  • Hemodialysis vascular access dysfunction (HVAD) due to the aggressive development of venous neointimal hyperplasia remains a major complication for patients with synthetic arteriovenous grafts. Paclitaxel-coated expanded polytetrafluoroethylene (ePTFE) grafts effectively prevent neointimal hyperplasia and stenosis. However, perigraft inflammation or edema can be another complication of ePTFE grafts, preventing early cannulation. Three different types of ePTFE grafts, including grafts without paclitaxel coating (control group, n = 12), grafts with paclitaxel coating at a dose density of $0.61ug/mm^2$ (low concentration group, n = 12), and grafts with paclitaxel coating at a dose density of $1.15ug/mm^2$ (high concentration group, n = 12) were placed in the backs of 12 rabbits, simultaneously. Six rabbits were euthanized after one week and the remaining six were euthanized two weeks after implantation. Perigraft inflammation, graft wall inflammation, stromal cell proliferation, blood vessel formation, tissue necrosis and edema were analyzed for the grafts in each animal. Inflammation surrounding the paclitaxel-coated grafts was significantly reduced compared to the control group. Stromal cell layers were detected at the interface between the graft and the surrounding tissue in the control group, infiltrated into the graft interstices, and differentiated into myofibroblasts for graft healing. Paclitaxel-coated grafts inhibited stromal cell proliferation and infiltration into the graft wall. Tissue necrosis and edema were not detected in either of the paclitaxel-coated graft groups.

Blood Compatibility of Artificial Blood-Contacting Surface Seeded with Cultured Bovine Endothelial Cells (소폐동맥 내피세포를 이용한 인조혈액접촉표면의 혈액 접합성)

  • 김원곤;곽영태;유세영
    • Journal of Chest Surgery
    • /
    • v.26 no.2
    • /
    • pp.80-85
    • /
    • 1993
  • Synthetic and biosynthetic vascular grafts of small diameter have long been considered to be prone to thrombosis, ultimately leading to the complete graft occlusion. Endothelial cell seeding onto synthetic blood-contacting surfaces has been suggested to be an ideal means to solve this problem. This study described a culture method of bovine endothelial cells and evaluated blood-compatibility and seeding efficiency of cultured endothelial cells. Bovine pulmonary artery endothelial cells were harvested enzymatically and grown to confluence on polystyrene culture flask surfaces using established techniques. The identification of endothelial cells was made through the demonstration of expression of factor VIII R:Ag by immunofluorescent technique. To quantitate the effect of improvement in blood-compatibility of viable endothelial cells, endothelial monolayers were exposed to blood containing $\^$111/In-oxine labeled platelets. Viable endothelial monolayers retained less labeled platelets than control surfaces. The Indium-labeled endothelial cells were seeded onto three different blood-contacting surfaces of Dacron vascular graft immobilized in specially equipped wells and incubated for specific time intervals (t=15, 30, 60, 120 minutes). Longer incubation times showed improved cell adherence in collagen-coated and fibrin-coated Dacron vascular graft groups. However in untreated Dacron grafts, no direct relationship was observed between incubation time and endothelial cell seeding efficiency. This may be due to leakage of endothelial cells through porosity of Dacron grafts in this in-vitro experimental condition.

  • PDF

Comparison of the Neointima Inhibition Between Paclitaxel- and Sirolimus-Eluting Expanded Polytetrafluoroethylene Hemodialysis Grafts in a Porcine Model

  • Baek, Insu;Cho, AJin;Hwang, Jinsun;Kim, Heasun;Park, Jong-Sang;Kim, Dae Joong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1663-1667
    • /
    • 2013
  • Neointimal hyperplasia causes vascular access dysfunction in hemodialysis patients with synthetic arteriovenous (AV) grafts. Several studies have reported that paclitaxel- or sirolimus-eluting AV grafts inhibit neointimal hyperplasia and display lower rates of stenosis compared with control grafts. However, there have been few comparative studies of the efficacy of paclitaxel- and sirolimus-eluting grafts. We compared the neointimal hyperplasia of paclitaxel- and sirolimus-eluting grafts. AV grafts were implanted laterally between the common carotid artery and the external jugular vein in 12 female Landrace pigs. The animals were sacrificed six weeks after surgery. The neointimal hyperplasia at the anastomosis sites of the grafts was quantified using the ratio of the intragraft hyperplasia to the graft area (H/G ratio) at the graft-vessel interface. The area of intimal hyperplasia at the venous (paclitaxel 1.06 [0.72-1.56] vs sirolimus 2.40 [1.72-3.0] $mm^2$, P = 0.04) and arterial anastomosis sites (paclitaxel 0.93 [0.57-1.48] vs sirolimus 2.40 [1.72-3.0] $mm^2$, P = 0.04) was significantly different between the two groups. However, the H/G ratios for the venous anastomosis site (paclitaxel 0.25 (0.17-0.38) vs sirolimus 0.38 (0.2-0.66), P = 0.4) and the arterial anastomosis site (paclitaxel 0.19 (0.08-0.39) vs sirolimus 0.41 (0.34-0.50), P = 0.1) did not differ significantly between the groups. In conclusion, there was no significant difference in the inhibition of neointimal hyperplasia by sirolimus- and paclitaxel-eluting AV grafts.

Flow Dynamics Near End-To-End Anastomoses - Part I. In Vitro Compliance Measurement -

  • Kim, Y.H
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.165-174
    • /
    • 1992
  • Compliance mismatch across an end-to-end anastomosis was measured In the In vitro experimental setup. A 35mm camera was used and Image process was done in Gould/ DeAnza Image processor. The results showed that compliances of Penrose tubing and synthetic PTFE grafts were In good agreement with the previously reported In vivo data. PTFE grafts exhibited a nonlinear behavior with compliance decreasing with Increasing transmural pressure, whereas the compliance of the Penrose tubing remained relatively constant within the range of the pressures in which data were obtained. The lumen cross sections at the anastomosis were affected by the suture and the mismatch In compliance between the Penrose tubing and vascular grafts. The varla~lons In the lumen dtameter at the anastomosis was more pronounced with increasing transmural pressures. From the present study, it was clearly demonstrated that the compliance of prosthetic grafts Is much lower than that of the arteries. In addition to the hemodynamlc consequences, compliance mismatch across the anastomosis has been known to lead to Increased anastomotlc and suture stresses with resultant suture line dehlscence and false aneurysm formation. Thus, there are good hemodynamic reasons to suppose that Introduction of a less compliant arterial graft Into the arterial circulation wlll be damaging and that grafts should be made to match the elastic behavior of their host arteries as closely possible.

  • PDF

Affinity of Endothelial Cells to a Polyurethane Vascular Graft: A Preliminary Animal Study (폴리우레탄 인공혈관에 대한 혈관내피세포의 친화성: 예비동물실험)

  • Ahn, Seung Hyun;Jun, Young min;Chang, Hak;Park, Chung Hee;Minn, Kyung Won
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.380-384
    • /
    • 2009
  • Purpose: Autologous vessels remain the gold standard for vascular grafts in microanastomoses. However, they are sometimes unavailable and have a limited long - term patency. Synthetic vessels have high success rates in large - diameter reconstructions but failed when used as small - diameter grafts due to graft occlusion. It has been proved that endothelial cell seeding improves prosthesis performance and long - term patency. Among polyurethane, PET and ePTFE, polyurethane has the best affinity to endothelial cells and mechanical properties closest to human vessels. We examined the ability of endothelial cells to attach to a polyurethane graft manufactured by the electrospinning method. Methods: Endothelial cells, which were cultured from porcine internal jugular veins, were attached to polyurethane grafts with an internal diameter of 3 mm. The same cells were attached to allogeneic decellularized porcine internal carotid artery grafts as controls. Both of the 10 mm - long grafts were exposed to endothelial cells in a well for 1 hour. Each well contained $2{\times}10^5$ endothelial cells. The graft materials were rotated through 90 degrees every 15 minutes in order to minimize the effect of gravity. The extent of cell attachment was examined with the MTT assay. Results: The MTT assay showed good incorporation of endothelial cells into both grafts. For the evaluation of affinity, the number of attached cells was counted at 10 fields of microscopic examination with ${\times}40$ magnification. Endothelial cells adhered more to polyurethane grafts (mean, $127.4{\pm}6.2cells$) compared to porcine artery grafts (mean $45.8{\pm}5.1cells$)(p<0.05,Mann - Whitney test). Conclusion: In this study, we attached porcine endothelial cells to polyurethane grafts, manufactured by electrospinning. The grafts exhibited a better affinity to endothelial cells than allogeneic decellularized porcine internal carotid artery grafts. It is suggested that the time required for endothelial cells to attach to decellulized artery grafts may be longer than that which is required for attachment to polyurethane grafts.

Feasibility of a polydioxanone plate as an adjuvant material in rhinoplasty in Asians

  • Oh, Gwang Jin;Choi, Jaeik;Kim, Taek-Kyun;Jeong, Jae-Yong;Kim, Joo-Hak;Kim, Sunje;Oh, Sang-Ha
    • Archives of Plastic Surgery
    • /
    • v.46 no.2
    • /
    • pp.152-159
    • /
    • 2019
  • Background Nasal framework-supporting procedures such as septal extension grafts, derotation grafts, and columellar strut grafts are usually required in rhinoplasty in Asian patients because the skin envelope is tight, but the nasal framework is small and weak. Autologous materials are preferred, but they have some limitations related to the amount that can be harvested and the frequency of use. Therefore, synthetic materials have been used to overcome these limitations. Methods A total of 114 patients who received a polydioxanone (PDS) plate as an adjuvant material in rhinoplasty from September 2016 to August 2017 were retrospectively investigated. The PDS plate was used as to support the weak framework and to correct the contour of the alar cartilages. The PDS plate was used for reinforcement of columellar struts and septal L-struts, alar cartilage push-down grafts, fixation of septal extension grafts, and correction of alar contour deformities Results Primary and secondary rhinoplasty was performed in 103 and 11 patients, respectively. Clinically, no significant inflammation occurred, but decreased projection of the tip was observed in seven patients and relapse of a short nose was noted in five patients. Conclusions PDS plates have been used in the United States and Europe for more than 10 years to provide a scaffold for the nasal framework. These plates can provide reinforcement to columellar struts, L-struts, and septal extension grafts. In addition, they can assist in deformity correction. Therefore, PDS plates can be considered a good adjuvant material for Asian patients with weak and small nasal cartilage.

Comparative study of new bone formation capability of zirconia bone graft material in rabbit calvarial

  • Kim, Ik-Jung;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.167-176
    • /
    • 2018
  • PURPOSE. The purpose of this study was to compare the new bone formation capability of zirconia with those of other synthetic bone grafts. MATERIALS AND METHODS. Twelve rabbits were used and four 6-mm diameter transcortical defects were formed on each calvaria. Each defect was filled with Osteon II (Os), Tigran PTG (Ti), and zirconia (Zi) bone grafts. For the control group, the defects were left unfilled. The rabbits were sacrificed at 2, 4, and 8 weeks. Specimens were analyzed through micro computed tomography (CT) and histomorphometric analysis. RESULTS. The Ti and Zi groups showed significant differences in the amount of newly formed bone between 2 and 4 weeks and between 2 and 8 weeks (P<.05). The measurements of total bone using micro CT showed significant differences between the Os and Ti groups and between the Os and Zi groups at 2 and 8 weeks (P<.05). Comparing by week in each group, the Ti group showed a significant difference between 4 and 8 weeks. Histomorphometric analysis also showed significant differences in new bone formation between the control group and the experimental groups at 2, 4, and 8 weeks (P<.05). In the comparison of newly formed bone, significant differences were observed between 2 and 4 weeks and between 2 and 8 weeks (P<.05) in all groups. CONCLUSION. Zirconia bone graft material showed satisfactory results in new bone formation and zirconia could be used as a new synthetic bone graft material.

Development of Bioartificial Skin for Skin Regeneration (손상된 피부 재건을 위한 바이오인공피부의 개발 동향)

  • Seo, Young-Kwon;Song, Kye-Yong;Park, Jung-Keug
    • KSBB Journal
    • /
    • v.23 no.1
    • /
    • pp.8-17
    • /
    • 2008
  • There are many different approaches to healing of acute and chronic ulcer and large skin defect, such as burn. Currently available wound covers fall into two categories. Permanent covering, such as autografts, and temporary ones, such as allograft including de-epidermized cadaver skin, bioartificial skin, xenografts, and synthetic dressings. Autologous skin grafting in the form of split- or full-thickness skin is still the good standard. Following on from developments in the 1980s involving the use of cultured keratinocyte grafts in wound healing, the last decade has been great progress in the fabrication of composite bioartificial skin grafts. However, two bottleneck on producing cultured bioartificial skin, whether of the simple epithelial cell sheet type, or the more complex composite type, continue to be the generation of sufficient keratinocytes cheaply and quickly and develop biocompatible dermal scaffolds. This article covers the development, clinical application, and current research directions associated with bioartificial skin.

Animal Experiments on an Antithrombogenic Small-Caliber Vascular Prostheses and Vascualr Patch : Observation in Canine Models (항혈전성 소구경 인조 혈관 및 봉합편에 대한 동물 실험)

  • 김수철;김원곤;유세영
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.63-72
    • /
    • 2003
  • Although a variety of synthetic vascular grafts are available in modern vascular surgery, no ideal prosthesis ha,4 yet been developed. Small-caliber vascular grafts with low flow, as used in the lower extremity, continue to become thrombosed at unacceptable rates. We have developed and evaluated the new antithrombogenic blood contacting surfaces in canine model. Material and Method: Two now antithrombogenic blood contacting surfaces(Polyvinylalcohol -Polyurethane(PVA-PU) blend and natural Graphite-polyurethane(G-PU) blend) have been developed and evaluated in canine model, using vascular grafts and patches. The luminal surfaces of the test vascular grafts(5 mm ID) were fabricated by dipping a glass rod in PVA-PU blend solution(50 % PVA) using phase separation method. Mongrel dogs of either sex weighing 18-22 kg were anesthetized by endotracheal intubation using halothane and their lungs were ventilated with a volume-cycled ventilator, Maintenance anesthesia with 0.5-1.0% halothane and supplemental oxygen was used. Two pairs were used for comparison in the bilateral femoral arteries for both vascular grafts(PVA-PU vs. PU) and vascular patches(G-PU vs. PU). Bilateral groin incisions were made and the arteries were exposed and clamped. After an excision of 1 cm of the artery between clamps, a grail of 2.5 cm in length was implanted end-to-end using 6-0 polypropylene suture. The vascular patch was implanted as a form of on-lay patch. Animals were sacrificed at 1, 2, 4, 6, 8 and 16 weeks for vascular grafts and 1, 2. 4 and 6 weeks for vascular patches. Result The vascular grafts of PVA-PU blends showed patent lumina in the 2 and 16 weeks animals, while those of PU showed a patent lumen in 2 weeks animal. PVA-PU graft of 16 weeks showed a fairly clean luminal surface. A light microscopic finding of this graft demonstrated good tissue infiltration through porosity, The animals with vascular patches showed patent arteries in both groups except 2 weeks animal. Scanning electron microscopy of the luminal surfaces of G-PU patches in 4 and 6 weeks animals showed endothelial cell covering with microvilli. PU patches showed qualitatively less endothelial cell covering. Conclusion: In conclusion, PVA-PU and G-PU blends can be a promising blood contacting surfaces for application in a synthetic vascualr graft. However, further animal study is needed to determine the real long-term effects of these methods of surface modifications.

Use of Synthetic Bone Material with Osteoinductive Proteins to Promote Bone Healing in Dogs (개에서 골형성 촉진을 위한 합성 골물질과 골유도 단백질의 사용)

  • Choi, Sung-Jin;Jung, In-Seong;Yoo, Yong-Kyu;Seo, Beom-Seok;Choi, Gab-Chol;Kim, Nam-Soo
    • Journal of Veterinary Clinics
    • /
    • v.31 no.5
    • /
    • pp.417-420
    • /
    • 2014
  • Bone grafts are essential for promoting bone healing in some orthopedic cases, and synthetic bone materials have been widely used for bone defects. In addition, osteoinductive proteins such as bone morphogenetic protein and fibroblast growth factor promote osteoblast differentiation and proliferation. The combination of these factors is very useful clinically for promoting bone healing. In this study, we report the use of synthetic bone materials and osteoinductive proteins to repair bone defects in two dogs.