• Title/Summary/Keyword: system restraint

Search Result 186, Processing Time 0.032 seconds

A Study on the 2nd Harmonic Blocking Scheme and Setting Value of a Current Differential Relay for 154 kV Transformers to Prevent Maloperation (154 kV 변압기 보호용 비율차동계전기 오동작 방지를 위한 2고조파 억제 방식의 적용방법 및 정정값에 관한 연구)

  • Son, Yong-Beom;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.29-37
    • /
    • 2018
  • Inrush current and fault current in a transformer need to be distinguished from one another. In order to do this, KEPCO uses a 2nd harmonic restraint/block method. We use two setting values for 2nd harmonic restraint; 15% and 10%. We also apply per-phase blocking method among various harmonic restraint methods. If the transformer is located at the radial system, we adjust 10% in the 2nd harmonic restraint, but this method is not enough to prevent mal-operations of the current differential relay and let us spend more time to change setting value again as the power system changes. In this paper, a more reasonable setting value for a 2nd harmonic blocking scheme in KEPCO is proposed. To present a proposed method, the fault data of the current differential relays which have occurred since 2009 are analyzed. To evaluate the performance of the proposed method, the results of the RTDS test for the current differential relay of the transformer by KEPCO are analyzed.

The Effects of 120Hz High Frequency Electroacupuncture on the Cold-Restraint-Induced Gastric Mucosal Damages (Cold-Restraint 스트레스 유발 위점막손상에 미치는 고빈도 120Hz 전침의 효과)

  • Jo, Mee-hyeong;Choi, Byung-tae;Jang, Kyung-jeon
    • Journal of Acupuncture Research
    • /
    • v.20 no.3
    • /
    • pp.177-193
    • /
    • 2003
  • Objective : The present studies investigated the effects of 120Hz high frequency electroacupunctue(EA) on the stress-induced stomach dysfunction in relation to its effect on the level of stress hormone and gastric mucosal damages. The gastric mucosal injury was induced by cold-restraint stress and two acupoints corresponding to Zusanli and Sanyinjiao in man were used. Methods: Cold-restraint stress produced typical gastric lesions in all rats of the stressed groups, but he number of ulcers as well as the mean ulcer diameter were reduced by 120 Hz EA pre-treatment. The cold-restraint stress also induced an increase in catecholamine response involving epinephrine, norepinephrine and dopamine, but an slight decline were observed in EA pre-treated rats compared with cold-restrained rats. Results: The degranulation value of gastric mast cell was significantly higher in cold-restrained rats than in control ones. However, with the significant reduction of degranulation values of gastric mast cells in EA pre-treated rats compared with cold-restrained ones, $PGE_2$ content in the gastric mucosa of EA pre-treated rats was also different from that observed in cold-restrained rats. Cold-restraint stress induced an elevated mRNA expression of pro-inflammatory gene such as cyclooxygenases-2 and tumor necrosis factor(TNF)-${\alpha}$, but these expression were down-regulated in EA pre-treated rats. Immunohistochemecal analysis showed that while the inhibitory-${\kappa}B{\alpha}$ an TNF-${\alpha}$ immunoreaction in the surface epithelium of the stomach tended to increase, both reactions in the EA pre-treated rats showed similar pattern as observed in controls. Conclusions : These results suggest that 120 Hz EA may act as a therapeutical means for gastric mucosal damages through a activation of pituitary adrenal system. it could be concluded that 120 hz high frequency electroacupuncture affords a good protective potential against stress-induce gastrointestinal dysfunction.

  • PDF

Static Structural Analysis on the Mechanical behavior of the KALIMER Fuel Assembly Duct

  • Kim, Kyung-Gun;Lee, Byoung-Oon;Woan Hwang;Kim, Young ll;Kim, Yong su
    • Nuclear Engineering and Technology
    • /
    • v.33 no.3
    • /
    • pp.298-306
    • /
    • 2001
  • As fuel burnup proceeds, thermal gradients, differential swelling, and inter-assembly loading may induce assembly duct bowing. Since duct bowing affects the reactivity, such as long or short term power-reactivity-decrement variations, handling problem, caused by top end deflection of the bowed assembly duct, and the integrity of the assembly duct itself. Assembly duct bowing were first observed at EBR-ll in 1965, and then several designs of assembly ducts and core restraint system were used to accommodate this problem. In this study, NUBOW-2D KMOD was used to analyze the bowing behavior of the assembly duct under the KALIMER(Korea Advanced Liquid MEtal Reactor) core restraint system conditions. The mechanical behavior of assembly ducts related to several design parameters are evaluated. ACLP(Above Core Load Pad) positions, the gap distance between the ducts, and the gap distance between the duct and restraint ring were selected as the sensitivity parameter for the evaluation of duct deflection.

  • PDF

The Safety Assessment of Wheelchair Occupants in Road Passenger Vehicles with the Frontal Crash: a Computer Simulation (시뮬레이션 기법을 이용한 차량내 전동휠체어 탑승자의 전방 충돌시 안전에 관한 연구)

  • Lee, Young-Shin;Lee, Ki-Du;Lim, Hyun Kyoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.11 s.242
    • /
    • pp.1518-1526
    • /
    • 2005
  • With increasing need of transportation services for people with disabilities and the aged, wheelchairs are used as their assistive devices to participate in daily and recreational activities and as seats of motor vehicle. However, as wheelchairs are primarily designed fer mobility assistive devices, not for vehicle seats, wheelchair users may experience serious injury when they meet car crashes. To date, neither engineering guidance for a wheelchair mounting system on the vehicle floor nor safety assessment analysis by a car crash has been studied for the domestic users. In this paper, in accordance with the ANSVRESNA WC-19, a fixed vehicle mounted wheelchair occupant restraint system (FWORS), wheelchair integrated restraint system (WIRS), and wheelchair integrated x-bend restraint system (WIXRS) subjected to frontal impact (20 g, 48 U) were analyzed using compute. simulations for domestic users. We present surrogate wheelchair occupant safety by head injury criteria (HIC), motion criteria (MC), and combined injury criteria (CIC).

Evaluation of Models for Estimating Shrinkage Stress in Patch Repair System

  • Kristiawan, Stefanus A.
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.4
    • /
    • pp.221-230
    • /
    • 2012
  • Cracking of repair material due to restraint of shrinkage could hinder the intended extension of serviceability of repaired concrete structure. The availability of model to predict shrinkage stress under restraint condition will be useful to assess whether repair material with particular deformation properties is resistance to cracking or not. The accuracy in the prediction will depend upon reliability of the model, input parameters, testing methods used to characterize the input parameters, etc. This paper reviews a variety of models to predict shrinkage stress in patch repair system. Effect of creep and composite action to release shrinkage stress in the patch repair system are quantified and discussed. Accuracy of the models is examined by comparing predicted and measured shrinkage stress. Simplified model to estimate shrinkage stress is proposed which requires only shrinkage property of repair material as an input parameter.

A Study on the Air Travel Safety of Infants and Children (영유아 항공 여행 안전성에 관한 고찰)

  • Kim, Sun Ah;Choi, Youn Seo;Kim, Sun Ihee
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.26 no.3
    • /
    • pp.93-104
    • /
    • 2018
  • It is mandatory to use car seats for infants and children in the private vehicles in accordance with the traffic law of Korea. Recently, legislation has also been proposed to expand the use car seats to express and intercity buses. This reflects a growing consensus that mandatory infant and child car seats, both for private and commercial vehicles, are essential. However, Korean laws concerning infants and children on board aircraft allow parents or guardians to hold children under two years of age on their laps without any restraint devices. It is not possible for a parent to physically restrain an infant or child, especially during a sudden acceleration or deceleration, unanticipated or severe turbulence, or impact. The use of CRS provides an equivalent level of safety to infants and children as that afforded to adult passengers wearing seat belts. But there is no regulation even about Child Restraint Systems on board aircraft in Korea. To enhance their safety, infants and children should be restrained in an approved child restraint system that is appropriate to their weight and height. It is necessary to examine whether infants and children in flight can achieve the same level of safety as an adult.

The effect of Territorial Restraint in Food&Beverage Similar Brand Extension (외식 프랜차이즈 거래에서 지역제한(Territorial Restraint)이 가맹본사의 브랜드 확장에 미치는 영향)

  • Lim, Chae-Un;Lee, Joseph;Yi, Ho-Taek
    • Journal of Distribution Research
    • /
    • v.15 no.5
    • /
    • pp.217-235
    • /
    • 2010
  • In franchise industry, territorial restraint is a system that imposes exclusive right to franchisers in a certain business area. To the franchisers, this system guarantees monopoly profits in a local market and exclusive rights during the contract periods. In such a way, franchisee generates a big revenue at once on the basis of franchiser's initial investment such as interior cost and franchise fee, it must have supervised franchiser's moral hazard for the territorial restraint agreement. Rather than territorial restraint can be a system to give exclusive right to franchiser's so that they neglect their own sales and too much rely on headquarter's brand and marketing activities without their own efforts. This paper assesses the implication of territorial restraint by examining the effect on brand extension, degree of contract termination. Drawing on research in transaction cost agreement and opportunism, the authors suggest that franchisee is highly likely to launch similar brand which is not effected on previous contract when territorial restraint is set out in the contract system. Moreover, the authors find that the degree of contract termination will be high in the existence of territorial restraint due to the franchisee's opportunism. The results imply that territorial restraint induces franchisee's opportunistic strategy more aggressively so that the possibility of brand extension or new brand launching will be increased. At the same time, franchisee is aggressively seeking for the reason for contract termination due to the pursuit of its profit maximization. Based on some empirical findings, this paper concludes with policy implications and some necessary fields of future studies desirable.

  • PDF

Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture (손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스)

  • Jang, Ik-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

INJURY PERFORMANCE EVALUATION OF THE CHILD RESTRAINT SYSTEMS

  • Shin, Y.J.;Kim, H.;Kim, S.B.;Kim, H.Y.
    • International Journal of Automotive Technology
    • /
    • v.8 no.2
    • /
    • pp.185-191
    • /
    • 2007
  • The new FMVSS 208, 213, 225 regulations include automatic suppression of airbags to prevent low-risk airbag deployment and the use of child seats with a rigid-bar anchor system. The regulations mean that children must sit in the rear seat, but do not include other specific safety measures for their protection. In the rear, restraint equipment consists of three-point shoulder/lap belts for the outside seats and a static two-point lap belt in the middle, with no additional devices such as pretensioners or load limiters; this is far from optimal for children. This study investigated injury rates using a 3-year-old-child dummy. ECE R44 sled tests used a booster, a speed of 48 km/h, and a 26- to 32-g rectangular deceleration pulse. While seated on a booster, the dummies were restrained by an adult shoulder/lap three-point belt. HIC_15 msec, Chest G and Nij were somewhat lower with an emergency locking retractor (ELR)+pretensioner+load limiter than with only an ELR or with ELR+pretensioner. However, the current seat-belt system results in injury rates that exceed the limit for OOP performance under the new FMVSS 208 regulations.