• Title/Summary/Keyword: tertiary treatment

Search Result 422, Processing Time 0.031 seconds

축산폐수 고도처리를 위한 미세조류 Scenedesmus acuminatus의 이용 가능성 (Potential Use of Microalgae Scenedesmus acuminatus for Tertiary Treatment of Animal Wastewater)

  • 박기영;임병란;이기세;이수구
    • 한국농공학회논문집
    • /
    • 제53권1호
    • /
    • pp.63-69
    • /
    • 2011
  • The green algae Scenedesmus acuminatus was cultured in different media: animal wastewater and an artificial culture medium in order to evaluate potential use for tertiary treatment. The experiments were conducted with air flowrate 1~2 L/min at $28{\sim}30^{\circ}C$. The nitrogen and phosphorus showed very similar removal efficiencies (68~77 % and 69~80 % for nitrogen and phosphorus respectively). The optimal fed period was estimated as three days in the semi-continuous experiment. The effects of $CO_2$ (4.5 %) injection on nutrient uptake from animal wastewater (biological treatment effluent) were compared to an air injection under the same conditions of light and photoperiod. The uptake rates of nutrient with air injection were observed 0.009 gN/gChl-a/day, 0.028 gN/gChl-a/day and T-P 0.003 gP/gChl-a/day for nitrate, total nitrogen and phosphorus respectively. The rates were enhanced by addition of $CO_2$ to 0.026 gN/gChl-a/day, 0.076 gN/gChl-a/day and T-P 0.018 gP/gChl-a/day. This study establishes that $CO_2$ addition during nutrient deprivation of microalgal cells may accelerate tertiary wastewater treatment.

상급종합병원 비대면 진료 재이용에 영향을 미치는 요인 (Factors Affecting the Reuse of Non-face-to-face Treatment by Non-face-to-face Treatment Patients in Tertiary General Hospital)

  • 민선영;김태현;이상규;장석용
    • 한국병원경영학회지
    • /
    • 제28권4호
    • /
    • pp.1-22
    • /
    • 2023
  • Purposes: The purpose of this study is to identify and analyze the factors that affect patients reusing non-face-to-face treatments at tertiary general hospitals. Methodology: We retrospectively analyzed a patient's reuse of non-face-to-face treatment from February 1, 2020, to December 31, 2021, at a tertiary general hospital in Seoul within one year of the first non-face-to-face treatment. A frequency analysis was conducted to identify the study subjects' demographic characteristics, treatment type characteristics, disease characteristics, and hospital use type characteristics. Also, across-analysis was conducted to verify the difference in non-face-to-face treatment reuse according to the characteristics a multiple logistic regression analysis was conducted to identify the factors affecting the reuse of non-face-to-face treatment by non-face-to-face treatment patients. Findings: The results of this study can be interpreted as indicating that the following groups are more likely tore use the non-face-to-face treatment: women, children, the elderly, Patients living far from the hospital, psychiatric patients, pediatric patients, medical benefits recipients, chronic patients, patients with mobility difficulties, and patients with high loyalty to hospitals. Practical Implications: When developing a non-face-to-face treatment system in the future, based on the results of this study, it is possible to target patients who prefer non-face-to-face treatment. And this study will be research material for vitalizing non-face-to-face treatment. In addition, the activation of the non-face-to-face treatment system will be an effective means for improving the quality of medical services and generating profits in hospitals in the future.

  • PDF

건강보험환자와 의료급여환자의 상급종합병원 입원이용 비교 (Utilization Patterns of National Health Insurance and Medical Aid Inpatients in Tertiary Hospitals)

  • 박영희
    • 보건의료산업학회지
    • /
    • 제6권4호
    • /
    • pp.83-98
    • /
    • 2012
  • The objective of this study is to analyze the utilization patterns of national health insurance and medical aid inpatients in tertiary hospitals. For the analysis, the study utilize the nationwide data on '2010 Survey of Patients' of Ministry of Health & Welfare. The statistical methodology used in the study is the logistic regression model. This study has three major findings. First, utilization rate of national health insurance inpatients was higher than medical aid inpatients in tertiary hospitals. Second, the significant affecting demographic factors in utilizing tertiary hospitals were sex, age, surgery case, treatment result, inpatients residence region and short length of stay. Third, compared to other disease groups, the inpatients on 'congenital malformation, deformity and chromosomal abnormalities', 'factors influencing health status and contact with health services' and 'neoplasm' groups are more likely to utilize tertiary hospitals. Finally, according to residence region, Seoul residence inpatients in both of national health insurance and medical aid more likely to utilize tertiary hospitals than other region inpatients.

수영 하수처리장 방류수의 해중 방류법과 3차 처리시설 설치시 비용 비교 분석 (Cost Analysis of Ocean Outfall and Tertiary Treatment Processes in Suyong Sewage Treatment Plant)

  • 박해식;조은일;박청길
    • 한국환경과학회지
    • /
    • 제8권1호
    • /
    • pp.115-123
    • /
    • 1999
  • 수영하수처리장 방류수의 해중방류법과 3차 처리 시설 설치의 비용분석을 한 결과는 다음과 같다. 1) 해안에서 4km 거리와 관경을 2m의 해중방류법을 이용한 수용만의 수질을 개선시키는데 소요되는 해중방류관 건설비용은 383억 원이 소요되는 것으로 산출되었다. 2) 수영하수처리장의 유출수를 해중방류관을 통해서 방류할 경우 방류수심을 32m, Diffuser의 길이를 200m로 할 경우의 초기희석배율은 유속에 따라서 56.4∼399.2으로 계산되었다. 3) 질소를 제거하기 위한 순환법의 경우의 20년 동안의 총 비용은 1,364억 원, 인을 제거하기 위한 응집제 첨가 활성슬러지법은 1,010억 원, 해중방류법은 383억 원으로 해중방류법이 3차 처리시설을 설치하는 비용보다 약 2.6∼3.5배 비용을 적게 소요하는 것으로 산출되었다. 4) 해중방류법을 이용할 경우의 수영만의 수질영향을 예측하기 위해서 물질순환모델을 이용하여 예측한 결과 수영만의 수질이 COD, 용존무기질소(DIN)와 용존무기인(DIP)의 전 항목에서 해역환경 II등급을 만족하는 것으로 예측되었다.

  • PDF

상급종합병원 중환자실 간호사의 좋은 죽음인식, 연명의료결정 인식 및 연명의료중단 결정 후 간호활동의 중요도 변화 (Awareness of good death, perception of life-sustaining treatment decision, and changes in nursing activities after decision to discontinue life-sustaining treatment among nurses in intensive care units at tertiary general hospitals)

  • 조규영;배혜리
    • 중환자간호학회지
    • /
    • 제16권3호
    • /
    • pp.109-122
    • /
    • 2023
  • Purpose : This study aims to explore nursing activities after the decision to discontinue life-sustaining treatment, awareness of a good death, and perception of life-sustaining treatment decisions among nurses in intensive care units (ICUs) at tertiary general hospitals. Methods : Participants were 173 nurses working in two tertiary general hospitals. The data were collected using structured questionnaires and analyzed using an independent t-test, paired t-test, one-way ANOVA, Scheffé's test, and Pearson's correlation coefficient. Results : Participants were 173 nurses working in two tertiary hospitals. The nursing activity increase was the greatest in the spiritual domain, and the physical domain was where the activities decreased the most. There were significant associations between Awareness of good death (Clinical) and Perception of life-sustaining treatment decision(r=.26, p <.001), Awareness of good death (Closure) and Perception of life-sustaining treatment decision(r=.36, p <.001), and Awareness of good death (Personal control) and Perception of life-sustaining treatment decision(r=.49, p <.001). Conclusion : Based on the results, systematic education programs and job training are required to improve the awareness regarding good death and perception of life-sustaining treatment decision for nurses in ICUs where discontinuing life-sustaining treatment decisions are made.

석유화학폐수 처리장 방류수의 재이용을 위한 고정생물막 공정에서 Fenton 산화전처리의 적응가능성 (Applicability of the lenten's Reagent Oxidation to Biological Fixed-Film Process for Reuse of Effluents from the Petrochemical Wastewster Effluent Treatment Plant)

  • 이규훈;김미화;박태주
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.115-115
    • /
    • 1995
  • Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton''s reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 kg COD/m3/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.

석유화학폐수 처리장 방류수의 재이용을 위한 고정생물막 공정에서 Fenton 산화전처리의 적응가능성 (Applicability of the lenten류s Reagent Oxidation to Biological Fixed-Film Process for Reuse of Effluents from the Petrochemical Wastewster Effluent Treatment Plant)

  • 이규훈;김미화;박태주
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.501-508
    • /
    • 1995
  • Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton's reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 kg COD/m3/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.

  • PDF

WASTEWATER TREATMENT USING COMBINATION OF MBR EQUIPPED WITH NON-WOVEN FABRIC FILTER AND OYSTER-ZEOLITE COLUMN

  • Jung, Yoo-Jin;Koh, Hyun-Woong;Shin, Won-Tae;Sung, Nak-Chang
    • Environmental Engineering Research
    • /
    • 제10권5호
    • /
    • pp.247-256
    • /
    • 2005
  • A combination of the submerged membrane activated-sludge bioreactor(SMABR) equipped with non-woven fabric filter and oyster-zeolite (OZ) packed-bed adsorption column was studied to evaluate the advanced tertiary treatment of nitrogen and phosphorous. The non-woven filter module was submerged in the MBR and aeration was operated intermittently for an optimal wastewater treatment performance. Artificial wastewater with $COD_{Cr}$ of 220 mg/L, total nitrogen (T-N) of 45 mg/L, and total phosphorous (T-P) of 6 mg/L was used in this study. MLSS was maintained about $4,000\;{\sim}\;5,000\;mg/L$ throughout the experiments. The experiments were performed for 100-day with periodic non-woven filter washing. The results showed that $COD_{Cr}$ could be effectively removed in SMABR alone with over 94% removal efficiency. However, T-N and T-P removal efficiency was slightly lower than expected with SMABR alone. The permeate from SMABR was then passed through the OZ column for tertiary nutrients removal. The final effluent analysis confirmed that nutrients could be additionally removed resulting in over 87% and 46% removal efficiencies for T-N and T-P, respectively. The results of this study suggest that the waste oyster-shell can be effectively reclaimed as an adsorbent in advanced tertiary wastewater treatment processes in combination with SMABR equipped with non-woven fabric filter.

생물막 여과반응기를 이용한 고도질소 제거법의 개발 (Development of Biological Filtration Process for Effective Nitrogen Removal in Tertiary Treatment of Sewage)

  • 정진우;김성원;津野洋
    • 한국물환경학회지
    • /
    • 제22권2호
    • /
    • pp.222-229
    • /
    • 2006
  • The treatment performance and operational parameters of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. In Filter 2, denitrification was accomplished under LV of 50~168 m/d in a 1 m filter-bed. However, the denitrification capacity reached the maximum when the linear velocity was increased to 202 m/d. Relationship between increase in microorganism and headloss was clearer in Filter 2. As a result, the denitrification rate increased from 1.0~2.3 kgN/($m^3-filter-bed{\cdot}d$) as the headloss increased. The COD removal rate was 6.0~9.6 kgCOD/($m^3-filter-bed{\cdot}d$) when operated with Filters 1 and 2. These results mean that captured bacteria contributed a part of COD consumption and denitrification. The maximum nitrification and denitrification rate was 0.5 and 4 kgN/($m^3-filter-bed{\cdot}d$) in Filter 1 and 2.The ratio of backwashing water to the treated water was about 5~10 %. In Filter 1, wasted sludge in backwashing was only 0.7~5.3 gSS/($m^3$-treated water). In Filter 2, added methanol was converted into sludge and its value was 8.0~24 gSS/($m^3$-treated water). These results proved that this process is both convenient to install as tertiary treatment and cost effective to build and operate.

텍스트 마이닝을 통한 상급종합병원의 미션, 비전, 핵심가치 분석 연구 (Analysis of Mission, Vision and Core values in Korean Tertiary General Hospitals Through Text Mining)

  • 이지훈
    • 한국병원경영학회지
    • /
    • 제28권2호
    • /
    • pp.32-43
    • /
    • 2023
  • Purposes: This research is conducted to identify main features and trends of mission, vision and core values in Korean tertiary general hospitals by using text-mining. Methodology: For the study, 45 mission, 112 vision and 190 core values are collected from 45 tertiary general hospitals' homepages in 2022 and use word frequency analysis and Leyword co-occurrence analysis. Findings: In the tertiary general hospitals' mission, there are high frequency words such as 'health', 'humanity', 'medical treatment', 'education', 'research', 'happiness', 'love', 'best', 'spirit', and mission mainly includes the content of contributing humanity's health and happiness with these words. In case of vision, high frequency words are 'hospital', 'medical treatment', 'research', 'lead', 'trust', 'centered', 'patient', 'best', 'future'. By using these words in vision, it represents the definition and characteristics of vision such as ideal organizations in the future, goals and targets. As a result of the Leyword co-occurrence analysis, vision includes the content of 'high-tech medical treatment', 'special care for patients', 'leading education and research', 'the highest trust with customer', 'creative talents training'. -astly, the high frequency word-pairs in core values are 'social distribution', 'innovation pursuit', 'cooperation and harmony', and it defines standards of behavior for organizations. Practical Implication: To correct the problems of vision, mission and core values from findings, firstly, it needs for Korean tertiary general hospitals to use the words that can explain organization's identity and differentiate others in their mission. Secondly, considering strengthening the role of hospitals in their community and the importance of members in organizations, it is necessary to establish vision with considering community and members to activate vision effectively. Thirdly, because there are no specific guidelines of establishing mission, vision and core values for healthcare organizations, this research concepts and results could be utilized when other organizations establish mission, vision and core values.

  • PDF