• 제목/요약/키워드: temperature history

검색결과 681건 처리시간 0.022초

-10℃ 조건에서의 보온양생방법 변화에 따른 벽체 콘크리트의 온도이력 (Temperature History of the Wall Concrete Subjected to -10℃ depending on Heat Curing Method)

  • 한상윤;손호정;정상현;안상구;한천구;한민철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.255-256
    • /
    • 2011
  • This study investigates the effect of a curing condition on the temperature history and strength development of concrete under -10℃. Combination of various curing methods was applied, i.e. a conventional form was combined with compressed insulation, heat panel and heat cable. Results showed that the concrete cured by a single use of a conventional form resulted in serious deterioration of early strength development. However, other concretes cured by the proposed curing methods maintained the temperature of the concretes between 5 and 20℃, and thus resulted in no frost damage.

  • PDF

동절기 2중버블시트로 단열처리된 옹벽의 온도이력 특성 (Temperature History of the Concrete for Retaining Wall Insulated with Double Layered Bubble Sheet in Winter)

  • 정은봉;손호정;장덕배;경영혁;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.269-270
    • /
    • 2012
  • This study discussed the applicability of double layered bubble sheet(BS) to the concrete for retaining wall to verify the insulation effect as well as prevention of condensation. The BS was applied to the surface of retaining wall, which is contacted with ground. Temperature profile was monitored since placement of concrete. As expected, the application of BS helps the concrete keeping favorable heat insulating, preventing condensation.

  • PDF

표면 양생시트 조합에 의한 서중콘크리트 표면온도 이력 비교 (Comparison of Temperature History of Concrete with the Combination of the Various Surface Curing Sheets at Hot Weather Condition)

  • 이주석;김종백;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.87-90
    • /
    • 2006
  • This study investigates the temperature history of slab mock-up specimens for hot weather concreting applying various surface insulating methods, in order to improve concrete quality at hot weather condition. Test showed that the use of insulating blanket or a bubble sheet on upper section of slab prevented from abrupt increase of temperature and vaporization of moisture during early curing at hot weather circumstance. In addition, it secured higher strength at early age. Therefore it is concluded that concrete construction insulating with the bubble sheet will reduce the plastic and drying shrinkage as well as improve strength at early age, thus securing concrete duality.

  • PDF

밀폐튜브 내 저온 PCM의 잠열측정법 (Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube)

  • 류경용;박창현;백종현;홍회기
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.604-610
    • /
    • 2003
  • Cycle test for developed phase change material (PCM) is necessary in order to analyze the variation of latent heat, which decreases with time by deterioration. 7-history method and measurement using heat flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring the heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different from the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtain reason-able values for heat of fusion by both methods.

서중환경에서 표면피복 양생재 종류가 콘크리트의 온도에 미치는 영향 (Effect of the Kind of Surface-Covered Curing Materials on the Temperature of Concrete in Hot Weather)

  • 이제현;김민상;문병룡;이상운;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.173-174
    • /
    • 2017
  • Although the application period of hot weather concrete in our country is two months of July~August which is relatively short, many problems in various aspects such as generation of plastic/dry contraction cracks and cold joints can be caused unless proper quality control measures are established at this time. Therefore, this study compared the temperature history of the placed concrete by applying a mono white and aluminum-deposited bubble sheet developed with surface coating curing materials for surface exposure and summer to an actually constructed apartment slab. The analysis result showed that the mono white bubble sheet is the best method.

  • PDF

열선백금저항선을 이용한 과도적 전파화염의 화염온도측정에 관한 연구 (A Study on the Flame Temperature Measurement of the Transiently Propagating Flame by using Platinum-Hot-Wire-Resistance-Thermometry)

  • 정인석;조경국;황상순
    • 오토저널
    • /
    • 제7권3호
    • /
    • pp.94-101
    • /
    • 1985
  • The flame temperature of LPG-air premixture flame was measured by extrapolation of limiting case corresponding to the infinitely thin diameter of Platinum-resistance-hot-wire. LPG-air premixture flame, initially under atmospheric pressure and room temperature, propagates downward from top of the model combustion chamber maintained at constant pressure through the whole combustion process. Analytical calculation technique was also applied to determine full temperature history or spatial temperature distribution from flame reaction zone to burnt gas region.

  • PDF

전기발열시트 표면가열 양생공법의 현장적용 연구 (An Experimental Study on the Application in-situ of Curing Method by Planar Surface Heater for Cold Weather Concreting)

  • 김형래;조호규;김찬수;지남용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.19-22
    • /
    • 2003
  • The purpose of this study is to analyze the curing effect of planar surface heater for concreting in cold weather. Some experiments were conducted to evaluate the temperature history of concrete structures cured with heating sheets. Results are as follows ; (1) The temperature of concrete showed continuously rising trend with the heating by planar surface heater under the cold environmental condition of 3~-12$^{\circ}C$. And after about 24 hours the maximum temperature of concrete was reached at 25~3$0^{\circ}C$. (2) The temperature of slab concrete heated by planar surface heater of 130W/$m^2$ was at least $25^{\circ}C$ higher than that of an exterior air, and the curing performance was much more effective than heating by hot wind machine. (3) Through the curing by planar surface heater for 48 hours, the concrete maturity of about 1.5 times to heating by hot wind machine was acquired.

  • PDF

보일러 고온요소의 수명 감시시스템 소프트웨어 개발 (Development of On-line Life Monitoring System Software for High-temperature Components of Power Boilers)

  • 윤필기;정동관;윤기봉
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 춘계 학술발표회 논문집
    • /
    • pp.171-176
    • /
    • 1999
  • Nondestructive inspection and accompanying life analysis based on fracture mechanics were the major conventional methods for evaluating remaining life of critical high temperature components in power plants. By using these conventional methods, it has been difficult to perform in-service inspection for life prediction. Also, quantitative damage evaluation due to unexpected abrupt changes in operating temperature was almost impossible. Thus, many efforts have been made for evaluating remaining life during operation of the plants and predicting real-time life usage values based on the shape of structures, operating history, and material properties. In this study, a core software for on-line life monitoring system which carries out real-time life evaluation of a critical component in power boiler(high temperature steam headers) is developed. The software is capable of evaluating creep and fatigue life usage from the real-time stress data calculated by using temperature/stress transfer Green functions derived for the specific headers and by counting transient cycles. The major benefits of the developed software lie in determining future operating schedule, inspection interval, and replacement plan by monitoring real-time life usage based on prior operating history.

  • PDF

T-history 방법에 의한 잠열재의 열물성치 측정에 대한 실험적 연구 (An Experimental Study about the Measurement of the Thermal Properties of Phase Change Materials using T-history method)

  • 강동훈;백종현;박승상;서태범
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.226-231
    • /
    • 2001
  • The purpose of this paper is to propose the experimental method of thermal properties of Phase Change Materials (PCMs) by using T-history method. As far, in order to measure the heat of fusion and specific heat of PCMs, conventional thermal analysis methods such as DSC and DTA have been used. Because these methods test very small samples, thermal properties of samples are usually different from those of materials consisting of several components. For these reasons, T-history method, the simple measurement method of the heat of fusion and specific heat of PCMs have been performed. In this paper, we investigated the thermal properties of low temperature PCMs(below $0^{\circ}C$) under the charging process by using T-history method. The results are compared to those of DSC method. The T-history method will be useful for selection of the best PCM from lots of candidates and development of new PCMs.

  • PDF