A Study on the Electrical-Fire Analysis and Firing Characteristics of Power Cord by Thermal Stress

열적 피로에 의한 전원코드의 발화 특성과 전기화재 분석에 관한 연구

  • 최충석 (한국전기안전공사 부설 전기안전연구원) ;
  • 송길목 (한국전기안전공사 부설 전기안전연구원) ;
  • 김향곤 (한국전기안전공사 부설 전기안전연구원) ;
  • 김동욱 (한국전기안전공사 부설 전기안전연구원) ;
  • 김동우 (한국전기안전공사 부설 전기안전연구원)
  • Published : 2003.04.01

Abstract

In this paper, we studied on the firing characteristics and electrical fire analysis of power cord deteriorated by thermal stress. The cross section of PVC insulating cord deteriorated by indirect flame decreased through heat convection. PVC insulating cord deteriorated by direct flame was bumpy shape. The exothermic peak of normal cord was shown at ($526.7^{\circ}C$), but the peaks or on(heat treatment temperature) ($150^{\circ}C$) cord was shown at ($299.6^{\circ}C$) and [$502.2^{\circ}C$]. The exothermic peaks according to high temperature were similar to those of amorphous carbon. In the FT-IR analysis, the absorption peak of normal cord indicated double bond of oxygen and carbon in benzene ring at 1720.0$cm^{1}$. As the HTT was high, the height of characteristic peak decreased and the peak of carbonyl group was shown at about 1625.7$cm^{-1}$. The characteristic peak of single bond(O-H) was shown at about 3479.2$cm^{-1}$. In case of the internal part of wire covering deteriorated by over current, the characteristic peak were shown at about 3417.3$cm^{-1}$ and 1600.2$cm^{-1}$. The above results show that we can distinguish the differences according to the fire pattern through the internalㆍexternal analysis of wire covering deteriorated by heat.

Keywords