시료 채취 조건 및 검사방법에 따른 지하수내 섬유상 물질 검출 양상에 관한 연구

Effect of Sampling and Analytical Methods on the Fibrous Materials from the Ground Water

  • 김지용 (동국대학교 의과대학 예방의학교실) ;
  • 김정란 (동국대학교 의과대학 병리학교실) ;
  • 정해관 (동국대학교 의과대학 예방의학교실) ;
  • 임현술 (동국대학교 의과대학 예방의학교실) ;
  • 백남원 (서울대학교 보건대학원)
  • Kim, Ji-Yong (Department of Preventive Medicine, College of Medicine, Dongguk University) ;
  • Kim, Jung Ran (Department of Pathology, College of Medicine, Dongguk University) ;
  • Cheong, Hae-Kwan (Department of Preventive Medicine, College of Medicine, Dongguk University) ;
  • Lim, Hyun-Sul (Department of Preventive Medicine, College of Medicine, Dongguk University) ;
  • Paik, Nam-Won (School of Public Health, Seoul National University)
  • 발행 : 1997.11.13

초록

Authors surveyed the ground water near the waste disposed from a fiberglass production factory to confirm the presence of glassfiber in the water and to determine the effect of sampling conditions and storage on the recovery of fibrous materials in the ground water. Sample was collected at every 4 hours for 48 hours consecutively. After finishing the 48 hours sample, water sampling was done from each tap after repeated turning on and off the water for 30 seconds at each time. Sample was collected in the two 1.5 liter polyethylene bottle after vigorously shaking the bottle with the same water several times with the flowing tap water. At each paired sample, one bottle was stored stand still at room temperature, and the other sample was filtered immediately after sampling. Water was filtered on the Mixed Cellulose Ester filter with negative pressure. Each sample was divided into upper and lower layer. The other bottle was stored at room temperature standstill for 7 days and filtered in the same fashion as the other pair of sample did. Each MCE filter was divided into 4 pieces and one piece was treated with acetone to make it transparent. Each prepared sample was observed by two researchers under the light and polarizing microscopy, scanning electron microscopy and energy dispersive X-ra microanalysis. Fibers were classified by the morphology and polarizing pattern under the polarizing microscope, and count was done. 1. There was a significant fluctuation in number of the fibers, but there was no specific demonstrable pattern. 2. Non-polarizing fibers frequently disappeared after 7 days's storage. But cluster of fibers were found at the wall of the same container by scratching technique. 3. Polarizing fibers were usually found in between the filter and the manicure pasted area. Possible explanations for this phenomenon will be that either these fibers are very light or have electronic polarity. Hence, these fibers are not able to be attached on the surface of slide glass. 4. Under the scanning electron microscopic examination, the fibers which are not refractive under the light microscopy were identified as glassfiber. Other fibers which is refractive under the polarizing microscopy were identified as magnesium silicate fibers. It is strongly suggested that development of standardized method of sample collection and measurement of fibrous material in the water is needed.

키워드