외기온이 온실의 차광효과에 미치는 영향 (The influence of outside temperature upon shading effect in greenhouses)

  • 이석건;이종원;이현우
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.243-249
    • /
    • 1998
  • This study was conducted for analyzing the influence of outside temperature upon shading effect of greenhouses by simulation. The simulation program was tested by comparing predicted values to measured values and applied the Korean standard wide span glasshouse. The shading effect according to the variation of outside temperature was different by shading method and rate. The increasing rate of inside temperature with different shading rate was nearly propotional to the increasing value of outside temperature. The outside shading effect was a little better than inside shading.

  • PDF

단열재에 따른 저온양봉사 내부의 온.습도변화 (The Variations of Temperature and Humidity with the Insultor Materials in Wingtering Beehouse)

  • 이석건;김란숙;이현우;이종원
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.424-428
    • /
    • 1999
  • The simulation and experiments were conducted to anlayzed the vaiation of the temperature and humicity in the wintering beehouses which had two kinds of the insulator materials of urethane foam and sandwich panel individually . It was found that inside temperature of sandwich panel beehouse was similar to the urethane foam at the same outside temperature by the simulation results. The variation of the inside temperature and humidity for the urethane foam was less than the sandwich panel.

  • PDF

다중회귀분석을 이용한 임하호 유입하천의 수온예측 (Water-Temperature Prediction of Streams Entering into Imha Reservoir using Multi-Regnssion Method)

  • 이용곤;이상욱;고덕구
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.919-925
    • /
    • 2006
  • The regression models for the water temperatures of Ban Byeon Stream and Yong Jeon stream were developed using multi-regression method. It was also investigated that the applicability of the stream temperature prediction to two-dimensional numerical simulation to predict the vertical water temperature in Imha Reservoir. Air temperature and dew point as independent variables were selected to be applicable to cases with the different variation of flow rates. The data division of water temperature using a cutoff flow rate of $20m^3/s$ was found to reduce the prediction error of the stream temperature. The mean absolute percent error of the numerical simulation results of the vertical water temperature in Imha Reservoir using the regression models was 11%, which was only 4.3% lager than the simulation result using the measured stream temperature. Therefore, the regression models of the stream temperatures using multi-regression method applied in this study could be applied to predict the vertical water temperature in Imha Reservoir with a good accuracy.

Numerical simulation of a regenerative thermal oxidizer for volatile organic compounds treatment

  • Hao, Xiaowen;Li, Ruixin;Wang, Jiao;Yang, Xinfei
    • Environmental Engineering Research
    • /
    • 제23권4호
    • /
    • pp.397-405
    • /
    • 2018
  • As regulations governing the control of volatile organic compounds (VOCs) have become increasingly stringent in China, regenerative thermal oxidizers (RTOs) have been more frequently applied in medium- and high-concentration VOCs treatments. However, due to the lack of existing RTO-related research, experience remains a dominant factor for industrial application. This paper thus aimed to establish a model for industrial RTOs, using a transient simulation method and thermal equilibrium model to simulate the internal velocities and temperature distributions of an RTO across multiple cycles. A comparison showed an error of less than 5% between most correlating simulated and experimental measurement points, verifying that the simulation method was accurate. After verification, the velocity and temperature fields inside the RTO were simulated to study the uniformity of temperature and velocity within the packed beds: both fields displayed high uniformity after gas flowed through the honeycomb regenerator. The effects of air volume, VOCs concentrations, and valve switching times on the oxidation chamber temperature, RTO outlet temperature, and thermal efficiency (as well as their averages) were studied. The VOCs removal rate in this study was constantly above 98%, and the average thermal efficiency reached 90%.

Simulation of impact toughness with the effect of temperature and irradiation in steels

  • Wang, Chenchong;Wang, Jinliang;Li, Yuhao;Zhang, Chi;Xu, Wei
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.221-227
    • /
    • 2019
  • One of the important requirements for the application of reduced activation ferritic/martensitic steel is to retain proper mechanical properties in irradiation and high temperature conditions. In order to simulate the impact toughness with the effect of temperature and irradiation, a simulation model based on energy balance method consisted of crack initiation, plastic propagation and cleavage propagation stages was established. The effect of temperature on impact toughness was analyzed by the model and the trend of the simulation results was basicly consistent with the previous experimental results of CLAM steels. The load-displacement curve was simulated to express the low temperature ductile-brittle transition. The effect of grain size and inclusion was analyzed by the model, which was consistent with classical experiment results. The transgranular-intergranular transformation in brittle materials was also simulated.

강제 재생 방식 DPF 내부의 온도 분포 특성에 관한 수치해석 (Numerical Analysis on the Characteristics of Temperature Distribution in an Active Regeneration DPF Type)

  • 박성천;이한성
    • 한국기계기술학회지
    • /
    • 제13권2호
    • /
    • pp.55-61
    • /
    • 2011
  • This study analyzed on the characteristics of temperature distribution in an active regeneration DPF using computer simulation. In order to verify the boundary condition of analysis, results of temperature distribution in DPF are compared between experimental and computer simulation. Using this boundary condition, temperature distribution and filter's durability in DPF analyzed according to various operating conditions. The results of computational analysis are agreed well with experimental ones from the tendency of temperature distribution of axis and radius direction. The temperature increases and the axial temperature gradients in DPF according to velocity of exhaust gas are lowered as the high velocity of exhaust gas. But the temperature gradients of radius direction at exit side in DPF are grown as the high velocity of exhaust gas. The results according to inlet temperature of exhaust gas show that the increase ratios of temperature in DPF are grown as the high temperature of exhaust gas.

Simulation of Wheat Circulating Cross-flow Dryer

  • Kim, Oui-Woung;Kim, Hoon;Kim, Woong;Lee, Hyo-Jai;Han, Jae-Woong
    • Journal of Biosystems Engineering
    • /
    • 제40권3호
    • /
    • pp.232-237
    • /
    • 2015
  • Purpose: In Korea, wheat is dried using circulating cross-flow grain dryers. However, there is no research on wheat drying which can be utilized for the dryers. Therefore, this study developed and evaluated a simulation of the circulating cross-flow dryer, and examined the effects of various factors on drying performance. Methods: The simulation program was developed using drying models and was evaluated against wheat-drying experiments with a dryer having a 30-ton capacity. The influence of drying temperature, air volume, and grain falling rate on drying performance were examined through the simulation. Results: The experimental results validated the simulation program by showing the same root mean square error (RMSE) for moisture content (0.286%) and drying rate (0.056%/h) in both the experimental data and the simulation values. The appropriate wheat-drying parameter values, considering drying conditions, were determined to be $50^{\circ}C$ for drying temperature, $500m^3/min$ for air volume, and a grain falling rate of $36.0m^3/h$. Conclusions: The developed simulation program for circulating cross-flow dryers analyzed the influences of performance factors such as drying temperature, air volume, and falling rate on drying performance.

HP LED의 열거동형상 분석을 위한 thermal simulation

  • 이승민;양종경;이현희;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.191-191
    • /
    • 2009
  • In this paper, we have confirmed the temperature of LED chip and McPCB with thermal simulation program which is CFDedign V10 for analysis the thermal flow of HP LED package. we have known that the heat from LED chip is transferred through heat slug to copper layer of McPCB. the temperature of LED chip shows 85.11 [$^{\circ}C$], which shows the temperature gap of 7.52 [$^{\circ}C$] against McPCB. the gap of temperature affect reliability of the wire bonding and die attachment. therefore, copper layer of heat slug on the McPCB should designed with the largest dimension.

  • PDF

냉.온열 동시 제조시스템의 성능분석(I)-Simulation (Performance Analysis of Simultaneous Heating & Cooling Water Making System(I)-Simulation)

  • 박성룡;박준택;안영훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.266-271
    • /
    • 2001
  • In this study, the performance of the simultaneous heating & cooling water making system using R134a was investigated by simulation. The most important effect upon heating COP was intermediate pressure depending on input water temperature. With the input water temperature of $10^{\circ}C\;and\;20^{\circ}C$, optimum intermediate pressure were 923 and 1040kPa, respectively. At that optimum intermediate pressure, the maximum heating COP of the system operated between $0^{\circ}C$ evaporating temperature and $70^{\circ}C$ condensing temperature were 4.15 and 3.83. With installation of the subcoolers in high or low pressure section, the system COP was increased by reducing the refrigerant mass flow rate. Under the optimum pressure and $10^{\circ}C$ input water temperature, it was found that heating COP was maximized when the low-subcooler and high-subcooler capacity rate were taken by 14% and 13%, respectively.

  • PDF

용융탄산염형 연료전지의 스택구조와 온도특성 (Temperature Characteristics of the Molten Carbonate Fuel Cell Stack)

  • 이충곤;안교상;박성연;서혜경;임희천
    • 한국수소및신에너지학회논문집
    • /
    • 제15권1호
    • /
    • pp.54-61
    • /
    • 2004
  • Temperature characteristics in a stack of molten carbonate fuel cell (MCFC) have been investigated with simulation based on the computational fluid dynamics (CFD) codes and experimental way. The MCFC has generally two stack structures when the natural gas is used as fuel; one is the external reforming type and the other is internal reforming type. Computer simulation at the external reforming stack suggests that the maximum temperature in the stack depends on the gas flow length. The 2 kW MCFC stack with 25 cm gas flow length showed about $675^\circ{C}$ of maximum temperature.