequently discussed problem in statistics. In this paper we consider the hypothese methods for the general two-sample problem and suggest the bootstrap methods. And we show that the modified Kolmogorov-Smirnov test is more efficient than the Kolmogorov-Smirnov test.

  • PDF

Test Chart 2000 Pro와 한국 표준 검안법의 일치도 비교 연구 (A Comparative Study between Korean Standard Eye Test and Test Chart 2000 Pro)

  • 강지훈;김달영
    • 한국안광학회지
    • /
    • 제14권1호
    • /
    • pp.69-80
    • /
    • 2009
  • 목적: 본 연구는 영국에서 개발된 컴퓨터 모니터용 검안프로그램 Test Chart 2000 Pro의 타당도(validity)를 평가하기 위해 수행되었다. 방법: Test Chart 2000 Pro와 한국표준검안법의 공통된 10종류 검안항목에 대하여, 각 항목별로 동일한 피실험자군을 대상으로 2가지 검안법을 함께 실시하고, 측정결과의 일치도를 비교분석하였다. 결과: 10종류의 비교실험 중 Snellen Chart, Cross-cyl Target, Duochrome Test, Fan and Block Test, Random Dot Stereograms에서는 한국표준검안법과 Test Chart 2000 Pro양측의 결과가 통계적으로 유의미한 일치를 보였으나, LogMar Chart, Single Letter Chart, Phoria Test, Fixation Disparity Test, Worth 4 Dot Test에서는 두 검안 방법의 결과에서 차이가 나타났다. 결론: 한천석 시력표와 포롭터로 이루어진 한국표준검안법을 기준으로 했을 때 Test Chart 2000 Pro의 타당도는 높지 않으며, 측정의 정확도 측면에서 개선이 요구된다.

  • PDF

S파를 이용한 지하공동 탐사의 모형 연구 (Model Study for Underground Cavity Detection Using S-wave)

  • 서백수
    • 터널과지하공간
    • /
    • 제3권2호
    • /
    • pp.109-117
    • /
    • 1993
  • The existence and exact location of cavity is very important for the stability of the large underground storage house or building. Numerical method such as finite element method and finite diference methods are widely used because of model's complexity. Preliminary tests such as calculation step test, mesh size test and model size test were tried. Upper shadow zone and lower shadow zone can be calculated from 50% amplitude level of measuring data. From these statistical methods, the calculatied position of cavity coincided nearly with actual position of model testing cavity.

  • PDF

The Comparative Power Evaluation of Parametric Versus Nonparametric Methods

  • Choi, Young-Hun
    • Communications for Statistical Applications and Methods
    • /
    • 제3권3호
    • /
    • pp.283-290
    • /
    • 1996
  • The simulation study shows that the rank transform test has relatively superior power advantages over the parametric analysis of variance test in many cases for a $2^3$ factorial design, particularly with heavy-tailed distributions of the error terms. However the rank transform test should be cautiously used when all main effects and interactions related to a testing effect are possibly present at the same time.

  • PDF