• 제목/요약/키워드: temperature resistance

검색결과 5,425건 처리시간 0.028초

병렬로 접속된 저항체에서 저항온도계수의 거동 (Behavior of the Temperature Coefficient of Resistance at Parallelly Connected Resistors)

  • 이선우
    • 한국전기전자재료학회논문지
    • /
    • 제31권2호
    • /
    • pp.98-101
    • /
    • 2018
  • In this paper, we discuss the fabrication of metal alloy resistors. We connected them in parallel to estimate their resistance and temperature coefficient of resistance (TCR). The fabricated resistors have different resistances, 5 and $10{\Omega}$ and different TCRs, 50 and $200ppm/^{\circ}C$. Each resistor was confirmed to have the correct atomic composition through the use of energy dispersive X-ray (EDX). The resistors' electrical properties were confirmed by measuring resistance and TCR. The resistance and TCR of the resistors connected in parallel were estimated through the increase in resistance due to the increase in temperature, and were compared with the measured values. We are confident that this TCR estimation technique, which uses the increase in resistance due to temperature, will be very useful in designing and fabricating resistors with low and stable TCR.

백금박막 측온저항체 온도센서의 개발 (The Development of Platinum Thin Film RTD Temperature Sensors)

  • 노상수;최영규;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.152-155
    • /
    • 1996
  • Platinum thin films were deposited on $Al_2$O$_3$substrate by DC magnetron sputtering for RTD(Resistance Thermometer Devices) temperature sensors. We made Pt resistance pattern on $Al_2$O$_3$substrate by lift-off method and fabricated Pt-RTD temperature sensors by using W-wire, silver epoxy and SOG(spin-on-glass). In the temperature range of 25~40$0^{\circ}C$, we investigated TCR(temperature coefficient of resistance) and resistance ratio of Pt-RTD temperature sensors. TCR values were increased with increasing the annealing temperature, time and the thickness of Pt thin films. Resistance values were varied lineally within the range of measurement temperature. At annealing temperature of 100$0^{\circ}C$, annealing time of 240min and thin film thickness of 1${\mu}{\textrm}{m}$, we obtained Pt-RDT TCR value of 3825ppm/$^{\circ}C$ closed to the Pt bulk value.

  • PDF

PTCR 나노 복합기능 소재의 전류 차단 특성 연구 (PTCR Characteristics of Multifunctional Polymeric Nano Composites)

  • 김재철;박기헌;서수정;이영관;이성재
    • 폴리머
    • /
    • 제26권3호
    • /
    • pp.367-374
    • /
    • 2002
  • 본 연구에서는 나노 입자의 카본블랙을 결정성 고분자에 분산시켜 특정한 온도에서 저항이 급격하게 증가하는 positive temperature coefficient resistance (PTCR) 특성을 연구하였다. 열가소성 수지를 이용한 PTCR 소재를 열처리에 의하여 고분자의 큐리온도를 조절할 수 있었다. 나노입자 카본블랙이 고분자 구조내에 고르게 분산이 되지 않고, 카본블랙의 함량이 과다하면 negative temperature coefficient resistance (NTCR) 현상이 발생하였다. 카본블랙의 함량과 내부전압을 조절함에 따라 발열 온도를 선정할 수 있었다. 카본블랙의 함량에 따라 전기 전도성이 다르게 나타났으며, 20 wt% 이상에서는 저항이 거의 일정하게 나타난다는 것을 확인하였다. 본 연구에서 제조된 PTCR 소재는 반복적인 가열 냉각에 따른 상온에서의 초기 저항의 변화가 거의 없어 재현성을 확인하였으며, 초기의 낮은 저항에 의한 순간적인 발열에 의하여 저온에서의 PTCR 성능이 향상되었다.

목본식물 형성층 전기저항에 영향을 주는 환경 요인 (Effects of Environmental Factors on the Cambial Electrical Resistance of Woody Plants)

  • 김동욱;김민수;이부용
    • 한국조경학회지
    • /
    • 제35권3호
    • /
    • pp.105-113
    • /
    • 2007
  • This study was conducted to analyze the effects of environmental factors such as soil moisture, light intensity, temperature and humidity on changes in cambial electrical resistance. To improve data quality, cambial electrical resistance was continuously measured at fixed points by using a data logger isolated from alternating current. The relationship between environmental factors and changes in cambial electrical resistance was also analyzed. The results are as follows: 1. Cambial electrical resistance is highly correlated to the temperature of the measured area(r=-0.934). Therefore, temperature compensation is needed to analyze the effects of other environmental factors on cambial electrical resistance changes. 2. If temperature is compensated for, the change of cambial electrical resistance is highly correlated to water vapor pressure(r=-0.836). 3. If temperature and humidity are compensated for, the change of cambial electrical resistance is highly correlated to intensity of light(r=-0.738). 4. Diurnal deviation of soil water potential is not more significantly related than the change of cambial electrical resistance. However, in the long-term, soil water potential and cambial electrical resistance are highly correlated(r=-0.831). This indicates that soil moisture significantly influences the long-term change of cambial electrical resistance.

A Study on Heat Resistance of High Temperature Resistant Coating

  • Zhang, Liping;Wang, Xueying;Zhang, Qibin;Qin, Yanlong;Lin, Zhu
    • Corrosion Science and Technology
    • /
    • 제4권2호
    • /
    • pp.60-63
    • /
    • 2005
  • A high temperature resistant coating has been developed, which is mainly for heavy oil production pipes deserved the serious corrosion. The coating has excellent physical and mechanical performance and corrosion resistance at room and high temperature. In order to simulate the underground working condition of heavy oil pipes, the heat resistance of the high temperature resistant coating has been studied. The development and a study on the heat resistance of the DHT high temperature resistance coating have been introduced in this paper.

CFRP로 보강된 철근콘크리트 휨부재의 내화성능 개선을 위한 실험 (Experiment for the Improvement of Fire Resistance Capacity of Reinforced Concrete Flexural Member Strengthened with Carbon Fiber Reinforced Polymer)

  • 임종욱;서수연;송세기
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.19-27
    • /
    • 2017
  • This paper is a study to improve the fire-resistance capacity of reinforced concrete (RC) members strengthened by fiber-reinforced-polymer (FRP). The fire resistance of the RC members strengthened by FRP was evaluated through high temperature exposure test. In order to improve the fire resistance of the FRP reinforcing method, a fire-proof board was attached to the reinforced FRP surface and then the high temperature exposure test was carried out to evaluate the improvement of the fire resistance performance. It was confirmed that the resistance to high temperature of NSMR could be improved somewhat compared with that of EBR from the experiment that exposed to high temperature under the load corresponding to 40% of nominal strength. When 30 mm thick fire-resistance (FR) board is attached to the FRP surface, the surface of the reinforced FRP does not reach $65^{\circ}C$, which is the glass transition temperature (GTT) of the epoxy until the external temperature reaches $480^{\circ}C$. In particular, when a high performance fire-proof mortar was first applied prior to FR board attachment, the FRP portion did not reach the epoxy glass transition temperature until the external temperature reached $600^{\circ}C$.

내한촉진제의 종류 및 혼입양 변화에 따른 모르터의 강도특성에 관한 연구 (A Study on the Strength Properties of Mortar Under Various Types and Contents of Accelerators for Freezing Resistance)

  • 이상수;원철;박상준;김동석
    • 한국건축시공학회지
    • /
    • 제2권2호
    • /
    • pp.151-156
    • /
    • 2002
  • When fresh concrete is exposed to low temperature, the concrete may suffer frost damage due to freezing at early ages and strength development may be delayed. One of the solution methods for resolve these problems is to reduce freezing temperature of concrete by the use of chemical admixture called Accelerators for freezing resistance. In this study, we investigate the effect on strength development of cement mortar using accelerators for freezing resistance with the variance curing condition. As the result of this study, the mortar using accelerators for freezing resistance show that continuously strength development in curing condition of -5$^{\circ}C$. And compressive strength under the variance temperature condition was higher than constant temperature condition in same maturity.

에폭시 나노컴퍼지트 체적 고유저항의 온도 의존성 (Temperature Dependence of Volume Resistivity on Epoxy Nano-composites)

  • 김창훈;이영상;강용길;박희두;신종열;홍진웅
    • 한국전기전자재료학회논문지
    • /
    • 제24권10호
    • /
    • pp.834-838
    • /
    • 2011
  • This research shows the electrical characteristic using excellent epoxy nano-composite of MgO 5.0 wt% and $SiO_2$ 0.4 wt% in mechanical strength test depending on nano-additive. First of all, volume resistance depending on nano-additive and temperature using high resistance meter (HP. 4329A) by increasing 10, 100, 1,000 V of applying voltage was measured. Moreover, temperature range of $25{\sim}120^{\circ}C$ with virgin sample was tested using TO-9B oven by Ando Company. The result showed that virgin and the samples added with MgO and $SiO_2$ had similar value of volume resistance in low temperature and low electric field region and reduced with slow slope. The nano-composite's volume resistance of sample added with MgO and $SiO_2$ had higher value than virgin sample's volume resistance in high temperature region more than $80^{\circ}C$. Moreover, the slope has steeply reduced. The volume resistance of sample added with MgO 5.0 wt% was $8.38{\times}10^{13}\;{\Omega}{\cdot}cm$ and it was 6.8 times more than virgin sample in high temperature at $120^{\circ}C$. The insulation characteristics were constant although filler has changed in low temperature region. But, in high temperature region, the value of volume resistance of sample with MgO 5.0 wt% was 7.6 times more than the virgin sample's volume resistance.

Effects of Thermal Contact Resistance on Film Growth Rate in a Horizontal MOCVD Reactor

  • Im Ik-Tae;Choi Nag Jung;Sugiyama Masakazu;Nakano Yoshiyaki;Shimogaki Yukihiro;Kim Byoung Ho;Kim Kwang-Sun
    • Journal of Mechanical Science and Technology
    • /
    • 제19권6호
    • /
    • pp.1338-1346
    • /
    • 2005
  • Effects of thermal contact resistance between heater and susceptor, susceptor and graphite board in a MOCVD reactor on temperature distribution and film growth rate were analyzed. One-dimensional thermal resistance model considering thermal contact resistance and heat transfer area was made up at first to find the temperature drop at the surface of graphite board. This one-dimensional model predicted the temperature drop of 18K at the board surface. Temperature distribution of a reactor wall from the three-dimensional computational fluid dynamics analysis including the gap at the wafer position showed the temperature drop of 20K. Film growth rates of InP and GaAs were predicted using computational fluid dynamics technique with chemical reaction model. Temperature distribution from the three-dimensional heat transfer calculation was used as a thermal boundary condition to the film growth rate simulations. Temperature drop due to the thermal contact resistance affected to the GaAs film growth a little but not to the InP film growth.

전기적 접속/접촉부 열화 평가를 위한 수명 온도상승 모델 (Lifetime-Temperature Rise Model for the Evaluation of Degradation in Electric Connections/Contacts)

  • 김정태;김남준
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.55-61
    • /
    • 2002
  • In this paper, 'lifetime-temperature rise model' based on the 'lifetime-resistance model' is theoretically Proposed, in order to find out the evaluation method of degradation and the residual lifetime by use of infrared image camera for electric connections/contacts. Two assumptions have been builded up for the 'lifetime-temperature rise model': one is associated with the linear relationship between the temperature ism ΔK and contact resistance, and the other the functional relationship between the temperature of electric connections/contacts and the operating time presenting in the 'lifetime-resistance model'. To prove the proposed model, experiments have been performed for various electric connections/contacts. From the experimental results, measured values were quite similar to the calculated values, which proved the above-mentioned two assumptions. Therefore, by use of 'lifetime-temperature rise model', it is possible to estimate the trend of degradation and the residual lifetime for electric connections/contacts through the temperature measurements .