• Title/Summary/Keyword: system of radiological protection

Search Result 87, Processing Time 0.026 seconds

A Study on Mice Exposure Dose for Low-dose Gamma-irradiation Using Glass Dosimeter (유리선량계를 이용한 저선량 방사선의 마우스 피폭선량 연구)

  • Noh, Sung Jin;Kim, Hyo Jin;Kim, Hyun;Jeong, Dong Hyeok;Son, Tae Gen;Kim, Jung Ki;Yang, Kwangmo;Nam, Sang-Hee;Kang, Yeong-Rok
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.202-210
    • /
    • 2015
  • The low dose radiation is done for a long period, thus researchers have to know the exact dose distribution for the irradiated mouse. This research has been conducted in order to find out methods in transmitting an exact dose to mouse in a mouse irradiation experiment carried out using $^{137}Cs$ irradiation equipment installed in the DIRAMS (Dongnam Institution of Radiological & Medical Sciences) research center. We developed a single mouse housing cage and shelf with adjustable geometric factors such as distance and angle from collimator. The measurement of irradiated dose showed a maximal 42% difference of absorbed dose from the desired dose in the conventional irradiation system, whereas only 6% difference of the absorbed dose was measured in the self-developed mouse apartment system. In addition, multi mice housing showed much difference of the absorbed dose in between head and body, compared to single mouse housing in the conventional irradiation system. This research may allow further research about biological effect assessment for the low dose irradiation using the self-developed mouse apartment to provide more exact doses which it tries to transmit, and to have more reliability for the biological analysis results.

A Rapid Dose Assessment and Display System Applicable to PWR Accident (선량평가 및 Display시스템)

  • Moon, Kwang-Nam;Yook, Chong-Chul
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.67-77
    • /
    • 1988
  • The necessity of developing a rapid dose assessment system has been emphasized for an effective emergency response of mitigation of off-site radiological consequences. A microcomputer program based on a rapid dose assessment model of the off-site radiological consequences is developed for various accdident sinarios for the Nuclear Power Plants in Korea. This model, which is consists of the user answering-question input format as a menu driven method and the output format of table and graphic types, is helpful to decision-making on Emergency Preparedness by being more rapidly able to implement the off-site dose assessment and to interpret the result.

  • PDF

Age-Specific Thyroid Internal Dose Estimation for Koreans

  • Kwon, Tae-Eun;Yoon, Seokwon;Ha, Wi-Ho;Chung, Yoonsun;Jin, Young Woo
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.170-177
    • /
    • 2021
  • Background: The International Commission on Radiological Protection is preparing to provide reference dose coefficients for environmental radioiodine intake based on newly developed age-specific biokinetic models. However, the biokinetics of iodine has been reported to be strongly dependent on the dietary intake of stable iodine; for example, the thyroidal uptake of iodine may be substantially lower in iodine-rich regions than in iodine-deficient regions. Therefore, this study attempted to establish a system of age-specific thyroid dose estimation for South Koreans, whose daily iodine intakes are significantly higher than that of the world population. Materials and Methods: Korean age-specific biokinetic parameters and thyroid masses were derived based on the previously developed Korean adult model and the Korean anatomical reference data for adults, respectively. This study complied with the principles used in the development of age-specific biokinetic models for world population and used the ratios of baseline values for each age group relative to the value for adults to derive age-specific values. Results and Discussion: Biokinetic model predictions based on the Korean age-specific parameters showed significant differences in iodine behaviors in the body compared to those predicted using the model for the world population. In particular, the Korean age-specific thyroid dose coefficients for 129I and 131I were considerably lower than those calculated for the world population (25%-76% of the values for the world population). Conclusion: These differences stress the need for Korean-specific internal dose assessments for infants and children, which can be achieved by using the data calculated in this study.

Evaluation of Internal Dosimetry according to Various Radionuclides Conditions in Nuclear Medicine Myocardial Scan: Monte Carlo Simulation (심근 핵의학 검사에서 다양한 방사성핵종 조건에 따른 내부피폭선량 평가: 몬테카를로 시뮬레이션)

  • Min-Gwan Lee;Chanrok Park
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.213-218
    • /
    • 2024
  • The myocardial nuclear medicine examination is widely performed to diagnose myocardium disease using various radionuclides. Although image quality according to radionuclides has improved, the radiation exposure for target organ as well as peripheral organs should be considered. Here, the aim of this study was to evaluate absorbed dose (Gy) for peripheral organs in myocardial nuclear medicine scan from myocardium according to various scan environments based on Monte Carlo simulation. The simulation environment was modeled 5 cases, which were considered by radionuclides, number of injections, and radiodosage. In addition, the each radionuclide simulation such as distribution fraction was considered by recommended standard protocol, and the mesh computational female phantom, which is provided by International Commission on Radiological Protection (ICRP) 145, was used using the particle and heavy ion transport code system (PHITS) version 3.33. Based on the results, the closer to the myocardium, the higher the absorbed dose values. In addition, application for dual injection for radionuclides leaded to high absorbed dose compared with single injection for radionuclide. Consequently, there is difference for absorbed dose according to radionuclides, number of injections, and radiodosage. To detect the accurate diseased area, acquisition for improved image quality is crucial process by injecting radionuclides, however, we need to consider absorbed dose both target and peripheral inner organs from radionuclides in terms radiation protection for patient.

A Source-Related Approach for Discussion on Using Radionuclide-Contaminated Materials in Post-accident Rehabilitation

  • Kazuji Miwa;Takeshi Iimoto
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.2
    • /
    • pp.68-76
    • /
    • 2023
  • Background: In the process of discussion on the possibility of using radionuclide-contaminated soil and debris generated by radiation disasters, a strategy for the proper management of radiation exposure protection while considering the source of the contaminated materials is necessary. Materials and Methods: The radiological protection criteria that are likely to be applied to the source-related approach based on the International Commission on Radiological Protection recommendations and the International Atomic Energy Agency safety standards are summarized. We proposed five interpretations of radiation protection to contribute to the promotion of discussion on the possibility of using a part of low-level-radionuclide-contaminated soil and debris in the post-accident rehabilitation. Interpretations I to III are based on the idea of "using a reference level to protect the public in post-accident rehabilitation," whereas IV and V are based on the idea of "using the dose constraint to protect the public in the post-accident rehabilitation when the sources are handled in a planned activity." The former idea is subdivided into three based on the definition of the source, which is managed by the reference level, and the latter idea is divided into two depending on whether or not additional dose from using contaminated materials is deemed acceptable. Results and Discussion: To confirm the applicability of the five interpretations presented, we suggested the concrete values of protection criteria via two feasible cases. In this case study, we proposed radiation protection by the dose constraint based on the Interpretation IV and chose 1 mSv/yr for the public and 20 mSv/yr for workers dealing with radionuclide-contaminated materials. Conclusion: We concretely and systematically demonstrated how the concept of radiation protection can be applied to the process of discussion on the possibility of using radionuclide-contaminated materials within the framework of an international system of protection. This study's findings can provide necessary information to discuss the possibility of using radionuclide-contaminated materials as an alternative option for recovery and reconstruction after a radiation disaster from the viewpoint of radiation protection.

Comparison of Dosimetric Parameters Based on Beam Arrangement Changes in HA-WBRT by Using VMAT Technique: A Phantom Study (VMAT 기법을 활용한 HA-WBRT에서 빔 배열 변화에 따른 선량학적 인자 비교: 팬텀 연구)

  • Sung-Kuk Park;Dong-Hyun Kim
    • Journal of radiological science and technology
    • /
    • v.47 no.4
    • /
    • pp.271-278
    • /
    • 2024
  • This study aimed to evaluate the impact of changes in beam arrangement and arc counts on dosimetric factors in volumetric modulated arc therapy (VMAT) inverse radiation therapy planning for hippocampal-avoidance whole brain radiation therapy (HA-WBRT) by using the Elekta Monaco radiation therapy planning system (RTPs). For coplanar VMAT, both the arc per beam (APB) method and the beam determined arc(BDA) method, which is determined by the number of beams, were applied. For non-coplanar VMAT, the BDA method was utilized, and a total of 9 treatment plans were established by varying the arc counts. All radiation therapy plans met the radiation oncology group (RTOG) 0933 protocol standards, and 14 dosimetric factors were compared and analyzed. The results showed that the BDA-NC VMAT method demonstrated superior performance in terms of planning target volume (PTV) coverage and protection of normal organs, while APB-VMAT was advantageous in terms of hippocampal protection, monitor unit and delivery time. This study is expected to contribute to the efficient establishment of HA-WBRT plans considering the changes in beam arrangement and rotation arc numbers in Monaco RTPs.

Assessment of Applicability of Portable HPGe Detector with In Situ Object Counting System based on Performance Evaluation of Thyroid Radiobioassays

  • Park, MinSeok;Kwon, Tae-Eun;Pak, Min Jung;Park, Se-Young;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.2
    • /
    • pp.83-90
    • /
    • 2017
  • Background: Different cases exist in the measurement of thyroid radiobioassays owing to the individual characteristics of the subjects, especially the potential variation in the counting efficiency. An In situ Object Counting System (ISOCS) was developed to perform an efficiency calibration based on the Monte Carlo calculation, as an alternative to conventional calibration methods. The purpose of this study is to evaluate the applicability of ISOCS to thyroid radiobioassays by comparison with a conventional thyroid monitoring system. Materials and Methods: The efficiency calibration of a portable high-purity germanium (HPGe) detector was performed using ISOCS software. In contrast, the conventional efficiency calibration, which needed a radioactive material, was applied to a scintillator-based thyroid monitor. Four radioiodine samples that contained $^{125}I$ and $^{131}I$ in both aqueous solution and gel forms were measured to evaluate radioactivity in the thyroid. ANSI/HPS N13.30 performance criteria, which included the relative bias, relative precision, and root-mean-squared error, were applied to evaluate the performance of the measurement system. Results and Discussion: The portable HPGe detector could measure both radioiodines with ISOCS but the thyroid monitor could not measure $^{125}I$ because of the limited energy resolution of the NaI(Tl) scintillator. The $^{131}I$ results from both detectors agreed to within 5% with the certified results. Moreover, the $^{125}I$ results from the portable HPGe detector agreed to within 10% with the certified results. All measurement results complied with the ANSI/HPS N13.30 performance criteria. Conclusion: The results of the intercomparison program indicated the feasibility of applying ISOCS software to direct thyroid radiobioassays. The portable HPGe detector with ISOCS software can provide the convenience of efficiency calibration and higher energy resolution for identifying photopeaks, compared with a conventional thyroid monitor with a NaI(Tl) scintillator. The application of ISOCS software in a radiation emergency can improve the response in terms of internal contamination monitoring.

Development of Meteorological Data Acquisition and Meteorological Information Processing System for the Analysis of Radionuclide Behavior in the Atmosphere (방사성물질의 대기중 거동해석을 위한 기상정보인지 및 처리시스템 개발)

  • Kim, Eun-Han;Hwang, Won-Tae;Suh, Kyung-Suk;Han, Moon-Hee;Kim, Byung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.117-122
    • /
    • 1995
  • Meteorological Data Acquisition System (MDAS) and Meteorolocical Information Processing System (MIPS) have been developed for the measurement of the meteorological parameters at the Korea Atomic Energy Research Institute site. MIPS represents the measured meteorological data graphically on a computer screen. MDAS and MIPS are interfaced with real-time radiological dose assessment system (FADAS), which has been developed to rapidly assess the radiological consequences and to support decision-making under radiological emergencies.

  • PDF

Consideration about Radiological Technology Student's Frequent Workers Exposure Dose Rate (방사선과 재학생의 수시출입자 방사선 피폭선량에 대한 고찰)

  • Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.573-580
    • /
    • 2018
  • The Nuclear Safety Commission amended the Nuclear Safety Act by strengthening the safety management system for the frequent workers to the level of radiation workers. And students entering radiation management zones for testing and practical purposes are subject to frequent workers. It is inevitable that this will incur additional costs. In this paper, the validity of the amendment to the Nuclear Safety Act was to be assessed in terms of radiation protection. Study subjects are from 2014 to 2016, among university students in Seong-nam Korea and comparisons for analyses were made taking into account variables that are differences in annual, practical types, on-class and clinical practice students exposure dose. The analysis showed that exposures between on-class and clinical practice received were less than the annual dose limit of 1 mSv for the public. Then, some alternatives that excluding from frequent workers during on-class practice or mitigating the frequent workers' safety regulation for only on-class frequent workers can be considered. Optimization is how rational is the reduction in exposure dose to the costs required. Therefore, the results are hardly considered for optimization. If the data accumulated, it could be considered that the revision of the act could be evaluated and improved.

Exoskeleton System for Radiation Protection in Interventional Radiology

  • Clarissa Hosse;Johannes Kolck;Elif Can;Uli Fehrenbach;Timo A. Auer;Fabio Pivetta;Federico Collettini;Bernhard Gebauer;Maximilian de Bucourt
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.2
    • /
    • pp.78-84
    • /
    • 2024
  • Background: As the quantity and complexity of radiological interventions are constantly increasing, gear that offers optimal protection while maintaining mobility and a low weight burden is becoming more important. A newly developed exoskeleton radiation protection system (ERPS) (StemRad MD; StemRad Ltd.) can carry the weight of the shielding. The aim of our study was to analyze initial experience, especially in terms of advantages and disadvantages, with this new ERPS in interventional radiology. Materials and Methods: Forty-six interventions utilizing the ERPS were analyzed. The interventional radiologists completed a 15-question survey evaluating various aspects of the protective system, including weight, mobility, comfort, and radiation protection adequacy. Results and Discussion: In 98% of procedures, interventionalists reported being very satisfied (89%) or slightly satisfied (9%) and would recommend the system to colleagues. The exoskeleton system was rated as 100% comfortable, not too heavy, and did not restrict mobility in 98% of cases. Conclusion: The ERPS is a recommendable alternative to standard lead aprons, providing flexibility, comfort, and effective weight distribution without restricting mobility.