위상전이 풀-브리지 DC/DC 컨버터를 이용한 차세대 고속 전철용 Battery Charger에 관한 연구 (A Study on Battery Chargers for the next generation high speed train using the Phase-shift Full-bridge DC/DC Converter)

  • 조한진;이원철;이상석;김태환;원충연
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.623-628
    • /
    • 2009
  • There is an increasing demand for efficient high power/weight auxiliary power supplies for use on high speed traction application. Many new conversion techniques have been proposed to reduce the voltage and current stress of switching components, and the switching losses in the traditional pulse width modulation(PWM) converter. Especially, the phase shift full bridge zero voltage switching PWM techniques are thought most desirable for many applications because this topology permits all switching devices to operate under zero voltage switching(ZVS) by using circuit parasitic components such as leakage inductance of high frequency transformer and power device junction capacitance. The proposed topology is found to have higher efficiency than conventional soft-switching converter. Also it is easily applicable to phase shift full bridge converter by applying an energy recovery snubber consisted of fast recovery diodes and capacitors.

  • PDF

차세대 고속 전철용 Battery Charger 에 관한 연구 (A Study on the Battery Charger for Next Generation High Speed Train)

  • 정한정;이원철;이상석;백진성;원충연
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.321-324
    • /
    • 2008
  • Recently, there is an increasing demand for efficient high power/weight auxiliary power supplies for use on high speed traction application. many new conversion techniques have been proposed to reduce the voltage and current stress of switching components, and the switching losses in the traditional pulse width modulation(PWM) converter. Among them, the phase shift full bridge zero voltage switching PWM techniques are thought most desirable for many applications because this topology permits all switching devices to operate under zero voltage switching(ZVS) by using circuit parasitic components such as leakage inductance of high frequency transformer and power device junction capacitance. The proposed topology is found to have higher efficiency than conventional soft-switching converter. Also it is easily applicable to phase shift full bridge converter by applying an energy recovery snubber consisted of fast recovery diodes and capacitors.

  • PDF

터빈 속도신호의 자동백업 시스템 개발 (Development of automatic backup systems for turbine speed signal)

  • 김관행;김호찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.844-846
    • /
    • 1999
  • A speed signal of governor, which control the output and speed of a generator, is important because a signal failure can be causing the shutdown of a power plant. thus, it is necessary to introduce switching method with two complementary signal. This paper presents a comparative study of speed signal switching methods. One of the Proposed methods has been tested at a power plant in Pukcheju and the approach described here is expected to be of wide applicability.

  • PDF

고장 유형별 고속 인터럽터의 동작 특성 (The Operational Characteristics of High-speed Interrupter by Fault Types)

  • 정인성;최효상;정병익
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.278-283
    • /
    • 2013
  • With the increasing power demands, size of the fault current in electrical grids is steadily increasing, and it exceeds the breaking capacity of circuit breakers. To effectively cope with these problems, a high-speed interrupter was suggested. The high-speed interrupter provides fault current with a bypass to a fault current limiter in case of accidents and consequently, fault current can be restricted. In this study, behavioral characteristics of high-speed interrupter were analyzed by accident types occurred in a distribution system. When accidents occurred, a and b contact of the high-speed interrupter were turned-off and then, turned-on. Accordingly, fault current flowed to the circuit connected to a current limiting element, and the fault current limiter restricted fault current to within a half-cycle. Nevertheless, the behavior of the high-speed interrupter was slowed down by a switching surge. As a result, fault current was confirmed to be restricted not to within the anticipated half-cycle, but to after a half-cycle. Moreover, the behavioral characteristics of the high-speed interrupter changed not only by accident types, but by behaviors of R, S, and T phases. This was due to the errors in stroke lengths of the high-speed interrupters, which resulted in a slight time discrepancy among three interrupters. In addition, the switching behaviors of the b and a contact were confirmed not to have coincided due to the switching surge; b contact behaved first and a contact followed. because of this, accuracy of stroke length and switching surges through the solenoid suction increases may be necessary to resolve.

전도성 운전기판을 이용한 다층기판에서의 Simultaneous Switching Noise 감소 기법 (Simultaneous Switching Noise Reduction Technique in Multi-Layer Boards using Conductive Dielectric Substrate)

  • 김성진;전철규;이해영
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 1999년도 추계 기술심포지움 논문집
    • /
    • pp.33-36
    • /
    • 1999
  • In this paper, we proposed a simultaneous switching noise(SSN) reduction technique in muti-layer beards(MLB) for high-speed digital applications and analyzed them using the Finite Difference Time Domain(FDTD) method. The new method by conductive dielectric substrates reduces SSN couplings and resonances, significantly, which cause series malfunctions in the modem high-speed digital applications.

  • PDF

광대역 교환을 위한 InP JFET소자 (InP JFET Devices for High Speed Switching Application)

  • 지윤규;김성준;정종민
    • 전자공학회논문지A
    • /
    • 제28A권5호
    • /
    • pp.370-374
    • /
    • 1991
  • A high performance fully ion-implanted InP JFET was characterized for high speed switching elements. The switch has an insertion loss of 5.5dB with 31.6dB isolation at 1GHz. This device can effectively swithc a byte-multiplexed 2Gb/s signal and an eye-diagram taken at 2Gb/s shows an error-free eye pattern. Therefore, this device can be used as a switching element for high transmission data rate for monolithic integration of optoelectronic circuit in the long-wavelength region.

  • PDF

부하 변동에 대한 유도 전동기의 속도 제어 특성에 관한 연구 (A Study on the Improvement of the IM Speed Control Characteristics with Load Torque Variation)

  • 강문호;김남정;유기윤;박귀태;민경일
    • 대한전기학회논문지
    • /
    • 제43권7호
    • /
    • pp.1075-1083
    • /
    • 1994
  • In this paper, a study on the improvement of the IM speed response against load torque variation is presented. A VSCS(Variable Structure Control System) is proposed which gives the desired robustness against load torque variation using a new kind of time-varing switching plane. In order to eliminate the reaching phase of the states from one switching plane to another during variation, the switching plane is varied continuously. To verify the high dynamic performance of the proposed VSCS, simulation and experimental results are presented.

A Ringing Surge Clamper Type Active Auxiliary Edge-Resonant DC Link Snubber-Assisted Three-Phase Soft-Switching Inverter using IGBT-IPM for AC Servo Driver

  • Yoshitsugu, Junji;Yoshida, Masanobu;Hiraki, Eiji;Inoue, Kenji;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제2B권3호
    • /
    • pp.115-124
    • /
    • 2002
  • This paper presents an active auxiliary edge-resonant DC link snubber with a ringing surge damper and a three-phase voltage source type zero voltage soft-switching inverter with the resonat snubber treated here for the AC servo motor driver applications. The operation of the active auxiliary edge-resonant DC link snubber circuit with PWM voltage is described, together with the practical design method to select its circuit parameters. The three-phase voltage source type soft-switching inverter with a single edge-resonant DC link snubber treated here is evaluated and discussed for the small-scale permanent magnet (PM) type-AC servo motor driver from an experimental point of view. In addition to these, the AC motor stator current and its motor speed response for the proposed three-phase soft-switching inverter employing Intelligent Power Module(IPM) based on IGBTS are compared with those of the conventional three-phase hard-switching inverter using IPM. The practical effectiveness of the three-phase soft-switching inverter-fed permanent magnet type AC motor speed tracking servo driver is proven on the basis of the common mode current in a novel type three-phase soft-switching inverter-fed AC motor side and the conductive noise on the mains terminal interface voltage as compared with those of the conventional three-phase hard-switching inverter-fed permanent magnet type AC servo motor driver for the speed tracking applications.

높은 격리도와 고속 스위칭의 PIN 다이오드 스위치 (A PIN Diode Switch with High Isolation and High Switching Speed)

  • 주인권;염인복;박종흥
    • 한국전자파학회논문지
    • /
    • 제16권2호
    • /
    • pp.167-173
    • /
    • 2005
  • 직렬 PIN 다이오드 스위치의 격리도는 PIN 다이오드의 병렬 커패시턴스에 의해 제한을 받으며, 스위치 구동회로는 PIN 다이오드 스위치의 스위칭 속도를 제한한다. 이런 문제를 극복하기 위해, 병렬 공진 인턱턴스와 TTL 호환의 스위치 구동회로가 적용된 높은 격리도와 고속 스위칭의 PIN 다이오드 스위치를 제안하였다. 3 GHz PIN 다이오드 스위치의 측정 결과, 1 GHz의 주파수 대역폭, 1.5 dB 이내의 삽입 손실, 65 dB의 격리도, 15 dB 이상의 반사 손실 그리고 30 ns 이내의 스위칭 속도를 나타내었다. 특히, 병렬 공진 인덕턴스를 사용한 3 GHz스위치는 15 dB의 격리도 향상을 나타내었다.

스위치드 릴럭턴스 전동기 구동을 위한 히스테리시스 전류 제어형 공진형 C-Dump 컨버터 (A Hysteresis Current Controlled Resonant C-Dump Converter for Switched Reluctance Motor)

  • 윤용호;김재문
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.72-78
    • /
    • 2008
  • The speed variation of SRM is fulfilled throughout a transition from chopping control to single pulse operation. (i,e., low speed to high speed operation). It is unsatisfied with performance at all operational regimes. In this paper, the operational performance of SRM can be improved by using current hysteresis control method. This method maintains a generally flat current waveform. At the high speed, the current chopping capability is lost due to the development of the back-EMF. Therefore SRM operates in single pulse mode. By using zero-current switching and zero-voltage switching technique, the stress of power switches can be reduce in chopping mode. When the commutation from one phase winding to another phase winding, the current can be zero as fast as possible in this period because several times negative voltage of DC-source voltage produce in phase winding. This paper is compared to performance based on conventional C-dump converter topology and the proposed resonant C-dump converter topology. Simulation and experimental results are presented to verify the effectiveness of the proposed circuit.