• Title/Summary/Keyword: temperature measurement of combustion

Search Result 211, Processing Time 0.021 seconds

Temperature Measurement in Concentric Diffusion Flames by Rapid Insertion Technique (급속 삽입법에 의한 화염 내부 온도 분포 측정)

  • Lee, Gyo-Woo;Chung, Young-Rok;Jurng, Jong-Soo
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.2
    • /
    • pp.75-83
    • /
    • 1999
  • The effect of temperature distributions on soot volume fraction in double-concentric diffusion flames have been investigated experimentally. Using fine thermocouple wires and a rapid insertion mechanism, we have measured temperature without the effect of soot particles attached to the thermocouple junction, which can lower the temperature signal about 100 K by increasing the heat loss from the junction by radiation. The temperature at the flame axis is higher in the double-concentric diffusion flames than in normal co-flow diffusion flames because of the inverse diffusion flame. However, it is almost the same as that at the periphery of normal flames, on which the inverse flame does not have an effect. Thus, the lower soot concentration found in the double-concentric diffusion flame can be explained by the effect of nitrogen diffusion from the central air jet.

  • PDF

The Stream and Exhaust Gas Characteristics for Variation of Exhaust Gas Temperature of Marine Incinerator Ejector (선박용 소각로 이젝터의 배출온도 변화에 따른 유동과 배기특성)

  • 김태한
    • Journal of Ocean Engineering and Technology
    • /
    • v.14 no.2
    • /
    • pp.60-64
    • /
    • 2000
  • An experimental study was performed to investigate the optimal ejector and operating condition of vessel incinerator. Exhaust gas temperature and secondary air which makes vacuum pressure at ejector throat regions were considered as an important factor. According to the measurement of pressure temperature and nitrogen oxides between non combustion and combustion we found the stream and exhaust gas characteristics of incinerator. This results can give us the exhaust gas temperature control system air pollutant reduction method and the optimum ejector design.

  • PDF

The Study on Temperature Measurement for the Standardization of Moxibustion (구법(灸法)의 표준화를 위한 온도 측정 연구(硏究))

  • Kim, Yoon-Hong;Lee, Seung-Ho;Yeo, Su-Jung;Choe, Il-Hwan;Kim, Young-Kon;Lim, Sabina
    • Journal of Acupuncture Research
    • /
    • v.25 no.2
    • /
    • pp.129-138
    • /
    • 2008
  • Objectives : The moxibustion is the method in using the heat stimulation made of attached and burned a moxa or other herbal materials on a healing point or acupuncture point and the chemical stimulation of a resin made from burning them. We need to standardize the characteristics of moxa combustion in order to get more systematic and objective result in operation mechanism and effects and then get more clinical abilities in these fields. Methods : In this study, using of labview system on the moxibustion. 1. we studied relation the size of barley and jujube seed with the moxa cone's peak combustion temperature and then measured and compared the moxa cone's peak combustion temperature by tonification and sedation method. 2. we measured the peak combustion temperature of indirect moxibustion. Results & comclusions : 1. When we measured a direct moxibustion's combustion temperature, the jujube seed sized moxa cone's peak temperature was higher than the barley sized moxa cone's when it burned and the time to peak temperature of the barley sized moxa cone was shorter than the jujube seed sized moxa cone's. 2. When the direct moxibustion was burned by the tonification and sedation method, the sedation method's peak temperature was higher than the tonification method's, the tonification's time to peak temperature was shorter than the sedation method's. 3. When we measured the temperature of the moxa combustion in the kinds of sliced herbal materials, the peak temperature of indirect moxibustion with a ginger when it sliced a 1.3mm size and a 1.5mm size was degreed within $40^{\circ}C$ to $52^{\circ}C$ and the peak temperature of indirect moxibustion with a garlic when it sliced a 1.7mm size was degreed within $46^{\circ}C$ to $62^{\circ}C$.

  • PDF

A Study on Characteristics of Combustion and Thermo Pyrolysis in Co-firing with Pulverized Coal and Wood Biomass (미분탄과 목재 바이오매스 혼합 연료의 연소 및 열분해 특성에 관한 연구)

  • An, Jae-Woo;Ahn, Seong-Yool;Moon, Cheor-Eon;Sung, Yon-Mo;Seo, Sang-Il;Kim, Tae-Hyung;Choi, Gyung-Min;Kim, Duck-Jool
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.2
    • /
    • pp.34-40
    • /
    • 2010
  • The effect of co-firing with pulverized coal and wood biomass on ignition and burn-out temperature was investigated at air and oxy-fuel conditions by thermo gravimetric analyzer(TGA). Three kinds of coal(shenhua, adaro, wira) were selected and mixing ratios of coal and wood biomass was set to 1, 0.5, and 0.8. The ignition temperature depended on the amount of volatile matter of blended fuel, while the burn-out temperature was dominated by the oxidant ingredients. The oxy-fuel condition with an oxygen ratio(Ofr,o) of 0.3 showed similar tendency with air condition in the heat flow measurement. Volatile matter reaction, however, became dominant when oxygen ratio exceeded 0.8 for co-firing combustion of wood biomass and pulverized coal.

Measurement of Ignition Delay Time of Jet Aviation Fuel (혼합 액체 연료인 항공유의 점화지연시간 측정에 관한 연구)

  • Han, Hee Sun;Wang, YuanGang;Kim, Chul Jin;Sohn, Chae Hoon
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.3
    • /
    • pp.35-40
    • /
    • 2017
  • Jet aviation fuel is one of liquid fuel which are used in aircraft engines. Korean domestic jet fuel, called Jet A-1, is tested for measurement of ignition delay time by using a shock tube manufactured recently. The temperature varies from 680 to 1250 K and the pressure and equivalence ratio of Jet A-1/air are fixed 20 atm and 1.0, respectively, for this experiment. The ignition delay time data of Jet A-1 are compared with those of Jet A, which has similar properties to Jet A-1. The behavior of negative-temperature-coefficient (NTC) is observed in the temperature range 750-900 K. In addition, ignition delay time of iso-octane is measured, which is one of the surrogate components for jet aviation fuel. The experimental data are compared and validated with the previous results from the literatures. A surrogate fuel for the present Jet A-1 consists of 45.2% n-dodecane, 32.1% iso-octane, and 22.7% 1,3,5-trimethylbenzene. The predicted ignition delay time for the surrogate agrees well with the measured one for Jet A-1.

A Study on Non-contact Surface Temperature Field Measurement of a Body Immerged in Water Using Thermographic Phosphor Thermometry (열감지인광온도계를 이용한 물에 잠긴 물체 표면 온도장의 비접촉식 측정에 관한 연구)

  • Park, Yoonseong;Cai, Tao;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.3
    • /
    • pp.61-68
    • /
    • 2020
  • Thermographic phosphor (TP) thermometry is a noncontact optical measurement method and has been applied in many fields such as combustion and heat transfer. However, due to the limitation of bonding technology and measurement method, most TP thermometry studies were conducted only on the air environment with water-soluble binders. In this paper, a temperature measurement technology in water using TP is proposed by coatings of manganese activated magnesium fluorogermanate (Mg4FGeO6:Mn4+, MFG) with Polydimethylsiloxane (PDMS). Four MFG-PDMS coatings with different thicknesses were prepared. The lifetime of MFG was not affected by the thickness of the coating as a result of the experiment and analysis of phosphor intensity using a photomultiplier tube. To measure the surface temperature field of an immerged body in water, a cylinder-type cartridge heater was coated with MFG doped PDMS. Transient surface temperature field was successfully measured even the initial temperature is higher than the boiling point of water.

Studies on the Flame Temperature Measurement of the Propagating Flame (전파화염에서의 화염온도측정에 관한 연구)

  • ;;Jeung, In Seuck
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.1 no.4
    • /
    • pp.182-189
    • /
    • 1977
  • The propagating flame temperature of the Propane-Air premixture by using 30.$\mu$ and 50.$\mu$ diameter platinum sensing wires, that is, Two Wires Correction Method, Through the constant volume burining inside the 150mm diameter, 30mm height combustion chamber under the circumstances of the atomospheric pressure, and the room temperature was determined. Also the temperature distribution across High Temperature Region, i.e. Flame Front, and the temperature profile behind the flame the front have been obtained.

Experimental Investigation on Premixed Combustion Characteristics with Suction & Blow Fans (Suction과 blow fan을 이용한 연소기내의 부분 예혼합화염 연소 특성에 관한 실험적 연구)

  • Kang, Ki-Bal;Kim, Dong-Il;Oh, Sang-Heun
    • Journal of the Korean Society of Combustion
    • /
    • v.7 no.2
    • /
    • pp.15-23
    • /
    • 2002
  • We measured emission indices for $NO_x$, CO, temperature and radical characteristics for partially premixied flames formed by suction & blow fans air condition. At sufficiently high levels of partial premixing a double flame structure consisting of a rich premixed inner flame and outer diffusion flame was established similar to that previously observed in premixed flames. $NO_x$, Temperature. CO concentration were experimented with approximately constant air flow rate and decreasing equivalence ratios. The reduction in $NO_x$, and temperature at suction condition as compared with that for blow condition was approximately 20%, but on the contrary, CO emission was increased. In addition, We measured temperature distributions and found that temperature increased continuously with increasing partial premixing. We also estimated CH, $C_2$ radical intensity. CH and $C_2$ radicals provide evidence that, for the present measurement, CH and $C_2$ radicals intensity was associsated with their premixed component. And we observed stronger $C_2$, CH radicals intensity at suction conditions than blow conditions.

  • PDF

A Study on the Development of a Recuperative Burner ( I ) (폐열회수겸용 버너의 설계 기술 개발에 관한 연구 ( I ))

  • Park, Byung-Sik;Kim, Won-Bae;Chung, Dae-Hun;Kim, Yoo
    • Journal of the Korean Society of Combustion
    • /
    • v.1 no.2
    • /
    • pp.1-7
    • /
    • 1996
  • A recuperative, burner in the capacity of 400kW was designed using the design data from the experimental results. Performance tests on this burner were made. The exhaust gas analysis, including NOx, the measurement of the flame temperature and velocity in the recuperative burner were the main topics of hot combustion tests. Design data from the experimental results are the gas velocity, air velocity, the tip location of gas nozzle and the dimension of furnace. In view of uniform temperature distribution and thermal efficiency, it is appropriate to maintain the furnace pressure at 2-3mmAq.

  • PDF

Pool Combustion of Iso-Propanol Fuel including IPA and PCBs in different Type Vessels

  • An Suk-Heon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.102-108
    • /
    • 2006
  • On the refutation demanded for a control of various toxic substances. PCBs(poly chlorinated biphenyl) has a fatal poisonous matter in the ecosystem and the environmental pollution as it Is a kind of stable chemical substance. Especially, the gross Product of PCBs is estimated at about one million tonnage all over the world. However it is kept on storing in untreated state, then has a deterioration by the Prolonged storage and a risk of overflowing. Therefore, this research examined the fundamental characteristics of combustion and emission for the target of using the IPA (iso-propyl alcohol) solution as a part of PCBs control. IPA was filled to three kinds of Vessel, i.e. Vessel I, II, and III, and then was investigated as follows combustion shape, flame temperature. mass burning velocity, and PM(Particulate matter). A radial thermometer and a C-A thermocouple measured the flame temperature, and the optical extinction method by using He-Ne laser and the filter weight method used in the PM measurement. As a result, with an increasing of L/S ratio, the flame length become shorter and the burning velocity is more rapid, but the particulate matters is higher. It is supposed that the air flow rate is high on Vessel. and then the combustion is Promoted in the surface area of the upstream zone. The future works plan to investigate the characteristics with an using of the mixing of IPA and PCBs