• 제목/요약/키워드: temperature shifting

검색결과 85건 처리시간 0.024초

점탄소성 모델을 이용한 ETFE 막재의 장기 크리프 거동 예측기법 연구 (Prediction Method of Long Term Creep Behavior for ETFE Foil by Using Viscoelastic-Plastic Model)

  • 김재열
    • 한국공간구조학회논문집
    • /
    • 제14권3호
    • /
    • pp.93-100
    • /
    • 2014
  • Ethylene Tetrafluoroethylene (ETFE) has been widely used in long-span buildings because of its light weight and high transparency. This paper studies the short and long term creep behaviour of ETFE foil. A series of short-term creep and recovery tests were performed, in which the residual strain was observed. A long-term creep test of the ETFE foil was also performed over 110 days. A viscoelastic-plastic model was then established to describe the short-term creep and recovery behaviour. The model contains a traditional multi-Kelvin part and an added steady-flow component to represent the viscoelastic and viscoplastic behaviour, respectively. The model successfully fit the data for three stresses and six temperatures. Additionally, time-temperature equivalency was adopted to predict the long-term creep behaviour of ETFE foil. Horizontal shifting factors were determined from the process of shifting creep-curves at six temperatures. The long-term creep behaviours at three temperatures were predicted. Finally, the long-term creep test showed that the short-term creep test at identical temperatures insufficiently predicted additional creep behaviour, and the long-term test verified the horizontal shifting factors derived from the time-temperature equivalency.

A Comparison of the Dielectric Behavior of Aromatic and Aliphatic Polyurethanes in Relation to Transitional Phenomena

  • Kim, Chy Hyung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권4호
    • /
    • pp.211-216
    • /
    • 2017
  • The dielectric properties of two polyurethanes (PUs) with different hard segments, i.e., aromatic methylene di-p-phenyl diisocyanate (MDI) and aliphatic hexamethylene diisocyanate (HDI), were investigated in the temperature range of -100 to $100^{\circ}C$ and in the frequency range of 1 Hz to 3 kHz. The ${\alpha}$-relaxations induced by the glass transition of the equivalent soft segments in the two PUs occurred at relaxation times of ${\tau}=3.46{\times}10^{-3}s$ for MDI-PU and ${\tau}=3.39{\times}10^{-2}s$ for HDI-PU at $-20^{\circ}C$, in accord with the temperature-frequency superposition principle, resulting in similar shifting factors. However, different I-relaxations were observed for the two PUs. The I-relaxation of MDI-PU occurred due to the mobility of the chain extenders near $80^{\circ}C$ with a slower shifting rate than the ${\alpha}$-relaxation. On the other hand, I-relaxation arising from both the extender and the unconstrained hard segments of HDI-PU occurred at $70{\sim}100^{\circ}C$, indicating complicated dielectric behavior due to partial interaction with the ${\alpha}$-relaxation at high frequencies. Thus, the I-relaxation of HDI-PU did not follow the superposition principle. The dielectric behaviors of the PUs were mainly influenced by their phase transitions, which were affected by the structure and components of the materials.

자동변속기의 변속특성시뮬레이션을 위한 HILS시스템 개발 (A Development of Hardware-in-the-Loop Simulation System of Automatic Transmission for the Simulation of Shifting Characteristics)

  • 정규홍;이교일
    • 한국자동차공학회논문집
    • /
    • 제9권6호
    • /
    • pp.143-151
    • /
    • 2001
  • During the past several years, the major interests of car manufacturers in development of automatic transmission were in durability and shift quality. However, a large number of researches for improving shift quality that are based on dynamic characteristics of shifting mechanism have been rarely adopted in the developing process because it is quite difficult to predict the shifting performance from the dynamics simulation. One of the important reasons for the difference between simulation results and experiments arises from the automatic transmission hydraulic system that consists of many valves with high order model and shows a lot different dynamics to temperature variation. In this work, hardware-in-the-loop simulation system for automatic transmission was developed f3r improving the accuracy of simulated result by combining the real-time simulation model with the real hydraulic system. The real-time simulation for automatic transmission model excluding hydraulic system is executed with TI's TMS320C31 DSP and the interfacing board which includes 12bit A/D, PWM signal generator and driver, serial driver ,etc is designed for acquiring the simulation data and signal interface with hydraulic system. We verified the proper operation and correctness of shifting result by comparing the off-line simulation result with that of HILS and experimental result which was performed on transmission dynamometer driven by electric motor.

  • PDF

온도에 따른 InZnP/ZnSe/ZnS (핵/다중껍질) 양자점의 형광 특성 변화 (The Effect of Temperature on the Photoluminescence Properties of the InZnP/ZnSe/ZnS (Core/Multishell) Quantum Dots)

  • 손민지;정현성;이윤기;구은회;방지원
    • 한국전기전자재료학회논문지
    • /
    • 제31권7호
    • /
    • pp.443-449
    • /
    • 2018
  • We investigated the temperature-dependent photoluminescence spectroscopy of colloidal InZnP/ZnSe/ZnS (core/shell/shell) quantum dots with varying ZnSe and ZnS shell thickness in the 278~363 K temperature range. Temperature-dependent photoluminescence of the InZnP-based quantum dot samples reveal red-shifting of the photoluminescence peaks, thermal quenching of photoluminescence, and broadening of bandwidth with increasing temperature. The degree of band-gap shifting and line broadening as a function of temperature is affected little by shell composition and thickness. However, the thermal quenching of the photoluminescence is strongly dependent on the shell components. The irreversible photoluminescence quenching behavior is dominant for thin-shell-deposited InZnP quantum dots, whereas thick-shelled InZnP quantum dots exhibit superior thermal stability of the photoluminescence intensity.

SimulationX를 이용한 트랙터 PST 변속 충격 최소화 연구 (Minimization of Shifting Shock of Tractor PST using SimulationX)

  • 엄태호;이철희
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권3호
    • /
    • pp.36-42
    • /
    • 2018
  • Agricultural tractors require frequent shifting to improve operation efficiency, and PST (Powershift Transmission) is considered as a suitable transmission. However, due to the inherent characteristics of the PST, shocks arise during shifting, which imparts a negative effect on the operator. Therefore, in order to improve the transmission performance of the tractor PST, researches on various methods including the hydraulic system circuit, the engine input speed control, and the mechanical system of the transmission are steadily being conducted. In this study, in order to reduce the impact of PST on a shift based on SimulationX software, we analyzed the characteristics of the input signal of PCV (Pressure Control Valve) through sensitivity analysis and verified the simulation model through actual vehicle test. Optimization was performed for minimizing the shift shock for some of the parameters of the input signal at constant temperature and RPM conditions.

Cupric Ion Species in Cu(II)-Exchanged Mesoporous MCM-41 Gallosilicate Determined by Electron Spin Resonance Studies

  • Kim, Jeong-Yeon;Yu, Jong-Sung
    • 한국자기공명학회논문지
    • /
    • 제1권2호
    • /
    • pp.126-140
    • /
    • 1997
  • Mesoporous MCM-41 gallosilicate material was synthesized through shifting through shifting gallosilicate polymer equilibrium towards a MCM-41 phase by addition of acid. The location of Cu(II) exchanged into MCM-41 and its interaction with various adsorbate molecules were investigated by electron spin responance and electron spin echo modulation spectroscopies. It was found that in the fresh hydrated material, Cu(II) is octahedrally coordinated to six water molecules. This species is located in a cylindrical channel and rotates rapidly at room temperature. Evacuation at room temperature removes three of these water molecules, leaving the Cu (II) coordinated to three water molecules and anchored to oxygens in the channel wall. Dehydration at 45$0^{\circ}C$ produces one Cu (II) species located in the inner surface of a channel as evidenced by broadening of its ESR lines by oxygen. Adsorption of polar molecules such as water, methanol and ammonia on dehydrated CuNa-MCM-41 gallosilicate material causes changes in the ESR spectrum of Cu (II), indicating the complex formation with these adsorbates. Cu (II) forms a complex with six molecules of methanol as evidenced by an isotropic room temperature ESR signal and ESEM data like upon water adsorption. Cu(II) also forms a complex containing four molecules of ammonia based on resolved nitrogen superhyperfine interaction.

  • PDF

저온 주사 레이저 현미경(LTSLM)을 이용한 YBCO 초전도 선재의 국소적 임계 온도 및 전류 밀도 분포 분석 (Distribution Analysis of Local Critical Temperature and Current Density in YBCO Coated Conductors using Low-temperature Scanning Laser Microscopy)

  • 박상국;조보람;이형철
    • Progress in Superconductivity
    • /
    • 제12권1호
    • /
    • pp.17-22
    • /
    • 2010
  • Distribution of local critical temperature and current density in $YBa_2Cu_3O_{7-\delta}$ (YBCO) coated conductors was analyzed using a Low-temperature Scanning Laser Microscopy (LTSLM). We prepared YBCO coated conductors of various bridge types to study the spatial distribution of critical temperature and current density in single and multi bridges. An LTSLM system was modified for a detailed two-dimensional scan without shifting of the sample. We observed a spatial distribution of the critical temperature from the bolometric response, which arises from a focused laser beam at the sample near the superconducting transition. Also we studied the relation between the critical temperature and the current density.

KSR-III 로켓 노즐의 열화학적 성능해석 (Thermochemical Performance Analysis of KSR-III Rocket Nozzle)

  • 최정열;최환석;김영목
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2001년도 제22회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.90-98
    • /
    • 2001
  • Characteristics of high temperature rocket nozzle flow is discussed along with the aspects of computational analysis. Three methods of nozzle flow analysis, frozen-equilibrium, shifting-equilibrium and non-equilibrium approaches, were discussed, those were coupled with the methods of computational fluid dynamics code. A chemical equilibrium code developed for the analysis of general hydrocarbon fuel was coupled with three approaches of nozzle flow analysis. The approaches were used for the performance prediction of KSR-III Rocket, and compared with the theoretical results from NASA CEA (Chemical Equilibrium with Applications) code.

  • PDF

Low Power and Small Area Holding Latch with Level Shifting Function Using LTPS TFTs for Mobile Applications

  • Choi, Jung-Hwan;Kim, Yong-Jae;Ahn, Soon-Sung;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1283-1286
    • /
    • 2006
  • A holding latch with level shifting function is proposed for power and cost effectiveness with low temperature polycrystalline silicon technology on the glass backplane. Layout area and power consumption of the proposed circuit are reduced by 10% and 52% compared with those of the typical structure which combines a static D-latch and a cross coupled level shifter for 2.2" qVGA panel, respectively.

  • PDF

Dielectric Relaxation of Siloxane-Epoxy Copolymers

  • Kim, Chy-Hyung;Shin, Jae-Sup
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권3호
    • /
    • pp.413-416
    • /
    • 2002
  • The dielectric responses of 10 and 40 wt% siloxane-epoxy copolymers were investigated in temperature range near the glass transition of polydimethylsiloxane at which the dielectric transitions were also observed. On the other hand, the pure epoxy did not show any dielectric transition in measurement temperature range -90 to 150 $^{\circ}C.$ The experimental data showed that for the copolymer investigated, the temperature-frequency super-position principle could be applied to the dielectric response. From the Cole-Cole equation, the dielectric relaxation of the 10 wt% siloxane near the glass transition temperature resulted in a broad distribution with ${\beta}=$ 0.19 and the relaxation time at -70 $^{\circ}C$ was 5.3 ${\times}$ $10^{-2}$s. The glass transition temperature, 188 K, was estimated by using WLF relation, which was consistent with the data presented in experiment.