• Title/Summary/Keyword: sustained shift

Search Result 31, Processing Time 0.029 seconds

GLR Charts for Simultaneously Monitoring a Sustained Shift and a Linear Drift in the Process Mean

  • Choi, Mi Lim;Lee, Jaeheon
    • Communications for Statistical Applications and Methods
    • /
    • v.21 no.1
    • /
    • pp.69-80
    • /
    • 2014
  • This paper considers the problem of monitoring the mean of a normally distributed process variable when the objective is to effectively detect both a sustained shift and a linear drift. The design and application of a generalized likelihood ratio (GLR) chart for simultaneously monitoring a sustained shift and a linear drift are evaluated. The GLR chart has the advantage that when we design this chart, we do not need to specify the size of the parameter change. The performance of the GLR chart is compared with that of other control charts, such as the standard cumulative sum (CUSUM) charts and the cumulative score (CUSCORE) charts. And we compare the proposed GLR chart with the GLR charts designed for monitoring only a sustained shift and for monitoring only a linear drift. Finally, we also compare the proposed GLR chart with the chart combinations. We show that the proposed GLR chart has better overall performance for a wide range of shift sizes and drift rates relative to other control charts, when a special cause produces a sustained shift and/or a linear drift in the process mean.

Development of a Fatigue Index Based on the Measurement of Localized Muscular Fatigue During the Cyclic Isometric Contraction (주기적 등척성 수축에서의 국소근육피로 측정을 통한 피로지수의 개발)

  • Jung, So-Ra;Chung, Min-Keun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.19 no.4
    • /
    • pp.87-96
    • /
    • 1993
  • Spectrum analysis of surface electromyogram (FMG) signals is an effective approach to the study of localized muscular fatigue during isometric contraction. Many investigators have con firmed the frequency of the EMG signals being lowered during sustained contaction. In this study, the cyclic loading tasks were performed, and a comparison was made for the median power frequency shift pattern of the EMG signals with the sustained contraction of the same load. The median power frequency shift of the EMG signals for the cyclic loading task was found to be a part of that for the sustained contraction. Based on this result, a new muscle fatigue index was computed by normalizing the duration of the sustained contraction. A fatigue index was obtained as a function of exertion level and the work/rest schedule. With the proposed fatigue index, it is possible to evaluate or predict the degree of muscular fatigue for a physically demanding task.

  • PDF

A Digital Self-Sustained Phase Shift Modulation Control Strategy for Full-Bridge LLC Resonant Converters

  • Zheng, Kai;Zhou, Dongfang;Li, Jianbing;Li, Li;Zhao, Yujing
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.915-924
    • /
    • 2016
  • A digital self-sustained phase shift modulation (DSSPSM) strategy that allows for good soft switching and dynamic response performance in the presence of step variations is presented in this paper. The working principle, soft switching characteristics, and voltage gain formulae of a LLC converter with DSSPSM have been provided separately. Furthermore, the method for realizing DSSPSM is proposed. Specifically, some key components of the proposed DSSPSM are carefully investigated, including a parameter variation analysis, the start-up process, and the zero-crossing capture of the resonant current. The simulation and experiment results verify the feasibility of the proposed control method. It is observed that the zero voltage switching of the switches and the zero current switching of the rectifier diodes can be easily realized in presence of step load variations.

EMG Power Spectral Analysis on Masticatory Muscle Fatigue in Chronic Muscle Pain Patients (근전도 power spectrum을 이용한 만성근육동통 환자에 있어서의 저작근 피로에 관한 연구)

  • 이채훈;김영구;임형순
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.1
    • /
    • pp.145-155
    • /
    • 1997
  • The purpose of this study was to compare differences in endurance time and EMG power spectral characteristics of the masticatory muscles during sustained isometric contraction between patients and controls. 15 CMD patients{8 women and 7 men, aged 15 to 38 years(24.1$\pm$7.5)}, and 15 healthy volunteers{8 women and 7 men, aged 15 to 30 years(24.7$\pm$3.4)} without past history or present symptoms of CMD were included in this study. Sustained isometric contractions of masticatory muscles were perfomeed as long as possible at 50% level of maximum voluntary contraction(MVC) of EMG activity via visual feedback, and the duration of sustained isometric contraction(endurance time) was examined. The author perfomed EMG power spectral analysis in the myoelectric signals of masseter and anterior temporal muscle during sustained isometric contraction in CMD patients with chronic muscle pain and healthy controls. The author came to following conclusions from the results. 1. The endurance time of the patient group was shorter than the control group in sustained isometric contraction of masticatory muscles(p<0.01). 2. MF values of masticatory muscles with sustained isometric contraction during endurance time were decreased following regression line in both groups(p<0.01, r>0.9). 3. The amount of MF shift to lower frequency range exhibited no significant differences between the patients and the control group in sustained isometric contraction during endurance time. 4. SMF to lower frequency range of the patient group was steeper than the control group in sustained isometric contraction during endurance time(p<0.05).

  • PDF

Design of the GLR Chart in Integrated Process Control (통합공정관리에서 일반화가능도비 관리도의 설계)

  • Chun, Ga-Young;Lee, Jae-Heon
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.3
    • /
    • pp.357-365
    • /
    • 2010
  • This paper considers the integrated process control procedure for detecting special causes in an IMA(1,1) noise process that is being adjusted using a minimum mean squared error adjustment. As a SPC procedure, we use a GLR chart for detecting special causes whose effects are the sustained shift or the sustained drift in the process mean, and the sustained shift in the process variance. For the design of the GLR chart, we derive expressions for the control limit which accurately satisfies the given in-control ARL.

Isolated Spinal Accessory Nerve Palsy from Volleyball Injury

  • Holan, Cole A.;Egeland, Brent M.;Henry, Steven L.
    • Archives of Plastic Surgery
    • /
    • v.49 no.3
    • /
    • pp.440-443
    • /
    • 2022
  • Spinal accessory nerve (SAN) palsy is typically a result of posterior triangle surgery and can present with partial or complete paralysis of the trapezius muscle and severe shoulder dysfunction. We share an atypical case of a patient who presented with SAN palsy following an injury sustained playing competitive volleyball. A 19-year-old right hand dominant competitive volleyball player presented with right shoulder weakness, dyskinesia, and pain. She injured the right shoulder during a volleyball game 2 years prior when diving routinely for a ball. On physical examination she had weakness of shoulder shrug and a pronounced shift of the scapula when abducting or forward flexing her shoulder greater than 90 degrees. Manual stabilization of the scapula eliminated this shift, so we performed scapulopexy to stabilize the inferior angle of the scapula. At 6 months postoperative, she had full active range of motion of the shoulder. SAN palsy can occur following what would seem to be a routine volleyball maneuver. This could be due to a combination of muscle hypertrophy from intensive volleyball training and stretch sustained while diving for a ball. Despite delayed presentation and complete atrophy of the trapezius, a satisfactory outcome was achieved with scapulopexy.

Relationships between Shift Work and Occupational Accidents in a Steel Company (철강회사에 있어서 교대작업과 산업재해의 관련성)

  • Seo, Yoo-Jin;Kazuya, Matsumoto;Moon, Se-Keun;Jung, Min-Sang;Kim, Myung-Il
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.188-196
    • /
    • 2005
  • Accident reports from 1991 to 2000 of a steel company were used to analyze which factors induce industrial accidents. The subjects were 8,311 blue-collar workers, who sustained 114 occupational injuries and work on a continuous full-day 3-team 3-shift system of backward rotation(mornings to afternoons to nights). With respect to marital status, the occupational injury rate(OIR) on the married workers was significantly higher compared to unmarried workers. With respect to no, the OIR of those in their early 20s was significantly higher when compared to other age groups. The OIR of highly educated workers showed a reduction when compared with lower educated workers. The OIR of shift workers were significantly higher compared with the daytime workers. The OIR of type of work decreased across the steel manufacturing process, rolling process, machine maintenance section forwarding products section to the field management section. With respect to the block of shift work(morning, afternoon, and night shifts) by the type of work, the OIR of the night shift was higher than those of the morning shift in the steel manufacturing process or forwarding products section. The OIR of the machine maintenance section was slightly higher in the morning shift than those of the night shift. The OIR of the time of day of the shift workers reached a peak between 09:00 and 11:00. The OIR of a slight injury to shift workers decreased across the night, afternoon, to morning shifts whereas the OIR of a serious injury tended to decrease across the night, morning, to afternoon shift. The body parts most commonly injured were the arm and the crus.

Statistical analysis on long-term change of jitter component on continuous speech signal (음성신호의 Jitter 성분의 장시간 변화에 관한 통계적 분석)

  • Jo, Cheolwoo
    • Phonetics and Speech Sciences
    • /
    • v.12 no.4
    • /
    • pp.73-80
    • /
    • 2020
  • In this study, a method for measuring the jitter component in continuous speech is presented. In the conventional jitter measurement method, pitch variabilities are commonly measured from the sustained vowels. In the case of continuous speech, such as a spoken sentence, distortion occurs with the existing measurement method owing to the influence of prosody information according to the sentence. Therefore, we propose a method to reduce the pitch fluctuations of prosody information in continuous speech. To remove this pitch fluctuation component, a curve representing the fluctuation is obtained via polynomial interpolation for the pitch track in the analysis interval, and the shift is removed according to the curve. Subsequently, the variability of the pitch frequency is obtained by a method of measuring jitter from the trajectory of the pitch from which the shift is removed. To measure the effects of the proposed method, parameter values before and after the operations are compared using samples from the Kay Pentax MEEI database. The statistical analysis of the experimental results showed that jitter components from the continuous speech can be measured effectively by proposed method and the values are comparable to the parameters of sustained vowel from the same speaker.

Controlled Release and Bioavailability of Piracetam (피라세탐의 방출조절 및 생체이용률)

  • Kang, Chin-Yang;Lee, Kyung-Tae;Seo, Seong-Hoon
    • Journal of Pharmaceutical Investigation
    • /
    • v.28 no.2
    • /
    • pp.109-113
    • /
    • 1998
  • This study is purposed to develop the sustained release and bioavailability of piracetam (PA). The use of alginate beads as a means to achieve sustained release of piracetam was evaluated in comparison with that of piracetam alone. In the PA-sodium alginate(SA) beads was confirmed by differential scanning calorimetry thermogram(DSC), indicating a relative shift of an endometric peak of PA to higher temperature. The changes in dissolution rates from PA-SA beads and PASA beads coated by chitosan(CHO) were significantly slower than that of intact PA. The release rate of PA-SA in the gastric fluid was markedly decreased compared with that in the intestinal fluid, suggesting that PA is mostly released in the intestinal fluid. However, the PA/SA ratio scarcely affected the release profile. The blood concentration- time curves of PA, PA-SA and PA-SA-CHO were obtained by oral administration to rats. $T_{max}$ of PA, PA-SA and PA-SA-CHO were 1, 10 and 6 hours, respectively. It was confirmed that the release of PA was prolonged by the formulation of PA-SA beads and PA-SA-CHO beads.

  • PDF

Preparation and Evaluation of Phenylpropanolamine HCI by Complexation with Cation Exchange Resin (양이온교환수지복합체에 의한 페닐프로판올아민염산염의 제조 및 평가)

  • Kim, In-Kyu;Lee, Kyung-Tae;Seo, Seong-Hoon;Kim, Chong-Kook;Kim, Dong-Hyun;Rho, Young-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.29 no.4
    • /
    • pp.309-313
    • /
    • 1999
  • This study was prepared to develop the sustained release dosage form of phenylpropanolamine hydrochloride (PPA) by complexation with cation exchange resin(CER). The PPA-CER complex was confirmed by differential scanning calorimetry(DSC) thennogram, indicating a relative shift of an endometric peak of PPA to higher temperature. The loading efficiency was increased as the amount of PPA was increased as well as the time of fractional exchange was advanced as the temperatures were increased. Loading efficiency, fractional exchange, reaction rate constant and activation energy were highly dependent on the temperature and drug : resin ratio. The optimal ratio of PPA and resin was estimated to be 10: 10 for the sustained release.

  • PDF