• 제목/요약/키워드: tension tests

검색결과 866건 처리시간 0.023초

Corrosion effects on tension stiffening behavior of reinforced concrete

  • Shayanfar, M.A.;Ghalehnovi, M.;Safiey, A.
    • Computers and Concrete
    • /
    • 제4권5호
    • /
    • pp.403-424
    • /
    • 2007
  • The investigation of corrosion effects on the tensile behavior of reinforced concrete (RC) members is very important in region prone to high corrosion conditions. In this article, an experimental study concerning corrosion effects on tensile behavior of RC members is presented. For this purpose, a comprehensive experimental program including 58 cylindrical reinforced concrete specimens under various levels of corrosion is conducted. Some of the specimens (44) are located in large tub containing water and salt (5% salt solution); an electrical supplier has been utilized for the accelerated corrosion program. Afterwards, the tensile behavior of the specimens was studied by means of the direct tension tests. For each specimen, the tension stiffening curve is plotted, and their behavior at various load levels is investigated. Average crack spacing, loss of cross-section area due to corrosion, the concrete contribution to the tensile response for different strain levels, and maximum bond stress developed at each corrosion level are studied, and their appropriate relationships are proposed. The main parameters considered in this investigation are: degree of corrosion ($C_w$), reinforcement diameter (d), reinforcement ratio (${\rho}$), clear concrete cover (c), ratio of clear concrete cover to rebar diameter (c/d), and ratio of rebar diameter to reinforcement percentage ($d/{\rho}$).

Simulation and Experimental Study of A TLP Type Floating Wind Turbine with Spoke Platform

  • Kim, Hyuncheol;Kim, Imgyu;Kim, Yong Yook;Youn, DongHyup;Han, Soonhung
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제2권4호
    • /
    • pp.179-191
    • /
    • 2016
  • As the demand for renewable energy has increased following the worldwide agreement to act against global climate change and disaster, large-scale floating offshore wind systems have become a more viable solution. However, the cost of the whole system is still too high for practical realization. To make the cost of a floating wind system be more economical, a new concept of tension leg platform (TLP) type ocean floating wind system has been developed. To verify the performance of a 5-MW TLP type ocean floating wind power system designed by the Korea Advanced Institute of Science and Technology, the FAST simulation developed by the National Renewable Energy Laboratory is used. Further, 1/50 scale model tests have been carried out in the ocean engineering tank of the Research Institute of Medium and Small Shipbuilding, Korea. This paper compares the simulation and ocean engineering tank test results on motion prediction and tension assessment of the TLP anchor.

CONTAINMENT PERFORMANCE EVALUATION OF PRESTRESSED CONCRETE CONTAINMENT VESSELS WITH FIBER REINFORCEMENT

  • CHOUN, YOUNG-SUN;PARK, HYUNG-KUI
    • Nuclear Engineering and Technology
    • /
    • 제47권7호
    • /
    • pp.884-894
    • /
    • 2015
  • Background: Fibers in concrete resist the growth of cracks and enhance the postcracking behavior of structures. The addition of fibers into a conventional reinforced concrete can improve the structural and functional performance of safety-related concrete structures in nuclear power plants. Methods: The influence of fibers on the ultimate internal pressure capacity of a prestressed concrete containment vessel (PCCV) was investigated through a comparison of the ultimate pressure capacities between conventional and fiber-reinforced PCCVs. Steel and polyamide fibers were used. The tension behaviors of conventional concrete and fiber-reinforced concrete specimens were investigated through uniaxial tension tests and their tension-stiffening models were obtained. Results: For a PCCV reinforced with 1% volume hooked-end steel fiber, the ultimate pressure capacity increased by approximately 12% in comparison with that for a conventional PCCV. For a PCCV reinforced with 1.5% volume polyamide fiber, an increase of approximately 3% was estimated for the ultimate pressure capacity. Conclusion: The ultimate pressure capacity can be greatly improved by introducing steel and polyamide fibers in a conventional reinforced concrete. Steel fibers are more effective at enhancing the containment performance of a PCCV than polyamide fibers. The fiber reinforcementwas shown to bemore effective at a high pressure loading and a lowprestress level.

Force monitoring of Galfan cables in a long-span cable-truss string-support system based on the magnetic flux method

  • Yuxin Zhang;Xiang Tian;Juwei Xia;Hexin Zhang
    • Structural Monitoring and Maintenance
    • /
    • 제10권3호
    • /
    • pp.261-281
    • /
    • 2023
  • Magnetic flux sensors are commonly used in monitoring the cable force, but the application of the sensors in large diameter non-closed Galfan cables, as those adopted in Yueqing Gymnasium which is located in Yueqing City, Zhejiang Province, China and is the largest span hybrid space structure in the world, is seldom done in engineering. Based on the construction of Yueqing Gymnasium, this paper studies the cable tension monitoring using the magnetic flux method across two stages, namely, the pre-calibration stage before the cable leaves the rigging factory and the field tension formation stage of the cable system. In the pre-calibration stage in the cable factory, a series of 1:1 full-scale comparative tests were carried out to study the feasibility and relability of this kind of monitoring method, and the influence on the monitoring results of charging and discharging voltage, sensor location, cable diameter and fitting method were also studied. Some meaningful conclusions were obtained. On this basis, the real-time cable tension monitoring system of the structure based on the magnetic flux method is established. During the construction process, the monitoring results of the cables are in good agreement with the data of the on-site pressure gauge.The work of this paper will provide a useful reference for cable force monitoring in the construction process of long-span spatial structures.

Constitutive Law of Reinforced Concrete Subjected to Biaxial Tension (2축 인장을 받는 철근콘크리트의 구성방정식)

  • Cho, Jae-Yeol;Kim, Nam-Sik;Cho, Nam-So;Choun, Young-Sun
    • Journal of the Korea Concrete Institute
    • /
    • 제15권1호
    • /
    • pp.69-77
    • /
    • 2003
  • One directional and biaxial tension tests of 13 reinforced concrete panels were conducted to derive a constitutive law of concrete. Based on the test results, a model equation is derived for the stress-strain relationship of concrete in tension. Main test variables are reinforcement ratio and the load ratio applied in two directions. In addition a failure envelope of concrete in tension-tension region is suggested based on the initial crack occurrence. Test results show that the concrete carries substantial tensile stress even after cracking occurrence. However, the application of this proposed stress-strain relationship for concrete is limited to the case where the direction of reinforcement coincides with the direction of the applied principal stresses.

An Experimental Study on Flexural Behavior of RC Beams Strengthened with Hi-Strength Bars(3) (고장력 인장봉으로 보강된 RC 보의 휨 거동에 관한 실험적 연구(3))

  • Shin, Kyung-Jae;Kim, Yoon-Jung;Moon, Jeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • 제19권3호
    • /
    • pp.351-358
    • /
    • 2007
  • Unlike external bonded steel plate or carbon fiber, the external unbonded strengthening using hi-strength bar has some advantages in speed and simplicity of installation. It is not required surface preparations and not affected by environmental conditions. A set of nine laboratory tests on RC beams strengthened using the hi-tension bars are reported. Anchoring pin developed in former research is installed at the end of beam to connect the hish-tension bar to RC beam. The test results strengthened by hi-tension bars are compared with those of non-strengthened specimens. The main test parameters are the cross-sectional area of the high-tension bar, distance of stirrups and condition of supports. Test results show that the beams reinforced are superior to reference specimens, especially for the strength and deformation capacity. Also, shear resisting effect of hi-strength bar can be confirmed in the specimens which have lack of stirrups.

Surfactant Aided Air-sparging for Groundwater Remediation (계면촬성제 첨가에 따른 지하수 폭기법의 폭기효율 변화 연구)

  • 소효은;최경민;이승재;김헌기
    • Economic and Environmental Geology
    • /
    • 제35권5호
    • /
    • pp.421-428
    • /
    • 2002
  • Lab-scale experiments were conducted to evaluate the effect of surface tension reduction on the extension of the influence zone and the VOC removal efficiency of ground water sparging. A glass column packed with coarse sand was used for VOC removal test at two different surface tensions. A glass column without porous media was also used fer control purpose prior to sand-packed column test. A quasi-two-dimensional glass box model, packed with a sand, was used fer sparging zone tests at different water surface tensions. Surface tension of the aquoues solution used in this study was controlled using sodium dodecyl sulfate (SDS). For the glass, sand column experiments, total amount of air filled in the media increased as surface tension decreased. Toluene (used as VOC in this study) removal rate increased slightly with decreased surface tension f3r both free water column and sand-packed column. Air sparging zone extended up to 500% as the surface tension decreased. Combining the results from two different experiments, VOC removal efficiency is expected to increase significantly with surface tension reduction.

다공질 금속의 소성 항복 거동

  • 김형섭;이동녕
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 한국소성가공학회 1992년도 춘계학술대회 논문집 92
    • /
    • pp.59-70
    • /
    • 1992
  • Appropriate yield criteria are necessary to perform computer simulation for densification processes of powder compacts and sintered metals. Various yield functions have been reviewed and a new form for yield criterion has been advanced. The yield criterion satisfies experimental results from combined tension and torsion tests of sintered porous iron specimens.

  • PDF

Comparative studies on numerical optimal design techniques (수치해석에 의한 최적화 설계 기법의 비교 연구)

  • 조선휘;박종근
    • Journal of the korean Society of Automotive Engineers
    • /
    • 제4권2호
    • /
    • pp.79-85
    • /
    • 1982
  • Computer codes on two numerical optimization methods-Sequentially Unconstrained Minimization Technique (SUMT) and Gradient Projection Method-are constructed and tested with several test problems. Design formulation of tension - compression coil spring is set up and the solution is obtained. Consequently, the feature, the advantage and the limitation of these methods, made clear through the tests, are discussed.

  • PDF

THE EFFECTS OF HEAT TREATMENT OF ORTHODONTIC WIRES (교정용 강선재의 열처리 효과에 관한 실험적 연구)

  • Lee, Myeung-Suck;Sohn, Byung-Hwa
    • The korean journal of orthodontics
    • /
    • 제22권3호
    • /
    • pp.591-602
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of heat treatment on physical properties of 0.016' and 0.016' x 0.022' stainless steel wires. Temperature of heat treatment had intervals of $50^{\circ}C$ from $400^{\circ}C$ to $700^{\circ}C$, and time of heat treatment were 3, 6 and 9 minutes. Tensile tests were measured by ultimate tensile strength and yield strength. Bending tests were assessed by maximum bending force, recovery force, and stiffness. Torsion test was evaluated by torsion cycle until wires were fractured. The results were as follows: 1. In round wires, the highest value of ultimate tensile strength and yield strength were recorded of heat treatment at $500^{\circ}C$. In rectangular wires, the highest value of ultimate tensile strength were after 9 minutes at $400^{\circ}C,\;450^{\circ}C$ and 3, 6 minutes of heat treatment at $50^{\circ}C$, yield strength were the highest value after 3, 6 minutes of heat treatment at $500^{\circ}C$. 2. In both round and rectangular wires, maximum bending force and recovery force were the highest values after 6 minutes of heat treatment at $500^{\circ}C$. In round wires, highest value of stiffness were formed after 9 minutes at heat treatment at $500^{\circ}C$. In rectangular wires, the highest value of stiffness were for 6 minutes in $500^{\circ}C$. 3. In rectangular wires, torsion cycle was minimum after 6 minutes of heat treatment at $500^{\circ}C$. 4. In all of tension, bending, and torsion tests, the heat treated wires were softened over at $700^{\circ}C$. 5. In all of tension, bending, and torsion tests, physical properties of the wires were more influenced by the temperatures than the duration of the heat treatment.

  • PDF