• Title/Summary/Keyword: tape method

Search Result 605, Processing Time 0.03 seconds

Fabrication of $MgB_2$ tape with metal powder addition (금속분말이 첨가된 $MgB_2$ 선재의 제조 및 특성)

  • Ko, Jae-Woong;Yoo, Jai-Moo;Kim, Young-Kuk;Chung, Kook-Chae;Yoo, Sang-Im;Wang, Xio Lin;Dou, Shi Xue
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.1-4
    • /
    • 2006
  • The $MgB_2$ tapes with several metal powder addition were fabricated by PIT method with or without heat treatment. The $J_c$ value of $5.600A/cm^2$ and $16.000A/cm^2$ at 4.2 K and 5 T were obtained for the $MgB_2$ tape and 10 vol % of Cu added $MgB_2$ tape without heat treatment respectively. The $J_c$ value of $8.000A/cm^2$ and $35,000A/cm^2$ at 4.2 K and 5 T were obtained for the $MgB_2$ tape and 10 vol. % of Al added $MgB_2$ tape with heat treatment, respectively. The $J_c-B$ curve shows enhancement in $J_c$ under magnetic field. which suggests enhancement in workability and grain connectivity with several metal powder addition.

A new manufacturing method of all ceramic restoration using alumina tape and presentation of clinical cases

  • Oh, Nam-Sik;Kim, Eui-Seong;Lee, Keun-Woo;Han, Jung-Suk;Kim, Dae-Joon;Lee, Myung-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.6
    • /
    • pp.800-805
    • /
    • 2000
  • In an effort to facilitate fabrication procedure of all ceramic crowns, a novel preparation method for all ceramic crown using alumina tape was developed. The alumina tape having a uniform thickness was cast by using Doctor blade method. The physical properties of newly introduced alumina tape has biaxial flexure strength of $500\sim600MPa$. The value of toughness is $3.18\sim3,28MPa.m^{1/2}$ which corelates with fracture and the linear shrinkage rate of the alumina tape is 0.44% during core production. The marginal fitness of the alumina tape all-ceramic restoration with $90{!`}$shoulder margin had average marginal discrepancy at $78.3{\S}$ > and average marginal gap at $44.4{\S}$ >. At the marginal preparation of $135{!`}$deep chamfer, the average marginal discrepancy at $82.1{\S}$ > and the average marginal gap at $40.2{\S}$ > had been reported. This fabrication procedure of all ceramic crowns with alumina tapes is easier and less technical sensitive for dental technicians. After restoration with new all ceramic crowns we followed the patients 2 years later, there were no complications as porcelain fractures or periodontal disease. We had good esthetic clinical results with new all ceramic crowns.

  • PDF

An Experimental Study on the Comparision over an Educational Effectiveness with the Orienting Methods by University Libraries -with an Emphasis on Video- Tape- (대학도서관 오리엔테이션 프로그램의 교육적 효율성 비교에 관한 실험연주 -비데오테이프 중심으로-)

  • Kang Mia Hye
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.17
    • /
    • pp.85-103
    • /
    • 1989
  • The purpose of this second one of the two consecutive papers, which carried out for the research, is to evaluate their relative effectiveness regarding instruction with such three presentation methods as video/print+ lecture, print/video, print+lecture/video, with which the library of Duk Sung Women's University applied already for the orientation of the freshmen in 1988. In sum, the major research findings are as follows : First, as the more numerous media were applied for the orientation, the instruction were more effective. Second, it is very interesting to find out that there were wide differences in effectiveness among the three presentation methods applied for the student. Especially, the print+ lecture/video method was more effective in the instruction than the print/video method. Surprisingly, the video/print + lecture method was much more effective than the print+ lecture/video method. With the research findings of this two consecutive papers into consideration, it seems safe to say that the video-tape method was most effective among such three orienting methods as lecture, slide-tape, and video tape, and the video/print+lecture method was most effective among such three presentation methods as video/print+lecture, print/video, and print+lecture/video.

  • PDF

Deuterium ion irradiation impact on the current-carrying capacity of DI-BSCCO superconducting tape

  • Rajput, M.;Swami, H.L.;Kumar, R.;Bano, A.;Vala, S.;Abhangi, M.;Prasad, Upendra;Kumar, Rajesh;Srinivasan, R.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2586-2591
    • /
    • 2022
  • In the present work, we have irradiated the DI-BSCCO superconducting tapes with the 100 keV deuterium ions to investigate the effect of ion irradiation on their critical current (Ic). The damage simulations are carried out using the binary collision approximation method to get the spatial distribution and depth profile of the damage events in the high temperature superconducting (HTS) tape. The point defects are formed near the surface of the HTS tape. These point defects change the vortex profile in the superconducting tape. Due to the long-range interaction of vortices with each other, the Ic of the tape degrades at the 77 K and self magnetic field. The radiation dose of 2.90 MGy degrades the 44% critical current of the tape. The results of the displacement per atom (dpa) and dose deposited by the deuterium ions are used to fit an empirical relation for predicting the degradation of the Ic of the tape. We include the dpa, dose and columnar defect terms produced by the incident particles in the empirical relation. The fitted empirical relation predicts that light ion irradiation degrades the Ic in the DI-BSCCO tape at the self field. This empirical relation can also be used in neutron irradiation to predict the lifetime of the DI-BSCCO tape. The change in the Ic of the DI-BSCCO tape due to deuterium irradiation is compared with the other second-generation HTS tape irradiated with energetic radiation.

Voltage disturbance detection method for HTS tape using electromagnetically coupled coils

  • Song, Seunghyun;Lee, Jiho;Lee, Woo Seung;Jin, Hongwoo;Hwang, Young Jin;Ko, Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.23-26
    • /
    • 2014
  • This paper represents the detection method of voltage disturbance for high temperature superconducting (HTS) tape using electromagnetically coupled coils. In order to detect the voltage as the superconductor transits from the superconducting state to the normal conduction state, voltage taps are widely used to get the voltage signal. And voltage taps are connected to data acquisition device via signal wires. However this new suggested method can detect the superconducting transition voltage without signal wires between voltage taps and data acquisition device by using electromagnetically coupled coils. This system consists of two electromagnetically coupled coils, the first coil to detect and transmit the voltage of HTS tape and the second coil to pick up the transmitted voltage from the first coil. By using this new suggested method, we can build the 'separated voltage-detection system'. HTS tape and first coil are located under liquid nitrogen vessel and the second coil is located under room temperature condition. In this paper, experiments are performed to verify the feasibility of the proposed method. As the result of the experiment, the separated voltage-detection system using electromagnetically coupled coils can successfully observe superconducting-normal transition of HTS tapes.

A Study on Microcomputer Interface to Audio Cassette Tape Recorder (Microcomputer의 음성 Cassette Tape Recorder Interface 방식에 관한 연구)

  • 이태원;박용기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.14 no.6
    • /
    • pp.16-25
    • /
    • 1977
  • In this paper is studied a method of interfacing microcomputer system with an ordinary cassette tape recorder The use of a parallel interface adapter has made it possible not only to construct a byte in software method but also to control noter operation of the recorder. Considerable improvement of the data handling speed is accomplished in spite of a relatively simplified network configurations.

  • PDF

Output Characteristics of Linear Switched Reluctance Motor with YBCO Tape Conductors

  • Hirayama, Tadashi;Asakawa, Shinichiro;Kawabata, Shuma
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.4
    • /
    • pp.394-398
    • /
    • 2013
  • This paper presents output characteristics of a linear switched reluctance motor (LSRM) with excitation windings wound by using high-temperature superconducting (HTS) tapes. In a double-sided LSRM, Bi-2223 or YBCO tape conductors are used for the excitation windings. The characteristics of the LSRM are obtained by a finite element method analysis. We can obtain large thrust compared with a conventional LSRM by using YBCO tape conductors. Also, the effect of a configuration of the YBCO coil on the thrust is calculated. We discuss a suitable coil configuration for the average thrust upgrading.

A Study on Joining Method of BSCCO(223) Multifilamentary Tape (BSCCO(2223) 다심 초전도 선재의 접합공정 연구)

  • 김정호;김규태;주진호;나완수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.6
    • /
    • pp.511-517
    • /
    • 2001
  • We evaluated the electrical properties of 37 multifilamentary jointed tapes processed by superconducting joint. In the superconducting joining method, a lap-joint was used. Tapes were selectively etched, and exposed superconducting cores of the two tapes were brought into contact with each other and then only the joined region was uniaxially pressed in the range of 1,000 to 2,50 MPa. The critical current ratio(CCR) and n-value of the jointed tape were evaluated as a function of uniaxial pressure and number of step in the contacting region. It was observed that the CCR was dependent on the number of step, but almost independent of uniaxial pressure. The highest critical current ratio and n-value were obtained to be 58% and 26%, respectively, for the jointed tape to the tape itself.

  • PDF