• Title/Summary/Keyword: system bus

Search Result 2,315, Processing Time 0.031 seconds

Stabilization of nonlinear two-generator five-bus power systems using fuzzy control (퍼지제어를 이용한 비선형 2기 5모선 전력계통의 안정화)

  • Moon, Un-Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.1
    • /
    • pp.42-49
    • /
    • 2000
  • This paper presents the application of a FARMA controller to stabilization of nonlinear Two-Generator Five-Bus power Systems. The control rules and the membership functions of the FARMA controller are generated automatically without using any plant model high complexity and severe nonlinearity of power systems are introduced and two-Machine Five -Bus Power system stabilization problem is formulated. The simulation results demonstrate the effectiveness and application possibility of the FARMA controller to the control problem of high order and nonlinear plants.

  • PDF

The PI control of the Voltage Bus Conditioner for the improvement of the Power Quality in the DC Power Distribution System with multiple parallel loads (다중 병렬 부하를 가지는 DC 배전 시스템에서의 전력 품질 향상을 위한 Voltage Bus Conditioner의 PI 제어)

  • Lee, Byung-Hun;Woo, Hyun-Min;La, Jae-Du;Shin, Jae-Hwa;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1234-1235
    • /
    • 2011
  • A DC Power Distribution Systems(DC PDS) are widely used in telecommunication system, electric vehicle, aircraft, military system, etc. In the DC PDS, DC bus voltage instability may be occurred by the operation of multiple loads such as pulsed power load, motor drive system, and constant power loads. To damp the transients of the DC bus voltage, the Voltage Bus Conditioner(VBC) with the PI compensator is used. In this paper, the validity of the proposed VBC system is verified by PSIM simulation package.

  • PDF

Low-Power Bus Architecture Composition for AMBA AXI

  • Na, Sang-Kwon;Yang, Sung;Kyung, Chong-Min
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.2
    • /
    • pp.75-79
    • /
    • 2009
  • A system-on-a-chip communication architecture has a significant impact on the performance and power consumption of modern multi-processors system-on-chips (MPSoCs). However, customization of such architecture for a specific application requires the exploration of a large design space. Thus, system designers need tools to rapidly explore and evaluate communication architectures. In this paper we present the method for application-specific low-power bus architecture synthesis at system-level. Our paper has two contributions. First, we build a bus power model of AMBA AXI bus communication architecture. Second, we incorporate this power model into a low-power architecture exploration algorithm that enables system designers to rapidly explore the target bus architecture. The proposed exploration algorithm reduces power consumption by 20.1% compared to a maximally connected reduced matrix, and the area is also reduced by 20.2% compared to the maximally connected reduced matrix.

Analysis of the Air-flow for Natural Ventilation of Express Bus (고속버스 자연환기구의 기류패턴 분석)

  • Yoo, Ho-Chun;Noh, Kyoung-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.336-341
    • /
    • 2009
  • In express bus which has no window, the air quality inside the bus is very critical for the passengers who staying for an extended time. Air conditioning system using natural energy is expected to significantly improve the air quality while the bus runs the suburban area. But the express buses today usually attempt to ventilate using air conditioning system, rather than natural ventilation. In this study, analysis of existing ventilation opening and the new ventilation system on roof, using computer simulation. As a result, two cases using existing ventilation device was found to be effective for partial ventilation only, while the air in front remains standstill. The new system proved to have promoted more dynamic ventilation in most of space.

  • PDF

Development of Bus Load Forecasting System based on Windows95 : Part I (윈도우즈95에 기초한 모선수요예측시스템의 개발(I))

  • Jeon, Dong-Hoon;Song, Seok-Ha;Lim, Joo-Il;Hwang, Kab-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.169-171
    • /
    • 1996
  • In this paper, we have developed bus load forecasting system (BUSLOF) based on Windows 95. It has been developed for the secure operation of electric power system. It forecasts regional load and bus load using regional distribution factor(RDF) and bus distribution factor (BDF) which are calculated from bus load in the past. It is equipped with graphic user interface(GUI) which enables a user to easily access to the system. The performance of the developed system is estimated in sample data.

  • PDF

Cause Analysis and Improvement of Signal Interference in Byteflight Data Bus

  • Kwon, Jung-Hyuk;Tak, Su-Pyeong;Kwon, Ik-Hyun;Lee, Wang-Sang
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.6
    • /
    • pp.50-58
    • /
    • 2021
  • Byteflight is developed based on RS-485 communication (an international standard), and it can be used as a data bus during the operation of an integrated avionics system in the latest aircraft. Therefore, the integrated avionics system can perform an effective and safe flight mission only when the accurate and seamless display of flight information, communication, and accurate functions of navigation are implemented. In this study, cause analysis and failure investigation were performed on screen abnormalities and communication interruptions due to signal interference in the Byteflight data bus of the integrated avionics system during aircraft operation. To improve signal interference between avionics units, the branch point and wiring path of the Byteflight data bus were changed, and the verification result of the improved method was also described.

A Development of Punctuality Index for Bus Operation Using Time-space Diagram (시공도를 이용한 버스운행 정시성 지표개발)

  • Yang, Ji-Young;Kim, Young-Chan;Kim, Seung-Il
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.8 s.86
    • /
    • pp.129-138
    • /
    • 2005
  • Since Successive introduction of BMS(Bus Management System) into the local governments has been able to collect each bus data on the road and valuate the bus operation by the quantitative index not qualitative index. we need a study on punctuality index for evaluation of service level for bus operation using bus location information. We propose punctuality index for bus operation using time-space diagram and valuate the index by application to real bus data.

Load Center Concept Equivalent by T/L Loss Identification (부하 중심점 개념의 전력 시스템 정태 등가 축약)

  • Baek, Soo-Youl;Kim, Jung-Hun;Shim, Keon-Bo;Lee, Bong-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.149-152
    • /
    • 1992
  • A simple and practial equivalent technique has been presented in this study. Arbitrary number of bus system can be aggregated to the equivalent one-bus system, equivalents are totel real, and reactive bus powers and T/L losses viewing form boundary buses. Variables to be determined are line impedance between boundary buses and the equivalent bus, voltage and angle of that bus. IEEE 14 bus system is used to demonstrate the proposed method. even in contingency cases very good results have been obtained

  • PDF

Current Sensorless Control of the Voltage Bus Conditioner for a DC Power System with Parallel Pulsed Power Loads (병렬 펄스 부하를 갖는 직류 전력시스템을 위한 Voltage Bus Conditioner의 전류 센서 없는 제어)

  • Lee, Byung-Hun;Chang, Han-Sol;La, Jae-Du;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1617-1624
    • /
    • 2012
  • A DC power system has many loads with varied functions. Also, there may be large pulsed loads with short duty ratios which can affect the normal operation of other loads. In this paper, Voltage Bus Conditioner(VBC) without any current sensors is proposed to damp the bus voltage transients by parallel pulsed loads. The proposed control approach requires only one voltage sensor and carries out both the functions of damping the bus voltage transients and maintaining the level of energy stored. The proposed control technique has been implemented on a TMS320F2812 Digital Signal Processor(DSP). Simulated results by a Matlab Simulink and experimental results are presented which verify the control principles and demonstrate the practicalty of the approach.

An Overload Alleviation Algorithm by Line Switching (선로절환에 의한 과부화 해소 앨고리즘)

  • 박규홍;정재길
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.5
    • /
    • pp.459-467
    • /
    • 1992
  • This paper presents a new algorithm for the countermeasure to alleviate the line overloads due to contingency without shedding loads in a power system. This method for relieving the line overloads by line switching is based on obtaining the kine outage distribution factors-the linear sensitivity factors, which give the amount of change in the power flow of each line due to the removal of a line in a power system. There factors are made up of the elements of sparse bus reactance matrix and brach reactances. In this paper a fast algorithm and program is presented for obtaining only the required bus reactance elements which corresponds to a non-zero elements of bus admittance matrix, and elements of columns which correspond to two terminal buses of the overloaded(monitored) line. The proposed algorithm has been validated in tests on a 6-bus and the 30-bus test system.

  • PDF