• Title/Summary/Keyword: temporary denture

Search Result 39, Processing Time 0.024 seconds

CLINICAL APPLICATION OF TRANSITIONAL IMPLANTS (Transitional implant를 이용한 임시수복과 최종 수복)

  • Kim, Yu-Lee;Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.6
    • /
    • pp.575-580
    • /
    • 2005
  • Transitional implants were developed to support provisional restorations and to allow for load-free osseointegration of conventional implants while a patient was provided with immediate esthetics and function and are usually placed simultaneously at the time of definitive implant placement. Transitional implants are placed in a non-submerged fashion in a single-stage surgery and are designed to be immediately loaded. They generally are made of commercially pure titanium or titanium alloy and are designed as 1-piece implants composed of root and crown replacement segments. Transitional implants can be used in a wide range of indications, such as basic use as temporary implant, to support and protect the primary implants during the healing phase, single crown in the edentulous anterior region of mandibular, anchorage for orthodontic treatment, support a surgical and radiographic template, and primary implant to extremely atrophied alveolar crests of the mandible and maxilla. This article describes the clinical use of transitional implants to support the provisional complete denture and single crown in the restricted edenturous central incisor region of mandible.

Implant-assisted full denture using digital guide: a case report (무치악 환자에서 디지털 가이드를 이용한 임플란트 수복증례)

  • Kim, Wook Tae
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.202-209
    • /
    • 2021
  • By classifying temporary denture production for surgical guides, digital guide-based surgery, and final prosthesis production, the problems of each process were assessed in advance and the factors that could be improved were confirmed in this study. The manufacturing process of fusion dental prosthesis uses virtual programs and computed tomography images to manufacture devices using the latest technologies of computer-aided design/computer-aided manufacturing and three-dimensional printing, which enables implants to be placed in the desired location in advance. Moreover, implant placement is not dependent on the skill and condition of the dentist, and because it uses a computer system, it can always be performed at a constant and optimal position. This can reduce the remanufacturing rate compared with the general method, shorten the treatment period, and eliminate patient discomfort. Unlike the traditional method of using impression materials and plaster models, digital fusion dental prostheses would be evaluated as a technology for producing prosthesis through professional design technology and communication.

A Study on the Accuracy of the record base of the Complete Denture to the Master Cast according to Kinds of Resin and Polymerization Method

  • Choi, Hyo-Jin;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.310-320
    • /
    • 2000
  • Statement of the problem. The record base in fabricating procedures of the complete denture, as a temporary form for reproducing denture base, is used to record upper and lower jaw relation and to align artificial teeth and try-in it in the mouth. The accuracy of jaw relation record is affected by the accuracy, stiffness and stability of the record base. So, the accuracy of record base is the most important requirements of jaw relation records. Purpose of study. The purpose of this study was to evaluate the gap that occurred over the palatal area of a maxillary record base fabricated with autopolymerizing resin and light-curing resin. Methods/material. The maxillary record bases were fabricated out of autopolymerizing resin that is used the most frequently in clinics and light-curing resin that attracts special attention for its several merits. The light-curing resin was made by two kinds of polymerization methods, which are one step curing method and multiple step curing method. All record bases were cut in certain positions of the master cast 1 hour and 1 day later after fabrication and the accuracy of the master cast was measured and analyzed with a microscope. Results. A pattern of gap formation between the record base and the maxillary cast was observed in all specimens. According to kinds of resins, autopolymerizing resin was significantly more accurate than light-curing resin. There was no statistical difference according to time lapse, and in all three groups, the maximum discrepancy occurred at the posterior border in the mid-palatal region. Conclusion. The autopolymerizing resin is better than light-curing resin, and multiple step curing method is more accurate than one step curing method when using light-curing resin.

  • PDF

Linear measurement evaluation according to UV-type ultrasonic cleaning of artificial teeth for temporary dentures manufactured using a light-curing type printer produced by a DLP printer (광중합형 프린터로 제작한 임시 의치용 인공치아의 UV형 초음파 세척에 따른 선형측정 평가)

  • Dong-Yeon Kim;Gwang-Young Lee
    • Journal of Technologic Dentistry
    • /
    • v.46 no.1
    • /
    • pp.8-14
    • /
    • 2024
  • Purpose: This study compares the deformation of traditional resin dentures to resin dentures printed with digital light processing (DLP). Methods: Eleven edentulous research models were developed. Ten of them were made with traditional resin dentures. The remaining one was prepared for scanning and 3D (three-dimensional) printing. Ten traditional resin dentures were made, with the remaining artificial teeth created using 3D software and a DLP printer. Traditional resin dentures, 3D printed resin denture artificial teeth, and a denture base with artificial teeth were all cleaned simultaneously in an ultrasonic cleaner for 3 minutes. Three groups were assigned four artificial tooth measurement points, which were then measured with digital calipers. The measured data was analyzed using descriptive statistics. The significance test was conducted using a nonparametric test Kruskal-Wallis test due to the small number of specimens (α=0.05). Results: The traditional resin dentures had the lowest strain rate at -0.04%, while the group that manufactured only artificial teeth had the highest strain rate at -0.09%. However, no statistically significant difference was observed between the 3 groups (p>0.05). Conclusion: During ultraviolet-type ultrasonic cleaning, traditional resin dentures (TD group) and denture base with artificial teeth made of DLP (DD group) demonstrated stable durability, whereas the artificial teeth made of DLP (AD group) with only artificial teeth did not show a good deformation rate.

THE INHIBITING EFFECT OF TISSUE CONDITIONER COMBINED WITH ANTIFUNGAL AGENTS ON THE GROWTH OF CANDIDA ALBICANS (항진균제를 첨가한 수종의 점막 조정제가 Candida albicans 성장 억제에 미치는 효과)

  • Chang Dae-Soon;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.268-280
    • /
    • 1994
  • Tissue conditioners have been used for treatment of denture stomatitis caused by wearing of dentures. Early studies pointed out Candide albicans (C. albicans) as main etiologic factor, and antifugal agents were added for control of the species. But there is a little information about broad comparison on the effect of tissue conditioners and antifungal agents added. The purpose of the present study was to compare the inhibiting effect of four tissue conditioners and one temporary soft liner on the growth of C. albicans for treatment of denture stomatitis using gel diffusion method by measuring diameter of the zone of growth inhibition. Three antifungal agents were added to each material for evaluation of the effect of added agents. Finally, observation was made to evaluate the effect of the loss of antifungal elements by aging of the specimen. The results of this study were obtained as follows : 1. Tempo had remarkable antifungal effect showing the zone of growth inhibition as 2.35 mm at 1st day, and was most effective on End: 4th and 7th day from incubation (p<0.05). But Coecomfort, Dura conditioner, Visco-gel, Coe-soft had little antifungal effect from the 1st day of incubation. 2. Nystatin was most effective showing 9.60-12.04 mm of zone of inhibition at the 1st day from incubation. The antifungal properties were reduced to amphotericin B, chlorhexidine and materials without agent (p<0.05), and the effect was diminished by time. 3. As pretreatment with amphotericin B, nystatin, chlorhexidine, Tempo was very effective at the 1st day from incubation showing zone of inhibition as 3.65, 12.04, 4.78 mm with addition of each agent. Dura conditioner had strongest antifungal effect at the next day as 2.86, 5.33, 1.29 mm of zone of inhibition, and yielding results of Coe-comfort, Tempo, Coe-soft was shown at 4th and 7th day from incubation (p<0.05). Taken all together, tissue conditioners have little antifungal effect except Tempo. Formation of the zone of growth inhibition was due to agents amphotericin B, nystatin, chlorhexidine and nystatin was most effective. Conclusively, it is advisable to select material which is effective on the growth of C. albican and consider addition of antifungal agents for treatment of denture stomatitis.

  • PDF

A Case of Radiolucent Foreign Body (Temporary Resin Bridge) Aspiration Accompanied by Inflammatory Polyps (방사선 투과성 이물 흡인(Temporary Resin Bridge)에 의한 염증성 용종 1예)

  • Moon, Seol Kyung;Lee, Ji Myoung;Jeong, Hae Bin;Song, Joo Yong;Kim, Sung Kyoung;Lee, Sang Haak;Yoon, Hyeong Kyu;Lee, Sook Young;Kim, Seok Chan;Moon, Hwa Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.6
    • /
    • pp.456-459
    • /
    • 2008
  • This case demonstrates the rare occurrence of a radiolucent temporary resin bridge aspiration in adults while they are in a conscious and awaken state and the resultant formation of inflammatory polyps. Although no unique findings were noted in a chest x-ray, careful history taking accompanied by physical examinations can lead to clinical suspicion of foreign body aspiration in an earlier stage. Moreover, flexible bronchoscopy is a tool useful not only for the evaluation process but also for managing the aspirated foreign material.

The efficacy of denture cleansing agents: A scanning electron microscopic study (수종 의치세정제의 세척 효과에 관한 주사전자현미경적 비교 연구)

  • Yun, Bo-Hyeok;Yun, Mi-Jung;Hur, Jung-Bo;Jeon, Young-Chan;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.57-64
    • /
    • 2011
  • Purpose: The purpose of this study was to compare the cleansing performance of a distilled water, a diluted solution of sodium hypochlorite as a household bleaching cleanser and three alkaline peroxide cleansers in vivo plaque deposits by using scanning electron microscope. Materials and methods: Five individuals were selected from department of the prosthodontics in Pusan National University Hospital, and each of them was inserted with specimens for plaque accumulation in their temporary dentures for 48 hours. The specimens were removed and cleaned by each cleansing agents for 8 hours. Scanning electron micrographs were made from the specimens at a magnification of ${\times}2,000$. A panel of ten persons with a dental or paradental background, but not directly involved in the study, was selected to analyze the photomicrographs to determine which denture cleanser was more effective in removing plaque. Results: Diluted solution of sodium hypochlorite was the most effective at removing plaque following $Polident^{(R)}$, $Cleadent^{(R)}e$, $Bonyplus^{(R)}$ and distilled water in order. But there was no significant difference of cleansing efficacy between diluted solution of sodium hypochlorite and $Polident^{(R)}$, $Polident^{(R)}$ and $Cleadent^{(R)}e$, $Cleadent^{(R)}e$ and $Bonyplus^{(R)}$, respectively (P > .05). Alkaline peroxide cleansers by themselves cannot adequately remove accumulated plaque deposits, especially if the deposits are heavy. Corrosion could be seen on the surface of non-precious alloy specimens immersed in diluted solution of sodium hypochlorite. Conclusion: It is recommended to use of alkaline peroxide type cleansers with brushing whenever possible, since denture cleanliness is often poor due to the relative inefficiency of these cleansers.

Study of the fracture resistance of zirconia on posterior fixed partial dentures based on inter-abutment distance (지르코니아 고정성 국소의치의 지대치간 거리에 따른 파절저항성에 관한 연구)

  • Park, Gi-Beom;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.61-69
    • /
    • 2020
  • Purpose: Zirconia fixed partial dentures with mandibular 2nd premolar and 2nd molar as abutments are fabricated and then the effects of inter-abutment distance on fracture resistance of zirconia fixed partial dentures is studied. Materials and Methods: The materials used in this study are Cameleon S zirconia block and S2 zirconia block, which are divided into CS Group and S2 Group applying different inter-abutment distance for each material, and the sintered zirconia fixed partial denture was luted to the epoxy resin die using a temporary luting cement, and then the fracture resistance was measured by placing a 6 mm diameter hardened steel ball on the occlusal surfaces of the pontics and applying pressure at a cross head speed of 1.0 mm/min on a universal testing machine with a load cell of 5.0 kN. Results: The fracture resistance of zirconia fixed partial dentures is not significantly affected by inter-abutment distance The fracture resistance of zirconia fixed partial dentures in CS Group was significantly higher in 15 mm of inter-abutment distance than in 13 mm and 17 mm of inter-abutment distance (P < 0.05). The fracture resistance of zirconia fixed partial dentures in S2 Group was not significantly different between the three groups (P > 0.05). Conclusion: The fracture resistance of zirconia fixed partial dentures with mandibular 2nd premolar and 2nd molar as abutments does not significantly affected by the inter-abutment distance.

The incidence of the abutment screw loosening and its affecting factors in posterior implant restorations (구치부 임플란트 고정성 수복물에서의 지대주 나사 풀림 현상과 이에 영향을 미치는 요인)

  • Hong, Su-Jung;Bae, Jung-Yoon;Kim, Hyun-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.212-217
    • /
    • 2018
  • Purpose: This study was to assess clinically the incidence of abutment screw loosening of posterior implant-supported fixed prosthesis and its affecting factors. Materials and methods: 391 implant-supported crowns restored from January 2013 to January 2016 were included in this study. All restorations were fabricated with either a single crowns or a splinted crown, and cemented with temporary cement. The incidence of abutment screw loosening is investigated and gender, restoration position, opposing teeth, restoration type, abutment connection type were assessed as possible factors affecting abutment screw loosening. Results: During the observation period (2 - 5 years), abutment screw loosening was found in 29 restorations (7.4%). It took 3 to 48 months (means 19.5 months) to loose the screw, and three of these implants were fractured. Among the factors considered, there were statistically significant differences at abutment screw loosening rate between molar group (9.4%) and premolar group (2.6%) (P<.019). According to the type of opposing teeth, there were statistically significant differences between nature teeth (74.7%) and implant (25.0%), removable denture (3%) (P<.019). The other possible factors did not have a significant effect on loosening of the abutment. Conclusion: The incidence of abutment screw loosening in posterior restoration was 7.4%. Abutment screw loosening were more likely to occur in molars group than premolar group, and according to the opposing teeth, there were the greatest frequency in nature teeth than implant and removal denture. There was a statistically significant difference.

CLINICAL AND RADIOGRAPHICAL EVALUATION OF IMPLANT-SUPPORTED FIXED PARTIAL PROSTHESES (임플랜트 지지 고정성 국소의치의 임상적, 방사선학적 평가)

  • Seo Ji-Young;Shim June-Sung;Lee Jae-Hoon;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.394-404
    • /
    • 2006
  • Statement of problem: A conventional 3-unit fixed partial denture design with a pontic between two retainers is the most commonly used. However in cases where the mental nerve is in close proximity to the second premolar, a cantilever design can be considered. As such, logical and scientific evidence is lacking for the number and position of implants to be placed for partially edentulous patients, and no clear-cut set of treatment principles currently exist. Purpose : The purpose of this study was to evaluate prognosis of implant-supported fixed partial dentures and to compare changes in bone level which may rise due to the different factors. Material and method : The present study examined radiographical marginal bone loss in patients treated with implant-supported fixed partial dentures (87 prostheses supported by 227 implants) and evaluated the influence of the span of the pontic, type of the opposing dentition. Clinical complications were studied using a retrospective method. Within the limitation of this study. the following result were drawn Result, 1. Seven of a total of 227 implants restored with fixed prostheses failed, resulting in a 96.9% success rate. 2. Complications encountered during recall appointments included dissolution of temporary luting agent (17 cases), porcelain fracture (8 cases), loosened screws (5 cases), gingival recession (4 cases), and gingival enlargement (1 case). 3. Marginal bone loss, 1 year after prosthesis placement, was significant(P<0.05) in the group that underwent bone grafting, however no difference in annual resorption rate was observed afterwards. 4. Marginal bono loss, 1 year post-placement, was greater in cantilever-type prostheses than in centric pontic protheses (P<0.05). 5. Marginal bone loss was more pronounced in posterior regions compared to anterior regions (P<0.05). 6. The degree of marginal bone loss was proportional to the length of the pontic (P<0.05). Conclusion: The success rate of implant-supported fixed partial dentures, including marginal bone loss, was satisfactory in the present study. Factors influencing marginal bone loss included whether bone graft was performed, location of the pontic (s), location of the surgical area in the arch pontic span. Long-term evaluation is necessary for implant-supported fixed partial dentures, as are further studies on the relationship between functional load and the number of implants to be placed.