• 제목/요약/키워드: techniques

Search Result 34,610, Processing Time 0.058 seconds

The current status and control measures of BSE in the worldwide (국내, 외 광우병의 발생 현황과 대응 방안)

  • Yoo, Han-Sang
    • 한국환경농학회:학술대회논문집
    • /
    • 2009.07a
    • /
    • pp.273-282
    • /
    • 2009
  • The transmissible spongiform encephalopathies (TSEs) disease group are fatal neurodegenerative disorders affecting a wide range of hosts. The group includes kuru and Creutzfeldt-Jakob disease (CJD) in humans, scrapie in sheep and goats and Bovine spongiform encephalopathy (BSE) in cattle. The exact nature of the infectious agent involved in the transmission of these diseases remains controversial. However, a central event in their pathogenesis is the accumulation in infected tissues of an abnormal form of a host-encoded protein, the prion protein (PrP). Whereas the normal cellular protein is fully sensitive to protease ($PrP^{sen}$), the disease-associated prion protein ($PrP^d$) is only partly degraded ($PrP^{res}$), its amino-terminal end being removed. BSE was first reported in the mid-80s in the UK. Ten years later, a new form of human prion disease, variant CJD (vCJD) developed in the wake of the BSE epidemic, and there is now strong scientific evidence that vCJD was initiated by the exposure of humans to BSE-infected tissues, thus indicating a zoonotic disease. However, the ban on the feeding of animal-derived proteins to ruminants, and the apparent lack of vertical transmission of BSE, have led to a decline in the incidence of the disease within cattle herd and therefore, an assumed decreased risk for human contacting vCJD. The origin of the original case(s) of BSE still remains an enigma even though three hypotheses have been raised. Hypotheses are i) sheep- or goat-derived scrapie-infected tissues included in meat and bone meal fed to cattle, ii) a previously undetected sporadic or genetic bovine TSE contaminating cattle feed or iii) originating from a human TSE through animal feed contaminated with human remains. A host cellular membrane protein ($PrP^C$), which is abundant in central nervous system tissue, appear to be conformationally altered in the diseased host into a prion protein ($PrP^{Sc}$). This $PrP^{Sc}$ is detergent insoluble and partially protease-resistant ($PrP^{res}$). The term $PrP^{res}$ is normally used to describe the protein detected after protease treatment, in techniques such as Western immunoblotting, and enzyme-linked immunosorbant assay using fresh/frozen tissue. Immunohistochemistry may performed with formalin-fixed tissues. Also, clinical signs of the BSE are one of the major diagnostic indicators. Recently, atypical forms (known as H- and L-type) of BSE have appeared in several European countries, Japan, Canada and the United States. An unusual case was also reported in a miniature zebu. The atypical BSE fall into two groups based on the relative molecular mass (Mm) of the unglycosylated $PrP^{res}$ band relative to that of classical BSE, one of the higher Mm (H-type) and the other lower (L-type). Both types have been detected worldwide as rare cases in older animals, at a low prevalence consistent with the possibility of sporadic forms of prion diseases in cattle. This raises the unwelcome possibility that vCJD could increase in the human population. Now, active surveillance program against BSE is going on in Korea. In regional veterinary service lab, ELISA is applied to screen the BSE in slaughter and confirmatory tests by Western immunoblotting and immunohistochemisty are carried out if there are positive or suspect in the screening test. Also, the ruminant feed ban is rigorously enforced. Removal of specified risk materials such as brain and spinal cord from cattle is mandatory process at slaughter to prevent the infected material from entering the human food chain.

  • PDF

Removal Efficiency of Ammonia and Toluene using Mobile Scrubber (이동형 스크러버를 이용한 암모니아 및 톨루엔의 제거 효율)

  • Kim, Jae-Young;Kim, Jang-Yoon;Lee, Yeon Hee;Kim, Min Sun;Kim, Min-Su;Kim, Hyun Ji;Ryu, Tae In;Jeong, Jae Hyeong;Hwang, Seung-Ryul;Kim, Kyun;Lee, Jin Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.1
    • /
    • pp.49-56
    • /
    • 2018
  • BACKGROUND: The mobile vortex wet scrubber was developed to remove the harmful chemicals from accidental releases. However, there was a disadvantage that it was limitedly used for volatile organic compounds (VOCs) such as toluene according to the physicochemical properties. This study compared the removal efficiencies of an improved mobile scrubber on toluene and ammonia by applying diverse adsorption and absorption methods. METHODS AND RESULTS: The removal efficiencies on harmful chemicals were examined using various adsorption and absorption methods of water vortex process (C), phosphoric acid-impregnated activated carbon adsorption (PCA), pH-controlled water (pH 2.5) vortex process absorption with sulfuric acid (SWA) after ammonia exposure, granular activated carbon adsorption (GCA), and activated carbon mat adsorption (CMA) after toluene exposure. As a result, the best removal efficiency was shown in the SWA for ammonia and GCA for toluene. Also, the SWA and GCA methods were compared with different concentration levels. In the case of ammonia exposure (5, 10 and 25%), there was no difference by concentration levels, and the concentration in the outlet gradually increased, with pH change from acid to base. In the case of toluene exposure (50, 75 and 100%), the outlet concentration was higher relative to the exposure concentration in the initial 10 min, but the outlet concentration was remained steady after 10 min. CONCLUSION: The newly improved mobile scrubber was also effective in removing VOCs through adsorption techniques (activated carbon, activated carbon fiber, carbon mat filter etc.), as well as removing acid-base harmful chemicals by neutralization reaction.

Study on Evaluation of Carbon Emission and Sequestration in Pear Orchard (배 재배지 단위의 탄소 배출량 및 흡수량 평가 연구)

  • Suh, Sanguk;Choi, Eunjung;Jeong, Hyuncheol;Lee, Jongsik;Kim, Gunyeob;Sho, Kyuho;Lee, Jaeseok
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.4
    • /
    • pp.257-263
    • /
    • 2016
  • Objective of this study was to evaluate the carbon budget on 40 years old pear orchard at Naju. For carbon budget assessment, we measured the soil respiration, net ecosystem productivity of herbs, pear biomass and net ecosystem exchange. In 2015, pear orchard released about $25.6ton\;CO_2\;ha^{-1}$ by soil respiration. And $27.9ton\;CO_2\;ha^{-1}$ was sequestrated by biomass growth. Also about $12.6ton\;CO_2\;ha^{-1}$ was stored at pruning branches and about $5.2ton\;CO_2\;ha^{-1}$ for photosynthesis of herbs. As a result, 25.6 ton of $CO_2$ per ha is annually released to atmosphere. At the same time about 45.7 ton of $CO_2$ was sequestrated from atmosphere. When it sum up the amount of $CO_2$ release and sequestration, approximately $20.1ton\;CO_2\;ha^{-1}$ was sequestrated by pear orchard in 2015, and it showed no significant differences with net ecosystem exchanges ($17.8ton\;CO_2\;ha^{-1}\;yr^{-1}$) by eddy covariance method with the same period. Continuous research using various techniques will help the understanding of $CO_2$ dynamics in agroecosystem and it can be able to present a new methodology for assessment of carbon budget in woody crop field. Futhermore, it is expected that the this study can be used as the basic data to be recognized as a carbon sink.

Effect of Antioxidants for Porcine Oocytes during In Vitro Maturation, Fertilization and Development (돼지 난포란으로부터 체외수정란의 생산에 있어서 항산화제의 첨가가 배 발달에 미치는 효과)

  • Park H.;Kim J. Y.;Kim J. Y.;Lee J. H.;Park H. D.;Kim J. M.
    • Journal of Embryo Transfer
    • /
    • v.19 no.3
    • /
    • pp.245-255
    • /
    • 2004
  • In recent years, an increasing number of studies on pig in vitro maturation(IVM) and in vitro fertilization(IVF) have been separated. the wide range of new technologies, including that in applied molecular genetics, has increased this interest. the production of viable porcine embryos in vitro is a prerequisites for the successful production of transgenic pigs to date. The efficiency of IVM/IVF techniques in the porcine is lower than that obtained in other species such as cattle and mouse. The several problems are generally thought to be the cause of poor results: the low rate of MPN formation derived from inadequate IVM of oocytes, the high incidence of polyspermy after IVF and cell blocking at 4 cell during embryos culture. For there reasons overcoming, many studies have been conducted to improve in vitro embryo-genic competence of oocytes. In the last several years, many maturation culture media have been evaluated and various exogenous factors such as hormones and grows factors have been tested to improve the efficiency of porcine in vitro system. In the study several antioxidants have been examined to improve in vitro fertilization and development of porcine oocytes. In this study, several antioxidants were examined to determine the effects on the development of oocytes to the cleavage, morula and blastocyst stage when added at the maturation(IVM) or in vitro fertilization(IVF) or in vitro culture(IVC) of porcine embryos. Porcine oocytes were matured, fertilized and embryos were cultured in defind conditioned medium in vitro with or without supplementation with the antioxidents of cysteine, catalase and glutathione. 1. Significant improvement of blastocyst rate (27.2% versus 15.4%, p<0.05) were achieved when catalase(500U/$m\ell$) were added to TCM-199 medium and morula rate(72.0% versus 53.9%, p<0.05) were significantly higher when glutathione(1.0mM/$m\ell$) were added to TCM-199 medium than those of control. 2. In mTBM medium for oocytes fertilization, the addition of cysteine, catalase and glutathione had no positive effect on embryonic development. glutathione had no positive effect on embryonic development. In conclusion, this study shows that addition of catalase, gluththione during IVM improved the rate of porcine embryo development.

The Study on Consummer Behaviour of Poultry meat and Egg (닭고기와 계란의 소비에 대한 조사 연구)

  • 남두희;오세정
    • Korean Journal of Poultry Science
    • /
    • v.15 no.2
    • /
    • pp.81-91
    • /
    • 1988
  • The purpose of this research is to analyze the tendencies of poultry consumption in Korea. The information used is the data collected three times during the period from Sept. 1, 1985 to April 30, 1987 throughout the major cities. Those who participated in the survey are 2, 598 including housewives, nutritionists, cookers, group feeding institutions, woman's organizations, and the students of doing nutrition-related studies. Consumer preferences for poultry meat and eggs tend to move toward high quality and more strict sanitary standards. Following this line of consumer preference changes, the poultry product marketing supported by cold chain system is rapidly developing. Household consumption of poultry meat largely consists of hi-and semi-broilers but the household demand for these two broilers tends to decrease steadily over time. In general poultry meat consumption appears to be affected by consumer taste rather than market factors such as prices. In addition consumer choices are quite different depending on poultry meat parts which are preferred in order of drum sticks, wings, and breasts. In particular drum sticks are most preferred than any other parts. An important problem in poultry production is related to consumption seasonality since large part of poultry meat consumption is concentrated during the summer season. Another problem is associated with little development of cooking methods. At present there are two types of primary commercial cooking techniques, fries and samgaetang (boiled chicken with jinsang and rice). For promoting domestic poultry meat disposal and reducing the demand seasonality, new cooking methods should be developed and followed by more aggresive advertisements. In domestic egg trade, smaller packing units(i.e., 10 eggs per unit) tend to bi preferred to large ones (i.e., 30 eggs per unit). In consumers egg purchasing decisions nearness to the shops and convenience appear to be important factors. For egg shell colors consumers recognize that there is no difference in nutritional values. However, survey results show that consumers highest preference lies in eggs with brown color. Eggs are most popular among children and preferred in order of middle-and high-school students, 17-25 age people, and adults. Egg prices are concieved relatively cheap to its nutritional values. In house-holds eggs are consumed in the forms of fries, side dishes, and lunch basket dishes. However, high level of cholesterol content in eggs appears to be an important problem in promoting eggs consumption.

  • PDF

Position Uncertainty due to Multi-scattering in the Scintillator Array of Dual Collimation Camera (복합 집속 카메라의 섬광체배열에서 다중산란에 의한 위치 불확실성)

  • Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.287-292
    • /
    • 2008
  • Position information of radiation interactions in detection material is essential to reconstruct a radiation source image. With most position sensing techniques, the position information of a single interaction inside the detectors can be precisely obtained. Each interaction position of multi-scattering inside scintillators, however, can not be individually measured and only the average of the scattering positions can be obtained, which causes the uncertainty in the measured interaction position. In this paper, the position uncertainties due to the multi-scattering were calculated by Monte Carlo simulation. The simulation model was a 50 by 50 by 5 mm $LaCl_3$(Ce) scintillator(pixel size is 2 by 2 by 5mm) which was utilized for the dual collimation camera. The dual collimation camera uses the information from both photoelectric effect and Compton scattering, and therefore, position uncertainties for both partial and full energy deposition of radiation interactions are calculated. In the case of partial energy deposition(PED), the standard deviations of positions are less than $1{\sim}2mm$, which means the uncertainty caused by multi-scattering is not significant. Because the effect of the multi-scattering with PED is insignificant, the multi-scattering has little effect on the performance of Compton imaging of dual collimation camera. In the case of full energy deposition(FED), however, the standard deviation of the positions is about twice that of the pixel size of the 1stdetector, except for 122keV incident radiations. Therefore, the standard deviations caused by multi-scatterings should be considered in the design of the coded mask of the dual collimation camera to avoid artifact on the reconstructed image. The position uncertainties of the FEDs are much larger than those of the PEDs for all radiation energies and the ratio of PEDs to FEDs increases when the incident radiation energy increases. The position uncertainties of both PEDs and FEDs are dependent on the incident radiation energy.

  • PDF

Verification of Non-Uniform Dose Distribution in Field-In-Field Technique for Breast Tangential Irradiation (유방암 절선조사 시 종속조사면 병합방법의 불균등한 선량분포 확인)

  • Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Bang, Dong-Wan;Kim, Yon-Lae;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.277-282
    • /
    • 2010
  • The study is to verify non-uniform dose distribution in Field-In-Field (FIF) technique using two-dimensional ionization chamber (MatriXX, Wellhofer Dosimetrie, Germany) for breast tangential irradiation. The MatriXX and an inverse planning system (Eclipse, ver 6.5, Varian, Palo Alto, USA) were used. Hybrid plans were made from the original twenty patients plans. To verify the non-uniform dose distribution in FIF technique, each portal prescribed doses (90 cGy) was delivered to the MatriXX. The measured doses on the MatriXX were compared to the planned doses. The quantitative analyses were done with a commercial analyzing tool (OmniPro IMRT, ver. 1.4, Wellhofer Dosimetrie, Germany). The delivered doses at the normalization points were different to average 1.6% between the calculated and the measured. In analysis of line profiles, there were some differences of 1.3-5.5% (Avg: 2.4%), 0.9-3.9% (Avg: 2.5%) in longitudinal and transverse planes respectively. For the gamma index (criteria: 3 mm, 3%) analyses, there were shown that 90.23-99.69% (avg: 95.11%, std: 2.81) for acceptable range ($\gamma$-index $\geq$ 1) through the twenty patients cases. In conclusion, through our study, we have confirmed the availability of the FIF technique by comparing the calculated with the measured using MatriXX. In the future, various clinical applications of the FIF techniques would be good trials for better treatment results.

The Effects of a MR Torso Coil on CT Attenuation Correction for PET (PET/CT 검사에 있어서 MR Torso Coil의 CT 감쇄보정에 대한 영향 평가)

  • Lee, Seung Jae;Bahn, Young Kag;Oh, Shin Hyun;Gang, Cheon-Gu;Lim, Han Sang;Kim, Jae Sam;Lee, Chang Ho;Seo, Soo-Hyun;Park, Yong Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.81-86
    • /
    • 2012
  • Purpose : Combined MR/PET scanners that use the MRI for PET AC face the challenge of absent surface coils in MR images and thus cannot directly account for attenuation in the coils. To make up for the weak point of MR attenuation correction, Three Modality System (PET/CT +MR) were used in Severance hospital. The goal of this work was to investigate the effects of MR Torso Coil on CT attenuation correction for PET. Materials and Methods : PET artifacts were evaluated when the MR Torso Coil was present of CTAC data with changing various kV and mA in uniformity water phantom and 1994 NEMA cylinderical phantom. They evaluated and compared the following two scenarios: (1) The uniform cylinder phantom and the MR Torso Coil scanned and reconstructed using CT-AC; (2) 1994 NEMA cylinderical phantom and the MR Torso Coil scanned and reconstructed using CT-AC. Results : Streak artifacts were present in CT images containing the MR Torso Coil due to metal components. These artifacts persisted after the CT images were converted for PET-AC. CT scans tended to over-estimate the linear attenuation coefficient when the kV and mA is increasing of the metal components when using conventional methods for converting from CT number. Conclusion : The presence of MR coils during PET/CT scanning can cause subtle artifacts and potentially important quantification errors. Alternative CT techniques that mitigate artifacts should be used to improve AC accuracy. When possible, removing segments of an MR coil prior to the PET/CT exam is recommended. Further, MR coils could be redesigned to reduce artifacts by rearranging placement of the most attenuating materials.

  • PDF

The Understanding and Application of Noise Reduction Software in Static Images (정적 영상에서 Noise Reduction Software의 이해와 적용)

  • Lee, Hyung-Jin;Song, Ho-Jun;Seung, Jong-Min;Choi, Jin-Wook;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.54-60
    • /
    • 2010
  • Purpose: Nuclear medicine manufacturers provide various softwares which shorten imaging time using their own image processing techniques such as UlatraSPECT, ASTONISH, Flash3D, Evolution, and nSPEED. Seoul National University Hospital has introduced softwares from Siemens and Philips, but it was still hard to understand algorithm difference between those two softwares. Thus, the purpose of this study was to figure out the difference of two softwares in planar images and research the possibility of application to images produced with high energy isotopes. Materials and Methods: First, a phantom study was performed to understand the difference of softwares in static studies. Various amounts of count were acquired and the images were analyzed quantitatively after application of PIXON, Siemens and ASTONISH, Philips, respectively. Then, we applied them to some applicable static studies and searched for merits and demerits. And also, they have been applied to images produced with high energy isotopes. Finally, A blind test was conducted by nuclear medicine doctors except phantom images. Results: There was nearly no difference between pre and post processing image with PIXON for FWHM test using capillary source whereas ASTONISH was improved. But, both of standard deviation(SD) and variance were decreased for PIXON while ASTONISH was highly increased. And in background variability comparison test using IEC phantom, PIXON has been decreased over all while ASTONISH has shown to be somewhat increased. Contrast ratio in each spheres has also been increased for both methods. For image scale, window width has been increased for 4~5 times after processing with PIXON while ASTONISH showed nearly no difference. After phantom test analysis, ASTONISH seemed to be applicable for some studies which needs quantitative analysis or high contrast, and PIXON seemed to be applicable for insufficient counts studies or long time studies. Conclusion: Quantitative values used for usual analysis were generally improved after application of the two softwares, however it seems that it's hard to maintain the consistency for all of nuclear medicine studies because result images can not be the same due to the difference of algorithm characteristic rather than the difference of gamma cameras. And also, it's hard to expect high image quality with the time shortening method such as whole body scan. But it will be possible to apply to static studies considering the algorithm characteristic or we can expect a change of image quality through application to high energy isotope images.

  • PDF

Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT (영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교)

  • Kim, Woo-Hyun;Jung, Woo-Young;Lee, Ju-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: Nowadays in the nuclear medicine, many studies and efforts are being made to reduce the scan time, as well as the waiting time to be needed to execute exams after injection of radionuclide medicines. Several methods are being used in clinic, such as developing new radionuclide compounds that enable to be absorbed into target organs more quickly and reducing acquisition scan time by increase the number of Gamma Camera detectors to examine. Each medical equipment manufacturer has improved the imaging process techniques to reduce scan time. In this paper, we tried to analyze the difference of image quality between FBP, 3D OSEM reconstruction methods that commercialized and being clinically applied, and Astonish reconstruction method (A kind of Iterative fast reconstruction method of Philips), also difference of image quality on scan time. Material and Methods: We investigated in 32 patients that examined the Bone SPECT from June to July 2008 at department of nuclear medicine, ASAN Medical Center in Seoul. 40sec/frame and 20sec/frame images were acquired that using Philips‘ PRECEDENCE 16 Gamma Camera and then reconstructed those images by using the Astonish (Philips’ Reconstruction Method), 3D OSEM and FBP methods. The blinded test was performed to the clinical interpreting physicians with all images analyzed by each reconstruction method for qualitative analysis. And we analyzed target to non target ratio by draws lesions as the center of disease for quantitative analysis. At this time, each image was analyzed with same location and size of ROI. Results: In a qualitative analysis, there was no significant difference by acquisition time changes in image quality. In a quantitative analysis, the images reconstructed Astonish method showed good quality due to better sharpness and distinguish sharply between lesions and peripheral lesions. After measuring each mean value and standard deviation value of target to non target ratio with 40 sec/frame and 20sec/frame images, those values are Astonish (40 sec-$13.91{\pm}5.62$ : 20 sec-$13.88{\pm}5.92$), 3D OSEM (40 sec-$10.60{\pm}3.55$ : 20 sec-$10.55{\pm}3.64$), FBP (40 sec-$8.30{\pm}4.44$ : 20 sec-$8.19{\pm}4.20$). We analyzed target to non target ratio from 20 sec and 40 sec images. And we analyzed the result, In Astonish (t=0.16, p=0.872), 3D OSEM (t=0.51, p=0.610), FBP (t=0.73, p=0.469) methods, there was no significant difference statistically by acquisition time change in image quality. But FBP indicates no statistical differences while some images indicate difference between 40 sec/frame and 20 sec/frame images by various factors. Conclusions: In the circumstance, try to find a solution to reduce nuclear medicine scan time, the development of nuclear medicine equipment hardware has decreased while software has marched forward at a relentless. Due to development of computer hardware, the image reconstruction time was reduced and the expanded capacity to restore enables iterative methods that couldn't be performed before due to technical limits. As imaging process technique developed, it reduced scan time and we could observe that image quality keep similar level. While keeping exam quality and reducing scan time can induce the reduction of patient's pain and sensory waiting time, also accessibility of nuclear medicine exam will be improved and it provide better service to patients and clinical physician who order exams. Consequently, those things make the image of department of nuclear medicine be improved. Concurrent Imaging - A new function that setting up each image acquisition parameter and enables to acquire images simultaneously with various parameters to once examine.

  • PDF