• Title/Summary/Keyword: t(8:21)(q22:q22)

Search Result 21, Processing Time 0.026 seconds

Acute Myeloid Leukemia with t(8;21)(q22;q22) (AML1/ETO) in a Patient with Marked Hypocellularity and Low Blasts Count

  • Chun, Sung-Ho;Cho, Hee-Soon;Lee, Chae-Hoon;Kim, Kyung-Dong;Kim, Min-Kyoung;Hyun, Myung-Soo;Jung, Soon-Il
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.1
    • /
    • pp.85-90
    • /
    • 2007
  • According to the World Health Organization (WHO) classification system, cases with t(8;21)(q22;q22) should be diagnosed as acute myeloid leukemia (AML) even with a blast count of less than 20 percent in blood or bone marrow. It is an uncommon manifestation, moreover hypocellularity is rarely observed in this subtype of leukemia. Here, we report a case of t(8;21) in a patient with marked hypocellularity of less than 5 percent and a blast count of less than 20 percent. This patient responded relatively well to chemotherapy. An allogeneic bone marrow transplantation was performed with good engraftment. This case suggests that hypocellular AML with a t(8;21) has as good a prognosis as hypercellular AML with t(8;21).

  • PDF

Combined Study of Cytogenetics and Fluorescence in Situ Hybridization (FISH) Analysis in Childhood Acute Lymphoblastic Leukemia (ALL) in a Tertiary Cancer Centre in South India

  • Mazloumi, Seyed Hashem Mir;Madhumathi, D.S.;Appaji, L.;Prasannakumari, Prasannakumari
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.8
    • /
    • pp.3825-3827
    • /
    • 2012
  • FISH is one of the most sensitive molecular methods to detect genetic abnormalities with DNA probes. When cytogenetic studies are normal or insufficient, FISH may detect cryptic rearrangements, rare or slowly proliferative abnormal populations in non-mitotic cells. We cytogenetically evaluated 70 childhood ALL - 67.1% were found to have an abnormal karyotype. The 23 patients (32.9%) with a normal karyotype were analyzed by FISH applying two probes; TEL/AML1 and MYB which detect cryptic rearrangements of t(12;21)(p13;q22) and deletion of (6q) respectively, associated with a good prognosis. Out of 23 patients, one was positive for t(12;21)(p13;q22) (4.3%). None of our patients were positive for MYB del(6q). Two patients showed an extra signal for MYB on chromosomes other than 6 (8.6 %) indicating amplification or duplication. Findings were compared with the available literature. Our study clearly indicated the integrated FISH screening method to increase the abnormality detection rate in a narrow range. FISH is less useful for diagnostic study of patients with suspected del(6q) but it helps in detecting known cryptic rearrangements as well as identification of new abnormalities(translocation , duplication and amplification) at the gene level.

Cytogenetic and Genetic Mutation Features of de novo Acute Myeloid Leukemia in Elderly Chinese Patients

  • Su, Long;Li, Xian;Gao, Su-Jun;Yu, Ping;Liu, Xiao-Liang;Tan, Ye-Hui;Liu, Ying-Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.895-898
    • /
    • 2014
  • Objectives: The present study aimed to examine the cytogenetic and genetic mutation features of acute myeloid leukemia (AML) in elderly Chinese patients. Methods: A retrospective analysis of cytogenetics and genetic mutations was performed in 113 cases (age range 50-82 years) with de novo AML. Results: The most frequent cytogenetic abnormality was t (15;17) (q22;q21), detected in 10.0% (n = 9) of successfully analyzed cases, followed by t (8;21) (q22;q22) in 8.89% (n = 8), and complex karyotypes in 5.56% (n = 5). Those with complex karyotypes included 4 cases (4.44%) of monosomal karyotypes. The frequencies of NPM1, FLT3-ITD, c-kit, and CEBPA mutations were 27.4% (31/113), 14.5% (16/110), 5.88% (6/102), and 23.3% (7/30), respectively. The complete remission rates of patients in low, intermediate, and high risk groups were 37.5%, 48.6%, and 33.3%, respectively (${\chi}^2$ = 0.704, P = 0.703) based on risk stratification. Conclusion: Cytogenetics and genetic mutations alone may not be sufficient to evaluate the prognoses of elderly AML patients. The search for a novel model that would enable a more comprehensive evaluation of this population is therefore imperative.

Sino-orbital Granulocytic Sarcoma Causing Bilateral Proptosis As an Initial Manifestation of Acute Myelogenous Leukemia (AML): A Case Report (급성 골수성 백혈병의 최초 증상으로 안구 돌출을 초래한 양측 안와-부비동 과립세포육종: 증례 보고)

  • Kim, Hee-Sun;Je, Bo-Kyung;Lee, Young-Hen;Kim, Baek-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.74-77
    • /
    • 2010
  • Granulocytic sarcoma is a manifestation of myelogenous leukemia, which means a solid mass consisting of primitive precursors of the granulocytic series of white blood cells. We present CT and MR imaging findings of bilateral sino-orbital granulocytic sarcoma in a 22-month-old boy. The mass involved bilateral orbital fossa which resulted in bilateral proptosis. Moreover, the mass extended to the almost skull base including paranasal sinuses, maxilla, temporal bone, zygomatic bone, sphenoid bone, ethmoid, and palatine bone. The adjacent dura was continuously thickened and the lower half of cavernous sinus was also involved. The patient was diagnosed as AML (M5) with t(8,21) translocation through a chromosome study from the bone marrow.

The Usefulness of Q.Clear Technique in PET / CT (PET/CT 검사에서 Q.Clear 기법의 유용성에 대한 고찰)

  • Choi, Yong Hoon;Kim, Jung Yul;Choi, Young Sook;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.31-36
    • /
    • 2017
  • Purpose Recently, the performance of PET/CT scanner has been improved and various techniques have been developed to increase the image quality such as Sensitivity and Resolution. The purpose of this study is to evaluate the usefulness of Q.Clear (a fully convergent iterative reconstruction) technique of GE Discovery IQ equipment to enhance the image quality. Materials and Methods All scans were acquired by Discovery IQ (GE Healthcare, MI, USA). In NEMA IEC Body Phantom test, Background to Hot-sphere (10 mm, 13 mm, 17 mm, 22 mm) ratio was 1:4 and scan time was 3 minutes. The images were reconstructed by VPHDs (VUE Point High-Definition + SharpIR) and Q.Clear to evaluate each Contrast. We injected 18F-FDG 187 M㏃ to PET/SPECT Performance Phantom. And then it was scanned for 4 minutes to evaluate Resolution and Uniformity. T-test statistical analysis was performed on SUVmax of small lesions less than 2 cm in 100 clinical patients regardless of disease type. Results In the NEMA IEC Body Phantom, the Contrast was $63.6{\pm}5.7%$ (VPHDs) and $75{\pm}4.8%$ (Q.Clear). In the PET/SPECT Performance Phantom, the Resolution was 9.2 mm (VPHDs) and 7.3 mm (Q.Clear). Uniformity of Q.Clear was 10.8% better than VPHDs. T-test statistic of the clinical patients showed a significant difference of p value of 0.021. Conclusion Both the phantom test and the clinical results showed that the quality of the image was improved in Q.Clear was applied. The SUVmax was highly measured in Q.Clear and the lesions were clearly distinguished visually. Therefore Q.Clear can be useful in various aspects such as dose-reduction, patients evaluation and image analysis.

  • PDF

Primary Production and Nutrients Distribution in 22-year-old Pinus koraiensis and Quercus mongolica Stands in Kwangju District (경기도 광주지방 22년생 잣나무 및 신갈나무림의 물질생산량과 무기영양물분포)

  • Lee, Kyong-Jae;Park, In-Hyeop
    • Journal of Korea Foresty Energy
    • /
    • v.7 no.1
    • /
    • pp.11-21
    • /
    • 1987
  • To estimate the biomass, net production and nutrient distribution of Pinus Koraiensis and Quercus mongolica stand, experimental plots located in Kwangju of Kyonggi-do were selected. Ten sample trees selected account of DBH distribution were felled and the diagram of oven-dry weight distrubution of leaves, branches and stems for each 1m segment was constructed. The logarithmic regression equations between dry weight of each component and the variable of $(DBH)^2$ H obtained. The standing crops were estimated to be as much as 152.07 and 156.02 tons of dry matter per hectare in P. koraiensis and Q. mongolica stand respectively. The net production was estimated as 24.66 and 20.35t/ha$\cdot$yr and the net assimilation rate was 1.90 and 3.42kg/kg$\cdot$yr in same order. Particulary large proportions of nitrogen. calcium and magnesium were found in soil of P. koraiensis stand, phosphours and potassium in overstory of it. At Q. mongolica stand, large proportions of nitrogen. phosphorus. potassium and magnesium were found in soil and calcium in overstory. The amounts of litter fall was 4.013t/ha$\cdot$8 months in P. koraiensis stand and 3.490t/ha$\cdot$8 months in Q. mongolica stand.

  • PDF

Prediction of Micro-Bubble Releasing Concentration with the Retention Time of a Micro-Bubble Generating Pump (미세기포 발생펌프 내 체류시간에 따른 미세기포의 발생 농도 예측)

  • Ambrosia, Matthew Stanley;Lee, Chang-Han
    • Journal of Environmental Science International
    • /
    • v.25 no.6
    • /
    • pp.829-837
    • /
    • 2016
  • The mechanism of micro-bubble generation with a pump is not clarified yet, so the design of water treatment systems with a micro-bubble generating pump is based on trial and error methods. This study tried to explain clearly quantitative relationships of experimental micro-bubble concentration ($C_{air}$) of continuous operation tests with a micro-bubble generating pump and theoretical air solubility. Operation parameters for the tests were discharge pressure ($P_g$), water ($Q_{w0}$) and air ($q_0$) flow rates, orifice diameter ($D_o$), and retention time (t). The experimental micro-bubble concentrations ($C_{air}$) at 4.8 atm of discharge pressure ($P_g$) were in the range of 21.04 to 25.29 mL/L. When the retention time (t) by changing the pipe line length ($L_p$) increased from 1.22 to 6.77s, the experimental micro-bubble concentrations ($C_{air}$) increased from 25.86 to 30.78 mL air/L water linearly. The dissolved and dispersed micro-bubble concentrations ($C_{air}$) are approximately 4 times more than the theoretical air solubility.

Feasibility Study of Docetaxel and Cyclophosphamide Six- Cycle Therapy as Adjuvant Chemotherapy for Japanese Human Epidermal Growth Factor Receptor 2-Negative Breast Cancer Patients

  • Abe, Hajime;Mori, Tsuyoshi;Kawai, Yuki;Tomida, Kaori;Kubota, Yoshihiro;Umeda, Tomoko;Tani, Tohru
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4835-4838
    • /
    • 2013
  • Background: We compared treatment completion rates and safety of docetaxel and cyclophosphamide sixcycle therapy (TC6) with docetaxel followed by 5FU, epirubicin and cyclophosphamide (T-FEC) therapy in Japanese patients with human epidermal growth factor receptor 2 (HER2)-negative breast cancer. Materials and Methods: We administered TC6 q3w or T-FEC q3w to HER2-negative breast cancer patients. The primary endpoint of this trial was toxicity. As second endpoints, the treatment completion rate and relative dose intensity were evaluated. Results: The TC6 and T-FEC group consisted of 22 and 21 patients, respectively. Concerning hematological toxicity, grade 3 or higher adverse reactions included neutropenia and febrile neutropenia. As non-hematological adverse events, exanthema and peripheral neuropathy were frequently reported in the TC6 group, whereas more patients of the T-FEC group reported nausea and vomiting. In TC6, the treatment completion rate was 86.4% and the relative dose intensity of docetaxel was 93.2%. In T-FEC, the values were 95.2% and 98.9%, respectively. Conclusions: These results suggest that TC6 is tolerable in Japanese, and that this regimen can also be performed in outpatient clinics. However, with the TC6 regimen, the compliance was slightly lower than with the T-FEC regimen, and supportive therapy needs to be managed appropriately.

Effects of the irrigation Rate on Wetted Patterns in Sandy Loam Soil Under Trickle irrigation Condition (점적관개에서 관개율이 Sandy Loam토양의 습윤양상에 미치는 영향)

  • 김철수;이근후
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.31 no.2
    • /
    • pp.104-115
    • /
    • 1989
  • In an effort to clarify the wetted patterns of sandy loam soil under trickle irrigation conditions, the distance of wetted zone, infiltration capacity and soil wetted patterns, etc. were measured by gypsum block as soil moisture sensor located every 5 cm vertically and horizontaly in the soil bin under the such conditions as a). irrigation rates set to 2, 4, 6, 8 liters per hour b). total amount of water applied fixed to 14.62 liters per soil bin c) the hearing force of soil measured by plate penetrometer ranging from 1.04 to 1.22kg/cm$_2$ The results can be summarized as follows ; 1. The wetted distance in horizontal direction(H), the wetted distance in vertical direction(D), the horizontal infiltration capacity (iH) and the vertical infiltration capacity(in)could by explained as a function of time t. 2. The horizontal wetted distance (H) is explained by an exponetial function H= a$.$ t where b was found ranging from 021 to 026 under surface trickle irrigation, which was considered a lotlower than the classical value of 0.5 and these measurements were indifferent to the increasing irrigation rates. 3. As for the surface trickle irrigation where horizontal infiltration capacity(iH) is explained as iH = A $.$ t h, the coefficient A increases with respect to irrigation rates within the limits of 0.89~1.34. 4. In terms of surface trickle irrigation of the ratio of Dm Which is maximum vertical wetted distance to Hm, which is maximum horizontal wetted distance, found to be within range of 1.0 to 1.21. It was also noted that the value of Dm decreses when irrigation rates increases while the value of Hm changes the opposite direction. 5. The optimum location of sensors from emitter for surface trickle irrigation should he inside of hemisphere whose lateral radius is 28~30cm long and vertical radius is 10~12cm long. The distance between emitters should be within 60cm long. 6. In the study of vertical wetted distance( D) where D= a $.$ tb, the exponential coefficient b ranged from 0.61 to 0.75 in surface trickle irrigation, and from 0A9 to 0.68 for subsurface trickle irrigation. These measurements showed an increasing tendency to with respect to irrigation rates. 7. In case of vertical infiltration capacity( in), where iD= A $.$ t 1-h, the coefficient A for surface trickle irrigation found to be within range of 0.16 to 0.19 and did not show any relationships with varying degree of irrigation rates. However, the coefficient was varying from 0.09 to 0.22 and showed a tendency to increase vis-a-vis irrigation rates for subsurface trickle irrigation, in contrast. 8. In the observation of subsurface trickle irrigation, it was found that Dm/Hm ratio was within 1.52 to 1.91 and showed a decreasing tendency with respect to increasing rates of irrigation. 9. The location of sensors for subsurface trickle irrigation follows same pattern as above, with vertical distance from emitter being 10~17cm long and horizontal 22~25cm long. The location of emitter should be 50 cm. 10.The relationship between VS which is the volume of wetted soil and Q which is the total amount of water when soil is reached field capacity could be explained as VS= 2.914Q0.91and the irrigation rates showed no impacts on the above relationship.

  • PDF

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.