• Title/Summary/Keyword: technical indicator

Search Result 106, Processing Time 0.025 seconds

Adsorption Analysis of Fluorescent Whitening Agent on Cellulosic Fibers by Zeta Potential Measurement (지료의 제타전위 측정을 통한 형광증백제의 흡착 평가)

  • Lee, Ji Young;Kim, Eun Hea;Kim, Chul Hwan;Park, Jong Hye
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.6
    • /
    • pp.106-112
    • /
    • 2015
  • Many researchers have proposed analytical methods to measure the adsorption of di-sulpho fluorescent whitening agents (D-FWAs), but practical methods for D-FWA utilization in an actual paper mill have not been established. In particular, the D-FWA adsorption behavior must be monitored in paper mills to ensure the effective use of D-FWAs. This study used the zeta-potential of pulps as an indicator of the adsorption behavior of a D-FWA. We identified the relationship between the actual adsorption of the D-FWA and the zeta-potential of the pulps as a function of D-FWA addition. zeta-potential measurements were then used to analyze the D-FWA adsorption behavior under different conditions of pulp type, conductivity, and pH. The actual adsorption of a D-FWA was proportional to the ${\Delta}zeta-potential$ of the pulps (i.e., the difference between the zeta-potential of a pulp containing no D-FWA and one containing the D-FWA). The ${\Delta}zeta-potential$ of the pulps was therefore adopted for adsorption analysis. A higher adsorption of the D-FWA was observed onto Hw-BKP than onto Sw-BKP because of the shorter fiber length and higher fines content of Hw-BKP. A high conductivity and an acidic pH decreased the D-FWA adsorption because of direct effects of high ion concentrations and low pH on the D-FWA solubility. Therefore, a D-FWA must be added to Hw-BKP under low conductivity conditions and at neutral or alkaline pH to optimize the D-FWA adsorption.

ATL 1.0: An Artificial Intelligence Technology Level Definition (ATL 1.0: 인공지능 기술 수준 정의)

  • Min, O.G.;Kim, Y.K.;Park, J.Y.;Park, J.G.;Kim, J.Y.;Lee, Y.K.
    • Electronics and Telecommunications Trends
    • /
    • v.35 no.3
    • /
    • pp.1-8
    • /
    • 2020
  • Artificial-intelligence (AI) technology is used in a variety of fields, from robot cleaner motion control to call center counselors, AI speakers, and Mars exploration. Because the technology levels of all applications and services that utilize AI vary widely, it is not possible to view all applications using AI technology at the same level. Nevertheless, there have been no cases in which the level of AI technology was defined. Therefore, the Electronics and Telecommunications Research Institute (ETRI) Artificial Intelligence Research Laboratory has defined the levels of the main technical elements of AI from steps 1 to 6. In this report, the Artificial Intelligence Technology Level 1.0 (ATL 1.0) is presented. It was established by comprehensively referring to the AI technology prospects and technology roadmaps of major countries. It is hoped that it can be used as a measure for determining the levels of AI applications or services or as an indicator for establishing a technology roadmap.

NUMERICAL CHANGES OF THE COLIFORM BACTERIA IN A RECIRCULATING AQUARIUM (순환여과수조수의 대장균군)

  • PARK Soo-Il
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.11 no.1
    • /
    • pp.5-8
    • /
    • 1978
  • Numerical changes of coliform bacteria in a recirculating aquarium were measured as fouling indicator. The contamination of the filter bed was mainly due to the food given to fishes, the fecal materials and the additional supply of water polluted already. Abundance of the bacteria in the aquarium was controlled by the physiochemical factors of water quality. Of these factors, pH was the main factor. Under the water temperature $20^{\circ}C$, if pH was controlled at lower than $5\~6$, the bacteria did not flourish seriously. Under the water temperature over $30^{\circ}C$, the bacterial growth was markedly decreased regardless of the pH value, and the bacterial flora seemed to be active in growth under temperature condition lower than $30^{\circ}C$.

  • PDF

Using DEA to Analyze the Degree of Global Technology Cooperation at the National Level (DEA를 활용한 국가별 글로벌 기술협력 수준 분석 : OECD 국가를 중심으로)

  • Lee, Mingook;Lee, Sungjoo
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.41 no.2
    • /
    • pp.67-80
    • /
    • 2016
  • Under a rapidly changing environment, firms have attempted to co-operate with organizations that possess high technologies to improve their technical capabilities. Most countries have worked towards developing a suitable strategy for international technology co-operation based on the diagnostic results of their technological capabilities and indices. These diagnostic results indicate the level and degree of international technology co-operation that have been developed in academia. However, identifying the overall conditions of international technology co-operation based on existing indices is a difficult task. Hence, to address this problem, indices that can measure diverse perspectives of core technology co-operation activities need to be developed. This research aims to develop a framework for identifying the current state of international technology co-operation in diverse perspectives at the national level. We develop indices based on relevant literature and formulate an analytical framework for international technology co-operation in diverse perspectives using DEA analysis. The results are expected to contribute to effective technology planning at the national level by diagnosing capabilities for international technology co-operation from diverse perspectives.

A Study on the Evaluation Method for Professional ESCO (전문 ESCO 지정제 평가방안 연구)

  • Lim, Ki Choo
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.90-95
    • /
    • 2013
  • The paper is aimed at evaluation method for technology-focused professional ESCO. We set up some premise about the evaluation indicators, there are such as the financial soundness, energy savings performance excellence, customer satisfaction, source technology vendor's participation, and guaranteed savings contract. The evaluation indicators consist of the evaluation of expertise (40points), management state (15points), customer satisfaction (20points), technical skills (25points), and detailed indicators were determined. We can apply technology categories such as lighting, cogeneration, process improvement, waste heat recovery, cooling & heating equipments.

Inquiry of Water Environment in Mihocheon (Stream) - Water Quality Monitoring focused on TOC - (미호천의 물 환경 탐구 - TOC를 중심으로 한 수질모니터링 -)

  • Lyu, Jai Hong;Lee, Du Gon
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.731-739
    • /
    • 2007
  • In this study, water quality monitoring focused on TOC was performed at 5 points in Mihocheon (Stream) from January to December 2006. And 10 parameters (water temperature, pH, DO, EC, turbidity, SS, BOD, $PO_4-P$, TOC, TN) were monitored every month for one year. According to this study, TOC increased towards the lower stream (#4~#5). Correlation coefficients between TOC and DO, EC, turbidity, SS, BOD, $PO_4-P$, TN were -0.126, 0.351, 0.320, 0.286, 0.711, 0.525, 0.666. TOC was highly related to BOD. As a result of linear regression analysis, regression equation between BOD and TOC was BOD=0.58TOC+1.90 ($R^2=0.506$). In Mihocheon (Stream), BOD/TOC ratio decreased towards the lower stream. This results show decrease of ratio of biodegradable organic material to total organic pollutants towards the lower stream. This study is significant since it has revealed the potential value of TOC as organic material indicator for inquiry of water quality characteristics in the natural water system.

Comparison of displacement capacity of reinforced concrete columns with seismic codes

  • Cansiz, Sinan;Aydemir, Cem;Arslan, Guray
    • Advances in concrete construction
    • /
    • v.8 no.4
    • /
    • pp.295-304
    • /
    • 2019
  • The lateral displacement or drift may be the cause of the damage in the reinforced concrete (RC) columns under the seismic load. In many regulations, lateral displacement was limited according to the properties of columns. The design displacement limits may be represented indirectly through the material strain limits and the mechanical properties of columns. EUROCODE-8 and FEMA356 calculate displacement limits by taking into account the mechanical properties of columns. However, Turkey Building Earthquake Code (TBEC) determine displacement limits by taking into account the material strain limits. The aim of this study is to assess the seismic design codes for RC columns through an experimental study. The estimates of seismic design codes have been compared with the experimental results. It is observed that the lateral displacement capacities of columns estimated according to some seismic codes are not in agreement with the experimental results. Also, it is observed that TBEC is conservative in the context of the performance indicator of RC columns, compared to EUROCODE-8 and FEMA356. Moreover, in this study, plastic hinge length and effective stiffness of test elements were investigated.

Measurement of the Moderator Temperature Coefficient of Reactivity for Pressurized Water Reactors

  • Yu, Sung-Sik;Kim, Se-Chang;Na, Young-Whan;Kim, H. S.;J. Y. Doo;Kim, D. K.;S. W. Long
    • Nuclear Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.488-499
    • /
    • 1997
  • The measurements of the moderator temperature coefficient (MTC) are performed to demonstrate that the calculational model produces results that are consistent with the measurements. Since negative MTC is also a technical specification value that may limit the cycle length, it is important to measure it as accurately as possible. In this report, preferred choice of test method depending on the time in cycle, best power indication and temperature definition in MTC calculation were determined based on the MTC test results taken during initial startup testing and at 2/3 cycle burnup in the Yonggwang nuclear power plant. The results show that the ratio and rodded methods provided good agreement with the predictions during initial startup testing. However, near end-of-cycle the depletion method gives better results, and so is suggested to be used in the MTC measurements at 2/3 cycle burnup. The use of primary Delta T power as a power indicator in the MTC calculations is highly advisable since it responds with good consistent results very quickly to changes unlike secondary calorimetric power. For the appropriate temperature definitions used in the MTC calculations, it is considered that the arithmetic average temperature measured simply by inlet and outlet thermocouples is preferred. Although volumetric average temperature provides better results, the improvement is not sufficient to compensate for the simplicity of calculations by arithmetic average temperature.

  • PDF

A Study on the Gamification Technology Valuation Framework (게이미피케이션 기술 가치 평가 프레임워크 연구)

  • Baek, Junho;Jang, Jintae;Jeong, Jiyong;Kim, Sangkyun
    • Journal of Korea Game Society
    • /
    • v.18 no.3
    • /
    • pp.17-26
    • /
    • 2018
  • As the concept of experience economy has been accelerated recently, user experience is more emphasized today, most of all. And related representative keywords are gamification. Gamification characterized by that intangible elements are produced and consumed through various interactions between providers and users and by having a structure that is difficult to generalize and objectify to economic value. Therefore, the purpose of the present study is to develop a quantitative valuation indicator of concept and standardize the valuation formula covering economic value for gamification technology and overall framework from the perspective of evaluating economic values of intangible technologies such as of knowledge, design, contents, and service of a company.

A Techno-Economic Feasibility Analysis on LVDC Distribution System for Rural Electrification in South Korea

  • Afamefuna, David;Chung, Il-Yop;Hur, Don;Kim, Ju-Yong;Cho, Jintae
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1501-1510
    • /
    • 2014
  • Low voltage direct current (LVDC) distribution system is a suitable techno-economic candidate which can create an innovative solution for distribution network development with respect to rural electrification. This research focuses on the use of LVDC distribution system to replace some of KEPCO's existing traditional medium voltage alternating current (MVAC) distribution network for rural electrification in South Korea. Considering the technical and economic risks and benefits involved in such project, a comparative techno-economic analysis on the LVDC and the MVAC distribution networks is conducted using economic assessment method such as the net present value (NPV) on a discounted cash flow (DCF) basis as well as the sensitivity analysis technique. Each would play a role in an economic performance indicator and a measure of uncertainty and risk involved in the project. In this work, a simulation model and a computational tool are concurrently developed and employed to aid the techno-economic analysis, evaluation, and estimation of the various systems efficiency and/or performance.