• Title/Summary/Keyword: temperature zone

Search Result 1,877, Processing Time 0.025 seconds

Comparative Study on Facial Skin Conditions Before and After Washing Face with Placenta CP Soap (자하거 저온숙성비누의 세안전·후 안면피부상태 비교연구)

  • Jin Suk Koo
    • The Korea Journal of Herbology
    • /
    • v.38 no.2
    • /
    • pp.35-41
    • /
    • 2023
  • Objectives : Washing face is the first step in skin beauty and health. I wanted to study the cleansing effect by using Placenta cp (cold process) soap. The skin condition is greatly influenced by the external environment such as lifestyle, drinking, smoking, and stress etc. I tried to measure the skin change state without environmental factors. Methods : In order to examine the effect before and after washing face under the same conditions, the same water and towel were used in the same place. The skin test was performed before and 10 minutes after washing. As a control group, a case of washing with water and foam cleanser. I compared and analyzed three cases: water washing, F/C (foam cleanser) washing, and Placenta cp soap washing. Results : In the case of water washing, it was significantly reduced in pores and increased in facial temperature. In the case of F/C washing, the facial temperature was significantly increased, but the decrease in moisture. In the case of washing with Placenta cp soap, significant reductions in T-zone and U-zone oil content, reduction in pore size, and increase in facial skin temperature were observed. Conclusion : In the case of Placenta cp soap, it is thought to be suitable for oily skin type, because of significant decrease in T-zone and U-zone oil content. It is thought to have the effect of increasing blood circulation in the facial skin and to reduce pores for oily skin types.

The CO2 Reduction Potential Calculation through the Urban Park Construction

  • Lee, Eun Yeob;Kang, Myung Soo;Kim, Jong Kon
    • KIEAE Journal
    • /
    • v.14 no.2
    • /
    • pp.87-98
    • /
    • 2014
  • This study is to identify quantitatively the function of carbon dioxide emissions reduction due to temperature and energy reduction according to direct carbon dioxide storage, shade provision, and evaportanspiration of urban park. According to the result of study, landscape tree indicated high carbon dioxide storage effect compare to bush, in which broadleaf tree indicated higher storage function than coniferous tree. It is believed to be the storage of carbon dioxide can be increased by increasing the composition rate of forest plants in the urban park. According to the direct estimation result of carbon dioxide storage in terms of example area, storage of carbon dioxide is estimated to be "seoul a zone" $476,818.8kg{\cdot}CO_2/m^2yr$, "anyang b zone" $186,435.7{\cdot}CO_2/m^2yr$, "daejeon c zone" $262,826{\cdot}CO_2/m^2yr$, "kwangju d zone" $231,657.8{\cdot}CO_2/m^2yr$. The carbon dioxide storage per unit area estimated to be "seoul a zone" $3.4{\cdot}CO_2/m^2yr$, "anyang b zone" $5.0{\cdot}CO_2/m^2yr$, "daejeon c zone" $2.6{\cdot}CO_2/m^2yr$, "kwangju d zone" $5.6{\cdot}CO_2/m^2yr$. The result of indirect carbon dioxide reduction effect estimated to be "seoul a zone" $291,603.4{\cdot}CO_2/m^2yr$, "anyang b zone" $165,462.4{\cdot}CO_2/m^2yr$, "daejeon c zone" $141,719.2{\cdot}CO_2/m^2yr$, "kwangju d zone" $154,803.4{\cdot}CO_2/m^2yr$. Carbon dioxide reduction potential amount through the urban park was increased to 1.6 times to 1.8 times when calculated to the indirect effect.

An Investigation of High Temperature Creep Phenomena by the Method of Caustics (코스틱스방법을 이용한 고온 크리프 파괴현상에 관한 연구)

  • 이억섭;홍성경
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2543-2553
    • /
    • 1994
  • Caustics method has been applied successfully to determine the fracture parameters such as stress intensity factor and the J-integral for elastic and/or elastic-plastic stress field around the crack tip. For stress fields at the vicinity of crack tip in the creep domain, no experimental report concerning fracture mechanics parameters by using the caustics method has been published up to date. This study investigated creep behavior at the vicinity of crack tips at high temperature($175^{\circ}C$) and attempted to determine of proper fracture parameters for A1 5086 H24 specimens by using the caustics method. The results obtained from the limited experimental investigation are as follows; $J_{th}/J_{caus}$ is found to approach to 1 more rapidly than $K_{th}/K_{caus}$ does during incipient period(within 80 minutes). It is confirmed that experimental $K_{caus}$ approached to theoretical $K_{th}$ after 80 minutes by analyzing the ratio of $K_{th}$ to $K_{caus}$. Unlike the case of room temperature, it is confirmed experimentally that caustics diameter enlarged gradually even the distance between specimen and screen keeps constant. It showed that initial curve of the caustics was initially located in the plastic zone, but it grew out rapidly into the elastic zone for Al 5086 H24 at $175^{\circ}C$. It is confirmed that caustics is a function of time, temperature and distance between specimen and screen at high temperature.

Single Crystal Growth of GaAs by Single Temperature Zone horizontal Bridgman(1-T HB) Method (단일 온도대역 수평 Bridgman(1-T HB) 법에 의한 GaAs 단결정 성장)

  • 오명환;주승기
    • Korean Journal of Crystallography
    • /
    • v.7 no.1
    • /
    • pp.73-80
    • /
    • 1996
  • The single crystal growth has been carried out with the newly designed 1-T HB(single temperature zone horizontal Bridgman) system for GaAs crystals of 2 inch diameter doped with Si, Zn or undoped. With this method, incidence probability of single crystallinity was shown to be 0.73. Lattice defects evaluated from EPD(etch pit density) measurement were in the range of 5,000-20,000/cm2, dependent upon the doping condition. For the undoped GaAs crystals, carrier concentrations from the Hall measurement were ∼1×1016/cm3 at the seed part, which were less than half the concentrations of double of triple temperature zone(2-T, 3-T) HB grown crystals. By the 1-T HB method, therefore, GaAs crystals can be grown successfully with better yield and higher purity.

  • PDF

Factors Affecting Temperature of Urban Parks (도시공원의 기온에 영향을 미치는 요인)

  • 윤용한;송태갑
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.2
    • /
    • pp.39-48
    • /
    • 2000
  • The purpose of this study is to investigate the factors affecting temperature of urban parks to grasp the relationship between the land coverage in open space as well as the forest condition and decreasing city temperature by difference of purposed are. Futhermore, this research interpreted the relationship between wind direction, air temperature, the land coverage of the green space, the number of tree, green volume, height of tree and the mitigation of city temperature with the revolution analysis. The result of this study is that cool air in open space move leeward and decreasing city temperature is influenced by the difference of the land coverage in open space. Specifically, in order of the arbo $r_{-a}$rbor in the forest zone, the increase of the number of trees was related with temperature surrounding significantly. This study found that the use possibility of the green volume was recognized as the index of the green volume relative to air temperature surrounding. Green space of the city control area is more effective decreasing temperature than that of housing zone.

  • PDF

A Correlation Concentration of Contaminated Groundwater with Volatilization Coefficient (오염지하수 TCE 농도와 휘발계수와의 관계)

  • 이창수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.266-269
    • /
    • 2000
  • To understand the gaseous behaviour of volatile organic compounds in the unsaturated zone, their volatilization coefficient k$_{Lg}$ is evaluated. An experiment is conducted to examine the dependence of k$_{Lg}$ on the concentration of the dissolution, presence of unsaturated zone and depth of the unsaturated zone. The results show that the volatilization coefficient is not dependent on the concentration under the constant temperature and pressure. It is also find that k$_{Lg}$ depends on the presence of the unsaturated zone rather than its depth.depth.

  • PDF

Temperature Effects on Fracture Toughness Parameters for Pipeline Steels

  • Chanda, Sourayon;Ru, C.Q.
    • International journal of steel structures
    • /
    • v.18 no.5
    • /
    • pp.1754-1760
    • /
    • 2018
  • The present article showcases a temperature dependent cohesive zone model (CZM)-based fi nite element simulation of drop weight tear test (DWTT), to analyse fracture behavior of pipeline steel (PS) at different temperatures. By co-relating the key CZM parameters with known mechanical properties of PS at varying temperature, a temperature dependent CZM for PS is proposed. A modified form of Johnson and Cook model has been used for the true stress-strain behavior of PS. The numerical model, using Abaqus/CAE 6.13, has been validated by comparing the predicted results with load-displacement curves obtained from test data. During steady-state crack propagation, toughness parameters (such as CTOA and CTOD) were found to remain fairly constant at a given temperature. These toughness parameters, however, show an exponential increase with increase in temperature. The present paper offers a plausible approach to numerically analyze fracture behavior of PS at varying temperature using a temperature dependent CZM.

The Low NOx Characteristics of the Primary Zone in Micro Turbine Combustor (마이크로 터빈 연소기 주연소영역의 저 NOx 생성 특성)

  • Son, M.G.;Ahn, K.Y.;Lee, H.S.;Yoon, J.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.155-160
    • /
    • 2001
  • The low NOx characteristics have been investigated to develop the combustor for micro turbine. The lean premixed combustion technology was applied to reduce the NOx emission. The test was conducted at the condition of high temperature and ambient pressure. The combustion air which has the temperature of $450\sim650K$ were supplied to the combustor through the air preheater. The temperature and emissions of NOx and CO were measured at the exit of combustor, The exit temperature and NOx were increased and CO was decreased with increasing inlet air temperature. The premixing chamber can be operated very lean condition of equivalence ratio around 0.35. The NOx was decreased with decreasing the equivalence ratio. The CO was decreased with decreasing the equivalence ratio, but the CO was increased with decreasing the equivalence ratio below 0.4. But, at the very lean condition of equivalence ratio below 0.35 both NOx and CO were increased because of the flame unstability. The NOx was decreased and CO was increased with increasing inlet air flowrate. This results can be used to determine the size of combustor. Consequently the performance of combustor shows the possibility of the application to the gas turbine system.

  • PDF

Development of Heat-treatment Furnace with Maximum Uniform Zone using Gas-phase Condensing Heat Exchange (기상응축 열교환을 이용한 고정밀 등온 가열로 개발)

  • Hong, Hyun-Seon;Kong, Man-Seek;Kang, Hwan-Kook
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.22 no.3
    • /
    • pp.162-168
    • /
    • 2009
  • A horizontal tube furnace with a wide uniform-temperature zone was developed using isothermal characteristics of a heat pipe. The heat pipe heating system consists of a concentric annular shaped stainless-steel container, sodium as a working fluid and a screen mesh wick structure. The performance test of the heat pipe revealed that temperature changes along seven consecutive positions of the heat pipe outer wall were less than${\pm}0.1^{\circ}C$, thereby ensuring the high isothermal property. The isothermal property of the heat pipe-adapted tube fumace was investigated and compared to a conventional non-heat pipe type tube furnace. The temperature distribution measurement showed that the uniform temperature zone, in which temperature change is less than${\pm}$1$^{\circ}$C, of the heat pipe employed tube furnace system was about three times longer compared to the conventional tube furnace system.

Prediction of Laminar Flame Thickness of Ethanol-Air Pre-Mixture (에탄올-공기 예혼합기의 층류 화염두께 예측)

  • Kwon, Soon-Ik;Kim, Sang-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1417-1423
    • /
    • 2004
  • The thickness of laminar flame and preheat zone was computed from equation with burning velocity and the temperature profile, which is obtained by using premix code of Chemkin program for ethanol-air mixture. The computations were carried out under the unburned gas pressure 0.5bar-30bar and temperature of 300k-700K at 1.0. A difference flame thickness showed between temperature profile and equation with burning velocity. The ratio of flame thickness derived from the equation was about 45∼65% of the temperature profile, and the thickness of preheat zone was about 67.1% of the flame thickness. The flame thickness was decreased by increasing the pressure and temperature, but the effect of pressure is more significant than the effect of temperature on the flame thickness. The flame thickness was predicted by using the following equation. X(mm) = $X_{st}$ (T/300)$^{-0}$.65/(P)$^{-0}$.68/ (0.5bar$\leq$P$\leq$30bar, 300K$\leq$T$\leq$700K)K)