• Title/Summary/Keyword: temperature boundary condition

Search Result 441, Processing Time 0.021 seconds

The Theory of Boundary Distribution of the Plant and Wave Character of the Timber Line on Mt. Paektu (식물의 경계분포 이론과 백두산 삼림한계량의 파동성)

  • 장남기;심규철;이현욱;강경미;소금현
    • The Korean Journal of Ecology
    • /
    • v.21 no.5_2
    • /
    • pp.491-499
    • /
    • 1998
  • An investigation was performed to establish the mathematical theories of a vibration for the plant growth and a wave distribution of a plant population on the boundary condition of a limiting factor in the environment. The mathematical theories of the plant growth vibration and wave distribution had been elucidated by the plant growth and the timber line on the middle slope of the west side of Mt. Paektu. The Betula ermaruii composes the timber line on about 2,060 m elevation of sea label, has a growth vibration on the ground surface and takes a wave distribution due to a boundary condition of alpine temperature gradient.

  • PDF

Design Characteristics Analysis for Very High Temperature Reactor Components (VHTR 초고온기기 설계특성 분석)

  • Kim, Yong Wan;Kim, Eung Seon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.85-92
    • /
    • 2016
  • The operating temperature of VHTR components is much higher than that of conventional PWR due to high core outlet temperature of VHTR. Material requirements and technical issues of VHTR reactor components which are mainly dominated by high temperature service condition were discussed. The codification effort for high temperature material and design methodology are explained. The design class for VHTR components are classified as class A or B according to the recent ASME high temperature reactor design code. A separation of thermal boundary and pressure boundary is used for VHTR components as an elevated design solution. Key design characteristics for reactor pressure vessel, control rod, reactor internals, graphite reflector, circulator and intermediate heat exchanger were analysed. Thermo-mechanical analysis of the process heat exchanger, which was manufactured for test, is presented as an analysis example.

Evaluation of Upper Ocean Temperature and Mixed Layer Depth in an Eddy-permitting Global Ocean General Circulation Model (중해상도 전지구 해양대순환 모형의 상층 수온과 혼합층 깊이 모사 성능 평가)

  • Jang, Chan-Joo;Min, Hong-Sik;Kim, Cheol-Ho;Kang, Sok-Kuh;Lie, Heung-Jae
    • Ocean and Polar Research
    • /
    • v.28 no.3
    • /
    • pp.245-258
    • /
    • 2006
  • We investigated seasonal variations of the upper ocean temperature and the mixed layer depth (MLD) in an eddy-permitting global ocean general circulation model (OGCM) to assess the OGCM perfermance. The OGCM is based on the GFDL MOM3 which has a horizontal resolution of 0.5 degree and 30 vertical levels. The OGCM was integrated for 68 years using a monthly-mean climatological wind stress forcing. The model sea surface temperature (SST) and sea surface salinity were restored to the Levitus climatology with a time scale of 30 days. Annual-mean model SST shows a cold bias $(<\;-2^{\circ}C)$ in the summer hemisphere and a warm bias $(>\;1^{\circ}C)$ in the winter hemisphere mainly due to the restoring boundary condition of temperature. The model MLD captures well the observed features in most areas, with a slightly deep bias. However, in the Ross Sea and Weddell Sea, the model shows significantly deeper MLD than the climatology-mainly due to weak salinity stratifications in the model. For amplitude of seasonal variation, the model SST is smaller $(1{\sim}3^{\circ}C)$ than the observation largely due to the restoring surface boundary condition while the model MLD has larger seasonal variation $({\sim}50m)$. It is suggested that for more realistic simulation of the upper ocean structure in the present eddy-permitting ocean model, more refinements in the surface boundary condition for the thermohaline forcing and parameterization for vertical mixing are required, together with the incorporation of a sea-ice model.

Effect of boundary conditions on modal parameters of the Run Yang Suspension Bridge

  • Li, Zhijun;Li, Aiqun;Zhang, Jian
    • Smart Structures and Systems
    • /
    • v.6 no.8
    • /
    • pp.905-920
    • /
    • 2010
  • Changes in temperature, loads and boundary conditions may have effects on the dynamic properties of large civil structures. Taking the Run Yang Suspension Bridge as an example, modal properties obtained from ambient vibration tests and from the structural health monitoring system of the bridge are used to identify and evaluate the modal parameter variability. Comparisons of these modal parameters reveal that several low-order modes experience a significant change in frequency from the completion of the bridge to its operation. However, the correlation analysis between measured modal parameters and the temperature shows that temperature has a slight influence on the low-order modal frequencies. Therefore, this paper focuses on the effects of the boundary conditions on the dynamic behaviors of the suspension bridge. An analytical model is proposed to perform a sensitivity analysis on modal parameters of the bridge concerning the stiffness of expansion joints located at two ends of bridge girders. It is concluded that the boundary conditions have a significant influence on the low-order modal parameters of the suspension bridge. In addition, the influence of vehicle load on modal parameters is also investigated based on the proposed model.

Analytical Structural Stability Evaluation for H-section Beams Made of Ordinary Structural Steels Based on Boundary Conditions at High Temperatures (일반 구조용 강재 적용 정정 및 부정정 보부재의 고온 시 해석적 내력 평가 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.33-38
    • /
    • 2015
  • Loads applied on the floor are transferred through beams to columns. The beams can be designed as both end fixed or simple beams. The load bearing capacity of a beam depends on each boundary condition. However, when the load bearing capacity of a beam is evaluated in fire tests, all kinds of beams are tested using simple beam conditions. In this study, an analytical method performed using heat transfer theory and heat stress analysis based on the mechanical and thermal properties of SS-400 steel at high temperature. This method was used to clarify the differences between the two types of boundary conditions at normal and high temperature. The results show that the load bearing capacity of a both-end fixed beam at high temperature is superior to that of a simple beam. Therefore, the application of simple beam conditions in fire tests for evaluation of load bearing capacity is conservatively safe compared to fixed boundary conditions.

A Boundary Element Solution Approach for the Conjugate Heat Transfer Problem in Thermally Developing Region of a Thick Walled Pipe

  • Choi, Chang-Yong
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2230-2241
    • /
    • 2006
  • This paper presents a sole application of boundary element method to the conjugate heat transfer problem of thermally developing laminar flow in a thick walled pipe when the fluid velocities are fully developed. Due to the coupled mechanism of heat conduction in the solid region and heat convection in the fluid region, two separate solutions in the solid and fluid regions are sought to match the solid-fluid interface continuity condition. In this method, the dual reciprocity boundary element method (DRBEM) with the axial direction marching scheme is used to solve the heat convection problem and the conventional boundary element method (BEM) of axisymmetric model is applied to solve the heat conduction problem. An iterative and numerically stable BEM solution algorithm is presented, which uses the coupled interface conditions explicitly instead of uncoupled conditions. Both the local convective heat transfer coefficient at solid-fluid interface and the local mean fluid temperature are initially guessed and updated as the unknown interface thermal conditions in the iterative solution procedure. Two examples imposing uniform temperature and heat flux boundary conditions are tested in thermally developing region and compared with analytic solutions where available. The benchmark test results are shown to be in good agreement with the analytic solutions for both examples with different boundary conditions.

An Experimental Study about Fire Resistance effect on Boundary Condition of CFT Column under Loading in Fire (CFT기둥 재하가열 실험에서의 경계조건에 따른 내화성능 영향에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Park, Kyung-Hun;Cho, Kyung-Suk;Kwon, In-Kyu
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.389-394
    • /
    • 2010
  • A concrete filled square steel tube (CFT) is composed of the external steel material, which its strength is reduced in fire due to sudden temperature increase, and the internal concrete with high thermal capacity that can ensure the fire resistance performance of the structure. Therefore, research about the influence factors of the structural performance of CFT column is required in order to apply CFT column to a fire resisting structure, and additional research about influence for each condition is also necessary. Among the influence factors, the boundary condition between column and beam is important structurally, and it is one of the major factors that determine overall fire resisting performance. This study performed a fire experiment under loading in order to analyse the influences of CFT column to the boundary condition. As the results of the experiment, fire resistance time of 106 minutes was ensured for the clamped-end condition but 89 minutes for the hinge-end condition in case of the 360 cross section. And, fire resistance time of 113 minutes was ensured for the clamped-end condition but 78 minutes for the hinge-end condition in case of the 280 cross section. The difference in the fire resistance performance according to changes in the boundary conditions showed a tendency that larger change effect on the fire resistance performance was derived from smaller cross section area.

  • PDF

The Effects of Thermosolutal Convection on Macrosegregation during Alloy Solidification (합금응고과정에서 이중확산대류가 거시편석에 미치는 영향)

  • Lee, Gyun-Ho;Mok, Jin-Ho;Lee, Jin-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1337-1345
    • /
    • 2001
  • Numerical investigation is made to study the effects of thermosolutal convection on the formation of macrosegregation in a Pb-Sn alloy solidification process in a two dimensional confined rectangluar mold. The basic equations are sovled using the Contrinum Model theory with the SIMPE algorithm during the solidification process. In addition, to track the liquid-solid interface with time variations, the moving boundary condition was adopted and moving irregular interface shapes were treated with the time-dependent, boundary-fitted coordinate system. As the temperature reduces from the liquidus to the solidus, the liquid concentration of Sn, the lighter constituent, increases. Then the buoyancy-driven flow due to temperature and liquid composition gradients occurs in the mushy region and forms the complicated macrosegregation maps. belated to this phenomena, effects on the macrosegregation formation depending on the cooling condition and gravity values are examined.

Boundary layer measurements for validating CFD condensation model and analysis based on heat and mass transfer analogy in laminar flow condition

  • Shu Soma;Masahiro Ishigaki;Satoshi Abe;Yasuteru Sibamoto
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2524-2533
    • /
    • 2024
  • When analyzing containment thermal-hydraulics, computational fluid dynamics (CFD) is a powerful tool because multi-dimensional and local analysis is required for some accident scenarios. According to the previous study, neglecting steam bulk condensation in the CFD analysis leads to a significant error in boundary layer profiles. Validating the condensation model requires the experimental data near the condensing surface, however, available boundary layer data is quite limited. It is also important to confirm whether the heat and mass transfer analogy (HMTA) is still valid in the presence of bulk condensation. In this study, the boundary layer measurements on the vertical condensing surface in the presence of air were performed with the rectangular channel facility WINCS, which was designed to measure the velocity, temperature, and concentration boundary layers. We set the laminar flow condition and varied the Richardson number (1.0-23) and the steam volume fraction (0.35-0.57). The experimental results were used to validate CFD analysis and HMTA models. For the former, we implemented a bulk condensation model assuming local thermal equilibrium into the CFD code and confirmed its validity. For the latter, we validated the HMTA-based correlations, confirming that the mixed convection correlation reasonably predicted the sum of wall and bulk condensation rates.

Temperature transients of piston of a Camless S.I Engine using different combustion boundary condition treatments

  • Gill, KanwarJabar Singh;Singh, Khushpreet;Cho, H.M.;Chauhan, Bhupendra Singh
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.221-230
    • /
    • 2014
  • Simplified finite element model of spark ignition (SI) engine to analyse combustion heat transfer is presented. The model was discredited with 3D thermal elements of global length 5 mm. The fuel type is petrol. Internal nodal temperature of cylinder body is defined as 21000C to represent occurrence of gasoline combustion. Material information and isotropic material properties are taken from published report. The heat transfer analysis is done for the instant of combustion. The model is validated by comparing the computed maximum temperature at the piston surface with the published result. The computed temperature gradient at the crucial parts are plotted and discussed. It has been found that the critical top surface suffered from thermal and the materials used to construct the engine parts strongly influenced the temperature distribution in the engine. The model is capable to analyze heat transfer in the engine reasonably and efficiently.