Browse > Article

Design of the Blood Pressure Measurement System Using the Inflatable Oscillometric Method  

노동곤 (연세대학교 의공학과)
이윤선 (연세대학교 의공학과)
지정호 ((주)빈즈메디칼)
박성빈 ((주)빈즈메디칼)
이계형 ((주)빈즈메디칼)
김해관 (연세대학교 의공학과)
Publication Information
Journal of Biomedical Engineering Research / v.24, no.4, 2003 , pp. 281-286 More about this Journal
Abstract
Blood Pressure is one of the most fundamental Parameters which reflects physical conditions medically and the blood pressure measurement system using oscillometric method is a Non-Invasive Blood Pressure measurement device by measuring arterial Pressure through a cuff. In this paper. we designed a inflatable wrist blood pressure system which measures blood Pressure during the stepping inflation in the wrist cuff. The hardware system consists of a main power unit, a bladder in cuff unit, signal detection units, signal Processing units. a wireless data transmission unit, and a data display unit. We evaluated the reliability of this system by comparing and analyzing systolic. diastolic blood Pressure, and heart rate with other commercial blood Pressure measurement devices. Characteristic ratio values used to determine systolic and diastolic blood Pressure using MAA(Maximum Amplitude Algorithm) were 0.436 and 0.671 respectively.
Keywords
Blood pressure measurement system; Stepping inflation; Characteristic ratio;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Pression et vitesse du sang /
[ E.J.Marey ] / Physiologic Experimentale
2 /
[ 보건복지부 ] / 2001년도 고혈압 · 당뇨관리사업 지침
3 /
[ Lee A. Taylor;Ronald G. Bennett;Thomas J. Dorsett ] / The Application of Signal Averaging to the NIBP Oscillometric Waveform
4 Indirect blood pressure measurement Doppler ultrasonic kinetoarterio graphy /
[ Ware R.W.;Laenger C.J. ] / Proc 20th Ann Conf. Eng Med Biol.
5 /
[ J.N.Amoore;W.B.Geake;D.H.Scott ] / The Effects of Pulse Rate, Artefact and Pulse Strength on Oscillometric Non-Invasive Blood Pressure Measurements
6 The Korotkoff sound /
[ G.M.Drzewiecki;J.Melbin;A.Noordergraaf ] / Ann. Biomedical Eng.   DOI   ScienceOn
7 /
[ JCBT Moraes;M.Cerulli ] / A Strategy for Determination of Systolic, Mean and Diastolic Blood Pressures from Oscillometric Pulse Profiles
8 Evaluation of a new Oscillometric Blood Pressure Monitor by Cuff Inflation Method /
[ M.Nakajima;T.Komatsu;T.Kimura;Y.Fujiwara;Y.Shimada ] / Anesthesiology
9 Measurement of Non-Invasive Oscillometric Blood Pressure During Cuff Inflation, Rather than deflation /
[ N.Morioka;M.Ozaki;K.Ozaki;DI Sessler;T.Matsukawa;H.Suzuki ] / Anesthesiology   DOI