• Title/Summary/Keyword: tap water

Search Result 888, Processing Time 0.027 seconds

A survey on recognition about water fluoridation of the primary teachers at non-fluridated area in Jinhae (수돗물불소농도조정사업 비 혜택지역 진해시 초등학교 교사의 사업 인지도 조사연구)

  • Jang, Kyeung-Ae;Moon, Seon-Jeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.4
    • /
    • pp.509-519
    • /
    • 2007
  • The purpose of this study was to take inforamtion to increase support on water fluoridation primary school teachers in Jinhae. The survey was done by self-administration method to primary school teachers 88 at non-fluoridated area in Jinhae. The date was analysed using the SPSS 10.1 program. The results are as follows : The mean percentage of the respondents using the tap water and purified water for drinking was 51.1% and 33.3%, respectively. Recognition rate of water fluoridation was 64.8%, 33.3% of the respondents knew about water fluoridation from mass mesdia. 62.5% of the respondents agreed with water fluoridation. 76.1% of the respondents knew that the purpose of water fluoridation was the prevention of dental caries. 72.7% of the respondents agreed with continuous water fluoridation. 70.5% of the recognized about safety of water fluoridation. 72.7% of the respondents agreed with decision of professional group for the performance of water fluoridation. In order to secure residents' support for the continuation of the adjusted water fluoridation program and to reinforce the education for safety and economical efficiency for the residents through systemic education.

  • PDF

Corrosion control technique for pipeline system through injecting water stabilizer (수질안정화 약품 주입에 따른 상수도관 내부 부식제어 특성 연구)

  • Hwang, Byung-Gi;Woo, Dal-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.545-551
    • /
    • 2011
  • Recently, demands for generating high quality tap waters are increasing with high concern of water pollution and corrosion of water pipelines. For the reasons, developing water quality stabilization technique in water purification system is sought rather than replacing to a new pipelines. In this study, high-purity liquid lime($Ca(OH)_2$) was introduced for a water quality stabilization technique in water purification process and simulated water distribution system of pilot-scale size was applied to evaluate anti-corrosion control effect. The effect of anti-corrosion control was calculated in terms of LSI(Langelier Saturation Index) In conclusion, the result of pilot plant showed improvement of corrosiveness by liquid lime($Ca(OH)_2$) with reduction of released iron(Fe). Application of anti-corrosion control technique to the mild steel coupon and the copper coupon were effective by indicating 35.4, 44.5% of improvements. Besides, sample pipes which were treated with liquid lime had formated more thicker layer of corrosion product inside of pipes. As a result, the process of injecting water stabilizer can greatly contribute to the high quality of tap water.

Effect of Sampling and Analytical Methods on the Fibrous Materials from the Ground Water (시료 채취 조건 및 검사방법에 따른 지하수내 섬유상 물질 검출 양상에 관한 연구)

  • Kim, Ji-Yong;Kim, Jung Ran;Cheong, Hae-Kwan;Lim, Hyun-Sul;Paik, Nam-Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.209-222
    • /
    • 1997
  • Authors surveyed the ground water near the waste disposed from a fiberglass production factory to confirm the presence of glassfiber in the water and to determine the effect of sampling conditions and storage on the recovery of fibrous materials in the ground water. Sample was collected at every 4 hours for 48 hours consecutively. After finishing the 48 hours sample, water sampling was done from each tap after repeated turning on and off the water for 30 seconds at each time. Sample was collected in the two 1.5 liter polyethylene bottle after vigorously shaking the bottle with the same water several times with the flowing tap water. At each paired sample, one bottle was stored stand still at room temperature, and the other sample was filtered immediately after sampling. Water was filtered on the Mixed Cellulose Ester filter with negative pressure. Each sample was divided into upper and lower layer. The other bottle was stored at room temperature standstill for 7 days and filtered in the same fashion as the other pair of sample did. Each MCE filter was divided into 4 pieces and one piece was treated with acetone to make it transparent. Each prepared sample was observed by two researchers under the light and polarizing microscopy, scanning electron microscopy and energy dispersive X-ra microanalysis. Fibers were classified by the morphology and polarizing pattern under the polarizing microscope, and count was done. 1. There was a significant fluctuation in number of the fibers, but there was no specific demonstrable pattern. 2. Non-polarizing fibers frequently disappeared after 7 days's storage. But cluster of fibers were found at the wall of the same container by scratching technique. 3. Polarizing fibers were usually found in between the filter and the manicure pasted area. Possible explanations for this phenomenon will be that either these fibers are very light or have electronic polarity. Hence, these fibers are not able to be attached on the surface of slide glass. 4. Under the scanning electron microscopic examination, the fibers which are not refractive under the light microscopy were identified as glassfiber. Other fibers which is refractive under the polarizing microscopy were identified as magnesium silicate fibers. It is strongly suggested that development of standardized method of sample collection and measurement of fibrous material in the water is needed.

  • PDF

Construction of Tap Water Management System for Subset Area of Hamyang Gun Using GIS (GIS를 이용한 함양군 일부지역의 상수도 관리 시스템 구축)

  • 김재명;안기원;신석효;김상철
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.347-352
    • /
    • 2003
  • This study attempts to develop the management and control system of water pipe on the footing of database builded by the research on the pipe of water supply equipped over 48.809km within district of Hamyang-up by Hamyang-Gun, and to apply it to the work of self-governing body. And, since the structure and equipment of facilities of underground water supply pipe ate so complex, the maintenance and management of function of facilities are needed for long-term. This study has the purpose to build the database per self-governing body which can be connected with the future NGIS project, and to promote the efficiency of management and control of facilities and equipment.

  • PDF

Application of Reversed-Phase Solid Phase Extraction for the HPLC Analysis of Microcystins in Water (다량 시료중 마이크로시스틴의 농축 및 분석)

  • Kim, Myeong-Hee;Kim, Tae-Seung;Kim, Tae-Keun;Park, Sun Ku
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.399-402
    • /
    • 2000
  • To determine the concentrations of microcystins present in lake water or in tap water using high performance liquid chromatography, it is necessary to concentrate a large volume of water samples (about 20 L) into very small volume (0.1-0.3 mL). Concentration can be conveniently done when disc type solid phase extraction (SPE) apparatus is used. Using this apparatus we have investigated the recovery rates of three kinds of microcystins, RR, YR, LR. The recovery rates were relatively low and the reproducibilities were not good either. It is expected, however, that the appropriate selection of the disc conditioning and eluting solvents and reproducible reconcentration process after SPE will improve both the recovery rates and the reproducibilities.

  • PDF

Relationships between levels of heterotrophic plate count bacteria and endotoxin in point-of-use water treatment systems

  • Moon, Kyong-Whan;Kim, Young-Whan;Shon, Jong-Ryeul
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.132-135
    • /
    • 2003
  • Endotoxin concentrations were measured from 69 point-of-use(POU) water treatment system(WTS) by using Limulus amebocyte lysate(LAL) assay, and the results were compared to heterotrophic bacterial data. Endotoxin concentrations in all POU WTS water samples and tap waters varied within the range 0.8-79.1EU mL$\^$-1/ and 0.1-3.4EU mL$\^$-1/, respectively, The correlations between endotoxin concentration and HPC bacteria from the water samples showed not significant(r=0.18).

  • PDF

The analysis of heavy metal total contents In milt of Han river (한강유역 저니층의 중금속 함량 전분석)

  • 정일현;김세진
    • Journal of environmental and Sanitary engineering
    • /
    • v.9 no.2
    • /
    • pp.63-71
    • /
    • 1994
  • An analytic and comparative study on the level of concentration on heavy metals in silt of Han- River was described. The Paldang lake supplies tap water resources for the 20 million residents in the metropolitan zone. It is composed that three steps for water works by the water volume in all 35,072 thousand tons : the first section is 7,251 thousand tons, the second is 15,980 thousand tons and the third is 11,841 thousand tons. However, recently it has becoming a serious social issue for water contamination on Paldang by heavy metals due to gathering of silt. It has concentrated on analysis and comparison study on the level of heavy metals between contamination- estimated zone and the other zones. After all, Concentration on heavy metals of expected none pollute's zone and expected pollute's zone indicate almost similar results. In the end, heavy metals within silt of Han- River consider not to effect on pollution but quantity of natural condition.

  • PDF

Contamination of Shellfish with Vibrio vulnificus the Present Situation and Countermeasures (어패류의 비브리오패혈증 균 오염과 그 대책)

  • 김영만
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.2
    • /
    • pp.13-21
    • /
    • 1993
  • Vibrio septicemia,, resulting in high mortality, has been caused by Vibrio vulnificus. Ingestion of marine products or contact with sea water contaminated with Vibrio vulnificus can cause septicemia. Vibrio vulnificus has been detected world wide and west sea area of Korea, Kum river estuary in particular, showed high detection rate. Higher detection rate of Vibrio vulnificus were reported in the bottom deposit with low depth of water, low salinity, and high COD. Man with the liver disease can easily come down with Vibrio septicemia and the main source is the sliced raw fish dish. The preventive measure for this disease is to wash raw fish material thoroughly with tap water and handle in sanitary conditions. Washing with sea water is strictly prohibited . It may be necessary to forbid the small-scale businessmen from selling the sliced ray fish dish in the vicinity of seashore. Man with the liver disease of diabetes should not swim or consume the raw fish dish in the contaminated area during summer.

  • PDF

Mercury Ion Removal Using a Packed-Bed Column with Granular Aminated Chitosan

  • JEON, CHOONC
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.3
    • /
    • pp.497-501
    • /
    • 2005
  • This study deals with the removal of mercury species using a packed-bed column with spherical aminated chitosan material. These adsorbents revealed a high adsorption capacity for mercury species. Experiments with feed solutions of 10 ppm Hg dissolved in distilled water showed an excellent removal with a sharp increase of the filter effluent concentration after a total throughput of 900 bed volumes of feed water. Up to $95\%$ desorption was reached by using 3 bed volumes of 0.01 N EDTA solution. EDTA could be recovered by means of sulfuric acid with about $75\%$ efficiency. Almost the same results were obtained in repeated sorption and desorption experiments at identical conditions. The experiments demonstrated that the sorbents possessed practically no sorption capacity for alkaline earth ions ($Ca^{2+}\;and\;Mg^{2+}$). Their influence on the sorption of mercury was negligible. In experiments with spiked tap water of the Karlsruhe Research Centre and a feed mercury concentration of 0.01 mg/l, the breakthrough of Hg was observed only after a total throughput of about 6,000 bed volumes of feed water.

Determination of Lead in Different Samples by Atomic Absorption Spectrometry after Preconcentration with Dithizone Immobilized on Surfactant-Coated Alumina

  • Dadfarnia, S.;Haji Shabani, A.M.;Dehgan Shirie, H.
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.4
    • /
    • pp.545-549
    • /
    • 2002
  • A simple and rapid technique for the separation and preconcentration of lead in water and biological samples has been devised. Preconcentrationis based on the depositionof analyte onto a column packed with dithizone immobilized on sodium dodecyl sulfate coated alumina at pH $\geq$ 3. The trapped lead is eluted with 5 mL of 4 M nitric acid and determined by flame atomic absorption spectroscopy. A sample of 1 L, results in a preconcentration factor of 200 and the precision at 20${\mu}g$ $L^{-1}$ is 1.3%(n=8). The procedure is applied to tap water, well water, river water, vegetable extract and milk samples, and accuracy is assessed through recovery experiments and by independent analysis by furnace atomic absorption.