• Title/Summary/Keyword: temperature management

Search Result 2,911, Processing Time 0.029 seconds

A Real Time Temperature Monitoring System for Plating Process (도금공정 실시간 원격 온도 모니터링 시스템)

  • Jung, Sun-Wung;Choi, Tae-Lin;Yoo, Woosik;Kim, Byung Soo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.4
    • /
    • pp.72-79
    • /
    • 2015
  • A number of plating companies have been exposed to the risk of fire due to unexpected temperature increasing of water in a plating bath. Since the companies are not able to forecast the unexpected temperature increasing of water and most of raw materials in the plating process have low ignition temperature, it is easy to be exposed to the risk of fire. Thus, the companies have to notice the changes immediately to prevent the risk of fire from plating process. Due to this reason, an agile and systematic temperature monitoring system is required for the plating companies. Unfortunately, in case of small size companies, it is hard to purchase a systematic solution and be offered consulting from one of the risk management consulting companies due to an expensive cost. In addition, most of the companies have insufficient research and development (R&D) experts to autonomously develop the risk management solution. In this article, we developed a real time remote temperature monitoring system which is easy to operate with a lower cost. The system is constructed by using Raspberry Pi single board computer and Android application to release an economic issue for the small sized plating manufacturing companies. The derived system is able to monitor the temperature continuously with tracking the temperature in the batch in a short time and transmit a push-alarm to a target-device located in a remoted area when the temperature exceeds a certain hazardous-temperature level. Therefore, the target small plating company achieves a risk management system with a small cost.

A Design of Temperature Management System for Preventing High Temperature Failures on Mobility Dedicated Storage (모빌리티 전용 저장장치의 고온 고장 방지를 위한 온도 관리 시스템 설계)

  • Hyun-Seob Lee
    • Journal of Internet of Things and Convergence
    • /
    • v.10 no.2
    • /
    • pp.125-130
    • /
    • 2024
  • With the rapid growth of mobility technology, the industrial sector is demanding storage devices that can reliably process data from various equipment and sensors in vehicles. NAND flash memory is being utilized as a storage device in mobility environments because it has the advantages of low power and fast data processing speed as well as strong external shock resistance. However, flash memory is characterized by data corruption due to long-term exposure to high temperatures. Therefore, a dedicated system for temperature management is required in mobility environments where high temperature exposure due to weather or external heat sources such as solar radiation is frequent. This paper designs a dedicated temperature management system for managing storage device temperature in a mobility environment. The designed temperature management system is a hybrid of traditional air cooling and water cooling technologies. The cooling method is designed to operate adaptively according to the temperature of the storage device, and it is designed not to operate when the temperature step is low to improve energy efficiency. Finally, experiments were conducted to analyze the temperature difference between each cooling method and different heat dissipation materials, proving that the temperature management policy is effective in maintaining performance.

Improvement of Low Temperature Fuel Characteristics by Pour Point Depressant (유동점 강하제에 의한 바이오디젤 저온특성 향상)

  • Lim, Young-Kwan;Lee, Joung-Min;Jeong, Choong-Sub;Kim, Jong-Ryeol;Yim, Eui-Soon
    • Tribology and Lubricants
    • /
    • v.27 no.2
    • /
    • pp.109-114
    • /
    • 2011
  • The low temperature characteristics of automotive diesel have been legally regulated due to the fact that solid particle in diesel at low temperature can cause severe problems in the vehicle. The biodiesel is well known for eco-friendly fuel, which is one of the most popular alternative petrodiesel, but it is easy to solidified at low temperature than petrodiesel at low temperature. For that reason, in this study, we investigated the low temperature fuel characteristics of diesel-biodiesel blends which were prepared to mix 6 different kinds of biodiesel to winter diesel fuel, respectively. Also, we confirmed to improve low temperature fuel characteristics by pour point depressant.

A Study on improvement of plating equipment for fire prevention (도금 공장의 화재 예방을 위한 도금장비 개선에 관한 연구)

  • Kim, Sung-Jae;Kim, Sung-Gon;Yoo, Woo-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.35-42
    • /
    • 2017
  • A number of plating companies have been exposed to the risk of fire due to unexpected temperature increasing of water or other reasons in a plating bath. Since the companies are not able to forecast the unexpected temperature increasing of plating bath and most of raw materials in the bath have low ignition temperature, it is easy to be exposed to the risk of fire. Thus, in previous study, we tried to monitor and notice the dangerous change of temperature of water immediately to prevent the risk of fire from plating process. However, unfortunately previous studies were not able to shut out the fundamental cause of fire since bath temperature sensor can detect air temperature when the level sensor was malfunctioned. In this paper we developed the Teflon heater which contains a built in temperature sensor and improved plating equipment system. Teflon heater is improved using Pt $100{\Omega}$ sensor which can detect until $600^{\circ}C$. When the bath temperature sensor detects over $60^{\circ}C$ or the Teflon heater sensor detects over $240^{\circ}C$ they temporarily shut down the heater to control temperature. Also relay completely shuts down main power when detects instant temperature is detected over 5% of $240^{\circ}C$ by the heater sensor to prevent teflon melting down and fire spreads. Developed plating equipment system can monitor a real time temperature in the teflon tube and bath water. Therefore we think the proposed plating equipment can eliminate the possibility of fire in plating processes fundamentally.

Numerical Analysis of Heat Transfer and Solidification in the Continuous Casting Process of Metallic Uranium Rod (금속 우라늄봉의 연속주조공정에 대한 열전달 및 응고해석)

  • Lee, Ju-Chan;Lee, Yoon-Sang;Oh, Seung-Chul;Shin, Young-Joon
    • Journal of Korea Foundry Society
    • /
    • v.20 no.2
    • /
    • pp.80-88
    • /
    • 2000
  • Continuous casting equipment was designed to cast the metallic uranium rods, and a thermal analysis was carried out to calculate the temperature and solidification profiles. Fluid flow and heat transfer analysis model including the effects of phase change was used to simulate the continuous casting process by finite volume method. In the design of continuous casting equipment, the casting speed, pouring temperature and cooling conditions should be considered as significant factors. In this study, the effects of casting speed, pouring temperature, and air gap between the uranium and mold were investigate. The results represented that the temperature and solidification profiles of continuous casting equipment varied with the casting speed, pouring temperature, and air gap.

  • PDF

Perceived Performance of Sanitary Management of School Food Service Managers in the Seoul Area (서울지역 초등학교 급식관리 영양사의 위생관리와 관련된 직무 수행도)

  • 정유경;곽동경
    • Korean Journal of Community Nutrition
    • /
    • v.5 no.1
    • /
    • pp.100-108
    • /
    • 2000
  • Seven constructs of sanitary management :time temperature, storage, cross-contamination, personal hygiene, equipment facility and documentation management were evaluated to investigate the perceived performance of sanitary management for school food service managers, Using a four-part questionnaire containing the seven constructs of sanitary management HACCP program, demographic information and characteristics of food service facilities participants rated their self-perceptions regarding sanitary management. Of the 550 possible respondents, 248(45.1%) completed the study. For the perceived sanitary manage-ment variables, the participants rated them between 2.66 and 4.16(5-point Likert scale). Temperature management presented the lowest performances while storage management showed the highest. The number of years of work experience of the food service managers and the serving location correlated significantly to sanitary management variables. Documentation management was also highly correlated to the other sanitary management constructs. The respondents ranked the managers leadership and professional knowledge regrading HACCP as most important, followed by the facilitys supporting equipment and human resources second, to successfully implement the HACCP system at the school food service facilites, Awareness of this study indicating low performance on temperature management suggests an active training program is needed for sanitary management of school food service.

  • PDF

A Prediction-Based Dynamic Thermal Management Technique for Multi-Core Systems (멀티코어시스템에서의 예측 기반 동적 온도 관리 기법)

  • Kim, Won-Jin;Chung, Ki-Seok
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.4 no.2
    • /
    • pp.55-62
    • /
    • 2009
  • The power consumption of a high-end microprocessor increases very rapidly. High power consumption will lead to a rapid increase in the chip temperature as well. If the temperature reaches beyond a certain level, chip operation becomes either slow or unreliable. Therefore various approaches for Dynamic Thermal Management (DTM) have been proposed. In this paper, we propose a learning based temperature prediction scheme for a multi-core system. In this approach, from repeatedly executing an application, we learn the thermal patterns of the chip, and we control the temperature in advance through DTM. When the predicted temperature may go beyond a threshold value, we reduce the temperature by decreasing the operation frequencies of the corresponding core. We implement our temperature prediction on an Intel's Quad-Core system which has integrated digital thermal sensors. A Dynamic Frequency System (DFS) technique is implemented to have four frequency steps on a Linux kernel. We carried out experiments using Phoronix Test Suite benchmarks for Linux. The peak temperature has been reduced by on average $5^{\circ}C{\sim}7^{\circ}C$. The overall average temperature reduced from $72^{\circ}C$ to $65^{\circ}C$.

  • PDF

Research and Development of RFIC Technology in Smart Temperature Information Material

  • Chang, Chih-Yuan;Hung, San-Shan;Chang, Yu-Chueh;Peng, Yu-Fang
    • Journal of Construction Engineering and Project Management
    • /
    • v.1 no.1
    • /
    • pp.18-23
    • /
    • 2011
  • Conservation of energy and fuel is the trend in smart building design. Radio Frequency Integrated Circuit (RFIC) technology is often used in temperature sensing and signal transmission to manage indoor temperature, but it is rarely applied to the shell of the building. Heat retention and poor insulation in building shells are the largest causes of high energy consumption by indoor air conditioning. Through combining RFIC technology with temperature sensors, this study will develop smart temperature information material that can be embedded in concrete. In addition to accurately evaluating the effectiveness of shell insulation material, the already-designed Building Physiology Information System can monitor long-term temperature changes, leading to smarter building health management.

A Study on the Cooling Performance Improvement of Pouch Battery Thermal Management System for Electric Vehicles (전기자동차 파우치형 배터리 열관리 시스템의 냉각성능 향상에 대한 연구)

  • Shin, Jeong-Hoon;Lee, Jun-Kyoung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.715-724
    • /
    • 2022
  • In many electric vehicles, large-capacity pouch-type lithium-ion battery packs are mainly used to increase the mileage on a single charge. The lithium ion battery should be operated within the temperature range of 25℃ to 40℃ because the battery performance can be rapidly deteriorated due to an increase in internal temperature. Battery thermal management system (BTMS) can give the suitable temperature conditions to battery by water cooling method. In this research, the heat transfer characteristics (the battery temperature distributions and the water flow characteristics) were analyzed by CFD method to investigate the thermal performance of the cooling plate with 4-pass water flow structure. Moreover, the effect of the presence of fins between the battery cell was identified. The fins made smooth temperature distributions between the battery cells due to the heat spreading and lower the average battery cells temperature.

RESEARCH AND DEVELOPMENT OF RFIC TECHNOLOGY IN SMART TEMPERATURE INFORMATION MATERIAL

  • Chih-Yuan Chang;San-Shan Hung;Yu-Chueh Chang;Yu-Fang Peng
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.480-486
    • /
    • 2011
  • Conservation of energy and fuel is the trend in smart building design. Radio Frequency Integrated Circuit (RFIC) technology is often used in temperature sensing and signal transmission to manage indoor temperature, but it is rarely applied to the shell of the building. Heat retention and poor insulation in building shells are the largest causes of high energy consumption by indoor air conditioning. Through combining RFIC technology with temperature sensors, this study will develop smart temperature information material that can be embedded in concrete. In addition to accurately evaluating the effectiveness of shell insulation material, the already-designed Building Physiology Information System can monitor long-term temperature changes, leading to smarter building health management.

  • PDF