• Title/Summary/Keyword: tension measurement

Search Result 360, Processing Time 0.024 seconds

Review of Membrane Tension Maintenance System for Membrane Structures through Membrane Tension Measurement (막장력 측정을 통한 막구조물의 장력 유지관리 시스템 검토)

  • Jin, Sang-Wook;Shon, Su-Deok;Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.39-45
    • /
    • 2016
  • Membrane structure is a system that is stabilized by maintaining a tensile state of the membrane material that originally cannot resist the bending or pressure. Also, it is a system that allows the whole membrane structure to bear external loads caused by wind or precipitation such as snow, rain and etc. Tension relaxation phenomenon can transpire to the tension that is introduced to the fabric over time, due to the innate characteristics of the membrane material. Thus, it is important to accurately understand the size of the membrane tension after the completion of the structures, for maintenance and management purposes. The authors have proposed the principle of theoretically and indirectly measuring the tension by vibrating the membrane surface with sound waves exposures against the surface, which is compartmentalized by a rectangular boundary, and by measuring the natural frequency of the membrane surface that selectively resonates. The authors of this paper measured the tension of preexisting membrane structure for its maintenance by using the developed portable measurement equipment. Through analyzing the measurement data, the authors review the points that should be improved and the technical method for the new maintenance system of membrane tension.

Detection of tension force reduction in a post-tensioning tendon using pulsed-eddy-current measurement

  • Kim, Ji-Min;Lee, Jun;Sohn, Hoon
    • Structural Engineering and Mechanics
    • /
    • v.65 no.2
    • /
    • pp.129-139
    • /
    • 2018
  • Post-tensioning (PT) tendons are commonly used for the assembly of modularized concrete members, and tension is applied to the tendons during construction to facilitate the integrated behavior of the members. However, the tension in a PT tendon decreases over time due to steel corrosion and concrete creep, and consequently, the stress on the anchor head that secures the PT tendon also diminishes. This study proposes an automatic detection system to identify tension reduction in a PT tendon using pulsed-eddy-current (PEC) measurement. An eddy-current sensor is installed on the surface of the steel anchor head. The sensor creates a pulsed excitation to the driving coil and measures the resulting PEC response using the pick-up coil. The basic premise is that the tension reduction of a PT tendon results in stress reduction on the anchor head surface and a change in the PEC intensity measured by the pick-up coil. Thus, PEC measurement is used to detect the reduction of the anchor head stress and consequently the reduction of the PT tendon force below a certain threshold value. The advantages of the proposed PEC-based tension-reduction-detection (PTRD) system are (1) a low-cost (< $ 30), low-power (< 2 Watts) sensor, (2) a short inspection time (< 10 seconds), (3) high reliability and (4) the potential for embedded sensing. A 3.3 m long full-scale monostrand PT tendon was used to evaluate the performance of the proposed PTRD system. The PT tendon was tensioned to 180 kN using a custom universal tensile machine, and the tension was decreased to 0 kN at 20 kN intervals. At each tension, the PEC responses were measured, and tension reduction was successfully detected.

Development of a Tensile Force Measurement Device of Long Duration (인장력 상시 측정장치 개발에 관한 연구)

  • Shin, Kyung Jae;Hwang, Yun Ha
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.4 s.65
    • /
    • pp.435-445
    • /
    • 2003
  • Tension member is one of the most important elements in tension structure. An economical and reliable measurement method of a member's tensile force has yet to be developed, however. Several conventional measurement methods have some disadvantages when used for long-term, on-site measurement. A new tension-force measurement device was proposed to resolve measuring problems. Its principle was to use the bending part of the device as an elastic spring. The lateral deformation of the bending part due to tensile force can be measured to monitor the tensile force. This device was inserted in the tension member like a turn-buckle. Lateral deformation may be measured in the field at any time for the purpose of maintaining structures. Finite element analysis was used to design the shape and parametric study. Six specimens were tested within the elastic range. The test result showed that the elastic behavior or the bending part was consistent with the analysis' results.

DEVEOPMENT OF MEASURING SYSTEM OF MEMBRANE STRESS FOR MEMBRANE STRUCTURE (막구조물의 막장력 측정장치 개발에 관한 연구)

  • Jung, Hwan-Mok;Woo, Jae-Won;Cho, Byung-Wook;Lee, Seong-Yeun
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.171-178
    • /
    • 2008
  • This paper is concerned with the development of a measurement system using field measuring device which will give the membrane stress of the membrane structures. Up to this point, several techniques on measurement of membrane stresses has been proposed and some have been used in the fields, but accuracy of the measured stresses to be far from reliable one. Such situation has not been changed until recent days, we do not have the measurement device on which we can depend. On top of that, due to the different properties in cross directions for material of the membrane, the stress in the warp direction is different from that in the fill one. A new method is proposed to measured membrane stresses in two different direction separately, where instead of membrane stresses directly, an external force perpendicular to the membrane to be applied. A portable device can measure the applied force and the displacement. A special testing bed to be fabricated to accommodate $50cm{\times}50$ manbrane specimen which can apply 5 ton load in two orthogonal direction. A special device using push-pull gage was developed. To measure the membrane stresses in warp and fill direction separately, a different length of the tips are used. The measuring device which can called tension meter, can be calibrated on the testing bed, and optimized the length and shape of tip.

  • PDF

A Study on Temperature Properties Analysis for Tension Measurement of Steel Cables Using Magnetic Sensor (자기센서에 의한 강재 케이블 장력측정에서 온도특성에 대한 연구)

  • Park, Hae-won;Ahn, Bong-young;Lee, Seung-seok;Park, Jeong-hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.2 s.54
    • /
    • pp.181-188
    • /
    • 2009
  • Measuring the tensile strength of steel cables used to support bridges is a critical inspection item in terms of the safety of a bridge. Today, cable tension is measured with the vibration method and loadcell. Recently, some advanced countries have conducted studies on measuring tension with magnetic method and are suggesting prospective results. Since there were no such studies ongoing in Korea, we began a study on measuring tension with magnetic method as we are undergoing researches to improve the precision of measurements. It is necessary to consider the influence for the magnetic field and the temperature of steel cables in tension measurement of magnetic method. In this paper, we tested an output characteristic of tension sensor according to temperature and deduced temperature compensation coefficient in the given magnetic field and applied the compensation coefficient to the tension measurement system in the lab. We analyzed and evaluated testing results for the output voltages of the tension sensor according to cable tensions.

Comparison between bladder urine $O_{2}$ tension and mixed venous blood $O_{2}$ tension in human (방광뇨와 혼합정맥혈의 산소분압의 비교)

  • 이두연
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.563-568
    • /
    • 1986
  • Tissue 02 tension is an important guide in detection of the general condition in critical patients. The tissue 0, is more difficult to measure with 0, sensor in skeletal muscle and subcutaneous tissues to present. But it is much easier to measure 0, tension in bladder urine with Censini catheter in Foley catheter than in tissue. We have measured 0, tension in bladder urine, main pulmonary artery and radial artery in 16 patients in chest surgical department of Yonsei University. College of Medicine from September 26 to December 22, 1981. Six patients were male and ten patients were female. Their ages ranged from 8 to 43 years. The correlation equation between the simultaneously measured PuO2 and PvO2 was found to be Ypvo2=4.04 + 0.88 Xpuo2 [r=0.88, p<0.0001] in regression curve with computer [HP/3,000, Program: SPSS] in the Yonsei University. Measurement of 0, tension in bladder urine and MPA will be rather simple, rapid and reproducible method than that of the 0, tension in tissues. But the speed of 0, consumption in urine is fast and so the 0, tensions in bladder urine were measured as soon as possible after they were collected. They were no complications or morbidity during measurement of 0, tension in these procedures except spontaneous removal of radial arterial cannulas in 2 patients.

  • PDF

MEASUREMENT OF SURFACE TENSION OF MOLTEN METALS IN ARC WELDING

  • Shinobu Satonaka;Shigeo Akiyoshi;Inoue, Rin-taro;Kim, Kwang-Ryul
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.757-762
    • /
    • 2002
  • Many reports have been shown that the buoyancy, electromagnetic force, surface tension, and gas shear stress are the driving forces of weld pool circulation in arc welding. Among them, the surface tension of molten metal plays an important role in the flow in weld pool, which are clarified by the specially designed experiments with small particles as well as the numerical simulations. The surface tension is also related to the penetration in arc welding. Therefore, a quantitative evaluation of surface tension is demanded for the development of materials and arc process control. However, there are few available data published on the surface tension of molten metals, since it depends on the temperature and the composition of materials. In this study, a new method was proposed for the evaluation of surface tension and its temperature dependence, in which it is evaluated by the equilibrium condition of acting forces under a given surface geometry, especially back surface. When this method was applied to the water pool and to the back surface of molten pool in the stationary gas tungsten arc welding of thin plate, following results were obtained. In the evaluation of surface tension of water, it was shown that the back surface geometry was very sensitive to the evaluation of surface tension and the evaluated value coincided with the surface tension of water. In the measurement of molten pool in the stationary gas tungsten arc welding, it was also shown that the comparison between the surface tension and temperature distribution across the back surface gave the temperature dependent surface tension. Applying this method to the mild steel and stainless steel plates, the surface tension with negative gradient for temperature is obtained. The evaluated values are well matched with ones in the published papers.

  • PDF

The Opening Size Change for Screen Tension (스크린 망사의 견장과 오프닝의 변화)

  • Jung, Gi-Young;Kang, Young-Reep
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.28 no.1
    • /
    • pp.43-50
    • /
    • 2010
  • The 200mesh screen was tensioned and fixed on a frame. When applied tension to 5N and 10N per unit area, a side length of opening of the screen was 163.223${\mu}m$ and 168.224${\mu}m$, respective. But side length not tensioned was 158.879${\mu}m$. We knew that a side length of opening of the screen rarely changes with tension applied to the screen. The appearances that a side length of opening of the screen expand little are due to a decreasing diameter of thread by means of tension. In a thickness measurement of screen, While the high density mesh screen that had a lot of knots that crossed a line of latitude and longitude per unit area appeared a higher numerical value, the low density mesh screen that had a few knots appeared a low numerical value.

Measurement of the interfacial tension value for the polymer blends by breaking thread method (섬유사 붕괴 법(breaking thread)에 의한 고분자 블렌드의 계면장력 측정)

  • Son, Young-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1211-1214
    • /
    • 2007
  • In this paper, the experimental details of the interfacial tension measurement by breaking thread method, which measures the interfacial tension between different polymer pairs, are described. The apparatus needed are a hot state, which melts the polymers, and an optical microscopy. The measured interfacial tension values are in goog agreement with the literature's values.

  • PDF

Evaluation of Tension of Stay Cable using MBM (Measurement-based Model) (계측기반모델에 의한 사장케이블의 장력 평가)

  • Nam, Sang-Jin;Yhim, Sung-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.93-100
    • /
    • 2014
  • This study presents the recomposition of MBM (measurement-based model) using natural frequencies and modes from the usually measured data, and the evaluation of cable tension in service from the analysis results upon MBM of existing CSB (cable stayed bridge). The cable tension is shown to be different according to the position attached to cable and loading type. The measured cable tensions are not different distinctly according to position attached cable under dead and live loads, but larger than those under design loads. The distribution of cable tension calculated upon the MBM is similar to those of measured tension although the former is more than those of cable tension upon the design model. Considering to long-term behaviors of cable, therefore, the design of cable in CSB needs to apply the analysis results on MBM. For this purpose, future study needs lots of measured data and MBM is used to analyze the long-term behavior of cable in CSB.