• Title/Summary/Keyword: test coil

Search Result 507, Processing Time 0.024 seconds

Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner (임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발)

  • Kim, Eun Ju;Kim, Daehong;Lee, Sangwoo;Heo, Dan;Lee, Young Han;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2014
  • Purpose : To establish a pH measurement system for a mouse tumor study using a clinical scanner, to develop the $^1H$ and 31P radio frequency (RF) coil system and to test pH accuracy with phantoms. Materials and Methods: The $^1H$ and the $^{31}P$ surface coils were designed to acquire signals from mouse tumors. Two coils were positioned orthogonally for geometric decoupling. The pH values of various pH phantoms were calculated using the $^1H$ decoupled $^{31}P$ MR spectrum with the Henderson-Hasselbalch equation. The calculated pH value was compared to that of a pH meter. Results: The mutual coil coupling was shown in a standard $S_{12}$. Coil coupling ($S_{12}$) were -73.0 and -62.3 dB respectively. The signal-to-noise ratio (SNR) obtained from the homogeneous phantom $^1H$ image was greater than 300. The high resolution in vivo mice images were acquired using a $^{31}P$-decoupled $^1H$ coil. The pH values calculated from the $^1H$-decoupled $^{31}P$ spectrum correlated well with the values measured by pH meter ($R^2$=0.97). Conclusion: Accurate pH values can be acquired using a $^1H$-decoupled $^{31}P$ RF coil with a clinical scanner. This two-surface coil system could be applied to other nuclear MRS or MRI.

Short-term Run and Short-circuit Test of 6.6㎸/200A DC reactor Type Superconducting Fault Current Limiter (6.6㎸/200A급 DC 리액터헝 초전도한류기의 단시간운전 및 단락시험)

  • 안민철;이승제;강형구;배덕권;윤용수;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.10-13
    • /
    • 2003
  • 6.6㎸rms/200Arms DC reactor type superconducting fault current limiter (SFCL) has been developed. This paper deals with the manufacture and short-circuit test of the SFCL. DC reactor was the HTS solenoid coil whose inductance was 84mH. AC/DC power converter was performed as the dual-mode operation. The short-term run(1 sec) and short-circuit test of this SFCL was performed successfully. The experimental results have a similar tendency to the simulation results. In short-circuit test, at 2 cycles after the fault, fault current limitation rate was about 30%.

  • PDF

Insulating Design and Test of 22.9kV Class Mini-Model Transformer Considering AC Loss (AC Loss를 고려한 22.9kV급 Mini-Model 변압기의 절연 설계 및 시험)

  • 백승명;정종만;곽동순;김해종;석복렬;김상현
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.8
    • /
    • pp.420-424
    • /
    • 2004
  • This paper presents experimental data from model windings with different arrangement of coil in order to provide information to design a 22.9kV class HTS transformer. Before experiment, the composite insulation of two different type of HTS transformers are investigated. The first basic of investigation is a breakdown characteristic of liquid nitrogen and flashover characteristic on the GFRP surface under ac and impulse, The second investigation is insulation design, manufacture and test of model windings. These include a AC withstand voltage test of 50 kV rms and a lighting impulse test of 150 kV at peak.

Performance Evaluation of Class I SPD Using $10/350{\mu}s$ Surge Current ($10/350{\mu}s$ 서지전류를 이용한 I 등급 SPD의 성능평가)

  • Cho, Sung-Chul;Eom, Ju-Hong;Lee, Tae-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1466-1467
    • /
    • 2007
  • A new parameter W/R for the class I test have been introduced in the IEC 61643-1 published in 2005. One of the possible test impulses which meets the parameters for class I test is the 10/350 [${\mu}s$] waveshape proposed in IEC61312-1. 10/350 [${\mu}s$] waveshape meets parameters for class I test in the IEC 61643-1. The impulse generator for making the 10/350 [${\mu}s$] waveshape is consist of IVG, ICG, crowbar coil and crowbar switch. The electric change Q and the specific energy W/R were measured and calculated using the exclusive use measuring software according to the formula of IEC 611643-1. We verified the correspondence between measured results using impulse generator and recommended parameters by IEC 61643-1.

  • PDF

Clopidogrel Response Variability in Unruptured Intracranial Aneurysm Patients Treated with Stent-Assisted Endovascular Coil Embolization : Is Follow-Up Clopidogrel Response Test Necessary?

  • Kim, Min Soo;Park, Eun Suk;Park, Jun Bum;Lyo, In Uk;Sim, Hong Bo;Kwon, Soon Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.2
    • /
    • pp.201-211
    • /
    • 2018
  • Objective : The purpose of this study was to analyze the variability of clopidogrel responses according to duration of a clopidogrel drug regimen after stent-assisted coil embolization (SAC), and to determine the correlation between the variability of clopidogrel responses and thromboembolic or hemorrhagic complications. Methods : A total of 47 patients who underwent SAC procedures to treat unruptured intracranial aneurysms were enrolled in the study. Preoperatively, patients received more than seven days of aspirin (100 mg) and clopidogrel (75 mg), daily. P2Y12 reaction unit (PRU) was checked with the VerifyNow test one day before the procedure (pre-PRU) and one month after the procedure (post-PRU). PRU variability was calculated as the difference between the initial response and the follow-up response. Patients were sorted into two groups based on their response to treatment : responsive and hypo-responsive. Results : PRU variability was significantly greater in the hypo-responsive group when compared to the responsive group (p=0.019). Pre-PRU and serum platelets counts were significantly correlated with PRU variation (p=0.005 and p=0.004, respectively). Although thromboembolic complication had no significant correlated factors, hemorrhagic complication was correlated with pre-PRU (p=0.033). Conclusion : In conclusion, variability of clopidogrel responses during clopidogrel medication was correlated to serum platelet counts and the initial clopidogrel response. Thromboembolic and hemorrhagic complications did not show correlation with the variability of clopidogrel response, or the clopidogrel response after one month of medication; however, hemorrhagic complication was associated with initial clopidogrel response. Therefore, it is recommended to test patients for an initial clopidogrel response only, as further tests would be insignificant.

Design of the Fittest Eddy Current Probe for the Fin Tubes (Fin 튜브의 와전류탐상을 위한 최적 탐촉자의 설계)

  • Kim, Y.J.;Lee, S.K.;Ahn, B.Y.;Chung, M.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.3
    • /
    • pp.156-161
    • /
    • 1997
  • The eddy current probe was designed for the test of fin tubes that have uneven outer and inner surfaces to enhance the efficiency of heat emission. Because of the surface roughness of the fin tube, it needs much care to detect flaws in the tube employing eddy current test(ECT). We made ECT probes with different coil lengths and performed eddy current test using these probes for artificially flawed specimens. By the fast Fourier transform and digital filtering, signals from these probes were processed to characterize frequency spectra. From the analysis of eddy current signals and their frequency spectra, we concluded that, for the effective testing of the tubes with the fins of 1mm pitch, 4mm coil length gave the highest S/N ratio.

  • PDF

Development of Active Suspension System for Wheelchairs to Improve Riding Comfort of Gait Disorders (보행 장애인의 승차감 개선을 위한 휠체어용 능동형 서스펜션 시스템 개발)

  • Heo, Yeong Jun;Jeon, Geum Sang;Lee, Sang Hun;Choi, Seong Dae;Jang, Ik Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.203-209
    • /
    • 2020
  • As the number of people with gait disorders increases, the demand for using wheelchairs increases and the area of a ctivity for people with disabilities expands, thereby they increasing the demand for riding comfortability in various driving environments. Therefore, this study is to develop an entry-level active suspension system that apply to wheelchairs and to evaluate its usability. The suspension applied in this paper consists of a coil spring, a shock absorber, a control module to control the strength of the shock absorber, and a road surface condition monitoring system. A wheelchair occupant secures the riding comfort by adjusting the coil strength of the shock absorber in 12 steps according to various road conditions. Therefore, the mechanical properties were evaluated through the structural analysis of the suspension system, and the tendency toward the magnitude of the road surface vibration attenuated according to the rigidity of the suspension through the vibration test was attempted. In conclusion, as a result of structural analysis of the suspension system, stress in a range lower than the yield strength of the material was generated, and the vibration test showed the effect of attenuating the vibration generated from the road surface when the stiffness of the suspension was adjusted.

Shaking Table Test of Isolated EDG Model (면진된 모형 비상디젤발전기의 지진응답 실험)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.33-42
    • /
    • 2007
  • In this study, for research on an improvement of the seismic safety of an EDG system, a small scale EDG system was manufactured. For the isolation system, the Coil Spring-Viscous Damper systems were selected. For the shaking table test, 3 kinds of seismic motions were selected which had different frequency contents. In this study, the isolation effects were different and they depended on the input seismic motion. In the case of an NRC earthquake which had low fiequency contents, the isolation effects of the horizontal direction were 20%. But for the seismic motions which had high fiequency contents, the isolation effects were $50{\sim}70%$. In the case of the vertical direction, poor isolation effects were observed. It was because the design properties and the real properties of the isolation system were a little different.

Sptimum Design of a Uniform Magnetic Field Exposure System for a Small-Sized Animal Study (자계 균일 공간 확보를 위한 소동물 실험용 5G급 자계 발생장치의 최적 설계)

  • 김상범;추장희;이동일;명성호
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.7
    • /
    • pp.1194-1203
    • /
    • 2000
  • A magnetic field exposure system that generates 60 Hz magnetic fields from 1 mG to 5 G was designed and constructed for small-sized animal study. In order to investigate as many animals as possible at one series of test, uniform magnetic fields are required at wide living area of the animals. In this article, a cubic shaped field exposure system with three animal living floors was designed, which offers about 50 seating capacity. For calculation of magnetic fields inside the cage, a three-dimensional calculation program was developed. Using this, optimum electric current ratio of inner coil to outer coil and position of each coil were determined. Meanwhile, inductance of the exposure system was calculated for the design of power supply. The field measurement results of the manufactured exposure system showed that the difference between maximum and minimum magnetic field at the testing floors was less than 3%, which strongly demonstrated the field exposure system was good for small sized animal study.

  • PDF

A Study of Rotor Fault Detection for the Induction Motor Using Axial Leakage Magnetic Flux (축방향 누설자속 측정에 의한 유도전동기의 회전자 결함검출에 관한 연구)

  • Shin, Dae-Cheul;Kim, Young-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.132-137
    • /
    • 2006
  • The second part of paper related rotor failure is to evaluate that the axial magnetic flux measurement could be used as a tool of the condition monitoring system for the induction motor and to develope the diagnostic algorithm for the various fault in the electric motors. The magnetic leakage flux signal is captured by the flux coil located at the end of motor without the disturbance of the operation. And the signal is analyzed both time and frequency domain to detect the failure of the motor. Specific signature can be described in tin and frequency domain for each fault of the motor. The experimental test found that the rotor failures - broken rotor bar, broken end ing and rotor eccentricity, could be detected from the spectrum with high resolution. The method of detecting the rotor fault was found by analysing the specific frequency and the sideband of the rotor bar pass frequency from axial leakage flux spectrum. In addition the optimal flux coil and measuring equipment for the axial leakage flux measurement was verified and the diagnostic method for the detection of the rotor related failure was developed.