• Title/Summary/Keyword: synthetic zeolite

Search Result 84, Processing Time 0.027 seconds

Measurement of Oxygen Saturation Concentration by Zeolite (제올라이트별 산소포화농도 측정 실험)

  • Park, Sung-Sik;Kim, Kwang-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.617-622
    • /
    • 2018
  • Air is essential for human beings to survive, but urban air is polluted with soot and harmful gases, due to the increase in industrial development and the population. Thus, air pollution in large cities is of increasing interest in the research community. One of the plausible solutions to this problem is supplying sufficient oxygen to indoor spaces. The main principle of the oxygen generator is to separate oxygen from air using synthetic zeolite. Various synthetic zeolites have been applied to public indoor spaces with the focus being placed on the oxygen exchange quality. Among the characteristics of zeolites which can be applied to oxygen generators is their ability to adsorb nitrogen from the air and, in this way, generate only oxygen. Thus, we investigated the degree of nitrogen adsorption by five kinds of natural zeolite and LTA zeolite 3A, 4A, and 5A (two different sizes). Using the PSA method, the higher the degree of nitrogen adsorption, the higher the oxygen saturation concentration, it was found that the nitrogen adsorption degree of the 5A zeolite was the highest. 6% on average. It was also found that the size of the zeolite had a significant effect on the degree of nitrogen adsorption.

Cu and Zn Ions Adsorption Properties at Various pH with a Synthetic Zeolite (합성 제올라이트를 이용한 pH에 따른 Cu와 Zn 이온의 흡착특성)

  • Lee, Chang-Han
    • Journal of Environmental Science International
    • /
    • v.21 no.7
    • /
    • pp.805-813
    • /
    • 2012
  • The removal property of Cu and Zn ions by chemical precipitation and adsorption using zeolite(Z-C1) prepared from coal fly ash(CFA) were evaluated in this study. Adsorption kinetic and equilibrium mechanisms described to analyze parameters and correlation factors with Lagergen $1^{st}$ and $2^{nd}$ order model and Langmuir and Freundlich model. Analysis of adsorption kinetics data revealed that the pseudo $2^{nd}$ order kinetics mechanism was predominant. The equilibrium data in pH 3 - 5 were able to be fitted well to a Langmuir model, by which the maximum adsorption capacities($q_{max}$) were determined at 124.9 - 140.1 mg $Cu^{2+}/g$ and 153.2 - 166.9 mg $Zn^{2+}/g$, respectively. We found that Z-C1 has a potential application as absorbents in metal ion recovery with low pH.

Adsorption Characteristics of Ammonia-Nitrogen by Zeolitic Materials Synthesized from Jeju Scoria (제주 스코리아로부터 합성한 제올라이트 물질에 의한 암모니아성 질소의 흡착 특성)

  • Lee, Chang-Han;Hyun, Sung-Su;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.29 no.12
    • /
    • pp.1261-1274
    • /
    • 2020
  • The characteristics of ammonia-nitrogen (NH4+-N) adsorption by a zeolitic material synthesized from Jeju scoria using the fusion and hydrothermal method was studied. The synthetic zeolitic material (Z-SA) was identified as a Na-A zeolite by X-ray diffraction, X-ray fluorescence analysis and scanning electron microscopy images. The adsorption of NH4+-N using Jeju scoria and different types of zeolite such as the Z-SA, natural zeolite, and commercial pure zeolite (Na-A zeolite, Z-CS) was compared. The equilibrium of NH4+-N adsorption was reached within 30 min for Z-SA and Z-CS, and after 60 min for Jeju scoria and natural zeolite. The adsorption capacity of NH4+-N increased with approaching to neutral when pH was in the range of 3-7, but decreased above 7. The removal efficiency of NH4+-N increased with increasing Z-SA dosage, however, its adsorption capacity decreased. For initial NH4+-N concentrations of 10-200 mg/L at pH 7, the adsorption rate of NH4+-N was well described by the pseudo second-order kinetic model than the pseudo first-order kinetic model. The adsorption isotherm was well fitted by the Langmuir model. The maximum uptake of NH4+-N obtained from the Langmuir model decreased in the order of Z-CS (46.8 mg/g) > Z-SA (31.3 mg/g) > natural zeolite (5.6 mg/g) > Jeju scoria (0.2 mg/g).

Gas Separations of Natural Zeolite by Chemical Treatments (화학처리에 의한 천연 Zeolite의 Gas 분리)

  • Im, Goeng
    • The Journal of Natural Sciences
    • /
    • v.5 no.1
    • /
    • pp.67-75
    • /
    • 1992
  • In the our country, especially in Yeongil and Wolsung area, abundant authigenic zeolites are found from the tuffaceous sediments and volcanic rocks of Miocene age showing wide variation in their mineralogy and abundance from horizon to horizon. The principal zeolite species identified are clinopti-lolite. mordenite. heulandite. ferrierite, and erionite. etc. Zeolite minerals are widely used in many countries in the following applications; (a) in air separation adsorption processes; (b)as desiccants; (c)in inorganic building materials; (d)in papermaking; (e)in fertilizers; (f)as soilconditioners-this application is based upon the ability of the zeolite to ion exchange with soil nutrients; (g)in the treatment of radioactive wastes; and (h)as adsorbents for toxic gases, etc. In the present paper, using natural zeolite mordenite treated with IN hydrochloric acid or IN sodium chloride solution as column packings, separation characteristics of argon, nitrogen, carbon monoxide, and methane gases have been studied by gas chromatography. By the use of mordenite treated with hydrochloric acid solution, the tailing peak of methane showed from untreated mordenite was satisfactorily reduced, although it was difficult to separate it from carbon monoxide with a column activated at $300^{\circ}C$. Using a column activated at $350^{\circ}C$, methane could be separated from carbon monoxide easily but only carbon monoxide eluted as a bad defined peak. Mordenite treated with sodium chloride solution was generally similar to chromatograms obtained by using the untreated mordenite. Both the above chemical treatments of mordenite had little effect on the separations of argon and nitrogen. The separations and the HETP values obtained from natural zeolite mordenite treated with continuously hydrochloric acid and sodium chloride solutions were almost identical with those obtained with synthetic molecular sieve 5A zeolite. On the other hand, the efficiency of column was good in the range 20~3Oml/min of the carrier helium gas rate.

  • PDF

Simultaneous dry-sorption of heavy metals by porous adsorbents during sludge composting

  • Ozdemir, Saim;Turp, Sinan Mehmet;Oz, Nurtac
    • Environmental Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.258-265
    • /
    • 2020
  • Heavy metal removal by using porous mineral adsorbents bears a great potential to decontaminate sludge compost, and natural zeolite (NZ), artificial zeolite (AZ), and expanded perlite (EP) seem to be possible candidates for this purpose. A composting experiment was conducted to compare the efficiency of those adsorbents for removal of iron (Fe), manganese (Mn), chromium (Cr), copper (Cu), zinc (Zn), nickel (Ni), and lead (Pb) from sewage sludge compost with no adsorbent amendment. For this purpose, 10 g of NZ and AZ and 5 g of EP was filled in a small bag made from non-biodegradable synthetic textile and was separately mixed in composting piles. The bags were separated from compost samples at the end of the experiment. AZ and NZ exhibited different reduction potentials depending on the type of heavy metal. AZ significantly reduced Cr (43.7%), Mn (35.8%), and Fe (29.9%), while NZ more efficiently reduced Cu (24.5%), Ni (22.2%), Zn (22.1%), and Pb (21.2%). The removal efficiency of EP was smaller than both AZ and NZ. The results of this simultaneous composting and metal removing study suggest that AZ and NZ can efficiently bind metal during composting process.

A Test of Relative Removal Properties of Various Offensive Odors by Zeolite

  • Adelodun, Adedeji A.;Vellingiri, Kowsalya;Jeon, Byong-Hun;Oh, Jong-Min;Kumar, Sandeep;Kim, Ki-Hyun
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.15-28
    • /
    • 2017
  • The adsorptive removal properties of synthetic A4 zeolite were investigated against a total of 16 offensive odors consisting of reduced sulfur compounds (RSCs), nitrogenous compounds (NCs), volatile fatty acids (VFAs), and phenols/indoles (PnI). Removal of these odors was measured using a laboratory-scale impinger-based adsorption setup containing 25 g of the zeolite bed (flow rate of $100mL\;min^{-1}$). The high est and lowest breakthrough (%) values were shown for PnIs and RSCs, respectively, and the maximum and minimum adsorption capacity (${\mu}g\;g^{-1}$) of the zeolite was observed for the RSCs (range of 0.77-3.4) and PnIs (0.06-0.104), respectively. As a result of sorptive removal by zeolite, a reduction in odor strength, measured as odor intensity (OI), was recorded from the minimum of approximately 0.7 OI units (indole [from 2.4 to 1.6]), skatole [2.2 to 1.4], and p-cresol [5.1 to 4.4]) to the maximum of approximately 4 OI units (methanethiol [11.4 to 7.5], n-valeric acid [10.4 to 6.5], i-butyric acid [7.9 to 4.4], and propionic acid [7.2 to 3.7]). Likewise, when removal was examined in terms of odor activity value (OAV), the extent of reduction was significant (i.e., 1000-fold) in the increasing order of amy acetate, i-butyric acid, phenol, propionic acid, and ammonia.

Sorption of Heavy Metals from the Wastewater by the Artificial Zeolite (인공 제올라이트에 의한 폐수중 중금속 흡착)

  • Lee, Deog-Bae;Lee, Kyeong-Bo;Lee, Sang-Bok;Han, Sang-Soo;Henmi, Teruo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.1
    • /
    • pp.61-66
    • /
    • 1998
  • An artificial zeolite was synthesized from bituminous coal fly ash by thermo-alkali treatment, $100{\pm}3^{\circ}C$ and 3.5 N NaOH solution for 24 hours, to develope new useful material in waste water treatment system. The artificial zeolite had much higher cation exchange capacity, $299cmol^+\;kg^{-1}$ and lower concentration of extractable heavy metals than bituminous coal fly ash. The higher the temperature and the longer the shaking time, the more Zn, Cu, Cd and Pb were sorbed chemically by the artificial zeolite. Shaking artificial zeolite and wastewater at $35^{\circ}C$ for 9 hours, the amount of sorbed heavy metals were $123.5g\;kg^{-1}$ for Zn, $164.7g\;kg^{-1}$ for Cu, $184.4g\;kg^{-1}$ for Cd and $350.6g\;kg^{-1}$ for Pb, respectively.

  • PDF

Development of Oxygen Generator for Vehicle with Two Head Vaccum Pump (Two Head Vacuum Pump를 이용한 차랑용 산소 발생기 개발)

  • Joo, Nam-Kyu;Baek, Gyu-Youl;Cha, Jin-Souk;Lee, Jun-Bae;Kim, Nam-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.114-119
    • /
    • 2004
  • An oxyge generator, which is applied to a particular space such as automobile, must consider compactness and lightweight as well as problems caused by noise, vibration and heat dissipation. For these matters, a BLDC motor was adopted to reduce heat while a bed using synthetic zeolite NaX made it possible to generate high-density oxygen with relatively small size. Moreover, owing to the characteristic of synthetic zeolite Nax, a two-head vacuum pump was designed to desorb nitrogen without additional pump unit.

Biological Treatment of Nutrients and Heavy Metals in Synthetic Wastewater Using a Carrier Attached to Rhodobacter blasticus

  • Kim, Deok-Won;Park, Ji-Su;Oh, Eun-Ji;Yoo, Jin;Kim, Deok-Hyeon;Chung, Keun-Yook
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.666-674
    • /
    • 2022
  • The removal efficiencies of nutrients (N and P) and heavy metals (Cu and Ni) by Rhodobacter blasticus and R. blasticus attached to polysulfone carriers, alginate carriers, PVA carriers, and PVA + zeolite carriers in synthetic wastewater were compared. In the comparison of the nutrient removal efficiency based on varying concentrations (100, 200, 500, and 1000 mg/L), R. blasticus + polysulfone carrier treatment showed removal efficiencies of 98.9~99.84% for N and 96.92~99.21% for P. The R. blasticus + alginate carrier treatment showed removal efficiencies of 88.04~97.1% for N and 90.33~97.13% for P. The R. blasticus + PVA carrier treatment showed removal efficiencies of 18.53~44.25% for N and 14.93~43.63% for P. The R. blasticus + PVA + zeolite carrier treatment showed removal efficiencies of 26.65~64.33% for N and 23.44~64.05% for P. In addition, at the minimum inhibitory concentration of heavy metals, R. blasticus (dead cells) + polysulfone carrier treatment showed removal efficiencies of 7.77% for Cu and 12.19% for Ni. Rhodobacter blasticus (dead cells) + alginate carrier treatment showed removal efficiencies of 25.83% for Cu and 31.12% for Ni.