• 제목/요약/키워드: tMRI

검색결과 1,247건 처리시간 0.03초

Comparative Evaluation between 1.5T vs 3.0T MRI in Brain Metastasis According to its Size

  • 정우석;정태섭;허진;이재훈
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.22-22
    • /
    • 2003
  • The purpose of this study was to compare the detection rate of brain metastasis according to size of nodule between 1.5T and 3.0T MRI 대상 및 방법: We reviewed 44 patients with primary tumors and clinical symptoms suggesting brain metastasis. After administration of double dose gadolinium-DTPA, MR imaging was performed with 3D SPGR sequence by 3.0T MRI and then with T1 SE sequence by 1.5T MRI. Consequently, comparison was done in 1.5T T1 SE sequence and 3.0T 3D SPGR sequence. With use of the signal intensity (SI) measurements in the metastatic nodules and adjacent tissue, metastatic nodule-to-adjacent tissue SI ratio were calculated. In each patient, the number of metastatic lesions detected in 1.5T and 3.0T, and their size were assessed qualitatively by three blinded readers.

  • PDF

간문맥 묘출을 위한 최적의 영상진단 장치에 관한 연구: MRI, CT 중심으로 (A Study on Applied to Optimal Diagnostic Device in Portal Vein Visualization: Focused on MRI and CT)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.217-225
    • /
    • 2019
  • 본 연구의 목적은 CT와 3.0T MRI 기기를 이용하여 간문맥을 묘출하는데 있어서 신호대 잡음비와 대조 도대 잡음비의 정량적인 수치를 비교 분석 하여 최적의 영상장치를 알아보고자 하였다. 2018년 2월부터 2018년 4월까지 C대학교병원에서 CT와 3.0T MRI 간 검사를 시행한 20명의 환자를 대상으로 의료영상저장전송시스템로 전송된 데이터를 무작위로 선정하였다. 정량적 평가를 위하여 간문맥의 4부위(주문맥, 우문맥, 좌문맥, 중간문맥)의 동일한 관심영역을 선정 후 신호평균값과 표준편차를 측정하여 SNR과 CNR값을 평가하였다. 평가결과 SNR은 CT에서 우문맥 : $9.18{\pm}0.72$, 좌문맥 : $9.41{\pm}0.84$, 중간문맥 : $9.54{\pm}0.59$, 주문맥 : $9.55{\pm}0.75$이고 3.0T MRI에서 우문맥 : $22.29{\pm}2.03$, 좌문맥 : $25.89{\pm}3.19$, 중간문맥 : $24.39{\pm}2.87$, 주문맥 : $26.64{\pm}2.30$으로 측정되었다(p<0.05). CNR은 CT에서 우문맥 : $3.75{\pm}0.66$, 좌문맥 : $3.44{\pm}0.65$, 중간문맥 : $3.71{\pm}0.39$, 주문맥 : $3.79{\pm}0.68$이고 3.0T MRI에서 우문맥 : $9.49{\pm}0.65$, 좌문맥 : $11.00{\pm}01.90$, 중간문맥 : $12.70{\pm}1.75$, 주문맥 : $10.01{\pm}0.98$으로 3.0T MRI가 CT보다 높은 수치로 측정되었다(p<0.05). 결론적으로 4부위의 간문맥을 분석한 결과 SNR과 CNR값이 3.0T MRI에서 높은 것으로 나타났다. 따라서 CT와 3.0T MRI에서 간문맥을 묘출하기 위한 최적의 영상장비는 비전리 방사선을 이용하는 3.0T MRI가 우위로 나타났다.

Correlation between magnetic resonance imaging and cone-beam computed tomography for maxillary sinus graft assessment

  • Laurino, Fernando Antonio Reis;Choi, Isabela Goulart Gil;Kim, Jun Ho;Gialain, Ivan Onone;Ferraco, Renato;Haetinger, Rainer Guilherme;Pinhata-Baptista, Otavio Henrique;Abdala-Junior, Reinaldo;Costa, Claudio;Cortes, Arthur Rodriguez Gonzalez
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.93-98
    • /
    • 2020
  • Purpose: Little is known regarding the accuracy of clinical magnetic resonance imaging (MRI) protocols with acceptable scan times in sinus graft assessment. The aim of this study was to evaluate the correlations between MRI and cone-beam computed tomographic (CBCT) measurements of maxillary sinus grafts using 2 different clinical MRI imaging protocols. Materials and Methods: A total of 15 patients who underwent unilateral sinus lift surgery with biphasic calcium phosphate were included in this study. CBCT, T1-weighted MRI, and T2-weighted MRI scans were taken 6 months after sinus lift surgery. Linear measurements of the maximum height and buccolingual width in coronal images, as well as the maximum anteroposterior depth in sagittal images, were performed by 2 trained observers using CBCT and MRI Digital Imaging and Communication in Medicine files. Micro-computed tomography (micro-CT) was also performed to confirm the presence of bone tissue in the grafted area. Correlations between MRI and CBCT measurements were assessed with the Pearson test. Results: Significant correlations between CBCT and MRI were found for sinus graft height (T1-weighted, r=0.711 and P<0.05; T2-weighted, r=0.713 and P<0.05), buccolingual width (T1-weighted, r=0.892 and P<0.05; T2-weighted, r=0.956 and P<0.05), and anteroposterior depth (T1-weighted, r=0.731 and P<0.05; T2-weighted, r=0.873 and P<0.05). The presence of bone tissue in the grafted areas was confirmed via micro-CT. Conclusion: Both MRI pulse sequences tested can be used for sinus graft measurements, as strong correlations with CBCT were found. However, correlations between T2-weighted MRI and CBCT were slightly higher than those between T1-weighted MRI and CBCT.

3.0T 자기공명영상을 이용한 잡음전력스펙트럼 특성 평가 (Evaluation of Noise Power Spectrum Characteristics by Using Magnetic Resonance Imaging 3.0T)

  • 민정환;정회원;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.31-37
    • /
    • 2021
  • This study aim of quantitative assessment of Noise Power Spectrum(NPS) and image characteristics of by acquired the optimal image for noise characteristics and quality assurance by using magnetic resonance imaging(MRI). MRI device was (MAGNETOM Vida 3.0T MRI; Siemense healthcare system; Germany) used and the head/neck shim MR receive coil were 20 channels coil and a diameter 200 mm hemisphere phantom. Frequency signal could be acquired the K-space trajectory image and white image for NPS. The T2 image highest quantitatively value for NPS finding of showed the best value of 0.026 based on the T2 frequency of 1.0 mm-1. The NPS acquired of showed that the T1 CE turbo image was 0.077, the T1 CE Conca2 turbo image was 0.056, T1 turbo image was 0.061, and the T1 Conca2 turbo image was 0.066. The assessment of NPS image characteristics of this study were to that could be used efficiently of the MRI and to present the quantitative evaluation methods and image noise characteristics of 3.0T MRI.

MRI T2강조영상에서 측두하악관절 원판 후 조직의 상대적 신호 강도에 대한 연구 (THE RELATIVE SIGNAL INTENSITY OF RETRODISCAL TISSUE IN TMJ USING A T2-WEIGHTED MRI)

  • 예영근;이상화;윤현중
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권5호
    • /
    • pp.457-462
    • /
    • 2005
  • The aim of this study is to evaluate the relative signal intensity of TMJ retrodiscal tissue in T2-weighted MRI as diagnostic marker of temporomandibular disorder(TMD). 58 temporomandibular joints from 29 TMD patients (14 men & 15 women) were evaluated. The relative signal intensity of retrodiscal tissue in T2-weighted MRI was referenced to brain gray matter same size of the region of interest(ROI). The collected data was compared to disc positions (normal, anterior disc displacement with reduction, anterior disc displacement without reduction), the presence of joint effusion. The relative signal intensity of retrodiscal tissue was significantly increased when the disc was displaced without reduction. And the relative signal intensity of retrodiscal tissue was significantly increased when joint effusion was present. The results suggest that evaluating the relative signal intensity of TMJ retrodiscal tissue using a T2-weighted MRI is valuable as a non-invasive tool for diagnosing the procession of TMD.

닥스훈트견의 바이러스성 뇌수막염에서 1.5T와 7T 자기공명영상을 이용한 진단 증례 (Meningoencephalitis in Dachshund Dog with Canine Distemper Virus Infection: 1.5 T and 7.0 T MRI Findings)

  • 강민희;박희명
    • 한국임상수의학회지
    • /
    • 제27권6호
    • /
    • pp.755-759
    • /
    • 2010
  • 6년령의 암컷 닥스훈트견이 2일전 발생한 발작증상으로 내원하였다. 기본 신체검사, 실험실 검사 및 신경검사를 통해, 뇌 질환에 의한 발작이 의심되었다. 환자는 1.5T와 7T 자기공명영상을 통한 진단이 시도 되었다. T2 영상에서 간뇌 에서 연수 부위까지 광범위한 고신호성 뇌병변이 관찰되었다. 뇌척수액의 중합효소연쇠반응(RT-PCR)을 통하여, 개 디스템퍼 바이러스가 검출되었으며, 이를 근거로, 개 디스템퍼 바이러스에 의한 뇌수막염이 최종 진단 되었다. 지속적인 상태 악화에 의해, 환자는 진단 7일 뒤 보호자의 요청에 의해 안락사가 실시되었다. 사후 부검을 통한 조직검사에서 자기공명영상과 같은 부위의 뇌병변이 확인 되었다. 결론적으로 본 증례는 바이러스에의한 뇌병변의 1.5T와 7T 자기공명영상을 통한 첫 번째 진단 증례 보고 이다.

Ultrashort Echo Time MRI (UTE-MRI) Quantifications of Cortical Bone Varied Significantly at Body Temperature Compared with Room Temperature

  • Jerban, Saeed;Szeverenyi, Nikolaus;Ma, Yajun;Guo, Tan;Namiranian, Behnam;To, Sarah;Jang, Hyungseok;Chang, Eric Y.;Du, Jiang
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권3호
    • /
    • pp.202-209
    • /
    • 2019
  • Purpose: To investigate the temperature-based differences of cortical bone ultrashort echo time MRI (UTE-MRI) biomarkers between body and room temperatures. Investigations of ex vivo UTE-MRI techniques were performed mostly at room temperature however, it is noted that the MRI properties of cortical bone may differ in vivo due to the higher temperature which exists as a condition in the live body. Materials and Methods: Cortical bone specimens from fourteen donors ($63{\pm}21$ years old, 6 females and 8 males) were scanned on a 3T clinical scanner at body and room temperatures to perform T1, $T2^*$, inversion recovery UTE (IR-UTE) $T2^*$ measurements, and two-pool magnetization transfer (MT) modeling. Results: Single-component $T2^*$, $IR-T2^*$, short and long component $T2^*s$ from bi-component analysis, and T1 showed significantly higher values while the noted macromolecular fraction (MMF) from MT modeling showed significantly lower values at body temperature, as compared with room temperature. However, it is noted that the short component fraction (Frac1) showed higher values at body temperature. Conclusion: This study highlights the need for careful consideration of the temperature effects on MRI measurements, before extending a conclusion from ex vivo studies on cortical bone specimens to clinical in vivo studies. It is noted that the increased relaxation times at higher temperature was most likely due to an increased molecular motion. The T1 increase for the studied human bone specimens was noted as being significantly higher than the previously reported values for bovine cortical bone. The prevailing discipline notes that the increased relaxation times of the bound water likely resulted in a lower signal loss during data acquisition, which led to the incidence of a higher Frac1 at body temperature.

직장암 병기결정에서 직장 CT의 진단능: 직장 MRI 및 병리결과와의 비교분석 (Diagnostic Performance of Rectal CT for Staging Rectal Cancer: Comparison with Rectal MRI and Histopathology)

  • 손석윤;서윤석;윤정희;허보윤;배재석;김세형
    • 대한영상의학회지
    • /
    • 제84권6호
    • /
    • pp.1290-1308
    • /
    • 2023
  • 목적 직장암 병기결정에서 직장 CT의 진단능을 고해상도 직장 MRI 및 병리결과와 비교분석 하였다. 대상과 방법 초음파 젤을 이용하여 직장을 팽창시킨 후 얻은 직장 CT와 고해상도 직장 MRI를 촬영한 66명의 직장암 환자가 포함되었다. 두 명의 위장관 영상의학과 의사가 직장 CT와 MRI에서 항문피부선/항문직장경계까지의 거리, 직장간막근막까지의 거리, 벽외침범 깊이, 직장간막외 림프절 침범, 벽외정맥침범, 및 T/N 병기를 평가하였다. 동시화학방사선요법을 시행 받지 않고 근치적 수술을 시행한 20명의 환자의 CT 소견을 병리결과와 비교하였다. 급내상관분석 및 카파 분석을 이용하여 통계 분석하였다. 결과 항문피부선/항문직장경계까지의 거리 측정에서 두 명의 영상의학과 의사 모두 CT와 MRI 간에 높은 상관관계를 보였다. 벽외침범 깊이, 직장간막근막까지의 거리, 림프절의 유무, 직장간막외 림프절 침범, 벽외정맥침범, T 병기 결정에서 CT와 MRI 간의 높은 일치도를 보였다. 수술을 시행받은 20명의 환자에서 T 병기, 측방절제연 침범, 벽외정맥침범, 림프절 전이 결정에서 CT는 병리결과와 만족할만한 일치율을 보였다. 결론 직장암 전용 CT는 직장암 환자의 병기 결정에 중요한 정보를 제공하며, 진단능은 고해상도 직장 MRI와 유사하다.

뇌 종양 등급 분류를 위한 심층 멀티모달 MRI 통합 모델 (Deep Multimodal MRI Fusion Model for Brain Tumor Grading)

  • 나인예;박현진
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.416-418
    • /
    • 2022
  • 신경교종(glioma)은 신경교세포에서 발생하는 뇌 종양으로 low grade glioma와 예후가 나쁜 high grade glioma로 분류된다. 자기공명영상(magnetic Resonance Imaging, MRI)은 비침습적 수단으로 이를 이용한 신경교종 진단에 대한 연구가 활발히 진행되고 있다. 또한, 단일 modality의 정보 한계를 극복하기 위해 다중 modality를 조합하여 상호 보완적인 정보를 얻는 연구도 진행되고 있다. 본 논문은 네가지 modality(T1, T1Gd, T2, T2-FLAIR)의 MRI 영상에 입력단 fusion을 적용한 3D CNN 기반의 모델을 제안한다. 학습된 모델은 검증 데이터에 대해 정확도 0.8926, 민감도 0.9688, 특이도 0.6400, AUC 0.9467의 분류 성능을 보였다. 이를 통해 여러 modality 간의 상호관계를 학습하여 신경교종의 등급을 효과적으로 분류함을 확인하였다.

  • PDF

Discretized solenoid design of a 1.5 T and a 3.0 T REBCO whole-body MRI magnets with cost comparison according to magnetic flux

  • Wonju Jung;Geonyoung Kim;Kibum Choi;Hyunsoo Park;Seungyong Hahn
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제25권4호
    • /
    • pp.75-80
    • /
    • 2023
  • Rare earth barium copper oxide (REBCO) materials have shown the possibility of high-temperature superconductor (HTS) magnetic resonance imaging (MRI) magnets due to their elevated transition temperature. While numerous MRI magnet designs have emerged, there is a growing emphasis on estimating the cost before manufacturing. In this paper, we propose two designs of REBCO whole-body MRI magnets: (1) 1.5 T and (2) 3.0 T, the standard center field choices for hospital use, and compare their costs based on conductor usage. The basis topology of the design method is based on discretized solenoids to enhance field homogeneity. Magnetic stress calculation is done to further prove the mechanical feasibility of their construction. Multi-width winding technique and outer notch structure are used to improve critical current characteristic. We apply consistent constraints for current margins, sizes, and field homogeneities to ensure an equal cost comparison. A graph is plotted to show the cost increase with magnetic flux growth. Additionally, we compare our designs to two additional MRI magnet designs from other publications with respect to the cost and magnetic flux, and present the linear relationship between them.