• Title/Summary/Keyword: surface-coated

Search Result 3,098, Processing Time 0.029 seconds

Preparation of Alumina Coated Zirconia Powder by Hydrolysis of Aluminum Butoxide (가수분해법에 의한 알루미나 코팅 지르코니아 분말의 제조)

  • Lee, Jong-Kook;Kim, Yoon-Soo;Kim, Hwan
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.12
    • /
    • pp.1401-1407
    • /
    • 1995
  • Zirconia powder coated with alumina was prepared by hydrolysis of alumina butoxide. The coated powder was obtained by a hydrolysis reaction between the adsorbed water on the surface of zirconia particles and aluminum sec-butoxide. Amorphous aluminum hydroxide was uniformly coated on the surface of zirconia particles with the thickness of about 30 nm. The shape and distribution of aluminum hydroxide was varied with an existence of surfactant. The coated layer of aluminum hydroxide consists of the fine particle size, and the zirconia powder coated by alumina hydroxide have the large specific surface area of 120 $m^2$/g, compared with that of starting zirconia powder.

  • PDF

Relationship between Working Parameter and Surface Nniformity of ITO coated Glass Substrate using Regression Analysis (회귀분석을 이용한 ITO 코팅유리기판의 표면균일도와 운전변수의 상관관계 분석)

  • 김면희;이상룡;이태영;배준영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1353-1356
    • /
    • 2004
  • In recent year, OLED(organic light emitted display) is used as the next generation device of FPD. OLED have been replacing the flat panel display device such as LCD, STN-LCD and TFT because this device is more efficient, economic and simple than those FPD devices, and this need not backlight system for visualization. The performance and efficiency of OLED is related with surface defect of ITO coated glass substrate. The typical surface defect of glass substrate is nonuniformity and bad surface roughness. ITO coated glass substrate is destroied for inspection about surface roughness and non-uniformity. Generally detection of the defects in the surface for ITO coated glass substrate is dependent on operator's experience. In this research, relationship between working parameter and surface non-uniformity is studied using regression analysis.

  • PDF

Surface Characteristics of HA Coated Dental Implant Alloy by Sol-Gel Method (Sol-Gel법으로 HA코팅된 치과용 임플란트 합금의 표면특성)

  • Choe Han-Cheol;Ko Yeong-Mu
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.4
    • /
    • pp.167-173
    • /
    • 2005
  • Surface characteristics of HA(hydroxyapatite) coated dental implant alloy by Sol-Gel method were investigated using potentiostat, ICP, SEM, EDX, EPMA and surface roughness tester. Surface roughness of HA coated specimen by Sol-Gel showed higher than that of PVD coated specimen. Corrosion resistance increased in the order of $1\%$ lactic acid, artificial saliva, $0.5\%$ HCI and $0.9\%$ NaCl solution. Amount of Ca element release was higher than that of V and P in the $0.5\%$ HCI and $0.9\%$ NaCl solution.

Development of Surface Treatment for Hydrophobic Property on Aluminum Surface (알루미늄의 발수 표면처리 기술 개발)

  • Byun, Eun-Yeon;Lee, Seung-Hun;Kim, Jong-Kuk;Kim, Yang-Do;Kim, Do-Geun
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.4
    • /
    • pp.151-154
    • /
    • 2012
  • A hydrophobic surface has been fabricated on aluminum by two-step surface treatment processes consisting of structure modification and surface coating. Nature inspired micro nano scale structures were artificially created on the aluminum surface by a blasting and Ar ion beam etching. And a hydrophobic thin film was coated by a trimethylsilane ($(CH_3)_3SiH$) plasma deposition to minimize the surface energy of the micro nano structure surface. The contact angle of micro nano structured aluminum surface with the trimethylsilane coating was $123^{\circ}$ (surface energy: 9.05 $mJ/m^2$), but the contact angle of only trimethylsilane coated sample without the micro nano surface structure was $92^{\circ}$ (surface energy: 99.15 $mJ/m^2$). In the hydrophobic treatment of aluminum surface, a trimethylsilane coated sample having the micro nano structure was more effective than only trimethylsilane coated sample without the micro nano structure.

The Effects of Citric Acid on HA coated Implant Surface (구연산 HA임플란트 표면구조에 미치는 영향)

  • Kim, Joong-Cheon;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Chung, Jong-Hyuk;Shin, Seung-II
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.575-584
    • /
    • 2007
  • The present study was performed to evaluate the effect of citric acid on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, and HA coated surface were utilized. Pure titanium machined surface and HA coated surface were rubbed with pH 1 citric acid for 30s., 45s., 60s., 90s., and 120s. respectively. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. The specimens showed a few shallow grooves and ridges in pure titanium machined surface implants. The roughness of surfaces conditioned with pH 1 citric acid was slightly increased. 2. In HA-coated surfaces, round particles were deposited irregularly. The specimens were not significant differences within 45s. But, began to be changed from 60s. The roughness of surfaces was lessened and the surface dissolution was increased relative to the application time. In conclusion, pure titanium machined surface implants and HA coated surface implants can be treated with pH 1 citric acid for peri-implantitis treatment if the detoxification of these surfaces could be evaluated.

Effect of Coating Time on the Property of TiN-Coated Layer on High Speed Steel by Arc Ion Plating (AIP 코팅법에서 코팅 시간이 고속도강의 TiN 코팅층 성질에 미치는 영향)

  • Kim, B.J.;Joun, M.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.308-313
    • /
    • 2006
  • The effect of coating time on surface properties of the TiN-coated high speed steel(SKH51) by arc ion plating is and presented in this paper. Surface roughness, micro-hardness, coated thickness, atomic distribution of TiN and adhesion strength are measured for various coating times. It has been shown that the coating time has a deep influence more than 60 minites on the micro-hardness, coated thickness, atomic distribution of Ti and adhesion strength of the SKH51 steels, but that the coating time has little influence on the surface roughness.

  • PDF

Contact Analysis Between Rubber Seal, a Spherical Particle and Coated Steel Surface (시일과 코팅된 스틸면 사이의 구형 입자에 의한 접촉해석)

  • Park, Tae-Jo;Jo, Hyeon-Dong
    • Tribology and Lubricants
    • /
    • v.25 no.4
    • /
    • pp.225-230
    • /
    • 2009
  • Seals are very useful machine components in protection of leakage of lubricant or working fluid, and incoming of debris from outside. Various elastomer are widely used as sealing materials and the shaft surfaces are generally coated with high hardness material after heat treatment. It is generally known that the foreign debris and wear particles get stuck into sealing surface, the steel shaft surface can be damaged and worn by mainly abrasive wear. In this paper, using MARC, contact analysis are conducted to show the hard coated steel shaft surface can be fatigue failed by very small elastic particle intervened between seal and steel surface. Variations of contact and von-Mises stress distributions and contact half-widths with interference and coating thickness are presented. The maximum von-Mises stress occurs always in the coating layer or between coated layer/substrate interface. Therefore the coated sealing surface can be fatigued and then failed by very small particles. The results can be used in design of sealing surface and further studies are required.

Design of the Coated Layer Suitable with Conductive Ink for RFID(II) - Effect of coating color components on the surface resistance of conductivity ink - (RFID용 전도성 잉크에 적합한 도공층 설계 (제1보) -도공액 성분에 따른 전도성잉크의 표면저항의 변화-)

  • Jung, Hae-Sung;Kim, Chang-Geun;Lee, Yong-Kyu
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.43 no.1
    • /
    • pp.17-22
    • /
    • 2011
  • The conventional coated paper has many functional problems for printed RFID tag. This study was carried out in order to evaluate the effect of coating color components on conductivity of printed coated paper. It has been well known that the efficiency of printed RFID tag is influenced by surface properties of substrate. The required properties for suitable substrate of printed RFID tag are high smoothness and waterproof property. In this study high grammage base paper surface sized with PVA was used. Coated paper was manufactured with five different formulations. Types of coating pigments and dosage of latex were varied. It was obtained high smoothness and also less binder demand with clay than GCC. On the other hand, suitable surface resistance and smoothness of coated paper for RFID tag was obtained with 20% of latex. Besides it shows the possibility of using coated paper for printed RFID tag.

Thermal diffusion behaviors of electrogalvanized steel sheets (전기아연도금강판의 열확산 거동)

  • 김영근
    • Journal of the Korean institute of surface engineering
    • /
    • v.28 no.5
    • /
    • pp.320-328
    • /
    • 1995
  • The electroplated steel sheets were heated during the short periods(10~60 seconds) at high temperature ($360^{\circ}C$$500^{\circ}C$) in order to investigate thermal diffusion behaviors. When the steel sheets were heated for 10 seconds, all the coated layers were alloyed at $420^{\circ}C$ but at temperature lower than $400^{\circ}C$ the $\eta$ phase partially remained on the coated surface. At higher temperature, the longer the time for heat treatment the iron contents were increased in coated layer but the glossiness and whiteness of the coated surface were decreased. While the alloying phases of $\eta$, $\zeta$, $\delta_1$ and $\Gamma$ were appeared in the coated layer at the heat treatment temperature of $360^{\circ}C$, the phase was disappeared at $420^{\circ}C$ but the rests grew in size at the temperature of $440^{\circ}C$. When the heat treatment temperature and heating time were increased, the thickness of $\Gamma$ phase was rapidly increased to 0.8 $\mu\textrm{m}$. The optimum conditions for the heat treatment to prevent powdering of coated layer were obtained to heat it for 30 seconds at $400^{\circ}C$ and 10 seconds at $440^{\circ}C$, and the iron content in coated layer was suited to be 10 percents.

  • PDF

Wear Analysis of the Ti-N Coated Punch in Piercing According to the Volume of Production (생산수량에 따른 Ti-N 코팅 펀치의 마멸해석)

  • 황상홍;고대철;김병민
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.3
    • /
    • pp.149-157
    • /
    • 2000
  • Tool wear in the shearing process such as blanking, piercing and trimming is very important, because it has great effects on the dimensional accuracy, working efficiency and economy. Most of tools in the shearing process have the coated layer at surface fur good wear and corrosion resistance. When the surface of tool is teated, the wear Phenomena of coated surface layer and inner layer may be different. This paper describes a computer modelling technique by the finite element method in order to investigate the wear mechanism and to predict the wear profile of Ti-N coated tool in piercing process according to the volume of Production. Wear coefficients of the coated layer and inner layer are obtained through Pin-on-Disk wear test, respectively. To verify the effectiveness of the suggested technique, the technique is applied to wear analysis in piercing recess of piston pin and simulation results are compared with experimental ones.

  • PDF