• 제목/요약/키워드: switching control

검색결과 3,047건 처리시간 0.03초

슬라이딩 모드 제어와 스위칭 기법에 기반한 수상함의 경로 추종 제어기 설계 (Path Tracking Controller Design for Surface Vessel Based on Sliding Mode Control Method with Switching Law)

  • 이준구
    • 한국군사과학기술학회지
    • /
    • 제20권1호
    • /
    • pp.108-118
    • /
    • 2017
  • In this paper, the path tracking controller for a surface vessel based on the sliding mode control (SMC) with the switching law is proposed. In order to have no restriction on movement and improved tracking performance, the proposed control system is developed as follows: First, the kinematic and dynamic models in Cartesian coordinates are considered to solve the singularity problem at the origin. Second, the new multiple sliding surfaces are designed with the SMC and approach angle concept to solve the under-actuated property. Third, the switching control system is designed to improve tracking performance. To prove the stability of the proposed switching system under the arbitrary switching, the Lyapunov stability analysis method with the common Lyapunov function is used. Finally, the computer simulations are performed to demonstrate the performance, effectiveness and stability of the proposed tracking controller of a surface vessel.

소프트 스위칭형 PFC 승강압 AC-DC 컨버터에 관한 연구 (A Study on PFC Buck-Boost AC-DC Converter by Soft Switching Method)

  • 곽동걸;이승호;이봉섭;정도영;심재선;임진근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.435-437
    • /
    • 2007
  • Authors propose a PFC(power factor correction) Buck-Boost AC-DC converter by soft switching method. The proposed converter for a discontinuous conduction mode eliminates the complicated control requirement and reduces the size of components. The input current waveform in the converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of ac input voltage under the constant duty cycle switching.Therefore,the input power factor is nearly unity and the control algorithm is simple. To achieve high efficiency system, the proposed converter is constructed by using a partial resonant technique. The control switches using in the converter are operated with soft switching for a partial resonant. The control switches are operated without increasing their voltage and current stresses by the soft switching method. The result is that the switching loss is very low and the efficiency of converter is high.

  • PDF

유압브레이커의 수동 무단 타격력 제어기구 개발에 대한 연구 (A Study on Manually and Continuously Variable Impact Force Control Device Development for Hydraulic Breakers)

  • 강영기;장주섭
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권4호
    • /
    • pp.46-53
    • /
    • 2020
  • In this paper, the development of a manually and continuously variable impact force control mechanism for hydraulic breakers was studied. Generally, a hydraulic breaker has one or two piston strokes. Hydraulic breakers, which have two strokes, have two valve-switching ports and make short and long piston strokes. The piston stroke valve controls the piston stroke by opening and closing a short stroke-switching port. The short piston stroke mode is used to break soft rock, concrete, or asphalt. This stroke control valve system is not popular for small hydraulic breakers mounted on 1 to 14-ton excavators. To preserve the carrier-like excavator, proper breaking force is needed, and it can be easily controlled by multiple piston stroke control valves. The easiest way to control these breakers is to use several switching ports and valves but they are not easy to install in small hydraulic breakers and are expensive. To use only one switching port and valve, a method can be used to change the open area of the switching port to delay valve switching. This method provides multiple piston strokes.

일정 스위칭 주파수를 위한 유도전동기의 직접토오크 제어 (Direct Torque Control Of Induction Motor for Constant Switching Frequency)

  • 최연옥;정병호;임병옥;정삼용;서진연;조금배;백형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1152-1154
    • /
    • 2002
  • In this paper, a direct torque control method of an induction motor is proposed which enables constant switching frequency. The switching strategy of a conventional direct torque control scheme which is based on hysteresis comparator results in a variable switching frequency which depends on the speed, flux, stator voltage and hysteresis band of the comparator. This paper proposes a new switching strategy which determine the effective switching time on each switching period by comparing the ascending and descending torque slopes. The simulation results are presented to verify this proposed scheme.

  • PDF

Computational solution for the problem of a stochastic optimal switching control

  • Choi, Won-Sik
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국제학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.155-159
    • /
    • 1993
  • In this paper, we consider the problem of a stochastic optimal switching control, which can be applied to the control of a system with uncertain demand such as a control problem of a power plant. The dynamic programming method is applied for the formulation of the optimal control problem. We solve the system of Quasi-Variational Inequalities(QVI) using an algoritlim which involves the finite difference approximation and contraction mapping method. A mathematical example of the optimal switching control is constructed. The actual performance of the algorithm is also tested through the solution of the constructed example.

  • PDF

새로운 스위칭 변수를 이용한 가변구조제어에 관한 연구 (A Study on the Variable -Structure Control Using New Switching Variables)

  • 이주장;이흥규;이병일
    • 대한전자공학회논문지
    • /
    • 제25권12호
    • /
    • pp.1586-1593
    • /
    • 1988
  • A new control scheme for the variable-structure control system using new time-varying switching variable is presented in this paper. It is proposed to have new algorithm for reducing the reaching time on a switching hyperplane by modifying the Morgan's algorithm. From the results of the simulation, it is concluded the proposed control algorithm yields smaller control inputs (without disturbance) and ripples (with disturbance) than that obtained by Morgan's algorithm in the steady-state. This control algorithm can be applied to proper control systems having sensitive effects on disturbances, due to the robustness.

  • PDF

반브리지형 스위칭 전원의 설계 및 제어 (Design and Control of the Half-Bridge Type Switching Regulator)

  • 고영길;이광원
    • 대한전기학회논문지
    • /
    • 제33권2호
    • /
    • pp.76-82
    • /
    • 1984
  • This paper presents the design and the optimal control method of current-fed half-brige switching regulator. To achieve fast response load current variation is fed to control input, and simple optimal control model has been derived with provision of current control loop in the control circuit. Test results show that the control system model is correct and 5ms response time has been obtained at 25 KHz switching frequency.

  • PDF

직류 전동기의 저손실 구동을 위한 일정 주파수 제어형 영전압 스위칭 변환기의 구현 (Implement of Constant-Frequency-Controled Zero-Voltage-Switching Converter-fed DC Motor Drive for Low Power Loss)

  • 고문주;박진홍;한완옥;이성백
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2148-2150
    • /
    • 1998
  • This paper proposes a constant frequency controlled zero voltage switching method that can reduce switching losses caused by emf on inductance in DC motor. The zero voltage switching method is used more than a zero current switching method because of reducing switching losses by capacitance of depletion region of MOSFET. To simplify the controller circuit, we propose constant frequency controlled zero voltage switching method in the paper. The control method is more stable than a variable frequency control method because it can optimize bandwidth of a closed-loop and reactances. Therefore, we construct a constant frequency controlled zero voltage switching converter and improve zero switching losses in high switching frequency. In the process, we can control low-losses in full range on variable voltage and load. We simulate the proposed converter with P-SPICE and compare results obtained through the experiment.

  • PDF

3상 승압형 AC/DC 컨버터의 고역율과 스위칭 손실 저감을 위한 공진 PWM 스위칭 기법에 관한 연구 (Study on Resonant PWM Switching Technique for $3{\phi}$ Boost AC/DC Converter with High Power Factor and Less Switching Loss)

  • 이은규;노영남;김병진;전희종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.541-543
    • /
    • 1997
  • In this paper, a proposed resonant PWM switching technique makes the boost AC/DC converter to high input power factor and less switching loss. Also, the switching control scheme is used which minimize harmonic components employing novel PWM technique. In addition, an employment of resonant circuit for switching makes zero current switching(ZCS) and zero voltage switching(ZVS) for control switches without switching losses. The result shows that high power factor is still for varying load and switching loss is very low.

  • PDF

시각동기 스위칭 GPS 중계기를 이용한 실내측위 시스템 (An Indoor Positioning System Using Time-Synchronized Switching GPS Repeater)

  • 임성혁;지규인
    • 제어로봇시스템학회논문지
    • /
    • 제12권8호
    • /
    • pp.789-797
    • /
    • 2006
  • A new method for the GPS repeater based indoor positioning is proposed and its feasibility is verified by experiments in previous paper. But the problems how can identify switching GPS repeater's ID and when switching will be occurred are remained. To solve the problem faced with, we propose the time synchronized switching GPS repeater and the methods of the detection of switching time and the estimation of TDOA. First, switching GPS repeater retransmits the signals synchronized on GPS time, sequentially. Always, first switching time is synchronized with 1 PPS. Second, we formulate the detection of switching time and the estimation of TDOA and propose the various methods. No method is existed absolutely superior to others in any conditions but the method is existed superior to others in specific condition. Finally, feasibility of indoor positioning using time-synchronized switching GPS repeater is evaluated through experiments in anechoic chamber and general environment with multipath.