• 제목/요약/키워드: temperature limit

검색결과 1,360건 처리시간 0.034초

Effect of Electroacupuncture Analgesia on Changes of Vital Signs and Blood Chemical Values in Cats

  • Shin, Dong-Hoon;Lee, Jae-Yeon;Kim, Duck-Hwan;Park, Chang-Sik;Jeong, Seong-Mok;Son, Dong-Soo;Kim, Myung-Cheol
    • 한국임상수의학회지
    • /
    • 제25권3호
    • /
    • pp.170-175
    • /
    • 2008
  • The present study was performed to investigate the anesthetic or analgesic effect of tiletamine-zolazepam (TZ) and electro acupuncture analgesia (EAA) in cats. Twelve healthy cats were randomly assigned to receive either TZ or EA. TZ group cats with weight of $3.65{\pm}0.48kg$ received 10.0 mg/kg of TZ intramuscularly. EA group cats with weight of $3.62{\pm}0.52kg$ received 5V, 30Hz and 60 minutes of EA. The acupoints used were Tian-ping (GV-5, +), Bai-hui (GV-20, -). Therefore, after and before experiment, some serum chemistry profiles (alkaline phospatase, aspartate aminotransferase, alanine aminotransferase, glucose and total protein) and change of vital signs (rectal temperature, heart rate, respiratory rate) were examined. All cats were examined pre, and 5, 25, 65 and 105 minutes after administration of TZ or operation of EA. The cats in EA group showed a smaller change in rectal temperature, heart rate and respiratory rate than in the TZ group (p<0.05). In both groups, total protein concentration was constant throughout the period of anesthesia, and the serum glucose increased gradually throughout the period of anesthesia. However, the cats in EA group showed a smaller change in alkaline phospatase, aspartate aminotransferase and alanine aminotransferase within the limit of safety than in the TZ group (p<0.05). While coming to induction, the TZ group took a mean $2.4{\pm}0.7$ minutes to achieve sternal recumbency, compared with $10.5{\pm}2.1$ minutes by the EA group, and $3.2{\pm}0.6$ minutes to achieve lateral recumbency, compared with $18.8{\pm}1.9$ minutes by the EA group (p<0.05). When recovering from anesthesia, the TZ group took $164.3{\pm}17.9$ minutes to achieve sternal position time, compared with $67.7{\pm}4.6$ minutes by the EA group, and $202.0{\pm}15.7$ minutes to stand, compared with $73.0{\pm}6.1$ minutes for the EA group (p<0.05). In this study, the cats anesthetized with EA showed a more rapid recovery rather than the cats under TZ anesthesia. Also, there do not appear to be any negative physiologic effects associated with acupuncture-induced surgical analgesia. So, it was considered that EAA may be used effectively in shock, debilitated cats, as compared to TZ.

ELSD를 이용한 레시틴중의 포스파티딜콜린의 분석 (Determination of Phosphatidylcholine in Korea Functional Foods Containing Lecithins using HPLC with Evaporative Light-Scattering Detector (ELSD))

  • 이창희;반경녀;조태용;이주연;이영자;채갑용
    • 한국식품위생안전성학회지
    • /
    • 제20권4호
    • /
    • pp.267-271
    • /
    • 2005
  • 본 연구는 세포막의 구성성분으로서 인체의 신진대사에 관여하는 물질인 인지질을 정량하기 위하여 인지질의 주요성분인 포스파티딜콜린에 대해 HPLC/ELSD를 이용한 신속, 정확한 분석법을 확립하였다. HPLC의 조건은 silica column을 사용하고 헥산:이소프로판올:물-30:60:8을 유속 0.5 ml/min으로 포스파티딜콜린을 분리하였고 ELSD 검출기를 사용하여 nebulizer온도는 $60^{\circ}C$. drift tube온도는 $75^{\circ}C$, carrier gas 30 psi로 하여 20 min내에 분리하였으며 검량선은 250 ppm$\∼$1,000 ppm으로 하여 정량하였다. 시료의 회수율은 $80\%$이상으로 높게 나타났으며 정량한계는 0.15 ppm이였다. 또한 이 분석법을 이용하여 실제 유통되고 있는 레시틴제품(난황레시틴 2종, 대두레시틴8종)에 대해 인지질의 함량과 포스파티딜함량을 조사한 결과, 인지질의 함량은 각각 81.5$\∼$83.3$\%$, $66.0\∼88.0\%$로 나타났으며 포스파티딜콜린의 함량은 각각 74.8$\∼$ 8.6$\%$$18.7\∼62.3\%$로 난황레시틴의 함량이 높게 나타났다.

공기중 유기용제 농도 측정에 있어서 수동식 시료채취기의 성능평가 및 한국산 수동식 시료채취기의 개발에 관한 연구 제 2 부 : 한국산 수동식 시료채취기의 개발 (Evaluation of Commercially Available Passive Samplers and Development of New Passive Samplers Part 2 : Development of New Passive Samplers)

  • 백남원;공상휘;박정임;이영환
    • 한국산업보건학회지
    • /
    • 제6권1호
    • /
    • pp.97-108
    • /
    • 1996
  • A new type of passive samplers were designed and produced by authors. After evaluating the quality of activated carbon by measuring recovery rate of organic vapors and steadiness of sampling rate, activated carbon with 30 - 35 mesh produced by Company S in Korea was selected. In each passive sampler, an amount of 400 mg of the activated carbon was filled in 25-mm cassette and covered by fixed screen (or wire screen with 100 mesh). In addition to the fixed screen, a wind screen (or wire screen with 300 mesh) was also attached at outer face. The sampling rate of the new Korean passive samplers was estimated Conclusions obtained in the study are as follows. 1. Sampling rates of the newly developed Korean passive samplers were affected by sampling time. For n-hexane, sampling rates of 15- and 60-minute samples were 70.92 and 37.45 ml/min, respectively. Sampling rate of both 200- and 450-minute samples was 25.96 ml/min. It is concluded that, when passive samplers are used for measuring organic vapors, samples be collected longer than 60 minutes. 2. Sampling rate of the passive samplers was also affected by airborne concentration of organic vapors. Lower sampling rates were determined at level of 1/2 threshold limit values (TLVs) recommended by the American Conference of Governmental Industrial Hygienists (ACGIH). It is recommended that sampling rate of the passive samplers be obtained at site by measuring concentrations using both the NIOSH Method and passive samplers simultaneously. 3. When the passive samplers, which collected organic vapors, were exposed to clean air for five hours, there was no significant loss of organic vapors due to reverse diffusion. 4. When samples were stored at room temperature ($21.8{\pm}0.7^{\circ}C$) and refrigerator ($3.8{\pm}0.7^{\circ}C$), there was no significant difference in the accuracy of results. For trichloroethylene and n-hexane, accuracies were within 25 % at both temperatures until seven days. However, poor accuracy exceeding 25 % was indicated in toluene from the first day. It is recommended that samples be stored at freezing temperature below $0^{\circ}C$. 5. Sampling efficiency was significantly affected by direction of the passive samplers. Results of samplers facing wind and down, respectively, were compared. Lower amount of organic vapors were collected when the sampler was oriented down. It is recommended that, when air velocity is low in plants, the passive samplers be oriented to the wind. However, when air velocity is high, the passive samplers be oriented down.

  • PDF

Hot environment on reproductive performance, immunoglobulins, vitamin E, and vitamin A status in sows and their progeny under commercial husbandry

  • Amavizca-Nazar, Alejandra;Montalvo-Corral, Maricela;Gonzalez-Rios, Humberto;Pinelli-Saavedra, Araceli
    • Journal of Animal Science and Technology
    • /
    • 제61권6호
    • /
    • pp.340-351
    • /
    • 2019
  • Hot environments can affect feed intake and lactation, and the subsequent unavailability of important micronutrients to the newborn piglet can impair piglet growth, reduce the viability of newborn piglets and limit their subsequent performance. This work addresses the effects of hot environments (summer season) upon the reproductive performance of sows during gestation and lactation as well as on the serum levels of vitamins and the concentration of immunoglobulins in their litters in comparison with the winter season. Fourteen sows were evaluated over 100 ± 2 days of gestation in each season. The temperature and humidity index (THI) was used as an indirect measure of heat stress during gestation. The reproductive performance, milk yield, and body condition of the sows were recorded. The concentrations of vitamin E and vitamin A in piglets and in sow serum, colostrum, milk and feed were determined by HPLC; immunoglobulins were assessed by an ELISA. The THI index indicated that animals were subject to heat stress only in during the summer. Although the effect was not significant, there were a lower number of piglets at birth and at weaning and the milk yield in summer compared with winter. There was no difference (p > 0.05) in the body condition of sows between seasons. Season had an effect (p < 0.05) on the vitamin A concentration of postpartum sow serum (0.29 ㎍/mL in winter vs 0.21 ㎍/mL in summer) and on the vitamin E concentration before birth (2.00 ㎍/mL in winter vs 0.90 ㎍/mL in summer). Vitamin E in milk was higher (p < 0.05) in winter than in summer (2.23 vs 1.81 ㎍/mL). Serum levels of vitamins A and E in piglets at birth were lower (p < 0.05) in winter than in summer. The concentrations of immunoglobulins (IgG and IgA) in colostrum and milk were similar between seasons (p > 0.05), but the IgA in piglet serum was higher in winter than in summer (p < 0.05). High temperatures produced heat stress in sows, which affected certain aspects of production that can be translated into economic losses for this sector.

유도 가열 접합 시스템을 이용한 대용량 이차전지 전극의 접합 방법 및 특성 (Electrode bonding method and characteristic of high density rechargeable battery using induction heating system)

  • 김은민;김신효;홍원희;조대권
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권6호
    • /
    • pp.688-697
    • /
    • 2014
  • 본 연구에서는 최근, 전기자동차 및 소형 레저용 선박을 중심으로 연구가 진행 중인, 대용량 이차전지의 용량 증대를 위하여 필요한 내부 전극 접합 기술에 관하여 연구하였다. 종래의 초음파 용접으로 적층할 수 있는 적층 량의 한계를 극복하기 위한 방안으로 전극 소재에 직접 가열을 통한 용접 방법이 아닌 용가재 금속을 적용하여 전극을 접합시켜, 통전성과 인장강도를 증대시킴과 동시에 열적요인으로 인한 전극표면에 화학적 활성물질의 변성을 최소화 할 수 있는 저온 접합 방법에 대하여 연구하였다. 부연하여 현재 일반적으로 적용되고 있는 초음파 용접 및 저항 용접은 전극을 다량 적층 접합 시켰을 경우 일정한 전기 전도성과 접합 강도를 구현하기 힘들다. 용접을 위하여 무리하게 출력을 상승시킬 경우 용접열의 영향으로 전극의 변형 및 활성물질의 변성을 야기함과 동시에 최종 페키징(packaging) 이후 출력저하, 발열 등, 배터리의 안정성을 저하시키는 요인으로 작용한다. 따라서 본 연구에서는 고주파 유도가열을 통한 유도 가열 방식의 접합 방법과 용융 도금을 통한 용가재 금속의 전처리를 통한 종래와는 차별화된 전극접합 방법을 소개한다.

서울 경기지역의 공원 연못 및 한강 수계내 조류독소 Microcystin-LR의 분포 (Distribution of Cyanotoxin Microcystin-LR in Han River System and Ecological Park in Seoul and Kyunggi Districts)

  • 서미연;김백호;한명수
    • 생태와환경
    • /
    • 제38권2호통권112호
    • /
    • pp.237-248
    • /
    • 2005
  • 서울 경기지역 공원 연못 및 한강 수계내의 수중 조류독소 Microcystin (MC)의 분포를 파악하기 위하여, 수도권 공원 연못 7개소, 한강수계 4개소, 경안천 1개소, 양수리 육각지 1개소, 대조군 2개소를 포함 총 15개 지점을 대상으로 강우가 적은 저온기 동안, 3차례에 걸쳐 수중내 환경요인, 조류 현존량, 조류 독소량을 조사하였다. 조류독소는 유도체중 가장 독성이 강한 Microcystin-LR (MCLR)만을 대상으로 하였으며 ELISA법으로 분석하였다. 조사기간 동안 수온($0.4\;{\sim}\;21.9^{\circ}C$)을 비롯한 대부분의 환경요인들은 계절성과 지역성이 뚜렷하였다. 조류 현존량은 수온 변화에 민감하였고 (r = 0.307), Microcystis aeruginosa를 포함하여 남조류는 경복궁 경회루, 석촌호수. 양수리 육각지 등에서 우점하였다. 조류독소 MCLR (측정한계 $0.05\;{\mu}g\;L^{-1}$) 는 남조 Microcystis aeruginosa출현이 높았던 지점에서 높게 검출되었으며, 조체성과 용존성을 합한 총 MCLR은 1차조사시 경복궁 경회루 ($1.39\;{\mu}g\;L^{-1}$), 석촌호수($0.55\;{\mu}g\;L^{-1}$), 양수리 육각지 ($0.59\;{\mu}g\;L^{-1}$)에서 각각 높게 나타났으나,2, 3차 조사에서는 양수리 육각지에서만 검출되었다. 남조류 총현존량은 조류 현존량 (r = 0.066)이나 엽록소 a량(r = -0.058)과는 낮은 관계를보였으며, M. aeruginosa 현존량(r = 0.766)과는 매우 높은 관계를 나타냈다. 조류독소 MCLR은 남조 M. aeruginosa 현존량이 높았던 지점에서 높게 검출되었다(조체성: r = 0.526, 용존성: r = 0.433).따라서, 서울, 경기지역 공원 연못이나 한강수계의 조류독소는 주로 정체성 연못에서 남조 Microcystis aeruginosa에 의해 형성되지만, 여가활동이나 상수원 공급에는 위험성이 낮은 것으로 판단되었다.

다세대주택의 화재안전평가에 대한 수치해석 연구 -계단실 개구부의 개폐가 화재특성에 미치는 영향- (A Numerical Study for Fire Safety Evaluation of the Multi-story Residential Buildings -The Effects of the Openings of Stairwell on Fire Characteristics-)

  • 전흥균;최영상;추홍록
    • 한국화재소방학회논문지
    • /
    • 제21권3호
    • /
    • pp.15-23
    • /
    • 2007
  • 일반주택 화재시 가연성이 높은 폴리우레탄폼 소재의 소파가 연소될 때 다량의 독성가스가 포함된 연기가 발생한다. 이 경우 실내거주자는 고온의 연기와 독성가스로 인해 피난의 어려움을 겪고, 극단적인 경우 사망에 이르게 된다. 본 연구에서는 다세대주택 화재시 계단실 개구부의 개폐조건이 화재실과 계단실의 화재특성에 미치는 영향을 조사하기 위하여 CFD 시뮬레이션을 수행하였다. 화재실험에서 얻어진 유동장의 온도, 일산화탄소 농도 및 연기가시거리의 자료를 분석하여 화재안전한계 기준값과 부분유효량에 근거한 화재위험평가를 하였다. 화재실의 경우, 온도와 일산화탄소 농도는 각각 최대 $290^{\circ}C$와 4,740 ppm이며, 온도에 의한 거주자의 불능상태 도달시간은 발화 후 약 144초이다. 계단실의 경우, 창문이 개방된 경우의 온도와 일산화탄소 농도는 화재안전한계 기준 값 이하로서 개방되지 알은 경우 보다 크게 감소되었다. 또 계단실의 연기가시거리는 개방된 경우가 개방되지 않은 경우보다 화재안전한계 기준 값에 더 빨리 도달되었다. 결론적으로 다세대주택 계단실의 개구부를 개방할 경우 거주자의 화재위험 가능성은 낮아진다.

$TiO_2$로 전처리한 아크릴 폐수의 Membrane Hybrid System에의 적용 (Application in Membrane Hybrid System with Acrylic Wastewater Pretreated by $TiO_2$)

  • 이광현;강병철;이종백;이강춘
    • 멤브레인
    • /
    • 제19권3호
    • /
    • pp.183-188
    • /
    • 2009
  • 아크릴폐수를 광촉매로 전처리하여 막오염인자를 최소화 한 후 막조합공정에 적용하였다. 한외여과막과 정밀여과막을 역삼투막과 조합을 이루어 막조합공정을 구성하였으며 광촉매처리수를 온도 및 압력변화에 따라 막조합공정에 적용하여 분리특성을 확인하였다. 정밀여과막 모듈 혹은 한외여과막 모듈의 투과수는 역삼투모듈로 보내지며 역삼투 모듈의 최종적인 투과량은 모듈 set 2 (MWCO 200,000 UF+RO)의 역삼투 모듈이 우수하였다. UF 및 MF 모듈에서 TDS, T-N 및 COD의 제거효율은 온도 및 압력변화에 영향을 받지 않고 제거효율 또한 낮음을 알 수 있었다. 그러한 결과로 RO 모듈에서 TDS, T-N 및 COD가 우수한 제거효율을 보였다. UF 및 MF모듈에서의 탁도 제거효율은 우수한 경향(제거효율 99% 이상)을 보였다. 막조합공정에서 처리된 광촉매처리수는 배출 허용기준치를 충족하고, 재활용이 가능하였다.

전기동력학 기술을 이용한 시설재배지 토양 염류제거 실증 연구 (A Field Study on Electrokinetic Removal of Salts from Greenhouse Soil)

  • 이유진;최정희;심성주;하태현;이현구
    • Korean Chemical Engineering Research
    • /
    • 제52권1호
    • /
    • pp.126-132
    • /
    • 2014
  • 본 연구에서는 높은 농도의 염류가 집적된 시설재배지 토양의 제염을 위해 전기동력학적(EK) 기술을 적용한 파일럿 규모($2{\times}3{\times}0.2m^3$, $W{\times}L{\times}D$)의 실증시험을 실시하였다. 실험 전 토양의 전기전도도(EC)는 약 9 dS/m였으며, 토양내 주요 염류는 $Ca^{2+}$, $Cl^-$, $SO_4^{2-}$ 이온이었다. 2주간의 EK 처리 후 토양의 EC는 실험 전에 비해서 52% 감소하였으며, 이 중 대부분은 초기 1주일 이내에 제거되었다(47%). 이는 주로 $Na^+$$Cl^-$의 제거에 의한 것으로 보이며, 주요 염류 이자 토양에 대해 높은 흡착능을 가지는 $Ca^{2+}$$SO_4^{2-}$이온은 상대적으로 제거율이 낮았다. EK 실험이 진행되는 동안 토양의 온도는 전류의 세기에 따라 증가하여 최대 $50^{\circ}C$까지 증가하였다. 따라서 작물이 재배 중인 토양의 원위치 EK 적용을 위해서는 토양의 온도 상승을 제한하기 위해 전류를 조절할 필요가 있다. 결론적으로 EK 기술을 이용하여 경작 중이거나 휴경 중인 시설재배지 토양의 원위치 염류 제거가 가능할 것으로 판단되며 효율적인 탈염을 위해서는 적절한 운전 전략이 요구된다.

수도용 강관의 온도변화에 따른 물리적 특성에 대한 연구 (Study on the Physical Characteristics of Water Supply Steel Pipe according to Temperature Change)

  • 김우영;장암
    • 대한환경공학회지
    • /
    • 제39권12호
    • /
    • pp.733-740
    • /
    • 2017
  • 환경부에서 수립한 "상수도 시설기준(2004)"은 관로 신축이음관 설치기준에 있어서는 용접이음 강관에는 설치하지 않는 것으로 규정하고 있으며, 이에 대한 근거가 명확하지 않고 관로 안정성이 충분히 확보되었는지 확인하기가 어렵다. 금번 연구에서는 강관의 거동 분석을 통한 관로 안정성을 연구하여 신축이음관의 필요여부를 검증하는 것을 목적으로 하였다. 검토결과는 아래와 같다. 첫째, 아스팔트 도복장강관(D2,400 mm)은 온도변화에 따라 4-cycle로 관로 신 수축이 반복되며, 연장 1.24 km에 있어 최대 13.03 mm의 변위를 나타내었다. 둘째, 수도용 강관의 신 수축으로 발생되는 온도응력은 매설깊이(최대 4 m)에 따라 $13.7{\sim}36.1kgf/cm^2$로 발생되며, 강관(STWW 400)의 안정성에 큰 영향을 키치는 주요 비교인자인 허용 인장강도와 피로한도는 $4,100kgf/cm^2$$1,840kgf/cm^2$로 산출되었다. 마지막으로, 수도용 강관의 온도응력은 허용 인장강도와 피로한도와 비교시 매우 작음에 따라, 온도변화에 의한 관로의 신 수축이 발생하여도 관로 안정성에는 영향을 끼치지 못함을 알 수 있었다. 결론적으로 금번 연구를 통하여 수도용 강관의 관로부에는 신축이음관을 설치할 필요가 없는 것으로 증명되었다.