• 제목/요약/키워드: system separation method

검색결과 739건 처리시간 0.028초

Effective Separation Method for Single-Channel Time-Frequency Overlapped Signals Based on Improved Empirical Wavelet Transform

  • Liu, Zhipeng;Li, Lichun;Li, Huiqi;Liu, Chang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권5호
    • /
    • pp.2434-2453
    • /
    • 2019
  • To improve the separation performance of time-frequency overlapped radar and communication signals from a single channel, this paper proposes an effective separation method based on an improved empirical wavelet transform (EWT) that introduces a fast boundary detection mechanism. The fast boundary detection mechanism can be regarded as a process of searching, difference optimization, and continuity detection of the important local minima in the Fourier spectrum that enables determination of the sub-band boundary and thus allows multiple signal components to be distinguished. An orthogonal empirical wavelet filter bank that was designed for signal adaptive reconstruction is then used to separate the input time-frequency overlapped signals. The experimental results show that if two source components are completely overlapped within the time domain and the spectrum overlap ratio is less than 60%, the average separation performance is improved by approximately 32.3% when compared with the classic EWT; the proposed method also improves the suitability for multiple frequency shift keying (MFSK) and reduces the algorithm complexity.

Separation of Burnup Monitors in Spent Nuclear Fuel Samples by Liquid Chromatography

  • Joe, Kih-Soo;Jeon, Young-Shin;Kim, Jung-Suck;Han, Sun-Ho;Kim, Jong-Gu;Kim, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권4호
    • /
    • pp.569-574
    • /
    • 2005
  • A coupled column liquid chromatography system was applied for the separation of the burnup monitors in spent nuclear fuel sample solutions. A reversed phase column was studied for the adsorption behavior of uranyl ions using alpha-hydroxyisobutyric acid as an eluent and used for the separation of plutonium and uranium. A cation exchange column prepared by coating 1-eicosylsulfate onto the reversed phase column was used for the separation of the lanthanides. In addition, retention of Np was checked with the reversed phase column and cation exchange column, respectively, according to the oxidation states to observe the interference effect for the separation of burnup monitors. This chromatography system showed a great reduction in separation time compared to a conventional anion exchange method. A good agreement from the burnup data was obtained between for this method and a conventional anion exchange method to within 1% of a difference for the spent nuclear fuel samples of about 40 GWD/MTU.

Memtrane SEparation of Activated Sludge for Waste Water Treatment and Water Recycle

  • Miyano, O-Tadadki;Yohgi Inoue;Toyozo Hamada;Shuji Nakatsuka
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1999년도 Energy Saving Membrane Separtion Systems 에너지 절약형 막분리 시스템
    • /
    • pp.39-39
    • /
    • 1999
  • Membrane separation technology has become a more attractive technology on waste water treatment and water recycle in recent years. On this application, membrane does not take main part of treatment, such as decomposition or handling of organic matter in the waste water, but it is very important supporting method in the total system. Activated sludge is most popular method as main part. In the system , membrane works as a separator to obtain clear water after biological treatment, by which the permeate could be released, recycled or applied to further additional treatment, instead of conventional sedimentation, coagulation and sand filtration. We would like to introduce our system cases for waste water treatment and water recycle, in which membrane separation technology works. In most of cases, membranes are applied to solid- liquid separation of activated sludge. Our experiences will be introduced as following items.

  • PDF

Performance Comparison of Two Ellipse Fitting-Based Cell Separation Algorithms

  • Cho, Migyung
    • Journal of information and communication convergence engineering
    • /
    • 제13권3호
    • /
    • pp.215-219
    • /
    • 2015
  • Cells in a culture process transform with time and produce many overlapping cells in their vicinity. We are interested in a separation algorithm for images of overlapping cells taken using a fluorescence optical microscope system during a cell culture process. In this study, all cells are assumed to have an ellipse-like shape. For an ellipse fitting-based method, an improved least squares method is used by decomposing the design matrix into quadratic and linear parts for the separation of overlapping cells. Through various experiments, the improved least squares method (numerically stable direct least squares fitting [NSDLSF]) is compared with the conventional least squares method (direct least squares fitting [DLSF]). The results reveal that NSDLSF has a successful separation ratio with an average accuracy of 95% for two overlapping cells, an average accuracy of 91% for three overlapping cells, and about 82% accuracy for four overlapping cells.

초전도 자기분리에 의한 냉연공정 폐수처리 (Treatment of rolling cooling waste water by superconductor HGMS method)

  • 김태형;하동우;오상수;김영훈;하태욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.295-295
    • /
    • 2008
  • This study introduced waste water treatment method applied superconductor HGMS(High Gradient Magnetic Separation). HGMS method treat high efficient method for various waste water. we have surveyed superconducting magnetic separation technology and reviewed the status of related industries using applied superconductivity. We fabricated the prototypes of magnetic matrix filter consisting of stainless steel mesh, which is a core component in the magnetic separation system. In our basic preliminary experiment using HGMS, it was made clear that the fine para-magnetic particles in the rolling colling wasted water obtained from rolling process of POSCO can be separated with high efficiency.

  • PDF

인공위성 탑재컴퓨터를 위한 리눅스 기반 ARINC 653 공간 분리 (Linux-based ARINC 653 Space Separation for Spacecraft Computer)

  • 김덕수;조현우;김형신
    • 대한임베디드공학회논문지
    • /
    • 제9권5호
    • /
    • pp.253-260
    • /
    • 2014
  • European Space Agency has recognized Integrated Modular Avionics and ARINC specification 653 as avionics computer system for space application. Integrated Modular Avionics specification reduces the space by integrating a system composed of many electronic devices into a computer. recent researches have been studying how to apply the ARINC 653 into an open source operating system, such as Linux. These studies have concentrated on partition scheduling for time separation. However, requirements to guarantee spatial separation should be further analyzed to ensure deterministic execution time. Therefore, memory management is needed to verify spatial isolation on Linux systems. This research proposes a new method to accomplish spatial isolation for the ARINC 653 specification in Linux. We have added new data structures and system calls to handle functionalities for spatial separation. They are used during the partition startup process. The proposed method was evaluated on the LEON4 processor, which is the next generation microprocessor to be used in the future space missions. All implementations confirm that spatial isolation of the ARINC 653 specification was accomplished.

유도성 시스템으로부터 무선기기 보호를 위한 이격 거리에 관한 연구 (Study on Separation Distance to Protect Radio Service from Inductive System)

  • 이일규;심용섭;민경일;차재상;이경근
    • 한국위성정보통신학회논문지
    • /
    • 제6권1호
    • /
    • pp.103-108
    • /
    • 2011
  • 본 논문은 산업현장 뿐만 아니라 가정의 일생생활에서 그 사용이 점차 증가하고 있는 유도성 시스템과 기존의 무선기기에 대한 간섭에 관한 것이다. 자계강도 간섭 신호를 방사하는 유도성 시스템의 간섭을 분석하기 위한 모델을 제시하였고 이 모델을 바탕으로, 측정을 통해 구해진 유도성 시스템의 자계강도는 마그네틱 다이폴 모멘트로 변환되고 무선기기의 허용 가능한 간섭 레벨을 고려하여 유도성 시스템으로부터 무선기기를 보호하기 위해 요구되는 이격 거리를 산출하는 방법을 제시하였다. 또한, 실제 적용 가능한 시나리오를 설정하고 본 논문에서 제시한 방법을 이용하여 유도성 시스템으로부터 무선기기를 보호하기 위한 이격거리를 산출하였다. 본 논문에서 제시한 이격 거리 산출 방법은 유도성 시스템과 무선기기의 양립성 확보에 기여할 것이다.

마운트계의 실험적 설계변경을 위한 전달함수분리법의 개발 (Development of Transfer Function Separation Method for Experimental Dynamic Modification of Mounted System)

  • 정의봉;조영희
    • 소음진동
    • /
    • 제7권5호
    • /
    • pp.847-852
    • /
    • 1997
  • Many investigations about the dynamic analysis of the structural system based on the BBA(Building Block Approach) method which predict dynamic characteristics of synthesized structures from each structure. But it is actually sometimes difficult to remove mounts from structures. In this paper, TFSM(The Transfer Function Separation Method) is developed which can predict dynamic characteristics of separated structures from the data of vibrational experiment of the synthesized structures. By combining TFSM with BBA, this paper also proposes the method which can predict dynamic characteristics of mount-modified structure without removing mounts from structures. And the proposed method is verified by the experimental data of plates.

  • PDF

Frit-Inlet Asymmetrical Flow Field-Flow Fractionation (FI-ARIFF): A Stopless Separation Technique for Macromlecules and Nanopariticles

  • 문명희
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권4호
    • /
    • pp.337-348
    • /
    • 2001
  • This article gives an overview of a recently developed channel system, frit-inlet asymmetrical flow field-flow fractionation (FI-AFlFFF), which can be applied for the separation of nanoparticles, proteins, and water soluble polymers. A conventiona l asymmetrical flow FFF channel has been modified into a frit-inlet asymmetrical type by introducing a small inlet frit near the injection point and the system operation of the FI-AFlFFF channel can be made with a great convenience. Since sample components injected into the FI-AFlFFF channel are hydrodynamically relaxed, sample injection and separation processes proceed without interruption of the migration flow. Therefore in FI-AFlFFF, there is no requirement for a valve operation to switch the direction of the migration flow that is normally achieved during the focusing/relaxation process in a conventional asymmetrical channel. In this report, principles of the hydrodynamic relaxation in FI-AFlFFF channel are described with equations to predict the retention time and to calculate the complicated flow variations in the developed channel. The retention and resolving power of FI-AFlFFF system are demonstrated with standard nanospheres and protreins. An attempt to elucidate the capability of FI-AFlFFF system for the separation and size characterization of nanoparticles is made with a fumed silica particle sample. In FI-AFlFFF, field programming can be easily applied to improve separation speed and resolution for a highly retaining component (very large MW) by using flow circulation method. Programmed FI-AFlFFF separations are demonstrated with polystyrene sulfonate standards and pululans and the dynamic separation range of molecular weight is successfully expanded.

계의 분리법에 의한 제약 조건이 주어진 계의 열교환망 합성 (Heat Exchanger Network Synthesis for the System with Constraints Using System Separation Method)

  • 이해평;이인영;류경옥
    • 에너지공학
    • /
    • 제4권1호
    • /
    • pp.13-22
    • /
    • 1995
  • 공정산업에서 열교환망의 최적화를 통한 에너지 회수 및 절감 기술의 개발을 목적으로, 여러 개의 핀치를 갖거나 또는 안전 및 배열 등과 같은 제약조건들이 주어진 계를 대상으로, 계의 분리법(system separation method)을 적용하여 신뢰도가 높은 목표값(target)을 설정하는 연구의 일환이다. 본 연구에서는 그 목표값의 10% 이내에 도달할 수 있도록 실제적인 열교환망 합성을 수행하는 프로그램 개발에 중점을 두었으며, 조업 중인 기존 공정에 적용해 본 결과, 연간 총비용의 15% 정도를 절감할 수 있는 결과를 얻을 수가 있었다.

  • PDF