• Title/Summary/Keyword: temperature characteristic

Search Result 2,914, Processing Time 0.035 seconds

Study on Ammonia Emission Characteristic of Pig Slurry (양돈 슬러리의 암모니아 발생 특성에 관한 연구)

  • Lee S.H.;Yun N.K.;Lee K.W.;Lee I.B.;Kim T.I.;Chang J.T.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • Ammonia emission from swine production process originates from three major sources: manure storage facility, swine housing, and land application of manure. Most of the ammonia gas that are emitted from swine production operations is the by-product of aerobic or anaerobic decomposition of swine waste by microorganism. Knowing the ammonia emission rate is necessary to understand how management practices or alternative manure handling process could reduce impacts of this emission on the environment and neighbors. Ammonia gas emission from pig slurry is very difficult to predict because it is affected by many factors including wind speed of slurry surface, temperature or pH of the swine slurry, sort breed differences and classes, and diets. This study was carried out to effects of pH and temperature on ammonia gas emission from growing-finishing pig slurry. Treated far slurry in this study were pH and temperature. Results showed that pH of slurry variable changes 5, 6, 7, 8 upon an addition of NaOH and $HNO_3$, respectively. The temperature of the slurry which was contained in a water bath maintained at increasing levels ranging from 10 to $35^{\circ}C$. Ammonia emission rate of influenced pH and temperature such that the increase in pH or temperature resulted to an increase in ammonia emission. The ammonia gas was not detected at pH 5 and 6. Moreover, at a slurry of pH 8, the ammonia ranged from 28 to 60ppm and 8-29 ppm at slurry pH of 7 while temperature was 13 to $33^{\circ}C$. When slurry pH was>6, the ammonia emission was significantly increased according to rise in temperature in contrast to acid treatment of the pH. There was also a significantly increase in ammonia emission relative to slurry pH of 7 to 8. The above findings showed that to effectively reduce ammonia emission from slurry of growing-finishing pigs, the pH and temperature should be maintained a low levels.

  • PDF

Temperature Control of BIPV system considering out air temperature (외기온도를 고려한 BIPV 시스템의 온도제어)

  • Baek, Jeong-Woo;Ko, Jae-Sun;Choi, Jung-Sik;Kang, Sung-Jun;Jang, Mi-Geum;Kim, Soon-Young;Chung, Dong-Hwa
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.371-374
    • /
    • 2009
  • This paper presents a cooling system using thermoelectron for improving the output of BIPV module. The temperature characteristic in regard to improving the output of BIPV system has rarely been studied up to now but some researchers only presented the method using a ventilator. The cooling system efficiency of BIPV module applied to a ventilator mainly depends on the weather such as wind, insolation etc. Because the cooling system of BIPV module using a ventilator is so sensitive, that is being set off by wind speed at all time but is unable to operate in the NOCT(Nominal Operating Cell Temperature) which is able to make the maximum output The paper presents the cooling system using thermoelectron so as to solve such problems. The temperature control of thermoelectron can be controlled independently in the outside environment because that is performed by micro-controller. The temperature control of thermoelectron, also, can be operated around NOCT through algorism of the temperature control. Therefore, outputs of the whole system increase and the efficiency rises. The paper demonstrates the validity of proposed method by comparing the data obtained through a experiment of the cooling method of BIPV using a ventilator and proposed thermoelectron.

  • PDF

A Study on the Operation Condition by Electrical Fault in the High Temperature Fuel Cell Plant (고온 연료전지 발전단지의 내부계통 고장에 의한 운전환경에 대한 분석)

  • Chong, Young-Whan;Chai, Hui-Seok;Kim, Jae-Chul;Cho, Sung-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.51-59
    • /
    • 2013
  • High temperature fuel cell system, such as molten carbonate fuel cells(MCFC) and solid oxide fuel cells(SOFC), are capable of operating at MW rated power output. The power output change of high temperature fuel cell imposes the thermal and mechanical stresses on the fuel cell stack. To minimize the thermal-mechanical stresses on the stack, increases in the power output of high temperature fuel cell typically must be made at a slow rate. So, the short time interruption of high temperature fuel cell causes considerable generated energy losses. Because of the characteristic of high temperature fuel cell, we analyzed the impact of electrical fault in the fuel cell plant on other fuel cell generators in the same plant site. A various grounding configuration and voltage sag are analyzed. Finally, we presented the solution to minimize the effect of fault on other fuel cell generators.

Application of time-temperature indicators for cooling and frozen food storage and distribution (저장 조건 감지 지표 장치의 특성 및 식품에의 응용 가능성)

  • An, Duek-Jun;Yoo, Seung-Seok
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.5 no.1
    • /
    • pp.25-29
    • /
    • 1999
  • Time-temperature indicators (TTI) from three different companies obtained and were attached to food packages materials to evaluate degree of their color change according to storage time and temperature. Five temperature (-10 -5, 0, 5 and 10) was selected to represent standard freezing, refrigerating and room temperature, and evaluated performance by color change based on magnitude of color change and hunter system (L, a, b). Response end point was measured and recorded to find characteristic of each indicator. Comparison and discussion were conducted for accuracy and precision of each time-temperature. More research should be conducted at variable temperature and with various food to determine applicability of TTI on various storage condition.

  • PDF

Effect of Alloying Element on the High Temperature Tensile Property of Ferritic Stainless Steel for Automotive Exhaust System (자동차용 페라이트계 스테인리스강의 고온인장성질에 미치는 합금원소의 영향)

  • Song, J.Y.;Lee, I.S.;Ahn, Y.S.
    • Journal of Power System Engineering
    • /
    • v.14 no.1
    • /
    • pp.59-64
    • /
    • 2010
  • Ferritic stainless steel is currently increasingly used for automotive exhaust material. The material for exhaust manifold is used in the temperature range of 500∼$850^{\circ}C$. Therefore, high temperature characteristic is an important one that affects it's life span. It has been investigated the effect of alloying elements of Cr, Mo, Nb, Ti in the ferritic stainless steel for exhaust manifold on the high temperature tensile strength. There was a few difference in the tensile strength at $600^{\circ}C$ with the exception of low Cr steel, but the steels containing higher Cr, Mo or Nb elements showed significantly higher tensile strength at the temperature of $800^{\circ}C$. The precipitates of the specimens after heat treating at the test temperature were electrolytic extracted, and quantitatively analysed using by SEM-EDS and TEM. The alloying elements of Cr and Mo increased the tensile strength as a solid solution strengthener, and on the other hand Nb element enhanced the strength by forming the fine intermetallic compounds such as NbC or $Fe_2Nb$.

Characteristics of Temperature Distribution of Axially Loaded CFT Column with Fire Protection (축하중을 받는 내화피복 CFT기둥의 온도분포 특성)

  • Kim, Hae-Soo;Yoon, Sung-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.78-85
    • /
    • 2010
  • When the fire occur, concrete filled steel tube(CFT) columns expected to form a much distinction in a fire resistance performance according to a kind of fire protection because the steel surface is directly exposed to high temperature. In this study, an experiment by three factors which were kind of fire protection, thickness of protection and time was performed to get the characteristics of temperature distribution types of CFT column with fire protection. As the result of this study, on a basis of heating temperature, spray protection was the most superior in a fire resistance performance, fireproof paint was next, and without fire protection was most inferior. In a heating time-location relationship, the temperature increased slowly on the surface of the concrete, but the temperature increased sharply on the surface of the steel.

The Microfluidic Device using Viscosity Deviation of Magnetic Fluids Due to Temperature Changes (자성유체의 온도에 따른 점성 변화를 이용한 미소 유체 소자)

  • Choi, Bum-Kyoo;Oh, Jae-Geun;Ahn, Jeong-Jae
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.473-478
    • /
    • 2004
  • This study focused on the charateristic of magnetic fluids, the viscosity deviation of magnetic fluids due to temperature changes, and fabrication of a 'purely' liquid type microvalve. The viscosity of magnetic fluids decreases sharply during increasing of temperature. The viscosity of magnetic fluids is rated 1,000 cP at the room temperature and 25 cP when the temperature reaches $100^{\circ}C$. Briefly, it is remarkable that the fluid flow can be controlled by the temperature and this characteristic can be adopted to the microfluidics as a microvalve. The fabrication of a liquid type microvalve is more easy than solid state microvalves and which can increase an efficiency of the controlability with respect to the thermo-pneumatic micropump which is studied broadly for many years. When the magnetic fluid used as a sealant for high level sealing, the pressure leakage is less than solid state microvalve. The experimental results show that the pressure drop in microchannel, filled with the magnetic fluid, is significant in the temperature range of $20^{\circ}C{\sim}50^{\circ}C$ and this result explains why the use of magnetic fluids is possible as a microvalve searcher uses this characteristics. Well known thermo-pnumatic.

The Study on Thermal Characteristic of the Balcony with Natural Ventilation System (자연환기시스템을 부착한 발코니의 열적 특성에 관한 연구)

  • Cho Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.347-354
    • /
    • 2005
  • This paper compared vertical temperature distribution between the existing balcony model without ventilator facilities and the improved balcony model with ventilator facilities using differential equation. As the air inside of balcony is heated by solar radiation this heated air is not exhausted in the existing balcony, remaining stagnant. The air temperature distribution was $26.7{\sim}29.3^{\circ}C$ in balcony without natural ventilator system. This heated air affected the rising air temperature of adjacent spaces such as living room and bedroom in the existing balcony. But, as the heated air inside of the improved balcony model is exhausted through natural ventilator facilities in summer, the air temperature in balcony has fallen. The air temperature distribution in improved balcony was $24.8{\sim}26.7^{\circ}C$ for the inlet air speed of 1 m/s and $24.6{\sim}26.7^{\circ}C$ for the inlet air speed of 3 m/s. The energy consumption of the improved balcony is 2.5 times less than of the existing balcony. The improved balcony with the closed damper makes a roll as the existing balcony in the aspect of the heating effect. When the heated air in the improved balcony is supplied, the air temperature is raised and the ventilation effect in adjacent spaces was improved.

Performance Test of Turbine Flowmeter According to Temperature Variation (온도변화에 따른 터빈유량계의 성능 시험)

  • Nam, Ki Han;Park, Jong Ho;Kim, Hong Jip
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.2
    • /
    • pp.47-52
    • /
    • 2017
  • In general industry, TFM(turbine flow meters) as measuring instruments having high reliability are widely used in the trade of petroleum and in the measurement of tap water and hot water. The TFM is performed calibration for using in the field and is mainly calibrated at room temperature. Since accuracy of TFM depends on Reynolds number of fluid, TFM is calibrated at same Reynolds number by changing flow rate. Furthermore, the TFM using a fluid of high temperature should have considered for other factors such as the thermal expansion of the parts and characteristics change is unknown changes in the turbine flow meter accordingly. In this paper, two turbine flowmeter are experimentally studied about characteristics change using the facilities which can change fluid temperature from 6 degree celsius to 90 degree celsius. As a result, the turbine flow meter can be calibrated to minimize the error characteristic at a similar temperature and the actual temperature.

A Study in The Efficiency Improvement of Thermal Plasma Gas Processor Through Fluid Dynamics Analysis of Reaction Zone (반응부의 유동해석을 통한 열플라즈마 가스처리기의 효율 개선)

  • SeoMun, Jun;Chung, Jin-Do;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.669-673
    • /
    • 2011
  • This study explores the numerical analysis method of fluid dynamics in the reaction section to improve the gas processing efficiency in the hazardous gas removal by atmospheric thermal plasma. This study also intends to contribute in technology advance to improve the processing efficiency and make the process more stable. Numerical analysis of temperature distribution in the reaction section dependent on the change in flow velocity of Ar and plasma temperature change, which are major control variables in the cracking process of HFC-23 using arc plasma, was done. The characteristic of incoming oxygen by temperature suggested that when temperature increased to 1600K, 1700K, 1800K respectively, the range of cracking temperature 1500K increased to 75.0%, 83.3%, 90.2% respectively. The temperature change of Ar by velocity change was widest in the area higher than 1500K when the velocity was 2.5m/s; however, since there was no big difference when the velocity was 2m/s, it is believed that 2 m/s would be most proper.