• Title/Summary/Keyword: system closure

Search Result 362, Processing Time 0.028 seconds

Drowsiness-drive Perception System Using Vision (비젼을 이용한 졸음운전 감지 시스템)

  • Joo, Young-Hoon;Kim, Jin-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2281-2284
    • /
    • 2008
  • The purpose of this paper is to develope the drowsiness-drive perception system which judges drowsiness driving based on drivers' eye region using single vision system. To do this, first, we use the Haar-like feature and AdaBoost learning algorithm for detecting the features of the face region. And we measure the eye blinking frequency and eye closure duration from these feature data. And then, we propose the drowsiness-drive detection algorithm using the eye blinking frequency and eye closure duration. Finally, we have shown the effectiveness and feasibility of the proposed method through some experiments.

Seepage Velocity and Borehole Image of Bottom Protection Layer Filled with Dredged Sand in Sea Dyke (준설해사로 충진된 바닥보호공의 형상 및 침투유속평가)

  • Oh, Young-In;Kang, Byung-Yoon;Kim, Ki-Nyeon;Cho, Young-Gwon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1727-1734
    • /
    • 2008
  • After the final closure of sea dyke, seepage behaviour of embankment is highly changed by variation of water head different between tide wave and controlled water level at fresh lake. Especially, the seepage behaviour of bottom protection layer of final closure section is more important factor for structural and functional stability of sea dyke, because of the bottom protection layer of final closure section is penetrated sea side to fresh lake. Even though bottom protection layer was filled with dredged fine sand, it has a high permeability. In this paper, mainly described about the seepage velocity and borehole image of bottom protection layer filled with dredged sand after final closure. Various in-situ tests such as BIPS (Borehole Image Processing System) and ABI (Acoustic Borehole Imager) survey, wave velocity measuring, and color tracer survey were conducted to evaluate the seepage behavior of bottom protection layer. Based on the in-situ tests, the bottom protection layer of final closure section was almost filled with dredged sand which is slightly coarse grain sand and there have sea water flow by water head different between tide wave and controlled water level at fresh lake. Also, comply with tracer survey results, the sea water flow path was not exist or generated in the bottom protection layer. However, because of this result not only short term survey but also just one test borehole survey results, additional long term and other borehole tests are needed.

  • PDF

The maximum phonation time and temporal aspects in Korean stops in children with spastic cerebral palsy (경직형 뇌성마비 아동의 최대 발성지속시간과 파열음 산출 시 조음시간 특성 비교)

  • Jeong, Jin-Ok;Kim, Deog-Yong;Sim, Hyun-Sub;Park, Eun-Sook
    • Phonetics and Speech Sciences
    • /
    • v.3 no.1
    • /
    • pp.135-143
    • /
    • 2011
  • This study evaluated the respiratory capacity of spastic cerebral palsy children who were grouped by GMFCS (Gross Motor Function Classification System) levels and identified the acoustic characteristics of three different types of Korean stops (stop consonants) which are needed for the temporal coordination of larynx and supra-larynx, in these children. Thirty-two children with dysarthria due to spastic cerebral palsy were divided into two subgroups: 14 children classified at GMFCS levels I~III were placed in Group 1 and 18 classified at GMFCS levels IV~V were placed in Group 11, and 18 children with normal speech were selected and placed in the control group. /a/ pronged phonation (sustained vowel /a/) and nine Korean VCV syllables were used. Examined acoustic characteristics were maximum phonation time (MPT) and closure duration and aspiration duration. The results were as follows: 1) The MPTs of the cerebral palsy (CP) groups, both Group I and Group II, were significantly shorter than those of the normal group. 2) The closure durations of the two CP groups were longer than those of the normal group for all 9 target syllables. 3) The aspiration durations of the two CP groups were longer than those of the normal group. 4) The closure duration of the normal and CP Group I was significantly different among tense, aspirated, and lax. However, the CP Group II was different from normal. 5) The aspiration duration of the normal and CP Group I was significantly different among aspirated, tense, and lax. However, the CP Group II was different from normal. 6) The place of articulation influenced less than the manner of articulation on closure and aspiration duration.

  • PDF

Delayed Sternal Closure Using a Vacuum-Assisted Closure System in Adult Cardiac Surgery

  • Hyun Ah Lim;Jinwon Shin;Min Seop Jo;Yong Jin Chang;Deog Gon Cho;Hyung Tae Sim
    • Journal of Chest Surgery
    • /
    • v.56 no.3
    • /
    • pp.206-212
    • /
    • 2023
  • Background: Delayed sternal closure (DSC) is a useful option for patients with intractable bleeding and hemodynamic instability due to prolonged cardiopulmonary bypass and a preoperative bleeding tendency. Vacuum-assisted closure (VAC) has been widely used for sternal wound problems, but only rarely for DSC, and its efficacy for mediastinal drainage immediately after cardiac surgery has not been well established. Therefore, we evaluated the usefulness of DSC using VAC in adult cardiac surgery. Methods: We analyzed 33 patients who underwent DSC using VAC from January 2017 to July 2022. After packing sterile gauze around the heart surface and great vessels, VAC was applied directly without sternal self-retaining retractors and mediastinal drain tubes. Results: Twenty-one patients (63.6%) underwent emergency surgery for conditions including type A acute aortic dissection (n=13), and 8 patients (24.2%) received postoperative extracorporeal membrane oxygenation support. Intractable bleeding (n=25) was the most common reason for an open sternum. The median duration of open sternum was 2 days (interquartile range [25th-75th pertentiles], 2-3.25 days) and 9 patients underwent VAC application more than once. The overall in-hospital mortality rate was 27.3%. Superficial wound problems occurred in 10 patients (30.3%), and there were no deep sternal wound infections. Conclusion: For patients with an open sternum, VAC alone, which is effective for mediastinal drainage and cardiac decompression, had an acceptable superficial wound infection rate and no deep sternal wound infections. In adult cardiac surgery, DSC using VAC may be useful in patients with intractable bleeding or unstable hemodynamics with myocardial edema.

A study on stresses and displacements of the ground according to the closure ratio of tunnel face during tunnel excavation (터널 막장폐합비에 따른 지반 응력 및 침하량에 대한 연구)

  • Kim, Sang-Hwan;Min, Byeong-Heon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.5
    • /
    • pp.369-378
    • /
    • 2010
  • This paper presents a new approach of closing the tunnel face with sprayed concrete to reduce the stress at the tunnel face and displacement occurring at the ground surface during tunnel excavation. In order to carry out this research, the experimental and numerical studies are performed. In the experimental study, the model tests are carried out according to the closure ratio of tunnel face, tunnel depth and tunnel excavation length. The model test results are analyzed and interpreted by numerical calculation in order to verify both results obtained from experimental and numerical studies. It is clearly found that the tunnel face stability is decreased in decreasing the closure ratio of tunnel face. The results also show that the tunnel face is stable when the closure ratio of tunnel face is larger than 80%. This research will be very useful to develop the economical tunnel face closing system.

Calculation of Probability of System Failure for Pipe Network with Surge Tank regarding Unsteady Flow (Surge Tank가 설치된 상수도관망에서 부정류를 고려한 불능확률 산정)

  • Kwon, Hyuk Jae;Lee, Cheol-Eung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.295-303
    • /
    • 2009
  • In the present study, a reliability analysis calculating the probability of system failure has been performed using cut set and results of numerical analysis for unsteady flow in pipe. Especially, the probability of system failure has been evaluated regarding the effect of valve closure which is a really important activity in operation of piping system. In spite of small amount of demand, it was found that fast valve closure can generate high probability of system failure. Furthermore, it was confirmed that surge tank can reduce the unsteady effects and probability of system failure in water distribution system. From the results, it was found that the unsteady flow has a significant effect on the probability of system failure Furthermore, it was able to find which pipe or cut set has high probability of system failure. So it could be used to determine which pipe or cut set has a priority of repair and replacement. Therefore, reliability analysis regarding unsteady flow has to be performed for the planning, designing, maintenance, and operation of piping system.

A Case of Intramuscular Abscess in the Sternocleidomastoid Muscle after Intramuscular Stimulation (IMS) (근육내 자극요법 후 목빗근내 농양의 치험례)

  • Kim, Jae-In;Choi, Hwan-Jun;Choi, Chang-Yong;Yang, Hyung-Eun
    • Archives of Plastic Surgery
    • /
    • v.37 no.2
    • /
    • pp.182-186
    • /
    • 2010
  • Purpose: Intramuscular stimulation (IMS) shows good results in the treatment of chronic pain patients who did not respond to other treatments such as oral analgesics, trigger point injection, nerve block and epidural steroid injection. But, IMS procedure especially, patients with diabetes mellitus (DM) has sometimes serious problem. So, we present a very rare case of intramuscular abscess in the sternocleiomastoid muscle after IMS with literature review. Methods: A 66 year old male visited our department 7 days after IMS in the neck. His premorbid conditions and risk factors of deep neck infection was DM and old age. Computed tomographic scans of the head and neck region were performed in this patient: signs of deep neck infection, were seen enhanced abscess in the sternocleidomastoid muscle, cellulitis overlying tissue of the neck, and air bubbles involved muscle. Necrotic wound was excised serially and we treated this with the Vacuum-assisted closure (VAC, Kinetics Concepts International, San Antonio, Texas) system device. After appropriately shaping the sponge in the pockets, continuous negative pressure of 125 mmHg was applied. The VAC therapy was utilized for a period of 12 days. Results: We obtained satisfactory results from wide excision, drainage of the abscess with the VAC system, and then primary closure. The postoperative course was uneventful. Results: We suggest that many of the infectious complications may be preventable by strict adherence to aseptic techniques and that some of the other complications may be minimized by refining the techniques with a clear understanding of the medical disorders of patients. And, the refined technique using the VAC system can provide a means of simple and effective management for the cervical intramuscular abscess, with better cosmetic and functional results.

The Effect of Air Chamber Placed in Water Supply Piping System (급수배관계에서 에어 챔버의 설치효과에 관한 연구)

  • 이용화;최국광
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1047-1055
    • /
    • 2002
  • The present study is to investigate the pressure wave characteristics and the absorption of the maximum and minimum pressure generated by instantaneous valve closure and opening at the end of the straightening copper Piping system with and without an air chamber. Also, life of air chamber is investigated. Experiments were conducted under the following conditions: initial pressure of 1~5 bar, flow velocity of 0.5~3.0 m/s, water temperature of$20^{\circ}C$ and air chamber volume of 45.1~449.5$cm^3$ The results of the study can be used in sizing air chamber and selecting the water hammer absorbtion apparatus.

Modal Interactions in an Autoparametric Vibration Absorber to Narrow Band Random Excitation

  • Cho, Duk-Sang;Mo, Chang-Ki;Ban, Gab-Su;Lee, Kwang-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.97-104
    • /
    • 2003
  • The main objectives of this study are to examine the random responses of a vibration absorber system with autoparametric coupling in the neighborhood of internal resonance subjected to narrow band random excitation by Gaussian closure scheme and to compare the results with those obtained by Monte Carlo simulation. The Monte Carlo simulation is found to support the main features of the nonlinear modal interaction in the neighborhood of internal resonance conditions. The jump phenomenon of the cantilever mode and saturation phenomenon of the main system are shown to occur if the excitation bandwidth is sufficiently small.

THE WEAK F-REGULARITY OF COHEN-MACAULAY LOCAL RINGS

  • Cho, Y.H.;Moon, M.I.
    • Bulletin of the Korean Mathematical Society
    • /
    • v.28 no.2
    • /
    • pp.175-180
    • /
    • 1991
  • In [3], [4] and [5], Hochster and Huneke introduced the notions of the tight closure of an ideal and of the weak F-regularity of a ring. This notion enabled us to give new proofs of many results in commutative algebra. A regular ring is known to be F-regular, and a Gorenstein local ring is proved to be F-regular provided that one ideal generated by a system of parameters (briefly s.o.p.) is tightly closed. In fact, a Gorenstein local ring is weakly F-regular if and only if there exists a system of parameters ideal which is tightly closed [3]. But we do not know whether this fact is true or not if a ring is not Gorenstein, in particular, a ring is a Cohen Macaulay (briefly C-M) local ring. In this paper, we will prove this in the case of an 1-dimensional C-M local ring. For this, we study the F-rationality and the normality of the ring. And we will also prove that a C-M local ring is to be Gorenstein under some additional condition about the tight closure.

  • PDF