• Title/Summary/Keyword: temperature limit

Search Result 1,360, Processing Time 0.035 seconds

Effect of post heat treatment on fatigue properties of EBM 3D-printed Ti-6Al-4V alloy (분말 3D 프린팅된 Ti-6Al-4V 합금의 피로특성에 미치는 후열처리의 영향)

  • Choi, Young-Sin;Jang, Ji-Hoon;Kim, Gun-Hee;Lee, Chang-Woo;Kim, Hwi-Jun;Lee, Dong-Geun
    • Journal of Powder Materials
    • /
    • v.25 no.4
    • /
    • pp.340-345
    • /
    • 2018
  • Additive manufacturing by electron beam melting is an affordable process for fabricating near net shaped parts of titanium and its alloys. 3D additive-manufactured parts have various kinds of voids, lack of fusion, etc., and they may affect crack initiation and propagation. Post process is necessary to eliminate or minimize these defects. Hot isostatic pressing (HIP) is the main method, which is expensive. The objective of this paper is to achieve an optimum and simple post heat treatment process without the HIP process. Various post heat treatments are conducted for the 3D-printed Ti-6Al-4V specimen below and above the beta transus temperature ($996^{\circ}C$). The as-fabricated EBM Ti-6Al-4V alloy has an ${\alpha}^{\prime}$-martensite structure and transforms into the ${\alpha}+{\beta}$ duplex phase during the post heat treatment. The fatigue strength of the as-fabricated specimen is 400 MPa. The post heat treatment at $1000^{\circ}C/30min/AC$ increases the fatigue strength to 420 MPa. By post heat treatment, the interior pore size and the pore volume fraction are reduced and this can increase the fatigue limit.

STUDIES ON THE WATER QUALITY OF NAGDONGG RIVER DOWNSTREAM FOR DRINKING WATER AND INDUSTRIAL SUPPLY WATER 1. SEASONAL VARIATIONS OF THE CONTENTS OF INORGANIC CONSERVATIVE CONSTITUENTS OF ANGDONG RIVER DOWNSTREAM WATER FROM MAY 1977 APRIL 1978 (음료수 및 공업용수로서의 낙동강 하류수질에 대하여 1. 남지이남 낙동강 하류수의 무기보존성분량의 년간변동에 대하여(1977년 5월~1978년 4월))

  • WON Jong Hun;YANG Han Serb
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.11 no.3
    • /
    • pp.129-138
    • /
    • 1978
  • The contents of inorganic conservative constituents in the downstream water were determined in spring tides of every month from May 1977 to April 1978 at eight stations of Nagdong River. Samples were taken at the intervals of one or two hours from 7 a. m. to 7 p. m. at each station. Annual ranges and means of the chemical constituents over all the stations except station one, Kupo, ate as follows: pH 6.4-9.3, 7.7; electrical conductivity $0.085-0.345\times10^3\;\mu\mho/cm,\;0.196\times10^3\;\mu\mho/cm;$ chloride 5.8-50.0ppm, 17.7ppm: fluoride ND-0.19 ppm, 0.06 ppm: sulfate 5.5-41.1 ppm, 20.7 ppm; calcium 6-26 ppm, 17 ppm; magnesium 2.0-12.8 ppm, 5.1 ppm; sodium 7-26 ppm, 13 ppm; potassium 1.4-3.8 pprn, 2.3 ppm respectively. The seasonal variations of contents of the chemical constituents were not large and showed nearly definite values at all the stations except station one, Kupo. At station one, seasonal variations were large and the contents were excessively high due to inflow of seawater compared with other stations. The values over 50 ppm in chloride were not determined during the determination period at Mul Geum where the intake station for Busan city water is located. Most constituents except pH and fluoride were over the criteria for drinking water at Kupo, while at other stations only pH value was exceeded the upper limit of the criterion especially in summer period. The pH values tended to increase in the afternoon when water temperature was high. The chloride concentration was shown the highest value at station one, Kupo, with about 2 hours delay after high water of Busan harbour and 3-3.5 hours at Mul Geum.

  • PDF

Photometric Determination of Chlorite ion by Flow Injection Analysis (흐름주입 분석에 의한 아염소산 이온의 분광광도법 정량)

  • Choi, Yong Wook;Lee, Su Young;Kim, Mi Kyung;Park, Sung Ho
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.6
    • /
    • pp.556-562
    • /
    • 2000
  • The determination of chlorite ion by flow injection analysis(FIA) with iodometric UV detection were investigated. Under rather acidic condition, chlorite ion react with iodide ion to form iodine and itself is reduced to chloride ion. The chlorite ion was determined indirectly by measuring absorbance of yellow colored iodine at 370 nm. The lengths of the mixing coil and the reaction coil, the pH of the acid stream, the concentration of the iodide ion, the injection loop volume, temperature, and flowrate were optimized as parameters for selectively determining a sort of inorganic disinfection by-product, chlorite ion by using FIA-UV detection setup. Masking agents for removing oxidants or interferences from the prepared water were tested. Independent calibration curve presented linear range of 0.002-0.2 mg/L for chlorite ion with a correlation coefficient of 0.999 or better. The limit of detection(LOD) was 0.18 ${\mu}g/L$ for chlorite ion.

  • PDF

Novel Silver(I) Ion Selective PVC Membrane Electrode Based on the Schiff Base (N2E,N2'E)-N2,N2'-Bis(Thiophen-2-ylmethylene)-1,1'-Binaphthyl-2,2'-Diamine

  • Jeong, Eunseon;Ahmed, Mohammad Shamsuddin;Jeong, Hae-Sang;Lee, Eun-Hee;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.800-804
    • /
    • 2011
  • A potentiometric sensor based on the Schiff base $(N^2E,N^{2'}E)-N^2,N^{2'}$-bis(thiophen-2-ylmethylene)-1,1'-binaphthl-2,2'-diamine has been synthesized and explored as an ionophore PVC-based membrane sensor selective for the silver ($Ag^+$) ion. Potentiometric investigations indicate a high affinity of this receptor for the silver ion. Seven membranes have been fabricated with different compositions, with the best performance shown by the membrane with an ionophore composition (w/w) of: 1.0 mg, PVC: 33.0 mg, DOA: 66.0 mg in 1.0 mL THF. The sensor worked well within a wide concentration range of $1.0{\times}10^{-2}$ to $1.0{\times}10^{-7}$ M, at pH 5, at room temperature (slope 57.4 mV/dec.), and with a rapid response time of 9 s; the sensor also showed good selectivity towards the silver ion over a huge number of interfering cations, with the highest selectivity coefficient for $Hg^{2+}$ at -3.7. Thus far, the best lower detection limit was $4.0{\times}10^{-8}$ M.

The Study on Measurement and Prediction of Combustible Properties for Aniline (아닐린의 연소특성치의 측정 및 예측에 관한 연구)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.44-50
    • /
    • 2014
  • For the safe handling of aniline, this study was investigated the explosion limits of aniline in the reference data. And the lower flash points, upper flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower flash point of aniline by using Setaflash and Penski-Martens closed-cup testers were experimented $66^{\circ}C$ and $73^{\circ}C$, respectively. The lower flash point aniline by using Tag and Cleveland open cup testers were experimented $72^{\circ}C$ and $78^{\circ}C$, respectively. Also, this study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for aniline. The experimental AIT of aniline was $590^{\circ}C$. The calculated LEL and UEL by using the measured low flash point and upper flash point were 1.16 Vol.% and 8.36 Vol.%, respectively.

A Study on the Characteristics and Utilization of Ash from Sewage Sludge Incinerator (하수(下水)슬러지 소각재의 특성(特性) 평가(評價) 및 재활용(再活用)을 위한 기초연구(基礎硏究))

  • Lee, Hwa-Young
    • Resources Recycling
    • /
    • v.17 no.3
    • /
    • pp.3-9
    • /
    • 2008
  • The measurement of physicochemical properties and chemical composition of SSA(sewage sludge ash) has been carried out and the preparation of lightweight material has also been performed using SSA for reuse as building or construction materials. For this aim, lightweight material has been prepared by forming the mixture of SSA, lightweight filler and inorganic binder followed by calcination at elevated temperature and characterized in terms of density and compressive strength. The pH of fly ash was found to be slightly alkaline, pH 8.69, due to the addition of caustic soda in order to neutralize the acidic gas while the pH of bottom ash was 6.48 Heavy metal leachability based on the standard leach test was also found to be below the detection limit for Cd, Cu, Pb, As and Cr of SSA. As far as the compressive strength of lightweight material was concerned, the compressive strength of lightweight material using fly ash was higher than that of lightweight material using bottom ash.

Combustion Characteristics of Premixed Burner for Fuel Reformer (개질기용 예혼합 연소장치의 연소특성 연구)

  • Lee, Pil-Hyong;Lee, Jae-Young;Han, Sang-Seok;Park, Chang-Soo;Hwang, Sang-Soon
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2181-2185
    • /
    • 2008
  • Fuel processing systems which convert HC fuel into $H_2$ rich gas (such as stream reforming, partial oxidation, auto-thermal reforming) need high temperature environment($600-1000^{\circ}C$). Generally, anode-off gas or mixture of anode-off gas and LNG is used as input gas of fuel reformer. In order to make efficient and low emission burner system for fuel reformer, it is necessary to elucidate the combustion and emission characteristic of fuel reformer burner. The purpose of this study is to develop a porous premixed flat ceramic burner that can be used for 1-5kW fuel cell reformer. Ceramic burner experiments using natural gas, hydrogen gas, anode off gas were carried out respectively to investigate the flame characteristics by heating capacity and equivalence ratio. Results show that the stable flat flames can be established for natural gas, hydrogen gas, anode off gas and mixture of natural & anode off gas as reformer fuel. For all of fuels, their burning velocities become smaller as the equivalence ratio goes to the lean mixture ratio, and a lift-off occurs at lean limit. Flame length in hydrogen and anode off gas became longer with increasing the heat capacity.

  • PDF

Doubled Thrust by Boundary Layer Control in Scramjet Engines in Mach 4 and 6

  • Mitani, Tohru;Sakuranaka, Noboru;Tomioka, Sadatake;Kobayashi, Kan;Kanda, Takeshi
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.734-741
    • /
    • 2004
  • Boundary layer ingestion in airframe-integrated scramjet engines causes engine stall (“engine un start” hereafter) and restricts engine performance. To improve the unstart characteristics in engines, boundary layer bleed and a two-staged injection of fuel were examined in Mach 4 and Mach 6 engine tests. A boundary layer bleed system consisting of a porous plate, an air coolers, a metering orifice and an ON/OFF valve, was designed for each of the engines. First, a method to determine bleed rate requirements was developed. Porous plates were designed to suck air out of the Mach 4 engine at a rate of 200 g/s and out of the Mach 6 engine at a rate of 30 g/s. Air coolers were then optimized based on the bleed airflow rates. The exhaust air temperature could be cooled below 600 K in the porous plates and the compact air coolers. The Mach 4 engine tests showed that a small bleed rate of 3% doubled the engine operating range and thrust. With the assistance of two-staged fuel injection of H2, the engine operating range was extended to Ф0.95 and the maximum thrust was tripled to 2560 N. The Mach 6 tests showed that a bleed of 30 g/s (0.6% of captured air in the engine) extended the start limit from Ф0.48 to Ф1 to deliver a maximum thrust of 2460 N.

  • PDF

Arsenic removal from drinking water by direct contact membrane distillation

  • Zoungrana, Ali;Zengin, Ismail H.;Elcik, Harun;Yesilirmak, Dilara;Karadag, Dogan;Cakmakci, Mehmet
    • Membrane and Water Treatment
    • /
    • v.7 no.3
    • /
    • pp.241-255
    • /
    • 2016
  • In this study, the treatability of arsenic (As) contaminated water by direct contact membrane distillation (DCMD) at different delta temperatures (${\Delta}T$) 30, 40 and $50^{\circ}C$ has been investigated. Two different pore sizes ($0.22{\mu}m$ and $0.45{\mu}m$) of hydrophobic membranes made of polyvinylidene fluoride (PVDF) were used. The membrane pore sizes, the operating temperatures, the feed solution As concentration and conductivity have been varied during the experimental tests to follow the removal efficiency and flux behavior. Both membranes tested had high removal efficiency of arsenite (As (III)) and arsenate (As (V)) and all permeates presented As concentration far lower than recommended $10{\mu}g/L$ of world health organization (WHO). As concentration was below detection limit in many permeates. Conductivity reduction efficiency was over 99% and the transmembrane flux (TMF) reached $19L/m^2.h$ at delta temperature (${\Delta}T$) of $50^{\circ}C$ with PVDF $0.45{\mu}m$ membrane. The experimental results also indicated that $0.45{\mu}m$ pore sizes PVDF membranes presented higher flux than $0.22{\mu}m$ pore sizes membranes. Regardless of all operating conditions, highest fluxes were observed at highest ${\Delta}T$ ($50^{\circ}C$).

A Simulation for the Stratified Thermal Storage System in Residential Solar Energy Application (주거용 태양열 성층축열시스템의 시뮬레이션)

  • Pak, Ee-Tong;Yoo, Ho-Seon
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.44-52
    • /
    • 1991
  • The benefits of thermal stratification in sensible heat storage systems has been considered and studying by several investigators. In this paper, the basic data which is hard to obtain normally through the experiment were obtainable through the computer simulation. The major objectives of the study were to assess the benefits of stratified storage in residential solar water heating application and to suggest the optimum design parameters. From the computer simulation, following results were obtained. 1. The solar load fraction increases with increasing the number of tank segments. In these simulation, the magnitude of the improvement was about 10%. 2. The solar load fraction increases when the ratio of diameter to height of the tank(H/D) increases to 3, but H/D exceed 3 then, the solar load fraction decreases. In these simulation, the magnitude of the improvement was about 3%. 3. Increasing the collector flow rate slightly improved the performance of the mixed storage system(Node=1). But, for the stratified storage system(Node=N), the solar load fraction increases with decreasing flow rate until the point is reached at which the collector outlet temperature reaches the boiloff limit of $100^{\circ}C$ over some portion of the simulation period.

  • PDF