A Study on the High Strength of porcelain insulators for transmission line (송전용 자기재 현수애자의 고강도 특성 연구)

  • Cho, H.G.;Han, S.W.;Park, K.H.;Choi, Y.K.;Lee, D.I.;Choi, I.H.;Kim, T.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.85-88
    • /
    • 2003
  • In this study, porcelain insulator samples which have a different alumina composition were manufactured in order to test electrical and mechanical properties and make an analysis of the propagation phenomena of micro cracks on porcelain body. From XRD quantitative analysis the crystalline phases were different with alumina composition, sample C and D which have about 17wt% Corundum phase without the Cristobalite phase shows better electrical and mechanical properties than sample A and 8 which have the Cristobalite phase. In dielectrics test on porcelain samples with below 17wt% alumina composition, it was found that the amount of glass phase$(SiO_2)$have an main effect to decrease the dielectric loss$(tan{\delta})$, and the dielectric breakdown voltage of aluminous porcelain insulators was largely affected by its relative density. As a micro cracks analysis, HRS were measured, then the intensity of HRS increased with the amount of alumina composition. On the other hand, the propagation behaviors of cracks was fairly influenced by the distribution of pores.

  • PDF

Judgement Criterion of Insulation Deterioration in 4.16kV and 6.6kV Motor Stator Windings (4.16kV 및 6.6kV 전동기 고정자 권선의 절연열화 판정기준)

  • Kim, Hee-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.788-794
    • /
    • 2009
  • To assess the condition of stator insulation, nondestructive tests were performed on twenty five coil groups and twenty six motors. The stator windings has nominal ratings of 6.6kV and are classified into five coil groups ;one group with healthy insulation and four groups with four different types of artificial defects. After completing nondestructive tests, the AC voltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No.1, No.2 and No.6 of 6.6kV motors failed near rated voltage of 14kV, 8.7kV and 14kV, respectively. The breakdown voltage of three motors was lower that expected for good quality coils(14.2kV) in 6.6kV motors. No.3 and No.6 of 4.16kV motors failed near rated voltage of 5.6kV and 4.2kV, respectively. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor(tan${\delta}$) and partial discharge magnitude.

Reference Model Updating of Considering Disturbance Characteristics for Fault Diagnosis of Large-scale DC Bus Capacitors (대용량 직류버스 커패시터의 고장진단을 위한 외란특성 반영의 레퍼런스 모델 개선)

  • Lee, Tae-Bong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.213-218
    • /
    • 2017
  • The DC electrolytic capacitor for DC-link of power converter is widely used in various power electronic circuits and system application. Its functions include, DC Bus voltage stabilization, conduction of ripple current due to switching events, voltage smoothing, etc. Unfortunately, DC electrolytic capacitors are some of the weakest components in power electronics converters. Many papers have proposed different algorithms or diagnosis method to determinate the ESR and tan ${\delta}$ capacitance C for fault alarm system of the electrolytic capacitor. However, both ESR vary with frequency and temperature. Accurate knowledge of both parameters at the capacitors operating conditions is essential to achieve the best reference data of fault alarm. According to parameter analysis, the capacitance increases with temperature and the initial ESR decreases. Higher frequencies make the reference ESR with the initial ESRo value to decrease. Analysis results show that the proposed DC Bus electrolytic capacitor reference ESR model setting technique can be applied to advanced reference signal of capacitor diagnosis systems successfully.

A Study on the Dielectric Properties and Mechanical characteristics of Composit Materials due to the High-Temper, and-Humidity (고온.다습하(高溫.多濕下)에서의 복합재료(複合材料)의 수요특성(特性) 및 기계적특성(機械的特性)에 관한 연구(硏究))

  • Lee, Jong-Ho;Lee, Kyu-Chul;Hwang, Yeong-Han;Kim, Hea-Dae;Lee, Tae-Sik;Park, Hong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.750-752
    • /
    • 1992
  • The paper presents the effects of environment on glass-cloth/epoxy composites exposed to humid air were investigated. Tests were performed at temperature 40$^{\circ}C$ and 70$^{\circ}C$ with the materials exposed to humid air at 76% and 90% relative humidity. This investigation surveyed include (a) the moisture absorption and desorption characteristics of single and multi layered composites exposed to steady and to transient ambients, and (b) the resulting changes in tensile strength, dielectric strength, tan $\delta$ and $\varepsilon_{\tau}$ and the effects of environment on these parameters were assessed.

  • PDF

Electrical and Thermo-mechanical Properties of DGEBA Cycloaliphatic Diamine Nano PA and SiO2 Composites

  • Trnka, Pavel;Mentlik, Vaclav;Harvanek, Lukas;Hornak, Jaroslav;Matejka, Libor
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2425-2433
    • /
    • 2018
  • This study investigates a new organic based material and its dielectric and mechanical properties. It is a comprehensive nanocomposite comprising a combination of various types of nanofillers with hydrophobic silica nanoparticles (AEROSIL R 974) as a matrix modifier and a polyamide nano nonwoven textile, Ultramid-Polyamide 6, pulped in the electrostatic field as a dielectric barrier. The polymer matrix is an epoxy network based on diglycidyl ether of bisphenol A (DGEBA) and cycloaliphatic diamine (Laromine C260). The designed nanocomposite material is an alternative to the conventional three-component composites containing fiberglass and mica with properties that exceed current electroinsulating systems (volume resistivity on the order of $10^{16}{\Omega}{\cdot}m$, dissipation factor tan ${\delta}=4.7{\cdot}10^{-3}$, dielectric strength 39 kV/mm).

MECHANICAL AND ELECTRICAL PROPERTIES OF STYRENE-BUTADIENE-STYRENE/ ALUMINIUM COMPOSITES

  • Renukappa, N.M.;Siddaramaiah, Siddaramaiah;Sudhaker Samuel, R.D.;Jeevananda, T.;Kim, Nam-Hoon;Lee, Joong-Hee
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.142-147
    • /
    • 2007
  • A series of styrene-butadiene-styrene/aluminium (SBR/Al) composites have been compounded with different weight ratios of Al. The prepared SBR-Al systems have been characterized for different mechanical properties such as tensile strength, tensile modulus and surface hardness have improved with the increase in content of Al in SBR matrix. This may is because of the increase in polymer-filler interaction. The electrical properties such as volume conductivity, surface resistivity, dielectric constant, dissipation factor (tan delta), and break down voltage of SBR/Al composites have been measured with reference to volume fraction $(V_{f}),$ frequency and temperature. The resistance of the SBR-Al composites is found to be ohmic. The voltage-current (V-I) characteristics for SBR-Al also exhibit a linear relationship indicating the ohmic behavior.

  • PDF

Guideline for Field Partial Discharge measurement of Underground Transmission Level XLPE Cable (지중송전 XLPE케이블 활선상태 PD 측정기술 향상을 위한 가이드라인 제시)

  • Park, Jin-Woo;Choi, Kyung-Kyu;Lee, Joen-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.141-142
    • /
    • 2008
  • 국내 지중송전선로는 주로 XLPE케이블과 OF케이블로 구성된다. 1971년 154kV급 OF 케이블이 최초로 한전에 의해 상용운전에 들어간 후 XLPE 케이블 지중선로가 1983년부터 병용운전 되고 있으며 OF케이블의 경우 절연유의 사용으로 인한 화재의 위험과 환경오염 문제 등으로 인하여 점진적으로 XLPE케이블로 대체되는 추세에 있다. 하지만 내전압 시험, 절연저항이나 누설전류 측정, $tan{\delta}$ 측정 등으로 진단이 가능했던 OF케이블과는 달리 XLPE케이블의 경우 종래의 시험을 통한 진단은 한계가 있고 부분방전을 통한 진단이 가장 효율적인 진단방법으로 제시되어 국내외 XLPE케이블의 진단을 위해 운영되고 있으며 보다 정확한 PD측정을 위한 연구가 계속 진행되고 있다. 지난 10년여간의 국내외 연구결과 XLPE케이블에 대한 PD 측정기술의 정확성은 상당히 향상되었고 그 결과물로서 수많은 폭정 장비와 기법이 개발되어 오늘날 널리 보급되고 있다. 하지만 여전히 측정된 Data에 대한 해석은 일부 전문가들에게 조차 복잡하고 어려운 일로 남아 있다. 자칫 그릇된 해석은 향후 큰 사고로 이어질 수 있으므로 선로 운영자의 입장에서는 측정결과의 신뢰성에 민감할 수밖에 없다.

  • PDF

Effect of Acetylated Rice Starch on Rheological Properties of Surimi Sol and Gel

  • Jung, Young-Hwa;Kim, Won-Woo;Yoo, Byoung-Seung
    • Food Science and Biotechnology
    • /
    • v.16 no.5
    • /
    • pp.817-821
    • /
    • 2007
  • The effect of acetylated rice (AR) starch at different concentrations (0, 4, 6, and 8%) on rheological properties of surimi sols and gels was studied. Dynamic frequency sweeps of surimi-AR starch sols at $10^{\circ}C$ showed that the magnitudes of storage moduli (G') decreased with an increase in starch concentration while those of tan ${\delta}$ increased, indicating that the effect of AR starch on the viscoelastic properties of surimi sols depended on starch concentration. In general, the G' thermograms of surimi sols showed the similar sol-gel transition pattern and they were also influenced by the addition of AR starch. The presence of AR starch in the surimi gel system reduced the gel strength and expressible moisture content (EMC). Surimi-AR starch gels showed better freeze-thaw stability compared to the control (0% starch concentration). The effect of AR starch on the rheological properties of surimi sols and gels appeared to be related to the swelling ability of starch granules in the presence of limited water available for starch.

Characteristics of PAN-PZI Ceramics with $BaCO_3$Addition ($BaCO_3$ 첨가량에 따른 PAN-PZT계 세라믹스의 특성)

  • 박타리;이동균;최지원;김현재;윤석진;조봉희;고태국
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.981-984
    • /
    • 2001
  • The piezoelectric properties of 0.05pb(A $l_{0.5}$N $b_{0.5}$) $O_3$-0.95Pb(Z $r_{0.52}$ $Ti_{0.48}$) $O_3$+0.7wt%N $b_2$ $O_{5}$ +0.5wt%Mn $O_2$ceramics with the additives of BaC $O_3$were investigated. For the additions of BaC $O_3$, the dielectric constant ($\varepsilon$$^{T}$ $_{33}$ ), the piezoelectric constant ( $d_{33}$ ), the electromechanical coupling factor ( $k_{p}$ ), and . the mechanical quality factor ( $Q_{m}$ ) were increased, but dielectric loss (tan$\delta$) was decreased. The highest piezoelectric properties and dielectric properties were observed at the sintered temperature of 120$0^{\circ}C$ and 0.4 wt% of BaC $O_3$, and the properties of $d_{33}$ , $k_{p}$ , and $Q_{m}$ were 339(x10$^{-12}$ C/N), 59% and 1754, respectively.vely.y.y.

  • PDF

The Preparation and Characterization of BLT Thin Films by MOD Process (MOD법을 이용한 BLT박막의 제초 및 특성에 관한 연구)

  • 이진한;장건익
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.186.1-189
    • /
    • 2001
  • Ferroelectric $Bi_{4-x}$La$_{x}$Ti$_3$O$_{12}$ (BLT)thin films with various compositions(x=0.65, 0.70, 0.75) were prepared on Pt//Ti/SiO$_2$/Si(100) substrate by metal-organic deposition. The electrical and structural characteristics of BLT thin films were investigated to develop ferroelectric thin films for capacitor layers of FRAM. After spin coating, thin films were annealed at $650^{\circ}C$ for 1hour in oxygen atomosphere. Scanning electron micrographs showed uniform surfaces composed of rod-like grains. The $Bi_{4-x}$La$_{x}$Ti$_3$O$_{12}$ (x=0.70) thin film capacitors with a Pt top electrode showed better ferroelectric properties than other films. At the applied voltage of 5V, the dielectric constant($\varepsilon$$_{r}$), dissipation factor(tan$\delta$),remanent polarization(2Pr), and coercive field(2Ec) of the $Bi_{4-x}$La$_{x}$Ti$_3$O$_{12}$ (x=0.70)thin films were about 272.54, 0.059, 32.4 $\mu$C/cm$^2$, 2Ec=119.9kV/cm. Also the capacitor did not show any significant fatigue up to 4.8$\times$10$^{10}$ read/write switching cycles.hing cycles.s.

  • PDF