• Title/Summary/Keyword: tan ${\delta}$

Search Result 521, Processing Time 0.032 seconds

Dielectric Properties on Gamma Ray Irradiated Low Density Polyethylene (방사선조사에 따른 저밀도 폴리에틸렌의 유전특성)

  • Kim, Ki-Yup;Ryu, Boo-Hyung;Kang, Seong-Hwa;Lee, Chung;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.11
    • /
    • pp.938-942
    • /
    • 2000
  • Radiation effects on dielectric properties of low density polyethylene(LDPE) were investigated using the various measurements of FT-IR, gel content and elongation at break. FT-IR spectra showed that polar groups were comprised in LDPE due to radiation treatment. It was also confirmed that the formation of polar groups on LDPE caused the increased dielectric properties such as permittivity and tan $\delta$. However, in this study, any evidence of decreasing permittivity was not found although the morphological change of LDPE could be identified from the increasing gel content and the decreasing elongation.

  • PDF

Experimental Investigation on Dielectric and Thermal Characteristics of Nanosized Alumina Filler Added Polyimide Enamel

  • Sugumaran, C. Pugazhendhi
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.978-983
    • /
    • 2014
  • The polymer nano composite possess good priority recently for engineering applications. Especially the electrical insulating materials attract the high performance of nano composites. In this work the ballmill synthesiation process of nano sized Alumina ($Al_2O_3$), the preparation of new nano composite material with an content of enamel and synthesized Alumina as 1wt%, 3wt% and 5wt%. Experimental investigation has been carried out for the prepared nano composites materials with respect to dielectric parameter measurements such as dielectric loss (tan ${\delta}$), dielectric constant (${\varepsilon}$), dielectric strength under various temperature. The partial discharge level also measured for all the samples and the PD inception voltage is also observed and compared. Weight loss of the material has been analyzed through TGA. It has been experimentally proved that 3wt% of Alumina nano filler added enamel has significant improvement in the dielectric and thermal properties.

A study on the characteristics of deterioration in 6.6kV CV cable (6.6kV CV케이블의 경년열화 특성연구)

  • Kim, K.H.;Sun, J.H.;Kim, Y.B.;Cho, Y.O.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.636-639
    • /
    • 1993
  • This paper is discribed the results of insulation characteristic tests that are DC leakage current, test, tan${\delta}$ test, AC breakdown test and observation of tree in the used 6.6kV CV cables. In the correlation of these tests, the tan${\delta}$ test stands for the main deterioration factor of cable insulation.

  • PDF

A study on dielectric characteristics of gamma irradiated LDPE (방사선 조사에 따른 저밀도 폴리에틸렌의 유전특성에 관한 연구)

  • kim, Ki-Yup;Lee, Chung;Lim, Kee-Joe;Ryu, Boo-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.169-172
    • /
    • 2000
  • In this paper, we evaluated the mechanical and dielectric properties of LDPE depend on $Co_{60}$${\gamma}$-irradiation doses. The chemical analyses for FT-IR, gel content, the mechanical properties for elongation at break and the dielectric parameters for permittivity, tan$\delta$ were discussed as a function of irradiation doses. Test result presented that elongation at break of irradiated LDPE was inversely proportional to gel content. For dielectric analyses, permittivity showed a salient characteristic for various irradiation doses, it was related to polar groups caused radiation degradation and tan$\delta$ of irradiated LDPE increased with irradiation doses.

  • PDF

Dielectric Characteristics of HTS Cable (고온초전도 케이블의 유전 특성)

  • Kwag, Dong-Soon;Kim, Hae-Jong;Cho, Jeon-Wook;Seong, Ki-Chul;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.64-68
    • /
    • 2002
  • According to the increasing power demand for the future construction of many underground cables will be required. However, construction of new ducts for power cables will be more difficult. Therefore, research work for realizing the high temperature superconducting(HTS) cable has advanced, where the development of electrical insulating system at cryogenic temperature is one of the major researches. For an electrical insulation design of HTS cable, it is important to understand not only breakdown but also partial discharge and dielectric loss($tan{\delta}$) in liquid nitrogen/paper composite insulation system. In this paper, we investigated breakdown characteristics in liquid nitrogen/paper composite insulation system for the application to HTS cable. And, we studied the breakdown characteristics of the multi-layer and butt gap of the insulation papers in liquid nitrogen. Also, we measured dielectric loss($tan{\delta}$) of the mini-model Cable made of TERLAM IPP.

  • PDF

Dynamic Rheological Comparison of Selected Gum Solutions

  • Choi, Su-Jin;Chu, So-Young;Yoo, Byoung-Seung
    • Food Science and Biotechnology
    • /
    • v.15 no.3
    • /
    • pp.474-477
    • /
    • 2006
  • Dynamic rheological properties of commercial 0.8, 1.0, and 1.2% gums [carboxylmethylcellulose (CMC), guar gum, hydroxypropylmethylcellulose (HPMC), tara gum, and xanthan gum], which can be dissolved in cold water, were investigated by small-deformation oscillatory measurements. Magnitudes of storage (G') and loss (G") moduli increased with increasing concentration of gum solutions except for xanthan gum. Guar gum exhibited greatest G' and G" values among all gums except for G' value at 0.8% concentration. Slopes of G' and G" decreased with increasing concentration of gum solutions except for xanthan gum. Tan ${\delta}$ (G"/G') values decreased with increasing concentration of gum solutions except for xanthan gum. Tan ${\delta}$ values of xanthan gum solutions were much lower than those of other gum solutions, indicating that xanthan gum solutions were predominantly more elastic than viscous.

Electron Beam Modification of Dual Phase Filler: Surface Characteristics and its Influence on the Properties of Styrene-Butadiene Rubber Vulcanizates

  • Shanmugharaj A. M.
    • Rubber Technology
    • /
    • v.5 no.2
    • /
    • pp.94-103
    • /
    • 2004
  • The present work describes modification of dual phase filler by electron beam irradiation in presence of multifunctional acrylates like trimethylol propane triacrylate (TMPTA) or silane coupling agent like bis (3-triethoxysilylpropyltetrasulphide) and in-fluence of the modified fillers on the physical properties of styrene-butadiene rubber (SBR) vulcanizates. Modulus at 300 % elongation increases whereas the tensile strength decreases with increase in radiation dose for the dual phase filler loaded styrene-butadiene rubber vulcanizates (SBR). However, modulus and tensile strength significantly increase, which is more, pronounced at higher filler loadings for TMPTA modified dual phase filler loaded SBR. These changes in properties are explained by the equilibrium swelling data and Kraus plot interpreting the polymer-filler interaction. Electron beam modification of the filler results in a reduction of tan ${\delta}$ at $70^{\circ}C$, a parameter for rolling resistance and increase in tan ${\delta}$ at $0^{\circ}C$, a parameter for wet skid resistance of the SBR vulcanizates. Finally, the influence of modified fillers on the properties like abrasion resistance, tear strength and fatigue failure and the improvement in the properties have been explained in terms of polymer-filler interaction.

  • PDF

Frequency Characteristics of Anodic Oxide Films: Effects of Anodization Valtage

  • Lee, Dong-Nyung;Yoon, Young-Ku
    • Nuclear Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.14-22
    • /
    • 1974
  • Effects of anodization voltage on frequency characteristics of anodic oxide films on tantalum were analyzed based on the following impedance equatious : (equation omitted) Here $R_{f}$, $C_{f}$ and tan $\delta$$_{f}$ are equivalent series resistance in ohm, equivalent Belies capacitance in farad and dielectric loss, of anodic oxide films respectively Parameters P, $\tau$$_{ο}$, $\tau$$_{\omega}$, and Co are defined as follows: P=(d-w)/w, $\tau$$_{ο}$=$textsc{k}$$\rho$$_{ο}$, $\tau$$_{\omega}$=$textsc{k}$$\rho$$_{\omega}$, $C_{ο}$=$textsc{k}$A/d where d is the thickness of oxide film, $\omega$ is the diffusion layer thickness. $\rho$$_{ο}$ is the resistivity of oxide film at the interface of metal and the oxide, $\rho$$_{\omega}$ is the resistivity of oxide film at intrinsic region and A is the area of the film and $textsc{k}$=0.0885$\times$10$^{-12}$ $\times$dielectric constant, (in farad/cm). It was shown that dielectric loss and frequency dependence of equivalent series capacitance decrease as anodization voltage increases. This is a consequence of the fact that the thickness of diffusion layer increases a little with increasing anodization voltage whereas the total oxide thickness is proportional to the anodization voltage. The ngative deviation of measured values from tile relation, tan $\delta$$_{f}$=0.682 $\Delta$ $C_{f}$, was also discussed based on the Impedance equations given above. Here $\Delta$ $C_{f}$ is the change in capacitance between 0.1 and 1 KHZ.KHZ.Z.

  • PDF

Clamping Voltage Characteristics and Accelerated Aging Behavior of CoCrTb-doped Zn/Pr-based Varistors with Sintering Temperature

  • Nahm, Ghoon-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.4
    • /
    • pp.125-130
    • /
    • 2009
  • The clamping voltage characteristics and accelerated aging behavior of CoCrTb-doped Zn/Pr-based varistors were investigated for different sintering temperatures. The best clamping voltage characteristics were obtained for the varistors sintered at $1330^{\circ}C$, with a clamping voltage ratio (K) of 1.63 at a surge current of 5 A and 1.75 at a surge current of 10 A. The varistors sintered at $1330^{\circ}C$ exhibited the highest stability, with -0.1% in $%{\Delta}E_{1\;mA}$, -0.2% in $%{\Delta}{\alpha}$, and +15.5% in $%{\Delta}J_L$ for E-J characteristics under a stress state of 0.90 $E_{1\;mA/120^{\circ}C$ /24 h. Furthermore, it exhibited $%{\Delta}{\varepsilon}_{APP}$' of -0.7% and $%{\Delta}tan{\delta}$ of +5.7% for dielectric characteristics under the same stress state.

Ductile Fracture in Axisymmetric Extrusion Process (축대칭 전방 압출 공정에서의 연성파괴)

  • 최석우;이용신;오흥국
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1996.10a
    • /
    • pp.29-37
    • /
    • 1996
  • A ductile fracture criterion, which has already proposed, namely, ($\Delta$1/1o)f at $\Delta$$\sigma$ m=(($\Delta$1/1o)f+(-1/tan$\theta$)$\Delta$$\sigma$m(where ($\Delta$1/1o)f is fracture elongation, $\Delta$$\sigma$m is mean stress variation) was made use of to study the working limit in axisymmetric extrusion. The present investigation is concerned with the application of theory on flow and fracture to the prediction of workability of materials in axisymmetric bar extrusion, with special reference to central bursting. The influenced of die geometry and manufacturing conditions on the central bursting are predicted.

  • PDF