• Title/Summary/Keyword: surge

Search Result 1,831, Processing Time 0.023 seconds

Effects of Axial Flow Compressor Surge on the Performance of Turbofan Engine (터보팬 엔진의 축류압축기 서지가 엔진성능에 미치는 영향)

  • Oh, Chang-Yong;Koo, Ja-Ye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.3
    • /
    • pp.1-8
    • /
    • 2009
  • This thesis has analyzed the effect of the surge happening in flight on the engine performance, especially on the PW4000 turbofan engine. It is to be judged that the flight surge can occur more often at the time of takeoff than it does en route due to the fact that the engine parameters are prone to fluctuate. EPR is judged to be the most highly sensitive parameter responding when surge occurs. Both Engine rpm and Wf decrease almost simultaneously just like an EPR. During the take-off rolling, N1 vibration is more sensitive than the N2 vibration. Consequently, the surge can be detected by EGT increase, while the other parameters (EPR, rpm, Wf, etc) decrease.

Coordination between Voltage-Limiting Surge Protective Devices in Surge Currents Caused by Direct Lightning Flashes

  • Shin, Hee-Kyung;Lee, Jae-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.116-125
    • /
    • 2015
  • This paper presents experimental results obtained from actual installation conditions of surge protective devices (SPDs), with the aim of understanding the coordination of cascaded Class I and Class II SPDs. This paper also proposes effective methods for selecting and installing coordinating cascaded SPDs. The residual voltage of each SPD and the energy sharing of an upstream Class I tested SPD and a downstream Class II tested SPD were measured using a $10/350{\mu}s$ current wave. In coordinating a cascaded voltage-limiting SPD system, it was found that energy coordination can be achieved as long as the downstream SPD is a metal oxide varistor with a higher maximum continuous operating voltage than the upstream SPD; however, it is not the optimal condition for the voltage protection level. If the varistor voltage of the downstream SPD is equal to or lower than that of the upstream SPD, the precise voltage protection level is obtained. However, this may cause serious problems with regard to energy sharing. The coordination for energy sharing and voltage protection level is fairly achieved when the cascaded SPD system consists of two voltage-limiting SPDs separated by 3 m and with the same varistor voltage.

Residual life evaluation of pressurizer surge line nozzle in nuclear plant (원자력발전소 가압기 밀림관 노즐의 잔존 피로수명평가)

  • Lee, Kang-Yong;Kim, Jong-Sung;Bae, Jung-Il;Jin, Tae-Eun;Youm, Hak-Ki;Hong, Seong-Yul;Jeong, Il-Suk;Kim, Yoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.8
    • /
    • pp.1259-1269
    • /
    • 1997
  • The procedure for the determination of the residual life of the pressurizer surge line nozzle in the nuclear plant is developed. The design fatigue life for the 1800 $ft^3$ pressurizer surge line nozzle in cast head design is compared with that of Westinghouse stress report, and the percentage difference between two results is less than 9%. The design fatigue life evaluation of the 1000 $ft^3$ pressurizer surge line nozzle in fabricated head design is carried out, and the consuming rate and residual life are estimated using the operating data.

Inundation Analysis Considering Water Waves and Storm Surge in the Coastal Zone (연안역에서 고파랑과 폭풍해일을 고려한 침수해석)

  • Kim, Do-Sam;Kim, Ji-Min;Lee, Gwang-Ho;Lee, Seong-Dae
    • Journal of Ocean Engineering and Technology
    • /
    • v.21 no.2 s.75
    • /
    • pp.35-41
    • /
    • 2007
  • In general, coastal damage is mostly occurred by the action of complex factors, like severe water waves. If the maximum storm surge height combines with high tide, severe water waves will overflow coastal structures. Consequently, it can be the cause of lost lives and severe property damage. In this study, using the numerical model, the storm surge was simulated to examine its fluctuation characteristics at the coast in front of Noksan industrial complex, Korea. Moreover, the shallow water wave is estimated by applying wind field, design water level considering storm surge height for typhoon Maemi to SWAN model. Under the condition of shallow water wave, obtained by the SWAN model, the wave overtopping rate for the dike in front of Noksan industrial complex is calculated a hydraulic model test. Finally, based on the calculated wave-overtopping rate, the inundation regime for Noksan industrial complex was predicted. And, numerically predicted inundation regimes and depths are compared with results in a field survey, and the results agree fairly well. Therefore, the inundation modelthis study is a useful tool for predicting inundation regime, due to the coastal flood of severe water wave.

Clinical Evaluation of Endogenous LH Surge in Superovulation Cycle for I.V.F. (체외수정을 위한 과배란유도 주기에서 내인성 LH Surge의 발생에 관한 연구)

  • Kim, Tak;Kim, Sun-Haeng;Ku, Pyong-Sham;Joo, Kap-Soon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.16 no.1
    • /
    • pp.93-101
    • /
    • 1989
  • 71 cycles of 67 women were treated for superovulation induction in our IVF & ET program from May to September in 1988. Endogenous LH surges were occurred in 21 cycles out of 71 cycles. And then, we selected 50 cycles without endogenous LH surge treated in the same period as control group. We compared egg recovery rate, egg maturity, fertilization rate, cleavage rate and pregnancy rate of study group with those of control group. We were able to detect more than 90% of endogenous LH surge by commencing daily LH monitoring on MCD 9. The egg recovery rate, egg maturity, fertilization rate, and pregnancy rate of the study group were not statistically different from those of the control group. Significantly lower cleavage rate was seen in the study group compared with that of control group. Above results suggested that the cycles with endogenous LH surge do not have to be abandoned and can be treated continuously to achieve successful pregnancy.

  • PDF

The Method of Reinforcing the Immunity of Residual Current Circuit Breaker for the EMC Composite Surge (누전차단기의 EMC 조합서지 내성 강화를 위한 방안)

  • Kim Jae-Chul;Han Yoon-Tak;Kim Oun-Seok;Seol Kyu-Hwan;Kang Jang-Kyou;Moon Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.8
    • /
    • pp.322-328
    • /
    • 2006
  • In this paper, The impulse un-tripping characteristics and the electro magnetic compatibility characteristics are compared with each other. The performance of impulse un-tripping test exists at domestic standard (KSC 4613). However test items are insufficient because the more test items such as EMC exist at international standard (IEC). Also, Electric Appliances Safety Certificate has taken the certificate test since July 2004 in Korea but did not confirm the EMC performance for RCCBs made in Korea. Thus, in this paper, We experiment with Oscillatory waves immunity test and the 7 EMC tests for 32 RCCBs of 4 types (mini, home standard, plug, outlet) for 16 brands according to IEC standard 61009-1 and 61008-1. As a result, 24 RCCBs proved to be poor for surge immunity test. However the RCCBs operating incorrectly for surge immunity test operate correctly for oscillatory waves immunity test. Thus, the correlation between oscillatory waves immunity test and EMC test is little and standard for compatibility of combination surge at IEC 61000-4-5 should be added to KS standard as soon as possible.

The Vulnerability of the Reclaimed Seashore Land Attendant Upon Storm Surge/Coastal Inundation (해일/범람에 따른 해안 매립지의 취약성)

  • Kang, Tae-Soon;Moon, Seung-Rok;Nam, Soo-Yong;Shim, Jae-Seol
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.68-75
    • /
    • 2010
  • Recently, the intensity and frequency of typhoons have been on the increase due to unusual weather phenomena and climate change. In particular, on September 13, 2003, typhoon MAEMI (0314) caused heavy damage in the provinces of Busan and Gyongnam, but also provided an opportunity to perform a variety of studies on storm surge. According to investigation reports on the damage resulting from typhoon MAEMI, the areas where coastal inundation occurred were located in reclaimed land under coastal development. In this study, through an image data analysis of historic and present day typhoons affecting Masan, we found that the inundation damage areas corresponded to reclaimed lands. Therefore, using the area around Busan, including the southeastern coast of Korea where typhoons lead to an increased storm surge risk, we performed a storm surge/inundation simulation, and examined the inundation effect on reclaimed land due to the intensified typhoons predicted for the future by climate change scenarios.

Effect of Sintering lime on Electrical Stability against Surge Stress of Zn-Pr-Co-Cr-Y Oxide-based Varistors (Zn-Pr-Co-Cr-Y 산화물계 바리스터의 써지 스트레스에 대한 전기적 안정성에 소결시간의 영향)

  • Nahm, Choon-Woo;Park, Jong-Ah;Yoo, Dea-Hoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.7
    • /
    • pp.615-621
    • /
    • 2005
  • The electrical stability against surge stress of varistors, which are composed of Zn-Pr-Co-Cr-Y oxide system, were investigated at different sintering times. As sintering time increases, the varistor voltage and nonlinear exponent decreased in the range of $279.6\~179.1$ and $52.5\~24.9$, respectively. On the contrary, the leakage current and dielectric dissipation factor increased in the range of $1.2\~9.8\;{\mu}A$ and 0.0461\~0.0651 with increase of sintering time. For all varistors, the variation rates of V-I characteristic parameters against surge stress were more strongly affected in order of varistor voltage ${\rightarrow}nonlnear$ $exponent{\rightarrow}leakage$ current. On the whole, the electrical stability against surge stress increased with increasing sintering time. Conclusively, it is assumed that the varistors sintered for 2 h exhibited comparatively good characteristics, in view of overall characteristics.

Regional Extension of the Neural Network Model for Storm Surge Prediction Using Cluster Analysis (군집분석을 이용한 국지해일모델 지역확장)

  • Lee, Da-Un;Seo, Jang-Won;Youn, Yong-Hoon
    • Atmosphere
    • /
    • v.16 no.4
    • /
    • pp.259-267
    • /
    • 2006
  • In the present study, the neural network (NN) model with cluster analysis method was developed to predict storm surge in the whole Korean coastal regions with special focuses on the regional extension. The model used in this study is NN model for each cluster (CL-NN) with the cluster analysis. In order to find the optimal clustering of the stations, agglomerative method among hierarchical clustering methods was used. Various stations were clustered each other according to the centroid-linkage criterion and the cluster analysis should stop when the distances between merged groups exceed any criterion. Finally the CL-NN can be constructed for predicting storm surge in the cluster regions. To validate model results, predicted sea level value from CL-NN model was compared with that of conventional harmonic analysis (HA) and of the NN model in each region. The forecast values from NN and CL-NN models show more accuracy with observed data than that of HA. Especially the statistics analysis such as RMSE and correlation coefficient shows little differences between CL-NN and NN model results. These results show that cluster analysis and CL-NN model can be applied in the regional storm surge prediction and developed forecast system.

Diagnostic Techniques of Lightning Arresters for DC Electric Traction Vehicles (직류전동차용 피뢰기 진단기술)

  • Kil Gyung-Suk;Song Jae-Yong;Kim Il-Kwon;Moon Seung-Bo;Shin Gwang-Chul
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.357-361
    • /
    • 2006
  • This paper dealt with the performance evaluation and the diagnostic techniques of lightning arresters for DC electric traction vehicle. Field Measurements on the protective operation of lightning arresters against surge currents were carried out on running vehicles to acquire the data necessary for the diagnosis. The frequency and the magnitude of surge events were analyzed. Surge currents of $1\sim3$ times were recorded in one running service route and their magnitudes were ranges of $150A\sim2kA$. Also, an acceleration experiment on a lightning arrester by the standard lightning impulse current of 8/20 us and 5 kA was performed to know the aging characteristics. After the surge current application of 3,000 times, the reference voltage decreased by 4.5 %, and the leakage current was below 10 uA at the continuous operating voltage and about 50 uA at the rated voltage. From the experimental results, we propose a decision level of leakage current for the arrester used in this paper and designed an arrester tester which analyzes arrester condition by the magnitude of leakage current.