• Title/Summary/Keyword: surface strain

Search Result 1,791, Processing Time 0.03 seconds

Mechanical and Operational Factors Affecting the Efficiency of Rice Polishing Machines (정미기의 능률에 미치는 기계적 요인및 작동조건에 관한 연구)

  • 노상하;최재갑
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.17-48
    • /
    • 1976
  • In analyzing the operational characteristics of a rice whitening machine, the internal radial pressure of the machine was measured using strain gage equipment. Changes in cylinder and feed screw configurations, screen type, cylinder speed and counter-pressure levels were examined to determine their impact on the quality and quantity of milled rice and the performance of the machine. The results are summarized as follows: 1. The internal radial pressure in the whitening chamber varied with the surface condition of the grain being processed. During the first or second pass through the machine, pressure was relatively low, reached a maximum after two to three passes with combinations I and II, three to six with combination III and then began to fall. 2. The pitch of the feed screw and the size of the feed gate opening which determine the rate of entry of grain into the whitening chamber, appeared to be the most important factor aff-::cting the degree of radial pressure, quality and quantity of milled rice and the efficiency of the machine. Using a feed screw with a wide pitch (4.8cm), radial pressure was relatively high and head rice recovery ratio \vere quite low. In this case capacity and machine effic\ulcorneriency were much higher than obtained when using a feed screw with a narrow pitch (2.3cm). Very significant responses in radial pressure, head rice recovery rates and machine capacity were observed with changes in cylinder speed and counter-pressure levels when using the wide pitch feed screw. 3. The characteristics of the screen which surrounds the whitening chamber had an important effect on whitening efficiency. The existence of small protuberances on the original screen resulted in significant increases in both machine capacity and efficiency but without a significant decrease in head rice recovery or development of excessive radial pressure. Further work is required to determine the effects of screen surface conditions and the shape of the cylinderical steel roller on the rate of bran removal, machine efficiency and recovery rates. The size of the slotted perforations 0:1 the screen affects total milled rice recovery. The opening size on the original screen was fabricated to accommodate the round shape of Japonica rice varieties but was not suitable for the more slender Indica type. Milling Indica varieties with this screen resulted in a reduction in total milled rice recovery. 4. An increase in cylinder speed from 380 to 820 rpm produced a positive effect on head rice recovery for all machine combinations at every level of counter-pressure used in the tests. Head rice recovery was considerably lower at 380rpm using a wide screw pitch when compared to the results obtained at speeds from 600 to 820 r.p.m. The effects of cylinder speed On radial pressure, capacity and machine efficiency showed contrasting results, depending on the width of the feed screw pitch. With a narrow feed screw pitch (2.3cm), a direct proportional relationship was observed bet\ulcornerween cylinder speed and both radial pressure and machine efficiency. In contrast, using a 4.8 centimeter pitch feed roller produced a series of inverse relationships between the above variables. Based on the results of this study it is recommended when milling Indica type long grain rice varieties that the cylinder speed of the original machine be increased from 500-600 rmp up to a minimum of 800 rpm to obtain a greater abrasive effect between the grain and the screen. The pitch of the feed screw should be also reduced to decr\ulcornerease the level of internal radial pressure and to obtain higher machine efficiency and increased quality of milled rice with increased cylinder speeds. Further study on the interaction between cylinder speed and feed screw pitch is recommended. 5. An increase in the counter pressure level produced a negative effect On the head rice recovery with an increase in radial pressure, capacity, and machine efficiency over all combinations and at every level of cylinder speed. 6. Head rice recovery rates were conditioned primarily by the pressure inside the whitening chamber. According to the empirical cha racteristics curve developed in this study, the relationships of head rice recovery ($Y_h$) and machine capacity ($Y_c$/TEX>) to internal radial pressure ($X_p$) followed an inverse quadratic function and a linear function respectively: $$Y_h^\Delta=\frac{1}{{1.4383-0.2951X_p^\ast+0.1425X_p^{\ast\ast}}^2} , (R^2=0.98)$$ $$Y_c^\Delta=-305.83+374.37X_p^{\ast\ast}, (R^2=0.88)$$ The correlation between capacity and power consumption per unit of brown rice expressed in the following exponential function: $$Y_c^\Delta=1.63Y_c^{-0.7786^\{\ast\ast}, (R^2=0.94)$$ These relationships indicate that when radial pressure increases above a certain range (1. 6 to 2.0 kg/$cm^2$ based On the results of the experiment) head ricerecovery decrea\ulcornerses in a quadratic relation with a inear increase in capacity but without any decrease in power consump tion per unit of brown rice. On the other hand, if radial pressure is below the range shown above, power consumption increases dramatically with a lin\ulcornerear decrease in capacity but without significant increases in head rice recovery. During the operation of a given whitening machine, the optimum radial pressure range or the correct capacity range should be selected by controlling the feed rate and/or counter-pressure keeping in mind the condition of the grain, particulary the hardness. It was observed that the total number of passes is related to radial pessure level, feed rate and counter-pressure level. The higher theradial pressure the fewer num\ulcornerber of pass required but with decreased head rice recovery. In particular, when using high feed rates, the total number of passes should be increased to more than three by reducing the counter-pressure level to avoid decreaseases in head rice recovery (less than 65 percent head rice recovery on the basis of brown rice) at every cylinder speed. 7. A rapid rise in grain temperature seemed to have a close relationship with the pressure generated inside the whitening chamber and, subsequently with head rice reco\ulcornervery rates. The higher the rate of increase, the lower were the resulting head rice recoveries.

  • PDF

Studies on the Effect of Fiber Reinforcing upon Mechanical Properties of Concrete and Crack Mode of Reinforoed Concrete (섬유보강이 콘크리트의 역학적 특성과 철근콘크리트의 균열성상에 미치는 영향에 관한 연구)

  • 박승범
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.20 no.2
    • /
    • pp.4645-4687
    • /
    • 1978
  • This study was attempted to investigate the mechanical properties of concrete and crack control effects of reinforced concrete with steel and glass fiber. The experimental program includes tests on the properties of fresh concrete containing fibers, compressive strength, tensile strength, flexural strength, Young's modulus, Shrinkage and deformation of steel or glass fiber reinforced concrete. Also this study was carried out to investigate the effect of steel or glass fiber to retard the development in reinforced concrete subject to uniaxial tension and thus facilitate the use of steels of higher strength. The major conclusions that can be drawn from the studies are as follows: 1. The effect of the fibers in various mixes on fresh concrete confirmed that fibers do have a significant effect on the properties of fresh concrete, bringing much more stable and exhibiting a signiflcant reduction in surface bleeding, and that the cohesion is greatly improved and the internal resistance increases with fiber concentration. But the addition of an excess contents and length of fibers brings about the reduction of workability. 2. With the addition of steel fibers(1.5% Vol.) to concrete, the compressive strength as compared with plain concrete showed a very slight increase, but excess addition, over 1.5% Vol. of steel and glass fiber reduced its strength. 3. Splitting tensile strength of fiber reinforced concrete showed a significant increase tendency, as compared with plain concrete. In case of containing steel fiber (2.5%, 30mm), it showed that the maximum increase rate of 1.48 times as much rate, and in case of containing glass fiber (2.5%, 30mm), the increase rate of strength was 1.25 times as much rate. 4. Flexural strength of fiber reinforced concrete showed a significant tendency, as compared with plain concrete. Containing steel fiber (2.5%, 30mm) showed the maximum increase rate of 1.64 times as much rate and containing glass fiber (2.5%, 30mm) showed the increase rate of strength of 1.32 times as much rate, and in general, the 30mm length brougth the best results. 5. The strength ratio ($\sigma$b/$\sigma$c and $\sigma$t/$\sigma$c) increased, when steel fiber's average spacing was up to 3.05mm, but decreased when beyond 3.05mm, and it was confirmed that tensile or flexural strengths of steel fiber reinforced concrete are apparently governed by fiber's average spacing. 6. The compressive strain of fiber reinforced concrete showed a significant increasing tendency as the fiber was added, but Young's modulus. with the addition of steel and glass fibers, showed a slight decrease tendency. And according to the increase of flexural strength, a considerable increase was seen in toughness. 7. With the addition of fiber's the shrinkage of concrete was significantly decreased, in both case of adding steel fibers 12.5%, 30mm, and showed a significant decrease ratio, in average 30.4% and 36.7%, as compared with plain concrete. 8. With the increase of fiber volume fraction and length, the gained stress in reinforcing bar in concrete specimens increased in all crack widths, but at different rates, with the decrease of fiber diameter, the stress showed a considerable increasing tendency. And the duoform steel fibers showed the greatest improvement, as compared with the other types tested. 9. The influence of fiber dimensions in order of significanse on the machanical properties of concrete and the crack control of reinforced concrete was explained as follows: content, length, aspect ratio and dimeter.

  • PDF

The usefulness of skin test in evaluation of immunity to varicella (수두에 대한 면역력 평가에 있어서 피부 시험의 유용성)

  • Kim, Ji-Young;Lee, Hye Jeen;Kim, Me Jin;Kim, Young Ho;Jung, Ji A;Yang, Seung;Hwang, Il Tae;Lee, Hae Ran
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.4
    • /
    • pp.377-382
    • /
    • 2008
  • Purpose : The aim of this study is to assess the usefulness of skin test by an inactivated, 1/50 diluted solution of attenuated varicella vaccine in evaluating the immune status to varicella. Methods : Total 41 subjects (22 males, 19 females, aged 1-32 years) were enrolled from July to August, 2005. Past medical history including varicella infection, varicella vaccination were investigated through questionnaires. The skin test solution was prepared from solution of attenuated varicella vaccine(Oka strain) which was inactivated by exposure to room temperature for 10 days and diluted at 1/50 with normal saline. Skin test was done by injecting 0.1 mL of the solution intradermally into the volar surface of the right forearm and sterile normal saline was used as a control on the left forearm. Positive reaction was defined when the transverse diameter of the induration was 5 mm or more. Serum varicella zoster virus specific IgG antibody test by ELISA (enzyme-linked immunosorbent assay) was done. Results : In adults, the sensitivity of the varicella zoster virus skin test compared to ELISA was 94.7% and the positive predictive value was 100%. In children, both the positive predictive value and specificity were 100% but the sensitivity and the negative predictive value were 50% and 30.7% respectively. Children showed smaller skin test reactivity compared to adults. Conclusion : The varicella zoster virus skin test using inactivated, 1/50 diluted solution of attenuated varicella vaccine was proved as one of the useful tools for evaluating the immunity and susceptibility of the varicella zoster virus.

Effect of the Nematode Sterilization of Nursery Medium using QRD Microwave in the Plant Factory (QRD 마이크로파를 이용한 식물공장용 배지의 멸균 효과)

  • Kim, Jin Hyun;Kim, Tae Wook;Lee, Keun Woo;Ha, Yu Shin;Lee, Jae Hyun;Kim, Kyung Min
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.100-107
    • /
    • 2013
  • Unlike general microwave, QRD (Quadratic Residue Diffusor) Microwave used in this study is known as a new technology that enhances the sterilization effect with low power because it is possible to induce the average sterilization by changing wavelength phase difference. Therefore, basic research was conducted on the function that could sterilize culture media for plant factory by using environmentally friendly and low energy consuming QRD Microwave. The results are as follows: It was confirmed that there was no external deformation in the polyurethane foam and rock wool medium when changing the microwave level between 2 and 8 kW in different water content of culture media. However, PDA solid media at 2 kW were not dissolved in 60 and 180 seconds. All of the media were dissolved in other processing. There was little difference in the microwave irradiation level and surface temperature of the strain according to the processing time between Bacillus sp. and Burkholderia sp. In the sterility test according to the microwave irradiation level and processing time, it was confirmed that both Bacillus sp. and Burkholderia sp. grew in the microwave level 2 kW regardless of time. In the microwave level 6 kW, all experimental groups except the processing of Burkholderia sp. for 60 seconds were sterilized, and all of Bacillus sp. was killed in the all experimental groups. In the microwave level 8 kW, it was confirmed that both Bacillus sp. and Burkholderia sp. were sterilized regardless of time. The temperature in microwave-processed media after contaminating strains to each medium was maintained at more than 100 in polyurethane foam and rock wool medium after 60 seconds. In general, it was shown that it was possible to sterilize after 60 seconds. Therefore, it is considered that Bacillus sp. and Burkholderia sp. which are the biggest problems in the plant factory can be adequately sterilized by QRD Microwave used in this study.

Effect of Chlorella vulgaris CHK0008 Fertilization on Enhancement of Storage and Freshness in Organic Strawberry and Leaf Vegetables (Chlorella vulgaris CHK0008 시비가 유기농 딸기와 엽채소의 저장성과 신선도 향상에 미치는 영향)

  • Kim, Min-Jeong;Shim, Chang-Ki;Kim, Yong-Ki;Park, Jong-Ho;Hong, Sung-Jun;Ji, Hyeong-Jin;Han, Eun-Jung;Yoon, Jung-Chul
    • Horticultural Science & Technology
    • /
    • v.32 no.6
    • /
    • pp.872-878
    • /
    • 2014
  • This study aimed to enhance storage and freshness of strawberry fruits and foliage vegetables by spray treatment with Chlorella vulgaris as a bio-fertilizer. The tested strain, C. vulgaris CHK0008, was isolated from an organically cultivated rice paddy and identified as C. vulgaris by its morphology and 18S rDNA and 23S rDNA sequence homology. We successfully cultured C. vulgaris CHK0008 in BG11 modified medium (BG11MM) and adjusted $2.15{\times}10^6cell/mL$ C. vulgaris CHK0008 to one OD value by measuring the optical density at 680 nm using a UV-vis spectrophotometer. The soluble solid content of 'Seolhyang' and 'Yukbo' strawberry fruits treated by spray application with C. vulgaris CHK0008 was enhanced by 22.2% and 11.5% respectively, compared to untreated controls. Additionally, the decay rates of treated 'Seolhyang' and 'Yukbo' strawberry fruits decreased 63.8% and 74.4% respectively, compared to untreated control. Surface color changes and chlorosis of leaves in leaf vegetables such as lettuce, kale, red ornamental kale, white ornamental kale and beet were observed in samples treated with water spray for 10 days after cold storage. However, the decay rate of leafy vegetables treated with foliar application of 25% C. vulgaris CHK0008 liquid culture was significantly decreased compared to that of the untreated control during storage at $4^{\circ}C$.

Optical Characteristic on the Growth of Centric Diatom, Skeletonema costatum (Grev.) Cleve Isolated from Jinhae Bay in Korea (진해만에서 분리한 중심목 규조류 Skeletonema costatum(Grev.) Cleve의 성장에 미치는 광학적 특성)

  • Oh, Seok-Jin;Kang, In-Seok;Yoon, Yang-Ho;Yang, Han-Soeb
    • Korean Journal of Environmental Biology
    • /
    • v.26 no.2
    • /
    • pp.57-65
    • /
    • 2008
  • The effects of light quality and irradiance on the growth of centric diatom, Skeletonema costatum (Jinhae Bay strain) were investigated in the laboratory. At 20$^{\circ}C$ and 30 psu, the irradiance-growth curve showed the maximum growth rate of 1.17 day$^{-1}$ with half-saturation photon flux density (PFD) (K$_s$) of 92.4 $\mu$mol photons $m^{-2}s^{-1}$, $\mu$=1.17 (I-5.28)/(I+81.8), (r=0.98), and a compensation PFD (I$_0$) was 5.28 $\mu$mol photons $m^{-2}s^{-1}$. The 10 equated to a depth of 3$\sim$5 m from March to May, 11 m in June and 4 m from July to September in Jinhae Bay. These responses suggested that irradiance at the depth near the surface layer in Jinhae Bay would provide favorable conditions for S. costatum. To assess the effects of light (i.e. wavelengths) on the growth, nine wave-lengths were used ranging from near ultraviolet to near-infrared supplied by light emitting diode. At an irradiance level of 25 $\mu$mol photons $m^{-2}s^{-1}$, S. costatum grew under wavelengths of 405, 470, 505, 525, 568 and 644 nm, but did not grow at 590 and 623 nm; whereas S. costatum grew at all wavelengths at 100 $\mu$mol photons $m^{-2}s^{-1}$. This implies that S. costatum is likely to grow well in enclosed water bodies where suspended particles absorbs most of the blue wavelengths, and dominated by yellow-orange wavelengths.

Optimization for Underwater Welding of Marine Steel Plates (선박용 강판의 수중 용접 최적화에 관한 연구)

  • 오세규
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.1
    • /
    • pp.49-59
    • /
    • 1984
  • Optimizing investigation of characteristics of underwater welding by a gravity type arc welding process was experimentally carried out by using six types of domestic coated welding electrodes for welding of domestic marine structural steel plates (KR Grade A-1, SWS41A, SWS41B,) in order to develop the underwater welding techniques in practical use. Main results obtained are summarized as follows: 1. The absorption speed of the coating of domestic coated lime titania type welding-electrode became constant at about 60 minutes in water and it was about 0.18%/min during initial 8 minutes of absorption time. 2. Thus, the immediate welding electrode could be used in underwater welding for such a short time in comparison with the joint strength of in-atmosphere-and on-water-welding by dry-, wet-or immediate-welding-electrode. 3. By bead appearance and X-ray inspection, ilmenite, limetitania and high titanium oxide types of electrodes were found better for underwater-welding of 10 mm KR Grade A-1 steel plates, while proper welding angle, current and electrode diameter were 6$0^{\circ}C$, above 160A and 4mm respectively under 28cm/min of welding speed. 4. The weld metal tensile strength or proof stress of underwater-welded-joints has a quadratic relationship with the heat input, and the optimal heat input zone is about 13 to 15KJ/cm for 10mm SWS41A steel plates, resulting from consideration upon both joint efficiency of above-100% and recovery of impact strength and strain. Meanwhile, the optimal heat input zone resulting from tension-tension fatigue limit above the base metal's of SWS41A plates is 16 to 19KJ/cm. Reliability of all the empirical equations reveals 95% confidence level. 6. The microstructure of the underwater welds of SES41A welded in such a zone has no weld defects such as hydrogen brittleness with supreme high hardness, since the HAZ-bond boundary area adjacent to both surface and base metal has only Hv400 max with the microstructure of fine martensite, bainite, pearlite and small amount of ferrite.

  • PDF

Effect of Bone Quality on Insertion Torque during Implant Placement; Finite Eelement Analysis (임플란트 식립 시 골질이 주입회전력에 미치는 영향에 관한 삼차원 유한요소 분석)

  • Jeong, Jae Doug;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.109-123
    • /
    • 2009
  • The aim of the study was to assess the influence of insertion torque of bone quality and to compare axial force, moment and von Mises stress using finite element analysis of plastoelastic property for bone stress and strain by dividing bone quality to its thickness of cortical bone, density of trabecular bone and existence of lower cortical bone when implant inserted to mandibular premolar region. The $Br{\aa}nemark$ MKIII. RP implant and cylindrical bone finite model were designed as cortical bone at upper border and trabecular bone below the cortical bone. 7 models were made according to thickness of cortical bone, density of trabecular bone and bicortical anchorage and von Mises stress, axial force and moment were compared by running time. Dividing the insertion time, it seemed 300msec that inferior border of implant flange impinged the upper border of bone, 550msec that implant flange placed in middle of upper border and 800msec that superior border of implant flange was at the same level as bone surface. The maximum axial force peak was at about 500msec, and maximum moment peak was at about 800msec. The correlation of von Mises stress distribution was seen at both peak level. The following findings were appeared by the study which compared the axial force by its each area. The axial force was measured highest when $Br{\aa}nemark$ MKIII implant flange inserts the cortical bone. And maximal moment was measured highest after axial force suddenly decreased when the flange impinged at upper border and the concentration of von Mises stress distribution was at the same site. When implant was placed, the axial force and moment was measured high as the cortical bone got thicker and the force concentrated at the cortical bone site. The influence of density in trabecular bone to axial force was less when cortical bone was 1.5 mm thick but it might be more affected when the thickness was 0.5 mm. The total axial force with bicortical anchorage, was similar when upper border thickness was the same. But at the lower border the axial force of bicortical model was higher than that of monocortical model. Within the limitation of this FEA study, the insertion torque was most affected by the thickness of cortical bone when it was placed the $Br{\aa}nemark$ MKIII implant in premolar region of mandible.

Effects of Temperature and Nematode Concentration on Pathogenicity and Reproduction of Entomopathogenic Nematode, Steinernema carpocapsae Pocheon Strain (Nematoda: Steinernematidae) (온도 및 농도가 곤충병원성 선충, Steinernema carpocapsae 포천 계통 (Nematoda: Steinernematidae)의 병원성과 증식에 미치는 영향)

  • 추호렬;이동운;윤희숙;이상명;항다오싸이
    • Korean journal of applied entomology
    • /
    • v.41 no.4
    • /
    • pp.269-277
    • /
    • 2002
  • Ecological studies on entomopathogenic nematodes are required to increase control efficacy against target insect pests and to obtain basic information for mass production. Thus, effect of temperature and nematode concentration on infectivity and reproduction of Steinernema carpocapsae Pocheon and that of exposure time and soil depth on infectivity were examined using Galleria mellonella larvae. Infectivity and reproduction were examined at five temperatures, 13, 18, 24, 30 and 35$^{\circ}C$ with seven concentrations, 0, 5, 10, 20, 40, 80 and 160 infective juveniles (IJs)/larva. Temperature and nematode concentration influenced infectivity and reproduction of S. carpocapsae Pocheon. Although G. mellonella larvae were killed by S. carpocapsae Pocheon at all given temperatures and nematode concentrations, mortality was higher at 24$^{\circ}C$ than other temperatures. Lethal time of G. mellonella by S. carpocapsae Pocheon was shorter with increasing temperature and nematode concentrations. S. carpocapsae Pocheon was not established in G. mellonella at 13 and $35^{\circ}C$. Time for the first emergence from G. mellonella cadaver was longer $18^{\circ}C$ (about 20 days) than 24 and $30^{\circ}C$ (about 5 days). The highest number of progenies was obtained at $24^{\circ}C$ with 80IJs/1arva, i.e., $18.8$\times$10^4$IJs were produced from a larva. In the exposure time assay, G. mellonella death was recorded in 10 minutes when 300 IJs were inoculated per larva. When S. carpocapsae Pocheon was inoculated at the rate of $10^{9}$ IJs/ha to G. mellonella at the depth of 0, 2, 5 and 10 cm of sand columns, 100% mortality and similar sex ratio were observed but number of established IJs in cadaver was decreased with deepening the soil depth. The results indicated that optimum temperature for infectivity and reproduction of S. carpocapsae Pocheon was $24^{\circ}C$ In addition, S. carpocapsae Pocheon was effective to target insects within 5 cm from the soil surface.

Development of Optimum Grip System in Developing Design Tensile Strength of GFRP Rebars (GFRP 보강근의 설계 인장강도 발현을 위한 적정 그립시스템 개발)

  • You Young-Chan;Park Ji-Sun;You Young-Jun;Park Young-Hwan;Kim Keung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.947-953
    • /
    • 2005
  • Previous test results showed that the current ASTM(American Standard for Testing and Materials) grip adapter for GFRP(Glass Fiber Reinforced Polymer) rebar was not fully successful in developing the design tensile strength of GFRP rebars with reasonable accuracy. It is because the current ASTM grip adapter which is composed of a pair of rectangular metal blocks of which inner faces are grooved along the longitudinal direction does not take into account the various geometric characteristics of GFRP rebar such as surface treatment, shape of bar cross section as well as physical characteristics such as poisson effect, elastic modulus in the transverse direction and so on. The objective of this paper is to provide how to proportion the optimum diameter of inner groove in ASTM grip adapter to develop design tensile strength of GFRP rebar. The proportioning of inner groove in ASTM grip adapter is based on the force equilibrium of GFRP rebar between tensile capacity and minimum frictional resistance required along the grip adapter. The frictional resistance of grip adapter is calculated based on the compressive strain compatibility in radial direction induced by the difference between diameter of GFRP rebar and inner groove In ASTM grip. All testing procedures were made according to the CSA S806-02 recommendations. From the preliminary test results on round-type GFRP rebars, it was found that maximum tensile loads acquired under the same testing conditions is highly affected by the diameter of inner groove in ASTM grip adapter. The grip adapter with specific dimension proportioned by proposed method recorded the highest tensile strength among them.