• Title/Summary/Keyword: temperature correction

Search Result 483, Processing Time 0.025 seconds

Consideration of Temperature and Slip Correction for Photothermal Spectrometry

  • Lee, Jeonghoon
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.1
    • /
    • pp.86-90
    • /
    • 2015
  • Temperature was considered to estimate the minimum detectable absorption coefficient of aerosol particles from photothermal spectroscopy. Light energy absorbed by subsequent emission from the aerosol results in the heating of the aerosol sample and consequently causes a temperature change as well as changes in thermodynamic parameters of the sample. This thermal effect is the basis of photothermal spectroscopy. Photothermal spectroscopy has several types of techniques depending on how the photothermal effects are detected. Photothermal interferometry traces the photothermal effect, refractive index, using an interferometer. Photoacoustic spectroscopy detects the photothermal effect, sound wave, using a microphone. In this study, it is suggested that the detection limit for photothermal spectroscopy can be influenced by the introduction of a slip correction factor when the light absorption is determined in a high temperature environment. The minimum detectable absorption coefficient depends on the density, the specific heat and the temperature, which are thermodynamic properties. Without considering the slip correction, when the temperature of the environment is 400 K, the minimum detectable absorption coefficient for photothermal interferometry increases approximately 0.3% compared to the case of 300 K. The minimum detectable absorption coefficient for photoacoustic spectroscopy decreases only 0.2% compared to the case of 300 K. Photothermal interferometry differs only 0.5% point from photoacoustic spectroscopy. Thus, it is believed that photothermal interferometry is reliably comparable to photoacoustic spectroscopy under 400 K.

A Correction of Color Temperature and Consistency for 3D Stereoscopic Images (3D 입체영상을 위한 색온도와 색 일치 보정)

  • Kim, Jeong-Yeop;Kim, Sang-Hyun
    • The KIPS Transactions:PartB
    • /
    • v.18B no.3
    • /
    • pp.139-146
    • /
    • 2011
  • The color correction is the important process of influencing on the picture quality of the 3D stereoscopic images. Existing colorcorrecting methods handle the processing intensifying a correspondence among a left and right image using a histogram based on any one side. In case of color correction based on a histogram, it is difficult to correct tone of image, because the color temperature is not converted enough. And in this paper, the color temperature correction and color consistency correction is proposed without using histogram. The proposed color correction method by color temperature gives 3 in CIE-${\Delta}E$ for each pixel on the images captured with same illuminants and the conventional gives similar results. For color consistency, the proposed gives 9 in CIE-${\Delta}E$ on the images captured with different illuminants while the conventional gives 18. The proposed method shows better results than the conventional in color consistency processing.

Development of a High-Resolution Near-Surface Air Temperature Downscale Model (고해상도 지상 기온 상세화 모델 개발)

  • Lee, Doo-Il;Lee, Sang-Hyun;Jeong, Hyeong-Se;Kim, Yeon-Hee
    • Atmosphere
    • /
    • v.31 no.5
    • /
    • pp.473-488
    • /
    • 2021
  • A new physical/statistical diagnostic downscale model has been developed for use to improve near-surface air temperature forecasts. The model includes a series of physical and statistical correction methods that account for un-resolved topographic and land-use effects as well as statistical bias errors in a low-resolution atmospheric model. Operational temperature forecasts of the Local Data Assimilation and Prediction System (LDAPS) were downscaled at 100 m resolution for three months, which were used to validate the model's physical and statistical correction methods and to compare its performance with the forecasts of the Korea Meteorological Administration Post-processing (KMAP) system. The validation results showed positive impacts of the un-resolved topographic and urban effects (topographic height correction, valley cold air pool effect, mountain internal boundary layer formation effect, urban land-use effect) in complex terrain areas. In addition, the statistical bias correction of the LDAPS model were efficient in reducing forecast errors of the near-surface temperatures. The new high-resolution downscale model showed better agreement against Korean 584 meteorological monitoring stations than the KMAP, supporting the importance of the new physical and statistical correction methods. The new physical/statistical diagnostic downscale model can be a useful tool in improving near-surface temperature forecasts and diagnostics over complex terrain areas.

COMPARISON OF ATMOSPHERIC CORRECTION ALGORITHMS FOR DERIVING SEA SURFACE TEMPERATURE AROUND THE KOREAN SEA AREA USING NOAA/AVHRR DATA

  • Yoon, Suk;Ahn, Yu-Hwan;Ryu, Joo-Hyung;Won, Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.518-521
    • /
    • 2007
  • To retrieve Sea Surface Temperature(SST) from NOAA-AVHRR imagery the spilt window atmospheric correction algorithm is generally used. Recently, there have been various new algorithms developed to process these data, namely the variable-coefficient split-window, the R54 transmittance-ratio method, fixed-coefficient nonlinear algorithm, dynamic water vapour (DWV) correction method, Dynamic Water Vapour and Temperature algorithm (DWVT). We used MCSST (Multi-Channel Sea surface temperature) and NLSST(Non linear sea surface temperature) algorithms in this study. The study area is around the Korea sea area (Yellow Sea). We compared and analyzed with various methods by applying each Ocean in-situ data and satellite data. The primary aim of study is to verify and optimize algorithms. Finally, this study proposes an optimized algorithm for SST retrieval.

  • PDF

Bias Correction for Aircraft Temperature Observation Part I: Analysis of Temperature Bias Characteristics by Comparison with Sonde Observation (항공기 온도 관측 자료의 편향 보정 Part I: 존데와 비교를 통한 온도 편향 특성 분석)

  • Kwon, Hui-nae;Kang, Jeon-ho;Kwon, In-Hyuk
    • Atmosphere
    • /
    • v.28 no.4
    • /
    • pp.357-367
    • /
    • 2018
  • In this study, the temperature bias of aircraft observation was estimated through comparison with sonde observation prior to developing the temperature bias correction method at the Korea Institute of Atmospheric Prediction Systems (KIAPS). First, we tried to compare aircraft temperature with collocated sonde observations at 0000 UTC on June 22, 2012. However, it was difficult to estimate the temperature bias due to the lack of samples and the uncertainty of the sonde position at high altitudes. Second, we attempted a background innovation comparison for sonde and aircraft using KIAPS Package for Observation Processing (KPOP). The one month averaged background innovation shows the aircraft temperature have a warm bias against sonde for all levels. In particular, there is a globally distinct warm bias about 0.4 K between 200 hPa and 300 hPa corresponding to flight level. Spatially, most of the areas showed the warm bias except for below 300 hPa in some part of China at 0000 and 1200 UTC and below 850 hPa in Australia at 0000 UTC. In general, the temperature bias was larger at 1200 UTC than 0000 UTC. Based on the estimated temperature bias, we have applied the static bias correction method to the aircraft temperature observation. As a result, the warm bias of the aircraft temperature has decreased at most levels, but a slight cold bias has occurred in some areas.

Improving usage of the Korea Meteorological Administration's Digital Forecasts in Agriculture: III. Correction for Advection Effect on Determination of Daily Maximum Temperature Over Sloped Surfaces (기상청 동네예보의 영농활용도 증진을 위한 방안: III. 사면 일 최고기온 결정에 미치는 이류효과 보정)

  • Kim, Soo-Ock;Yun, Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.16 no.4
    • /
    • pp.297-303
    • /
    • 2014
  • The effect of solar irradiance has been used to estimate daily maximum temperature, which make it possible to reduce the error inherent to lapse-rate based elevation difference correction in mountainous terrain. Still, recent observations indicated that the effect of solar radiation would need correction for estimation of daily maximum temperature. It was attempted to examine what would cause the variability of solar irradiance effect in determination of daily maximum temperature under natural field conditions and to suggest improved methods for estimation of the temperature distribution over mountainous regions. Temperature at 1500 and the wind speed for 1100 to 1500 were obtained at 10 validation sites with various topographical features including slope and aspect within a mountainous $50km^2$ catchment for 2012-2013. Lapse-rate corrected temperature estimates on clear days were compared with these observations, which would represent the differential irradiance effect among sloped surfaces. Results indicated a negative correlation between the mean wind speed and the estimation error. A simple scheme was derived from relationship between wind speed and estimation error for daily temperature to correct the effect of solar radiation. This scheme was incorporated into an existing model to estimate daily maximum temperature based on the effect of solar radiation. At 10 validation sites on clear days, estimates of 1500 LST temperature with and without the correction scheme were compared. It was found that a substantial improvement was achieved when the correction scheme was applied in terms of bias correction as well as error size reduction at all sites.

A Numerical Study on Temperature Prediction Bias using FDS in Simulated Thermal Environments of Fire (모사된 화재의 열적환경에서 FDS를 이용한 온도 예측오차에 관한 수치해석 연구)

  • Han, Ho-Sik;Kim, Bong-Jun;Hwang, Cheol-Hong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.14-20
    • /
    • 2017
  • A numerical study was conducted to identify the predictive performance for the bare-bead thermocouple (TC) using FDS (Fire Dynamics Simulator) in simulated thermal environments of fire. A relative prediction bias of TC temperature calculated from reverse-radiation correction by FDS was evaluated with the comparison of previous experimental data. As a result, it was identified that the TC temperatures predicted by FDS were lower than the temperatures measured by bare-bead TC for the ranges of heat flux and gas temperature considered. The relative prediction bias of TC temperature by FDS was gradually increased with the increase in radiative heat flux and also significantly increased with the decrease in the gas temperature. Quantitatively, at the gas temperature of $20^{\circ}C$, the TC temperature predicted by FDS had the relative bias of approximately -20% with the radiative heat flux of $20kW/m^2$ corresponding to thermal radiation level of the flashover. It is predicted from the present study that more accurate validation of fire modeling will be possible with the quantitative prediction bias occurred in the process of reverse-radiation correction of temperature predicted by FDS.

Effect of Ambient Temperature on Bovine Erythrocyte Sedimentation Rate as Measured by Angled Capillary Method (경사모세관법에 의한 우의 적혈구침강 속도에 미치는 환경온도의 영향)

  • Kim Kyeong-Jin;Lee Bang-Whan
    • Journal of Veterinary Clinics
    • /
    • v.4 no.1
    • /
    • pp.395-401
    • /
    • 1987
  • In this study, the effect of ambient temperature on the 45$^{\circ}$micro ESR/hr of cattle blood were observed, and a correction chart for correcting observed values at any ambient temperature to standard values at 20$^{\circ}C$ was plotted. Besides, the effect of storage temperature of blood on the 45$^{\circ}$micro ESR/hr was surveyed. The results were as follows: 1. The values of the 45$^{\circ}$micro ESR/hr were increased as the ambient temperature were elevated(P<0.01), and lower the value of PCV, higher the effect of temperature on the 45$^{\circ}$micro ESR/hr was observed(P<0.01). 2. Regression of values of 45$^{\circ}$micro ESR to ambient temperature in all the group of different level of blood PCV showed linear regression with the highly significant coefficient of correlation. With the results, correction chart was drawn as in Fig. 1. 3. In the purpose to verify the reliability of correction chart, observed values of 45$^{\circ}$micro ESR/hr in field(out door) were corrected to values at 20$^{\circ}C$ by the correction chart(Fig. 1), comparing with the observed values at 20$^{\circ}C$ of standard temperature. No significant differences were found between two groups mentioned above. 4. In the study on the effect of storage temperature of the blood on the 45$^{\circ}$micro ESR/hr, group of storage temperature at 5$^{\circ}C$ showed statistically no significant differences untill 24 hours in contrast with standard control group.

  • PDF

Color temperature transformation of high dynamic range images

  • Kim, Yoon-Ah;Byun, Seong-Chan;Lee, Byung-Uk
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.334-336
    • /
    • 2009
  • Estimation and correction of color temperature of digital images are basis of white balance adjustment after image acquisition stage. White balance is one of the most important image processing techniques for subjective image quality enhancement. Correction of color temperature is applied for white balance adjustment or for changing the mood of a picture. A picture taken under the daylight can be changed to have a mood of sunset or cloudy day, for example. We evaluate color temperature transformation of high dynamic range images in linear and log domain, and we conclude that linear domain transformation shows better results.

  • PDF

The Correction of Fluid Temperature for Hot-wire Anemometer (열선 유속계에 대한 유체 온도의 보정)

  • 심상학
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.6
    • /
    • pp.92-97
    • /
    • 1999
  • This paper reports by simple method that is quickly corrected the effects of fluid temperature for the hot wire anemometer. We are concerned with a variable output of hot wire anemometer on arbitrary fluid temperature. Hot wire by measuring boundary layer of turbulent flow has been calibrated by arbitrary temperature lower than 10$0^{\circ}C$, and velocity lower than 20m/s. As a result, we could pick up the temperature factor affected by output of hot wire anemometer from related in output of arbitrary temperature to output of room temperature. By using temperature factor on the output of hot wire anemometer, we also obtained that the relationship of velocity was of no effect by temperature of fluids. About results of calibrated hot wire, uncertainly of velocity is 2.15% at room temperature and 3.1% at arbitrary temperature.

  • PDF