• Title/Summary/Keyword: temperature calibration

Search Result 516, Processing Time 0.028 seconds

Some Further Consideration for the Image Retrieving of Synthetic Aperture Radiometer

  • Liu, Hao;Wu, Ji;Wu, Qiong
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1349-1351
    • /
    • 2003
  • In this paper, theoretical channels model of Synthetic Aperture Radiometer is presented. Based on this model, how amplitude imbalance, phase imbalance and mutual coupling between the different channels effect brightness temperature image retrieving is analyzed. The computer simulation results are also presented to find out the cause of the along-track streaks usually appeared in the retrieved brightness temperature image. In addition, a new system calibration approach is introduced to solve this problem.

  • PDF

Application of SWAT Model for Simulating Runoff and Water Quality Considering Climate Change (기후변화에 따른 미래 유출 및 수질 모의를 위한 SWAT 모형의 적용)

  • Chung, Eun-Sung;Kim, Sang Ug;Kim, Hyeong Bae
    • Journal of Industrial Technology
    • /
    • v.36
    • /
    • pp.9-16
    • /
    • 2016
  • In the face of increasing impact of climate change due to human activities, there has been an urgent need to resolve the problem in water resources planning management and environmental engineering. Therefore SWAT model was used to identify the impacts and change in hydrological cycle and environmental aspect. The most important step for the development of SWAT model is calibration procedure. Therefore, SWAT-CUP automatic calibration module was used to find some optimal parameters in SWAT model. After calibration in the cheongmicheon basin, SWAT model is used for the projected precipitation and temperature of RCP 4.5 and 8.5 climate change scenarios in AR5. The quantity and quality using SWAT model from 2014 to 2100 were identified. Finally, this study can provide the reasonable finding on impact by climate change.

  • PDF

Development of a Sensor Calibration to Enhance the Performance of a Non-contact Laser Optical Sensor Unit (비접촉 레이저 광센서의 성능 향상을 위한 센서보정에 관한 연구)

  • Seo, Pyeong-Won;Ryu, Young-Kee;Oh, Choon-Suk;Byun, Jong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.579-581
    • /
    • 2006
  • Flat panel image display devices such as TFT LCD and PDP have required more large area and high quality control components. To control the qualities of the components, measurements of the flatness of a plate glass has been required. In order to measure the shape of the specular objects, Non-Contact Optical Sensor using Hologram laser unit was proposed. The sensor has a optical system that is composed of a Hologram laser and objective lens. The temperature of the sensor body is controlled by TEC(Thermoelectric Cooler) to maintain the same wavelength of the diode laser. In this research, we proposed the calibration scheme to make sensor real time measuring sensor. From the experimental results we see that the proposed sensor unit can measure the position of the glass surface in rial time.

  • PDF

A Study on the calibration of health monitoring system installed in rail infrastructures (철도구조물 상시계측시스템의 교정방안에 관한 연구)

  • 이준석;최일윤;이현석;고동춘
    • Journal of the Korean Society for Railway
    • /
    • v.6 no.4
    • /
    • pp.232-238
    • /
    • 2003
  • A health monitoring system becomes a very useful tool to obtain information on long term behavior of the important railway structures such as very long span and special type bridges. It can be also used to give a warning signal to the maintenance engineer when the structure shows abnormal behavior. However, due to long term use and temperature changes, the health monitoring system needs to be calibrated periodically. In this study, calibration and gauge factor readjustment process made for the health monitoring system installed in the railroad bridges and tunnel are reviewed and a few findings are updated. Future work will be concentrated on the long-term analysis of the measurement data and on the database structures so that the assessment of the structure is possible

Calibration and Verification of a Tidal Prism Eutrophication Model for the Lynnhaven Bay (U.S.A)

  • PARK Kyeong;KUO Albert Y.
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.6
    • /
    • pp.964-973
    • /
    • 1997
  • A tidal prism eutrophication model, an one-dimensional intertidal model, is developed to study water quality conditions at small coastal basins and tidal creeks. The model simulates the physical transport processes using the concept of tidal flushing. The concept is simple and straightforward, and thus is ideal for small coastal basins with complex geometry. The model, having twenty-four state variables in the water column, simulates salinity, temperature, dissolved oxygen, three algal groups, and the cycles of carbon, nitrogen, phosphorus and silica. The model is applied to the Lynnhaven Bay, a small coastal basin of Chesapeake Bay in U.S.A. The model is calibrated using the field data collected in 1994, and then is verified using the independently collected data in 1980. The model overall gives a good reproduction of the field data, partly owing to the data collected from the field surveys specifically designed for the model application. This paper presents the procedure, and the results of the model calibration and verification.

  • PDF

The Study for Transient Enhanced Diffusion of Indium and Its Application to μm Logic Devices

  • Lee Jun-Ha;Lee Hoong-Joo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.6
    • /
    • pp.211-214
    • /
    • 2004
  • We developed a new systematic calibration procedure which was applied to the calibration of the diffusivity, segregation and TED model of the indium impurity. The TED of the indium impurity has been studied using 4 different groups of experimental conditions. Although the indium is susceptible to the TED, the RTA is effective to suppress the TED effect and maintain a steep retrograde profile. Like the boron, the indium shows significant oxidationenhanced diffusion in silicon and has segregation coefficients at the $Si/SiO_2$ interface much less than 1. In contrast, however, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed technique is validated by SIMS data and $0.13 {\mu}m$ device characteristics such as $V_{th}$ and $Id_{sat}$ with errors less than $5 \%$ between simulation and experiment.

Calibration Methodology for Transient Enhanced Diffusion of indium

  • Jun Ha, Lee;Gi Ryang, Byeon;Hyeon Chan, Jo;Gwang Seon, Kim
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2003.12a
    • /
    • pp.31-34
    • /
    • 2003
  • We developed a new systematic calibration procedure which was applied to the calibration of the diffusivity, segregation and TED model of the indium impurity. The TED of the indium impurity has been studied using 4 different groups of experimental conditions. Although the indium is susceptible to the TED, the RTA is effective to suppress the TED effect and maintain a steep retrograde profile. Like the boron, the indium shows significant oxidation-enhanced diffusion in silicon and has segregation coefficients at the $Si/SiO_2$ interface much less than 1. In contrast, however, the segregation coefficient of indium decreases as the temperature increases. The accuracy of the proposed technique is validated by SIMS data with errors less than 5% between simulation and experiment.

  • PDF

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF

Structural monitoring of a wind turbine steel tower - Part I: system description and calibration

  • Rebelo, C.;Veljkovic, M.;da Silva, L. Simoes;Simoes, R.;Henriques, J.
    • Wind and Structures
    • /
    • v.15 no.4
    • /
    • pp.285-299
    • /
    • 2012
  • This paper describes the development and calibration of a structural monitoring system installed in a 80 meters high steel wind tower supporting a 2.1 MW turbine Wind Class III IEC2a erected in the central part of Portugal. The several signals are measured at four different levels and include accelerations, strains on the tower wall and inside the connection bolts, inclinations and temperature. In order to correlate measurements with the wind velocity and direction and with the turbine operational parameters the corresponding signals are obtained directly from the turbine own monitoring system and are incorporated in the developed system. Results from the system calibration, the structural identification and the initial period of data acquisition are presented in this paper.

SPACE-BORNE MICROWAVE RADIOMETER CALIBRATION/VALIDATION IN CHINA

  • Zhenzhan, Wang;Yun, Li;Shixiang, Tan
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.598-603
    • /
    • 2002
  • We summarize the activities concerning to the space-borne microwave radiometer (RAD) calibration and validation (Cal/Val) in China. It is important to know in advance the brightness temperature of a given sea surface before external calibrating RAD due to its special characteristic of system. In the paper, we analyse some modeling results on sea surface emissivity and atmospheric transmissivity at different frequencies, and compare the calculated brightness temperatures with those measurements from some air-borne microwave radiometers. We also introduced the whole contents on RAD Val and developed two methods of retrieving sea surface winds. We compared the retrievals of wind speeds to those from NDBC buoys. At last, we introduce some plans of Cal/Val for testing our RAD.

  • PDF