• Title/Summary/Keyword: temperature characteristic

Search Result 2,919, Processing Time 0.035 seconds

Characteristic Analysis of Underwater Bearing for Canned-Type Electric Water Pump (캔드타입 전동워터펌프용 수중베어링의 특성분석)

  • Park, In Kyum;Kim, Hyung Jin;Hong, Nam Pyo;Seo, Young Ho;Kim, Byeong Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.2
    • /
    • pp.186-193
    • /
    • 2014
  • This paper presents characteristic analysis of underwater bearing for canned type electric water pump. Characteristic analysis of underwater bearing was performed using self-developed performance tester, which capable of torque change, noise change, motor speed change and abrasion loss test with respect to temperature change of underwater bearing. The performance tester can be monitored in real time by designing the control unit using the Labview program. The performance experiment was performed through comparison of the silicon carbide (SIC) and the carbon bearing. From the experiment results, performance of SIC bearing was better than carbon bearing at the abrasion and temperature experiment.

Enzymatic Treatment of Polyamide Fiber by Alcalase (알칼라제를 이용한 폴리아미드 섬유의 효소가공)

  • Song, Yu-Sun;Song, Wha-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.8
    • /
    • pp.1006-1013
    • /
    • 2011
  • An enzymatic treatment method using alcalase was introduced to improve the moisture characteristic of the polyamide fiber. The alcalase treatment conditions such as the pH, treatment temperature, enzyme concentration, and treatment time were optimized by measuring the amino groups. The changes in the weight loss, tensile strength, moisture regain, water contact angle (WCA), and water absorption rate of the polyamide fiber with the changes in the alcalase treatment conditions were evaluated. The optimum alcalase treatment conditions for polyamide fiber were found to be a treatment temperature of 50oC, a treatment time of 50 minutes, an alcalase concentration of 10% (owf), and a pH of 7.0. The ethylenediaminetetraacetic acid (EDTA) and L-cysteine accelerated the activity of the enzyme; however, they did not have an effect on the amino group production of the fiber surface. The alcalase treatment of the polyamide fiber improved the fiber's moisture regain, WCA, and absorption rate due to the amino group on the fiber surface. The results showed that the alcalase treatment of polyamide fiber is an effective method to improve the moisture characteristic of the polyamide fiber.

Atmospheric Environment Prediction to Consider SST and Vegetation Effect in Coastal Urban Region (해수면온도와 식생효과를 고려한 연안도시지역의 대기환경예측)

  • Ji, Hyo-Eun;Lee, Hwa-Woon;Won, Gyeong-Mee
    • Journal of Environmental Science International
    • /
    • v.18 no.4
    • /
    • pp.375-388
    • /
    • 2009
  • Numerical simulation is essential to indicate the flow of the atmosphere in the region with a complicated topography which consists of many mountains in the inland while it is neighboring the seashore. Such complicated topography produces land and sea breeze as the mesoscale phenomenon of meteorology which results from the effect of the sea and inland. In the mesoscale simulation examines, the change of the temperature in relation to the one of the sea surface for the boundary condition and, in the inland, the interaction between the atmosphere and land surface reflecting the characteristic of the land surface. This research developed and simulated PNULSM to reflect both the SST and vegetation effect as a bottom boundary for detailed meteorological numerical simulation in coastal urban area. The result from four experiments performed according to this protocol revealed the change of temperature field and wind field depending on each effect. Therefore, the lower level of establishment of bottom boundary suitable for the characteristic of the region is necessary to figure out the atmospheric flow more precisely, and if the characteristic of the surface is improved to more realistic conditions, it will facilitate the simulation of regional environment.

A Study on the Electrical-Fire Analysis and Firing Characteristics of Power Cord by Thermal Stress (열적 피로에 의한 전원코드의 발화 특성과 전기화재 분석에 관한 연구)

  • 최충석;송길목;김향곤;김동욱;김동우
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2003.04a
    • /
    • pp.164-170
    • /
    • 2003
  • In this paper, we studied on the firing characteristics and electrical fire analysis of power cord deteriorated by thermal stress. The cross section of PVC insulating cord deteriorated by indirect flame decreased through heat convection. PVC insulating cord deteriorated by direct flame was bumpy shape. The exothermic peak of normal cord was shown at ($526.7^{\circ}C$), but the peaks or on(heat treatment temperature) ($150^{\circ}C$) cord was shown at ($299.6^{\circ}C$) and [$502.2^{\circ}C$]. The exothermic peaks according to high temperature were similar to those of amorphous carbon. In the FT-IR analysis, the absorption peak of normal cord indicated double bond of oxygen and carbon in benzene ring at 1720.0$cm^{1}$. As the HTT was high, the height of characteristic peak decreased and the peak of carbonyl group was shown at about 1625.7$cm^{-1}$. The characteristic peak of single bond(O-H) was shown at about 3479.2$cm^{-1}$. In case of the internal part of wire covering deteriorated by over current, the characteristic peak were shown at about 3417.3$cm^{-1}$ and 1600.2$cm^{-1}$. The above results show that we can distinguish the differences according to the fire pattern through the internalㆍexternal analysis of wire covering deteriorated by heat.

  • PDF

An Analysis of the I-t Characteristic of Low Voltage Distribution Line Fuse Using the FEM (유한 요소법을 이용한 저압 배전용 전선퓨즈의 I-t 특성 해석)

  • 황명환;박두기;이세현;한상옥
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.6
    • /
    • pp.74-80
    • /
    • 1997
  • In this paper, we deal with the I -t characteristic of low voltage distribution fuse (line fuse). That fuse element has two parts;One is low temperature melting element(LTME) to put up with over current and the other is high temperature melting element (HTME) which put up with large current. Melting charateristic of fuse is determined by L TME and HTME. So we verified their properties of fuse design, mathematically, by simulating the thermal and electric characteristics of each other. We simulated the I-t characteristic of line fuse by using the numerical method;Finite Element Method(FEM). Then, we could acquire very similar result at the HTME and L TME area when compared the simlation result with experimental one.

  • PDF

A Comparative Study on Buffer Characteristic of Indirect Moxibustion (격물구(隔物灸)의 격물(隔物) 특성에 따른 온열자극 비교연구)

  • Wang, Kai-Hsia;Kim, Eun-Jung;Cho, Hyun-Seok;Kim, Kap-Sung;Lee, Seung-Deok;Kim, Kyung-Ho
    • Journal of Acupuncture Research
    • /
    • v.29 no.5
    • /
    • pp.75-85
    • /
    • 2012
  • Objectives : Indirect moxibustion is one of the thermotherapy in Korean medicine and buffer of ginger and mankshood slice are common materials to be used. However it is difficult to control the power of thermal stimulation and the stimulation is greatly influenced by the characteristic of buffer. So we research on the buffer characteristic of indirect moxibustion according to the thickness, diameter and water content changes. Methods : We used thermocouples to measure temperature from surface to depth of 2, 4, 6, 8, 10, 12, 14mm on tissue model and calculated peak temperature($^{\circ}C$). The data were analyzed with student t-test and one-way ANOVA(p<0.05). Results : 1. The peak temperature of indirect moxibustion with ginger were determined by thickness of ginger slice and temperature changes according to the thickness at intervals of 1mm but according to the diameter at intervals of 4mm. 2. The peak temperature of indirect moxibustion with mankshood were determined by thickness of mankshood slice also. The peak temperature of mankshood moxibustion was higher than that of ginger moxibustion. 3. In this study, 2mm-thick-ginger slice and 3mm-thick-mankshood slice were suitable for indirect moxibustion. Variation in the thickness of which is more efficient to control the power of thermal stimulation on indirect moxibustion. 4. The more water loss we got on ginger slice, the higher peak temperature we measured at the surface of moxibustion. But the thermal stimulation was not conducted more than 2mm in the depth. 5. The thickness and water content of buffer are important in indirect moxibustion. Conclusions : The temperature of indirect moxibustion depends on the thickness of buffer than the diameter of it. Therefore, it is more efficient according to the thickness of buffer so that we control the power of thermal stimulation. And water content of buffer is one of the important factor in indirect moxibustion.

Numerical Analysis on the Increasing Temperature Characteristics of Vaporizer Fin for Liquefied Natural Gas with Super Low Temperature (초저온 액화 천연 가스용 기화기 핀의 승온 특성에 관한 수치 해석)

  • Yi, C.S.;Kong, T.W.;Lee, H.D.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.2
    • /
    • pp.81-87
    • /
    • 2005
  • This study is numerical analysis on the increasing temperature characteristics of vaporizer fin for liquefied natural gas with super low temperature. Existing LNG vaporizers use the direct contact heat transfer mode where the extreme super low temperature LNG of $-162^{\circ}C$ flows inside of the tubes and about $20^{\circ}C$air flows on outside of the fin. Recently, the vaporizers with great enhanced performance compared to conventional type have been developed to fulfill these requirements. The vaporizing characteristic of LNG vaporizer with air as heat source has a fixed iced. These characteristic cause a low efficiency in vaporizer, total plant cost and installing space can be increased. The vaporizing characteristics of LNG via heat exchanger with air are analytically studied for an air heating type vaporizer. This study is intended to supply the design data for the domestic fabrication of the thickness and angle vaporizer fin. Governing conservation equations for mass, momentum and energy are solved by STAR-CD based on an finite volume method and SIMPLE algorithm. Calculation parameter is fin thickness, setup angle and LNG temperature. If the vaporization performance of the early stage and late stage of operating is considered, the case of ${\phi}=90^{\circ}$ was very suitable. In this paper was estimated that the heat transfer was most promoted in case of THF=2mm.

  • PDF

Analysis of temperature distribution per length in highway tunnel (공용중인 고속도로 터널내 연장별 온도 조사 분석)

  • Hong, Seung-Ho;Lee, Kyung-Ha;Kim, Nag-Young;Yun, Kyong-Ku
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.3
    • /
    • pp.259-267
    • /
    • 2005
  • This paper analyzed characteristic of temperature change as well as bottom of tunnel with thermometer according to tunnel length and region during one year. And it measured temperature distribution near tunnel portal. In the paper it was known that tunnel entrance and exit have different characteristic temperature distribution in accordiance with bottom of tunnel per tunnel length. Temperature of tunnel changed from tunnel exit to fifty meter and distribution of tunnel temperature was established uniform regardless of tunnel length. But temperature distribution of tunnel changed in tunnel entrance differ from tunnel exit in the location of one hundred twenty five meter and one hundred fifty meter. Cold air inflowed from tunnel entrance have influenced with the location of one hundred twenty five meter and one hundred fifty meter.

  • PDF

A Study on the Spatial Distribution Characteristic of Urban Surface Temperature using Remotely Sensed Data and GIS (원격탐사자료와 GIS를 활용한 도시 표면온도의 공간적 분포특성에 관한 연구)

  • Jo, Myung-Hee;Lee, Kwang-Jae;Kim, Woon-Soo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.4 no.1
    • /
    • pp.57-66
    • /
    • 2001
  • This study used four theoretical models, such as two-point linear model, linear regression model, quadratic regression model and cubic regression model which are presented from The Ministry of Science and Technology, for extraction of urban surface temperature from Landsat TM band 6 image. Through correlation and regression analysis between result of four models and AWS(automatic weather station) observation data, this study could verify spatial distribution characteristic of urban surface temperature using GIS spatial analysis method. The result of analysis for surface temperature by landcover showed that the urban and the barren land belonged to the highest surface temperature class. And there was also -0.85 correlation in the result of correlation analysis between surface temperature and NDVI. In this result, the meteorological environmental characteristics wuld be regarded as one of the important factor in urban planning.

  • PDF

Remarkable impact of steam temperature on ginsenosides transformation from fresh ginseng to red ginseng

  • Xu, Xin-Fang;Gao, Yan;Xu, Shu-Ya;Liu, Huan;Xue, Xue;Zhang, Ying;Zhang, Hui;Liu, Meng-Nan;Xiong, Hui;Lin, Rui-Chao;Li, Xiang-Ri
    • Journal of Ginseng Research
    • /
    • v.42 no.3
    • /
    • pp.277-287
    • /
    • 2018
  • Background: Temperature is an essential condition in red ginseng processing. The pharmacological activities of red ginseng under different steam temperatures are significantly different. Methods: In this study, an ultrahigh-performance liquid chromatography quadrupole time-of-flight tandem mass spectrometry was developed to distinguish the red ginseng products that were steamed at high and low temperatures. Multivariate statistical analyses such as principal component analysis and supervised orthogonal partial least squared discrimination analysis were used to determine the influential components of the different samples. Results: The results showed that different steamed red ginseng samples can be identified, and the characteristic components were 20-gluco-ginsenoside Rf, ginsenoside Re, ginsenoside Rg1, and malonyl-ginsenoside Rb1 in red ginseng steamed at low temperature. Meanwhile, the characteristic components in red ginseng steamed at high temperature were 20R-ginsenoside Rs3 and ginsenoside Rs4. Polar ginsenosides were abundant in red ginseng steamed at low temperature, whereas higher levels of less polar ginsenosides were detected in red ginseng steamed at high temperature. Conclusion: This study makes the first time that differences between red ginseng steamed under different temperatures and their ginsenosides transformation have been observed systematically at the chemistry level. The results suggested that the identified chemical markers can be used to illustrate the transformation of ginsenosides in red ginseng processing.