• Title/Summary/Keyword: systolic and diastolic blood pressure

검색결과 912건 처리시간 0.025초

노인의 식이섭취 실태와 건강상태에 관한 연구 II -영동지역을 중심으로- (A study on the dietary intake and health of aged person II -Based in elderly person in Young Dong area-)

  • 염초애;장명숙;이현옥
    • 한국식품영양과학회지
    • /
    • 제16권4호
    • /
    • pp.317-322
    • /
    • 1987
  • The Purpose of this study· was to investigate the dietary intake and health for male and female old persons living in Young Dong by mean of questionnaire and interview. The results from the above survey are summerized as follows ; 1. The aged average height, weight, and physical index were 166cm, 60kg, 19.31 in male, 156cm, 50kg, 20.27 in female which were almost the same as the Korean average standard (male; 167. 0cm, 61. 0kg, 21.8, female; 156cm, 53.0kg, 21.8). Among the condition of diseases, neuralgia was 45.3%, hypertension was 12.2%, constipation was 10.4%. 2. Correlation coefficients between systolic blood pressure, diastolic blood pressure and age were significant(P<0.05, P<0.01), and also those between systolic blood pressure, diastolic blood pressure and Body Mass Index were significant(P<0.01, P<0.005). 3. Correlation of food intake frequency of protein group, calcium group, vitamin and mineral group was divided three levels-Good, Fair, Poor. Food intake frequency as the factors(three groups) which might influence the condition of health was partly significant (P<0.05, P<0.1).

  • PDF

집단동작훈련이 시설노인의 생리, 심리적 변수 및 관절운동범위에 미치는 영향 (The Effects of Group Movement Training on Psychophysiological Variables and the Range of Motion in the Institutionalized Elderly)

  • 서부덕
    • 지역사회간호학회지
    • /
    • 제20권4호
    • /
    • pp.403-411
    • /
    • 2009
  • Purpose: The purpose of this study is to explore the effects of a group movement exercise program on psychophysiological variables in the institutionalized elderly. Methods: This research adopted the non-equivalent control group pretest-posttest design. Twenty elders were selected as an experimental group, whereas twenty-two elders were as a control group. The group movement program consisted of 35 minutes of dance and three days a week for eight weeks. Resting systolic blood pressure, diastolic blood pressure and heart rate were measured in a relaxed sitting position. The range of flexion and extension of joint was measured with a gonimeter. Life satisfaction and self-efficacy were measured by self-report. Data were analyzed through $x^2$-test, t-test and ANCOVA using SPSS/WIN program. Results: The results were as follows: Resting systolic blood pressure, diastolic blood pressure and resting heart rate decreased significantly by the group movement training. The range of flexion and extension of the shoulder and hip joints increased significantly. The scores of life satisfaction and self-efficacy increased remarkably by the group movement. Conclusion: The results suggest that group movement training can be an effective intervention to improve psychophysiological variables and the range of motion for the institutionalized elderly.

  • PDF

The Correlation of Pulse Wave Velocity and Atherosclerotic Risk Factor in Stroke Patients

  • Jin, Bok Hee;Han, Min Ho
    • 대한임상검사과학회지
    • /
    • 제47권1호
    • /
    • pp.28-34
    • /
    • 2015
  • Pulse wave velocity (PWV) is used to non-invasively estimate the severity of arteriosclerosis by measuring arterial stiffness. Increased arterial stiffness measured by PWV stands for progressive arteriosclerosis and is caused by atherosclerotic risk factors. This study is focused on how brachial-ankle pulse wave velocity (baPWV) is related to the leading risk factors for arteriosclerosis or atherosclerosis. Subjects were 114, 69 males and 45 females who are in 60's and had baPWV test for acute stroke. The results are as follows: the group with increased arterial stiffness showed significant increase in HbA1c, total cholesterol, BSBP (brachial artery systolic blood pressure), BDBP (brachial artery diastolic blood pressure), CSBP (central artery systolic blood pressure), CDBP (central artery diastolic blood pressure), augmentation index (AIx) and diabetes mellitus. Correlation analysis between baPWV and atherosclerotic risk factor showed significant relationship in age, HbA1c, LDL cholesterol, BSBP, BDBP, CSBP, CDBP and augmentation index. baPWV was independently related to age and BSBP in multiple linear regression analysis. The group with increased arterial stiffness was independently related to BDBP in multiple logistic regression analysis. This study might be meaningful in evaluating the relationship between arterial stiffness and atherosclerotic risk factor in a new way, and be helped to make various studies for cardiovascular disease.

가압식 오실로메트릭 방법을 사용한 혈압측정 시스템의 설계 (Design of the Blood Pressure Measurement System Using the Inflatable Oscillometric Method)

  • 노동곤;이윤선;지정호;박성빈;이계형;김해관
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권4호
    • /
    • pp.281-286
    • /
    • 2003
  • 혈압은 사람의 건강상태를 알 수 있는 가장 기본적인 의학적 파라메터 중 하나이며, 오실로메트릭 방법을 사용한 혈압측정 시스템은 팔 동맥에서 커프를 통해 나타나는 압력을 측정함으로써 혈압수치를 비침습적으로 모니터링 하는 장치이다. 된 논문에서는 커프에 공기를 주입하면서 혈압을 측정하는 가압식 손목형 혈압측정 시스템을 설계하였다 설계한 혈압측정 시스템은 전원부와 압력을 가하는 공기주머니를 포함하는 커프, 신호검출부, 신호처리부, 무선 송수신부 그리고 디스플레이부로 구성된다. 설계한 자동 혈압측정 시스템은 기존에 일반적으로 사용되고 있는 자동혈압측정 시스템과의 수축기, 이완기 혈압 및 심박동수의 비교분석을 통해 신뢰성을 평가하였다. 수축기 혈압과 이완기 혈압을 결정하기 위해 MAA (Maximum Amplitude Algorithm)를 사용하였고, 적용한 특성비율은 0.436. 0.671이 었다.

아로마 자가발반사마사지가 농촌 중년여성의 스트레스와 면역 반응 및 피로에 미치는 효과 (Effects of Aroma Self-Foot Reflexology Massage on Stress and Immune Responses and Fatigue in Middle-Aged Women in Rural Areas)

  • 김자옥;김인숙
    • 대한간호학회지
    • /
    • 제42권5호
    • /
    • pp.709-718
    • /
    • 2012
  • Purpose: This study was done to examine the effects of aroma self-foot reflexology massage on stress and immune responses and fatigue in middle-aged women in rural areas. Methods: The study was a nonequivalent control group pre-post test design. The participants were 52 middle-aged women from rural areas of which 26 were assigned to the experimental group and 26 to the control group. Data were collected from July to September, 2011 and analyzed using SPSS Win 17.0 version program. The intervention was conducted 3 times a week for six weeks. Results: There were significant differences in reported perceived stress, systolic blood pressure, diastolic blood pressure and fatigue between the two groups. However, the issue of salivary cortisol and immune response were not significant. Conclusion: Aroma self-foot reflexology massage can be utilized as an effective intervention for perceived stress, systolic blood pressure, diastolic blood pressure and fatigue in middle-aged woman in rural areas.

Tiletamine/zolazepam 마취견에서 전침자극이 순환기계에 미치는 영향 (Effects of Electroacupuncture at Some Acupoints on the Cardiovascular System in Dogs Anesthetized with Tiletamine/zolazepam)

  • 강한샘;장환수;이문학;엄기동;장광호
    • 한국임상수의학회지
    • /
    • 제20권2호
    • /
    • pp.224-228
    • /
    • 2003
  • This study was performed to evaluate the effect of electroacupuncture at some acupoint combinations on the cardiovascular system, especially on blood pressure. Electroacupuncture at acupoint combinations of CV2O(+)/GV-16(-),4(+)/GV16(-), KI1(+)/GV20(-), and HT9(+)/GV16(-) did not changed heart rates and blood pressure, but stimulation of HT1(+)/HT7(-) Increased systolic, diastolic and mean arterial blood pressure significantly in dogs anesthetized with tiletamine/zolazepam.

등맛사지가 개심술 환자의 불안 및 면역반응에 미치는 효과 (The Effect of Slow Stroke Back Massage on Anxiety and Immune Response in the Patients undergoing Open Heart Surgery)

  • 김혜순;이향련
    • 대한간호학회지
    • /
    • 제28권4호
    • /
    • pp.980-991
    • /
    • 1998
  • The purpose of this study was to examnin the effect of slow stroke back massage(SSBM) on anxiety and immune response in patients undergoing open heart surgery and to compare the effect of 5-minutes with 10-minutes SSBM. Among the sixty-four patient subjects, twenty-one were one experimental group receiving massage for 10-minutes, twenty for the other experimental group receiving massage for 5-minutes and twenty-three for the control group. Subjects were admitted at Hospitals in Inchon and Puchon for open heart surgery. This study was carried out from October 10, 1997 to May 10, 1998. The levels of anxiety were measured by the Visual Analogue Scale(VAS), Trait anxiety scale, systolic and diastolic blood pressure, pulse rate, blood cortisol and the levels of immune response were measured by the blood T-lymphocyte and Natural killer cell. Study measurements were taken before and after SSBM on the 1st post operative day. Data were analyzed using x$^2$ test, oneway ANOVA, paired t-test, t-test and Pearson product moment correlation. The results were summarized as follows : 1. After SSBM, VAS anxiety level, systolic and diastolic blood pressure and pulse rate of the experimental group were decreased significantly than those measurements before the SSBM. After SSBM, significant difference in the VAS anxiety level, systolic blood pressure and pulse rate between the experimental and control groups were found. 2. After SSBM, the blood cortisol of the experimental and control groups were increased significantly compared with before SSBM. But the significant difference in blood cortisol between the two groups was not found. 3. After SSBM, the blood T-lymphocyte percentages of the experimental and control groups were decreased signigicantly and blood Natural killer cell percentages of the two groups were increased compared with before SSBM. But significant difference in blood T-lymphocyte and Natural killer cell percentages between the two groups was not found. 4. Significant difference in VAS anxiety level, systolic and diastolic blood pressure, pulse rate, blood cortisol, blood T-lymphocyte and Natural killer cell percentages between SSBM for 5 minutes and SSBM for 10 minutes were not found. Based upon the results, this study concludes that the slow stroke back massage for 5 minutes is a useful intervention that decreases anxiety and produces relaxation in patients undergoing open heart surgery.

  • PDF

일부 도시노인들의 고혈압증 유병률 (Prevalence of Hypertension Among the Aged in Urban Area)

  • 김석범;강복수;정종학
    • Journal of Yeungnam Medical Science
    • /
    • 제4권1호
    • /
    • pp.123-128
    • /
    • 1987
  • 도시 노인들의 고혈압증의 빈도 및 분포를 파악하기 위하여 1986년 1월부터 동년 12월 사이에 대구시에 거주하는 노인 남자 565명, 여자 762명 총 1,327명에 대해 조사한 성적을 요약하면 다음과 같다. 수축기혈압의 평균치는 $134.2{\pm}24.78mmHg$로 남자 $136.0{\pm}25.01mmHg$, 여자 $133.0{\pm}24.56mmHg$였다. 이완기혈압의 평균치는 $83.0{\pm}14.43mmHg$로 남자 $83.7{\pm}14.41mmHg$, 여자 $82.4{\pm}14.43mmHg$였다. 세계보건기구의 기준에 따른 고혈압증 유병률에 있어 pure systolic hypertension (${\geq}160$/<95mmHg)인 자는 7.2%로 남자 7.8%, 여자 6.8%였다. Pure diastolic hypertension (<160/${\geq}95mmHg$)인 자는 4.8%로 남자 6.0%, 여자 3.9%였다. Both systolic and diastolic hypertension (${\geq}60/{\geq}95mmHg$)인 자는 12.9%로 남자 13.5%, 여자 12.9%였다. 합동위원회의 기준에 의하면 normal (/<90mmHg)인 자는 49.1%로 남자 46.7%, 여자 50.8%였다. Mild hypertension (/90-104mmHg)인 자는 34.6%로 남자 34.5%, 여자 34.6%였다. Moderate hypertension (/105-114mmHg)인 자는 3.6%로 남자 5.1%, 여자 2.5%였다. Severe hypertension ($/{\geq}115mmHg$)인 자는 2.7%로 남자 2.3%, 여자 3.0%였다. Boderline isolated systolic hypertension (140-159/<90mmHg)인 자는 7.6%로 남자 9.0%, 여자 6.6%였다. Isolated systolic hypertension (${\geq}160$/<90mmHg)인 자는 2.4%로 남자 2.3%, 여자 2.5%였다.

  • PDF

Compensation of the Error Rate for the Non-invasive Sphygmomanometer System Using a Tactile Sensor

  • Jeong, In-Cheol;Choi, Yoo-Nah;Yoon, Hyung-Ro
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.136-141
    • /
    • 2007
  • The Purpose Of This Paper Is To Use A Tactile Sensor To Compensate The Error Rate. Most Automated Sphygmomanometers Use The Oscillometric Method And Characteristic Ratio To Estimate Systolic And Diastolic Blood Pressure. However, Based On The Fact That Maximum Amplitude Of The Oscillometric Waveform And Characteristic Ratio Are Affected By Compliance Of The Aorta And Large Arteries, A Method To Measure The Artery Stiffness By Using A Tactile Sensor Was Chosen In Order To Integrate It With The Sphygmomanometer In The Future Instead Of Using Photoplethysmography. Since Tactile Sensors Have Very Weak Movements, Efforts Were Made To Maintain The Subject's Arm In A Fixed Position, And A 40hz Low Pass Filter Was Used To Eliminate Noise From The Power Source As Well As High Frequency Noise. An Analyzing Program Was Made To Get Time Delay Between The First And Second Peak Of The Averaged Digital Volume Pulse(${\Delta}t_{dvp}$), And The Subject's Height Was Divided By ${\Delta}t_{dvp}$ To Calculate The Stiffness Index Of The Arteries($Si_{dvp}$). Regression Equations Of Systolic And Diastolic Pressure Using $Si_{dvp}$ And Mean Arterial Pressure(Map) Were Computed From The Test Group (60 Subjects) Among A Total Of 121 Subjects(Age: $44.9{\pm}16.5$, Male: Female=40:81) And Were Tested In 61 Subjects To Compensate The Error Rate. Error Rates Considering All Subjects Were Systolic $4.62{\pm}9.39mmhg$, And Diastolic $14.40{\pm}9.62mmhg$, And Those In The Test Set Were $3.48{\pm}9.32mmhg,\;And\;14.34{\pm}9.67mmhg$ Each. Consequently, Error Rates Were Compensated Especially In Diastolic Pressure Using $Si_{dvp}$, Various Slopes From Digital Volume Pulse And Map To Systolic-$1.91{\pm}7.57mmhg$ And Diastolic $0.05{\pm}7.49mmhg$.

측정도구와 방법에 따른 간접혈압측정치의 비교연구 (Comparative Study About The Indirect Blood Pressure (measured by different Instruments and Methods))

  • 서길희
    • 기본간호학회지
    • /
    • 제1권1호
    • /
    • pp.51-68
    • /
    • 1994
  • One aim of this study was to find out the difference of indirect blood pressure between the types of instruments. The difference of indirect blood pressure was measured with mercury sphygomomanometer and electronic blood pressuremeter. Another was to determine the difference of indirect blood pressure according to width of cuff and site of cuff. Indirect blood pressures were measured with the diaphragmatic side of sphygomomanometer. The subjects were 40 female volunteers, whose arm circumferences were from 22 to 34cm. The data were analyzed by SPSS-PC program and pared t-test was used. The results are summarized as follows ; 1. Mercury sphygomomanometer systolic pressure was higher(average 2.20mmhg) than electronic blood pressuremeter. It was statistically significant(p=0.026). 2. The value of Mercury sphygomomanometer diastolic pressure was lower(2.00mmhg) than electronic's. It was statistically significant(p=0.03) 3. In the mercury sphygomomanometer systolic pressure, the value of standard cuff($12{\times}23cm$) was higher(2.40mmhg) than large one's($14{\times}45cm$). It was statistically significant(p=0.007). 4. In diastolic pressure(K4), the value of standard cuff was higher(0.65mmhg) than large cuff's. It was not statistically significant(p=0.481). In K5, the value of standard cuff($12{\times}23cm$) was higher(0.55mmhg) than large cuff's. It was not statistically significant(p=0.541). 5. Difference according to site of showed that the values of systolic pressure over elbow joint were higher(20.00mmhg, 26.45mmhg) than ones at site of elbow joint. It was significant statistically(p=0.000) and clinically. 6. The values of diastolic pressure(K4) over elbow joint were higher(17.10mmhg, 21.60mmhg) than ones at site of elbow joint. It was significant statistically (p=0.000) and clinically. The values of K5 over elbow joint were higher(17.25mmhg, 22.15mmhg) than ones at site of elbow joint. It was significant statistically(p=0.000) and clinically. I think similar studies about indirect blood pressure according to diseases and positions are necessary. In addition, similar studies, are required about accuracy of method electronic blood pressuremeter according to site of mesurement.

  • PDF