A Fault Simulation Method Based on Primary Output (근본 출력에 근거한 고장 모의실험)

  • 이상설;박규호
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.6
    • /
    • pp.63-70
    • /
    • 1994
  • In this paper, we propose a fault simulation method based on primary output in combinational circuit. In the deterministic test pattern generation, each test pattern is genterated incrementally. The test pattern is applied to the primary inputs of circuit under test to simulate faults. We detect the faults with respect to each primary output. The fault detection with resptect to each primary output is reflected by the corresponding bit in the detection words, and efficient fault detection for the reconvergent fan-out stem is achieved with dynamic fault propagation. As an experimental result of the fault simulation with our method for the several bench mark circuits, we illustrated the good performance showing that the number of gates to be activated is much reduced as compared with other method which is not based on primary output.

  • PDF

Improved Synthetic Test Circuit for HVDC Valve Operational Test (HVDC Valve Operational Test를 위한 개선된 합성시험회로)

  • Kwon, Jun Bum;Baek, Seung Taek;Lee, Wook Hwa;Chung, Yong Ho
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.518-519
    • /
    • 2013
  • 신재생 에너지의 용량이 증대하고, 수요가 늘어 남에 따라, 국가 간, 도시 간의 송전이 중요한 이슈로 대두 되고 있으며, 해당 요구 조건을 만족시키기 위해서 초고압 직류 송전 개발이 요구 되고 있다. 이 초고압 직류송전(HVDC)에는 전류형과 전압형으로 나뉘게 되는데, 각 HVDC 에서 사용되는 Valve는 실제 운전 전에 여러 가지 방법으로 검증이 되어야 한다. 합성 시험회로(Synthetic Test Circuit = 이하 STC) 는 전류형 HVDC에서 사용되는 주요 전력변환 장치 인, Thyristor Valve의 동작을 실제 동작 조건에 맞추어 동작을 시켜, 동작의 신뢰성을 검증하는 시험 설비 이다. 기존 STC는 고전압 대전류 회로와 고전압 저전류 회로의 합성 동작으로 Thyristor Valve의 동작을 검증한다. 하지만 제안된 Topology를 이용하면, 고전압 대전류 회로를 저전압 대전류 회로로 사용할 수 있으며, 제작 비용 및 설치 면적 등을 감소 시킬 수 있어 경제적이다.

  • PDF

Environmental effects by corona discharge from a 765kV double circuit transmission line (765kV 2회선 송전선의 코로나 방전에 의한 환경영향 연구)

  • 김정부;이동일;신구용;양광호;안희성;구자윤
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.451-455
    • /
    • 1996
  • This paper specified the measurement results conducted by the Korea Electric Power Research Institute (KEPRI) 765kV double circuit transmission test line that measured the audible noise, hum noise, radio interference, electric field and aeolian measurement. This test line consists of 6-480mm$^{2}$ conductors per phase. The analysis of the test results shows that this 6-Rail conductor bundle satisfies the audible noise criterion under the stable rainy weather condition and the radio interference level under the fair weather. And the other items are also agreed with the design level criterion. (author). 9 refs., 7 figs., 2 tabs.

  • PDF

Analysis of Electrical Safety Level Test for Barehand Work at 765kV Vertical Double Circuit Six Bundle Conductors on the Suspension String Tower Type (765kV 수직2회선 6도체 현수형 철탑에서 직접활선작업의 안전성 평가분석)

  • Kim, Dae-Sik;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.275-278
    • /
    • 2008
  • It has been issued that the necessity of Live line work for 765kV vertical double circuit six bundle conductors transmission line when the characteristics of transmission line, the composition of T/L and near the T/L circumstances etc. Others are considered. The Barehand method of UHV T/L is extremely dangerous work and especially it is directly related with lineman life so it is very dangerous. It should be performed several technology developments for live-line work on the UHV T/L, that should be considered such as the electrical influence on workers near the T/L, development of live-line facilities, guarantee of safety, the technical rules of live-line work, the safe method of live-line work and etc. In order to maintain the 765kV transmission lines safely by barehand work, first of all, we should know the analysis of electrical safety level test in live-line work at 765kV vertical double circuit six bundle conductors on the suspension string tower type.

The design and implementation of echo canceller with new variable step size algorithm (새로운 가변 적응 상수 알고리즘을 이용한 반향제거기 설계 및 구현)

  • 최건오;윤성식;조현묵;이주석;박노경;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1533-1545
    • /
    • 1996
  • In this paper, the design and implementation of echo canceller with new variable step size algorithm is discussed. The method used in the new algorithm is to periodically adopt the test function which helps an optimal coefficient tracking. This algorithm outperforms LMS and VS algorithms in convergence speed and steady state error. As the period of test function is decreased, the speed of convergence is improved, but the number of calculation is increased, then the trade off between these parameters must be considered. Simulation results show new algorithm outperforms LMS and VS algorithms in convergence rate. For the design of hardware, circuit is designed with VHDL, and synthesized with Act1 withc is a FPGA library of ActelTM in use of synovation of InterGraph$^{TM}$. Verification of the synthesized circuit is carried out with simulator DLAB. The circuit based on the algorithm which is suggested in this paper calculated 7 radix places of inary number. A simulation data for the verification is based on the data of algorithm simulation. When the same input data is applied to the both simulation, output results of circuit simulation had slight difference in compare with that of algorithm simulation. The number of used gate is about 5,500 and We have 5.53MHz in maximum frequency.y.

  • PDF

Development of a 150W Switched Mode Power Supply operates at -40℃ (-40℃에서 동작하는 150W급 SMPS 개발)

  • Park, Sung-Il;Kim, Sung-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.85-92
    • /
    • 2018
  • In this paper, we designed a 150W LED lighting SMPS circuit operating at $-40^{\circ}C$. We designed a 150W LED lighting constant current circuit for the characteristics of the SMPS and fabricated and measured. The operating temperature range for a 150W LED lighting SMPS circuit is -40 to $70^{\circ}C$ and SMPS predicted life was 1.29-2.25 years based on 24 hours. The high acceleration life test and EMI test confirmed no abnormality.

Flux residue effect on the electrochemical migration of Sn-3.0Ag-0.5Cu (Sn-3.0Ag-0.5Cu 솔더링에서 플럭스 잔사가 전기화학적 마이그레이션에 미치는 영향)

  • Bang, Jung-Hwan;Lee, Chang-Woo
    • Journal of Welding and Joining
    • /
    • v.29 no.5
    • /
    • pp.95-98
    • /
    • 2011
  • Recently, there is a growing tendency that fine-pitch electronic devices are increased due to higher density and very large scale integration. Finer pitch printed circuit board(PCB) is to be decrease insulation resistance between circuit patterns and electrical components, which will induce to electrical short in electronic circuit by electrochemical migration when it exposes to long term in high temperature and high humidity. In this research, the effect of soldering flux acting as an electrical carrier between conductors on electrochemical migration was investigated. The PCB pad was coated with OSP finish. Sn3.0Ag0.5Cu solder paste was printed on the PCB circuit and then the coupon was treated by reflow process. Thereby, specimen for ion migration test was fabricated. Electrochemical migration test was conducted under the condition of DC 48 V, $85^{\circ}C$, and 85 % relative humidity. Their life time could be increased about 22% by means of removal of flux. The fundamentals and mechanism of electrochemical migration was discussed depending on the existence of flux residues after reflow process.

Electromagnetic energy harvesting from structural vibrations during earthquakes

  • Shen, Wenai;Zhu, Songye;Zhu, Hongping;Xu, You-lin
    • Smart Structures and Systems
    • /
    • v.18 no.3
    • /
    • pp.449-470
    • /
    • 2016
  • Energy harvesting is an emerging technique that extracts energy from surrounding environments to power low-power devices. For example, it can potentially provide sustainable energy for wireless sensing networks (WSNs) or structural control systems in civil engineering applications. This paper presents a comprehensive study on harvesting energy from earthquake-induced structural vibrations, which is typically of low frequency, to power WSNs. A macroscale pendulum-type electromagnetic harvester (MPEH) is proposed, analyzed and experimentally validated. The presented predictive model describes output power dependence with mass, efficiency and the power spectral density of base acceleration, providing a simple tool to estimate harvested energy. A series of shaking table tests in which a single-storey steel frame model equipped with a MPEH has been carried out under earthquake excitations. Three types of energy harvesting circuits, namely, a resistor circuit, a standard energy harvesting circuit (SEHC) and a voltage-mode controlled buck-boost converter were used for comparative study. In ideal cases, i.e., resistor circuit cases, the maximum electric energy of 8.72 J was harvested with the efficiency of 35.3%. In practical cases, the maximum electric energy of 4.67 J was extracted via the buck-boost converter under the same conditions. The predictive model on output power and harvested energy has been validated by the test data.

Development of A DC Motor Controller for 24V-500W Small Electric Vehicle (24V-500W급 소형전동차용 DC모터 속도 콘트롤러 개발)

  • Bang, Jun-Ho;Lee, Woo-Choun;Yu, Jae-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1777-1783
    • /
    • 2012
  • In this paper, a new motor driving circuit is designed to improve the output performance of DC motor, and a controller is developed with the designed circuit. By the designed driving circuit, a controller can continuously drive DC motors by a transformer which has switching signals of a self-generated circuit to operate it. And while the DC motor have a maximum velocity, the reference voltage can be maintained higher value than that of triangle voltage and it makes the DC motor driving transistor ON and maximum power. A 24V-500W DC motor controller is developed with the proposed motor driving circuit, and also a small electric car is made and the driving test of it is executed. The test results shows that it can continuously control go and back speed of motor with 12A driving current. And also, it is verified that the over current and heat detecting function is operating correctly and the rest value of the used battery can be displayed as 6 step from 20 to 100%.

Integrated Circuit Design and Implementation of the Voltage Controlled Chaotic Circuit (전압제어형 카오스회로의 집적회로 설계 및 구현)

  • 송한정;곽계달
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.12
    • /
    • pp.77-84
    • /
    • 1998
  • A voltage controlled chaotic circuit has been designed in integrated circuit and fabricated by using 0.8$\mu\textrm{m}$ single poly CMOS technology. The fabricated chaotic circuit consist of sample and hold circuits, op-amps, nonlinear function generator and two phase clock generator. The test results of the chaotic circuit show that periodic state, quasi-periodic state and chaotic state can be obtained according to the input control voltage with the ${\pm}$2.5V power supply and clock rate of 20kHz. In addition, two dimensional chaotic patterns have been observed by connecting this circuit in parallel or series

  • PDF